| 1 | Taking down cement plaster on brick/concrete surfaces or stone walls, ceiling, etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed .NOTE- Work will be carried out upto 2nd storey of bldgs also as per direction of Engr-in-charge including necessaryscaffolding required as per site conditions & no extra payment shall be made on this account. |
| 2 | Rendering 10+5 mm thick on fair faces of brick or concrete surface walls in two layers, in cement mortar 1:4 , rendering is to be finished even and fair without using extra cement (up to 2nd storey with necessary scaffolding) complete all as specified and as directed by Engineer-in-charge. |
| 3 | Rendering 10 mm thick cement plaster in cement mortar 1:6 on on brick /stone/concrete surfaces finished even and smooth without using extra cement (upto 2nd storey with necessary scaffolding), complete all as specified and directed. |
| 4 | Rendering 5 mm thickon concrete surfaces in CM 1:3 on ceiling finished even and smooth without using extra cement , complete all as specified and directed . |
| 5 | Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed . |
| 6 | Brick work withsub class\"B\" burnt bricks straight or curved on planexc. 6 m mean radius built in CM 1:6 complete all as specified and directed . |
| 7 | Brick work withsub class\"B\" burnt old size bricks straight or curved on planexc. 6 m mean radius bult in CM 1:6 but except bricks,complete all as specified and as directed. |
| 8 | Brick work withsub class\"B\" burnt bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed . |
| 9 | PCC 1:2:4 type B-1 (using 20 mm graded stone crushed aggregate) as in coping, bed blocks etc complete all as specified and directed. |
| 10 | Taking down shutter of any description not exc. 1.0 sqmeach and removing to store.complete all as specified and as directed. |
| 11 | Taking down shutter of any description exc 1.00 Sqm but not exc. 2.0 sqmeach and removing to store.complete all as specified and as directed. |
| 12 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.5 square metre each including cutting holes for taking out hold fasts of dismantling brick work ( holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed. |
| 13 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc 1.5 sqm but not exceeding 4 square metre each including cutting holes for taking out hold fasts of dismantling brick work ( holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed. |
| 14 | Pressed steel frames 105mm x 60mm made out of size 1.25 mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hold fast,hinges, lock strike plate, etc and making good in CM 1:3 or cement concrete 1:2:4 Type B-1 including PCC 1:3:6 C-1 as in back filling to chowkhats .complete all as specified and directed . |
| 15 | Pressed steel frames 125mm x 60mm made out of size 1.25 mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hold fast,hinges, lock strike plate, etc and making good in CM 1:3 or cement concrete 1:2:4 Type B-1 including PCC 1:3:6 C-1 as in back filling to chowkhats .complete all as specified and directed . |
| 16 | 2nd class hard wood 35mm thick factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified anddirected . |
| 17 | 2nd class hard wood Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified anddirected . |
| 18 | Flush shutters 30 mm thick solid core construction with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed. |
| 19 | Factory made solid PVC door frame of size 50x47mm made out of 5mm thick prelam PVC sheet with one or more rebate reinforced with MS square tube, fixed in opening as per specification & drawing No CEPZ/TD-378/11 sheet No 1/1, etc complete all as specified and directed. |
| 20 | Factory made Solid panel PVC Door Shutter, 30mm thick (style),consisting of frame made of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles & rails with suitable PVC sheet beadding and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed. |
| 21 | Factory made solid PVC moulded door shutter 28 to 30 mm thick (stiles) with partical board core with 2, 4 or 6 raised panel design with 2 mm thick moulded prelam PVC sheet on the front face & back face to be fitted in the mild steel frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per specification and drawings. |
| 22 | Double shutter Box type steel windows comprised of tubular frame and shutters made out of outer frame ERW tube \"P\" section (60x45x25)mm and shutters of ERW tube \"P\" section (50x35x20)mm openable shutters side hung including piston hinges with two nos of MS tower bolts 150 mm size on each shutter steel handle and stopper of \"Z\" section as specified completewith sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings / opening for cooler / AC where required. Steel windows will be double shutter external glazed and internal wire glazed complete all as specified and as per drawings no. CEPZ/TD-324/07 sheet 1/3 to 3/3.NOTE- The quoted rate against the above item shall also include-(i) 4 Nos MS steel lugs of 20x5 mm MS flat 20 cm long over all welded to frames(ii) PCC block for embedding lugs. |
