Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 31-12-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-01-2023 |
| 2 | 24-12-2022 | Revised BOQ | BOQ | 31-12-2022 |
| Sl. No. | Item Description |
| 1 | Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings complete all as specified and as directed. |
| 2 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 3 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 4 | M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 15 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 5 | M & L for non skid, rectified, colour ceramic floor tiles (group B II), 600 mm X 600 mm X 10 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed. |
| 6 | S & F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. |
| 7 | M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed. |
| 8 | Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed. |
| 9 | Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 10 | M & L 4 mm thick asbestos cement plain building boards, fixed to timber frame work with screw on walls complete all as specified and directed. |
| 11 | S&F for 6mm thick Cover fillets of standard hard board 40 mm wide and fixing with screws complete all as specified and directed by Engr in charge. |
| 12 | Dismantling timber scantlings in unframed works, 40 sqcm and over in section, in any position |
| 13 | M & L for structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn in scantlings and timber fixed complete all as specified and as directed. |
| 14 | Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position |
| 15 | S & F structural timbers of group B, first or second choice as per IS 3629: 1986, planed one side with butt joints in boarding fixed in roofs, ceilings, partitions, fascia, barge, soffit, etc. (except flooring and skirting), 40 mm thick fixed with nails in any situation complete all as specified and as directed. |
| 16 | S & F structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn with butt joints in boarding fixed in roofs, ceilings, partitions, fascia, barge, soffit, etc. (except flooring and skirting), 40 mm thick fixed with nails in any situation complete all as specified and as directed. |
| 17 | Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in framed works, in any position |
| 18 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 19 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 20 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 21 | Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 22 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 23 | M & L rendering 5 mm thick in cement plaster in cement mortar (1:4) mixed with integral water proofing compound @3%by wt of cement over 10 mm thick backing coat in cm (1:4) on fair faces of brick work or concrete surface complete all as specified and directed.Note : water proofing compound shall be measured and paid separately). |
| 24 | Supply only integral water proofing compound complete all as specified and as directed. |
| 25 | M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection/paving finish all as specified and as directed. |
| 26 | M&L for filling of joints with bitumen 85/25 mixed with coarse sand (1:3) size of joint 3.00 cm x 1.00cm complete all as specified and as directed. |
| 27 | M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer complete all as specified and as directed. |
| 28 | M & L for preparation of old plastered surfaces of wall and applying two coats of cement base paint over alkali resistant priming paintq1a complete all as specified and as directed. |
| 29 | M&Lfor preparation ofnew surface of plastered wall using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller overincluding one coat of alkali resistant priming paint before distempering complete all as specified and directed. |
| 30 | M&L for preparation of old decorated surfaces including washing, rubbing down and stopping of white wash surfaces of walls (Plastered or un-plastered) including cormices pilasters etc and using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller including one coat of alkali resistant priming paint before distempering complete all as specified and directed. |
| 31 | M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 32 | M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 33 | Resecuring without taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed |
| 34 | Resecuring without taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed |
| 35 | Resecuring or easing & adjusting without taking down wooden door shutter area exceeding 2.00 sqm each complete all as specified and as directed. |
| 36 | Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed. |
| 37 | S & F flush door shutters, 35 mm thick, solid core of particle board construction, FAT-I or XPS designation, bonded with BWR adhesive with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed. |
| 38 | M & L second class hardwood 30 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | M & L for 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, cham104fered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge./*9-6374 |
| 40 | S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 41 | S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 42 | S & F aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 43 | S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 44 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 45 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 125 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 46 | S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 47 | Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 48 | S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. |
| 49 | Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting agle iron, roof top MS sheets, railings etc. |
| 50 | S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed. |
| 51 | Supply and fixing mild steel plates, plain or chequered, 5 mm thick or over in thickness in available sizes of grade E 250 quality C conforming to IS 2062: 2011 |
| 52 | S & F mild steel screw bolts (machine made), diameter of neck 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long complete all as specified and as directed. |
| 53 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge |
| 54 | Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed. |
| 56 | S & F GI wire netting 0.90 mm dia and 13 mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed. |
| 57 | Material and labour for plastering 10 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed. |
| 58 | Material and labour for plastering 10 mm thick on the other side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed. |
| 59 | S & F wash hand basins, vitreous china of size 550 x400mm(flat back or angle back type), including cutting for and pinning in ends of brackets over new angle iron erecting stand embedded in PCC (1:2:4) block including 32mm dia bore waste fitings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in redlead cement,PVC waste pipe including 15mm bore dia fancy type CP finish Pillar tap, cast copper alloy with capstan heads, screwed down high presuure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron/CPVC pipe/fittings complete all as specified and directed. |
| 60 | S & F sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed. |
| 61 | Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 16 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed. |
| 62 | Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed. |
| 63 | Dismantling water tanks capacity exceeding 500 litres but not exceeding 1000 Litres and removing to store complete all as specified and as directed. |
| 64 | S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 65 | S & F 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed. |
| 66 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 67 | M & L for coloured glazed, ceramic wall tiles (group B III) as in floor 600 mm X600 mm X 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in cement mortar (1:4), complete all as specified and directed by engineer-in-charge (Make : Johnson/Kajaria) |
| 68 | M & L for 20 to 25 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed. |
| 69 | M & L for 20 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade laid over and including 20 mm thick screed in cement mortar 1:4 and grinding and polishing complete all as specified and as directed. |
| 70 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 71 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 72 | M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 73 | S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. |
| 74 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 75 | M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 76 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps switch socket combination outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 77 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 78 | M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket socket combination outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 79 | S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. (Cat No. AHESXXW061 of make Havells REO or equivalent in Anchor/Legrand) |
| 80