| 23 | Double shutter Box type steel ventilators comprised of tubular frame and shutters made out of outer frame ERW tube \"P\" section (60x45x25)mm and shutters of ERW tube \"P\" section (50x35x20)mm openable shutters side hung including piston hinges with two nos of MS tower bolts 150 mm size on each shutter steel handle and stopper of \"Z\" section as specified completewith sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings / opening for cooler / AC where required. Steel ventilators will be double shutter external glazed and internal wire glazed complete all as specified and as per drawings no. CEPZ/TD-324/07 sheet 1/3 to 3/3.NOTE- The quoted rate against the above item shall also include-(i) 4 Nos MS steel lugs of 20x5 mm MS flat 20 cm long over all welded to frames(ii) PCC block for embedding lugs. |
| 24 | Framed work such as grills,gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 , complete all as specified and directed. |
| 25 | Powder coated aluminium door shutter including frame of hollow section 101mm x 44mm thickness not less than 1.53 mm including aluminium anodised powder coated of hollow section glazed shutter of stiles size 85mm x 44.45mm thickness not less than 1.56mm having grooves for aluminium beading and top rail of hollow section 83.5mm x 44.45mm thickness not less than 1.50mm, lock rail of hollow section 83.5mm x 44.45mm thickness 1.50mm and bottom rail of hollow section 114.3mm x 44.45mm thickness not less than 1.50mm, one derived handle 300 mm long, 100mm long butt hinges , aluminium floor type hydraulic door closer, aluminium mortice lock 65mm 4 levers make of Godrej, and glazing with select quality tinted glass 5mm thick or panelling with ACP sheet and cleat rubber packing aluminium beading including aluminium hardware fittings, complete all as specified and directed. |
| 26 | Aluminum Power coated, sliding windows three track with mosquito proofing with style 44.4x44.5x2mm thick including 4 mm thick coloured/tinted/frosted glass panes including all necessary fittings and fixturescomplete all as specified and directed. |
| 27 | Anodised aluminium grills, 6mm dia mesh size 100x100mmfixed to aluminium windowsand thickness of powder coating not less than 50 micron, complete all as specified and directed. |
| 28 | Repairs to steel window, ventilators of any size to make it functional (including slot pin, hinge, hook and eye of standard quality where required), resecuring of windows wire gauge and railings/grills by using welding equipments, complete all as specified and directed. |
| 29 | Repair/ easing ofwooden door any type, glazed or panelled, by trimming the side of door shutter where rubbing with chowkhat, unscrew the hinges screws and lift the door and fix with screws, tightening of wire mesh etc complete all as specified and directed. |
| 30 | Repairing aluminium shutters ( Door/ Window) including refixing, tighteningand making good with usingrubber/beads and others small fixtures/fittings if required and making serviceable , complete all as specified and directed.. |
| 31 | Dismanting of floor hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed. |
| 32 | Non-skid digital Coloured ceramic joint less tiles (1st quality) 7 to 8 mm thick(square/rectangular joint free) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a layer of mortor 15 mm thick in CM 1:4, complete all as specified and directed |
| 33 | Non-skid digital Coloured ceramic joint less tiles (1st quality) 7 to 8 mm thick(square/rectangular joint free) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in vertical surfaces dado/skirting etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screwed bed of10 mm thick in CM 1:4, complete all as specified and directed |
| 34 | Glazed coloured digital ceramic tiles (1st quality)joint freein vertical surfaces of wall of size 450x300x7mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 10 mm thick rendering in CM 1:4on brick /concrete surfaces complete all as specified and directed . |
| 35 | Light shade vitrified tiles (1st quality) 10 mm thick(square/rectangular joint free) , polished area of each tiles exc. 0.18 sqm but not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed |
| 36 | Light shade vitrified tiles (1st quality) 10 mm thick(square/rectangular joint free) , polished area of each tiles exc. 0.18 sqm but not exceeding 0.36 sqm in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering on brick or concrete surface of wall10 mm thick in CM 1:4, complete all as specified and directed |
| 37 | Light shade vitrified tiles (1st quality) 10 mm thick(square/rectangular joint free) , double charged, polished area of each tiles exc. 0.18 sqm but not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including15 mm thick screed bed in CM 1:4, complete all as specified and directed |
| 38 | Light shade vitrified tiles (1st quality) 10 mm thick(square/rectangular joint free) , double charged, polished area of each tiles exc. 0.18 sqm but not exceeding 0.36 sqm in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering on brick or concrete surface of wall10 mm thick screed bed in CM 1:4, complete all as specified and directed |
| 39 | Repair to existing PVC pipe/CI pipe including making the joints water tight by using suitable material including cleaning if required and refixing of any dia, complete all as specified and directed.Note - Work to be carried out up to 2nd storey building in any condition of working place / area. |
| 40 | Sealing of WC/floor traps joint and joints between rain water pipe and roof by using neat white cement paste or leak proof material and making the joint leak proof in case seepage is observed from WC/floor trap and joint of rain water pipe and roof slab, complete all as specified and directed. |
| 41 | Hacking out old broken glass (any thickness,size quality or description) from any types of wooden/steel/alum (up to 4th storey) frames or stone concrete or brick surrounds glazed with putty or fixed with beads.complete all asspecified and as directed . |
| 42 | 3.5 mm thick sheet glass ordinary quality glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding) |
| 43 | 3.5 mm thick figured glass, pin head type and glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron /Steel /Wood /Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding), all as specified. |
| 44 | Securing glass of any description in existing wooden and iron frames glazed with putty/beads including removing loose or decayed putty/beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work ,complete all asspecified and as directed .( New length of frame reputtied shall be measured. |
| 45 | Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple, complete all asspecified and as directed . |
| 46 | Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples.complete all asspecified and as directed . |
| 47 | Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples fixed in repair,complete all asspecified and as directed . |
| 48 | Butt hinges of mild steel cold rolled medium weight of size 100mm complete all as specified and as directed |
| 49 | Aluminium anodised, barrel tower boltssize 150 mm of extruded section and fixed complete all as specified and as directed |
| 50 | Aluminium handles, fabricated type, anodised Size-100mm, anodised section and fixed complete all as specified. |
| 51 | Aluminium alloy, anodised, sliding door bolt Size- 250 mmwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified. |
| 52 | Hasp & staple safety type aluminium anodised with mild steel hinges spin including bolt to hinges plate fixed with screws of 75 mm in length.complete all as specified and as directed |
| 53 | Aluminium hanging floor door stopper,twin rubber stopper,size 100mm , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete all as specified and as directed |
| 54 | 50 mm magnetic catches with brass body and striking plate including letting in as fixed complete all as specified and directed. |
| 55 | Aluminium bottom door seal with brushes, length 1.2 mtr, fix with screw, suitable for wooden door fixed in repair, complete all as specified and as directed |
| 56 | Mild steelhelical ordinaryrat tail rod patternsprings300mm including roller and roller plate complete including fixing to pressed steel frames necessary welding work, fixed in repair, complete all as specified and as directed |
| 57 | Aluminium extruded section body, door closer hydraulically regulated, designation No. 1, universal type, suitable for door shutters of700mm in width and of weight not more than 35kg and fixed in repair.complete all as specified and as directed |
| 58 | Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty fixed in repair, complete all as specified and as directed. |
| 59 | Brass Mortice lock with brass handles and fittings , 4 leververtical type, size 100 mmfixed in repair, complete with all accessoriesall as specified. Make:- Links Locks/ Godrej |
| 60 | Dismantling PVC/Cement/CI pipes 50 to 110 mm diaincluding allfittings like bend,branch pieces, connectors, heel rest bend etc and removing from site all as specified and directed |
| 61 | UPVC (SWR) \"B\" type pipes 75 mm bore single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and as directed by Engineer-in-charge. |
| 62 | UPVC (SWR) \"B\" type pipes 75 mm bore single socketed, in any length with rubber ringjoints fixedto walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and as directed by Engineer-in-charge. |
| 63 | UPVC (SWR)\"B\" type pipes 110 mm bore single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and as directed by Engineer-in-charge. |
| 64 | UPVC(SWR) \"B\" type pipes 110 mm bore single socketed, in any length with rubber ringjoints fixedto walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and as directed by Engineer-in-charge. |
| 65 | UPVC (SWR) , bends for75 mm bore , complete all as specified and as directed by Engineer-in-charge. |
| 66 | UPVC (SWR) , bends with access doorfor75 mm bore , complete all as specified and as directed by Engineer-in-charge. |
| 67 | UPVC(SWR) , bendsfor110 mm borecomplete all as specified and as directed by Engineer-in-charge. |
| 68 | UPVC(SWR) , bends with access door, for110 mm borecomplete all as specified and as directed by Engineer-in-charge. |
| 69 | UPVC branch piece, single (single \"Y\") with access door for 75 mm bore complete all as specified and directed. |
| 70 | UPVC branch piece, single (single \"Y\") with access door for 110 mm bore complete all as specified and directed. |
| 71 | UPVC(SWR), junction single,(single \"T\") with access door equal or unequal for 75 mm bore , complete all as specified and as directed by Engineer-in-charge. |
| 72 | UPVC(SWR), junction single,(single \"T\") with access door equal or unequal for 110 mm bore , complete all as specified and as directed by Engineer-in-charge. |
| 73 | UPVC(SWR), junction double,(double \"T\") with access door equal or unequal for 75 mm bore , complete all as specified and as directed by Engineer-in-charge. |
| 74 | UPVC(SWR), junction double,(double \"T\") with access door equal or unequal for 110 mm bore , complete all as specified and as directed by Engineer-in-charge. |
| 75 | UPVC (SWR) , reducers 110 mm dia complete all as specified. |
| 76 | UPVC (SWR) vent cowl 75 mm dia complete all as specified. |
| 77 | UPVC (SWR) floor trap plain with gratinghaving diaof out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4), fixed in repair, complete all as specified and directed. |
| 78 | UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, fixed in repair, complete all as specified. |
| 79 | 25mm outer dia stainless steel decorative drapery rod of thickness 20 gauge and for every 01 RM length, with stainless steel brackets near to ends with stainless steel finialsfor 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windowsIncluding necessary fittings, fixed in repair,complete allspecified and directed. |
| 80 | Preparation of new plastered or unplastered surfaces of ceilings andapplying three coats of white washingcomplete all as specified and as directed by Engineer-in-charge. |
| 81 | Preparation of new plastered or unplastered surfaces of walls and applying three coats of white washingcomplete all as specified and as directed by Engineer-in-charge. |
| 82 | Preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over and including a coat of wall care puttyand applying a coat of primer complete all as specified. |
| 83 | Preparationof newplastered/ concrete surfaces of walls andapplying two coats of cement based paint over and includingone coat of primer (up to 2nd storey with necessary/scaffolding)complete all asspecified and directed by Engr-in-charge. |
| 84 | Preparation of old decorated brick /concrete, plastered /un-plastered surfaces of walls, pillars, cornices etc (upto four storey bldgs) by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, rubbing with sand paperand applying one coat of lime white wash on the walls, pillars, cornices etc. complete all as specified and directed. |
| 85 | Preparation of old decorated brick /concrete, plastered /un-plastered surfaces of ceilings, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, oil, greasy spots , rubbing with sand paper and applying one coat of white wash on ceiling, complete all as specified and directed. |
| 86 | Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of oil bound distemperincluding making good uneven surface/holes with Birla wall care putty coloured in same shade where ever required etc. complete all as specified and directed. |
| 87 | Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of ceilings, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of oil bound distemperincluding making good uneven surface/holes with Birla wall care putty coloured in same shade where ever required etc. complete all as specified and directed. |
| 88 | Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of interior emulsionincluding making good uneven surface/holes with Birla wall care putty coloured in same shade where ever required etc. complete all as specified and directed. |
| 89 | Complete removal of existing treatment including washing, rubbing down with sand paper and stopping of distempered and painted surfaces including preparation of old plastered surfaces of walls andapplying two coats ofinterior emulsion over and including one coat of primerover two coats ofBirla wall care puttyon plastered surfaces, preparatory to distempering. complete all as specified and as directed by Engineer-in-charge. |
| 90 | Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of cement base paint on walls, pillars, cornices etc (upto 2nd storey with necessary scaffolding complete all as specified and directed. |
| 91 | Complete removal of existing treatment including washing, rubbing down with sand paper and stopping ofpainted surfaces including preparation of old plastered surfaces of walls, chajjas, fascia, face of columns, beams etc. andapplyingtwo coat of weather proof exterior emulsion (APEX)making good uneven surface/holes with Birla wall care putty coloured in same shade where ever required etc (up to 2nd storey with necessary scaffolding) complete all as specified and directed. |
| 92 | Preparation of old painted wooden surfaces having width/girth exceeding 10 cm including necessry putty filling with knife of same colour where required to achieve smooth and even surface and applying one coat of synthetic enamel paint on wood surfaces of any description( up to 2nd storey with necessary scaffolding)complete all as specified and directed |
| 93 | Preparation of old painted steel surfaces having width/girth exceeding 10 cm including necessry rubbing with sand paper or grinding by hand grinder to achieve smooth and even surface and applying one coat of synthetic enamel paint on steel surfaces of any description( up to 2nd storey with necessary scaffolding)complete all as specified and directed |
| 94 | Writing letters or figures (Block, Roman. Italic or Indian) n.exc 30cm high including obliterating old writing of any description n.exc 0.2 Sqm with paint to match existing work complete all as specified . |
| 95 | 50mm thick cement concrete 1:3:6, type C1, using 20mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:20 and surface finished even and smooth without using extra cement including making joint at 3m interval and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed. |
| 96 | Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents. |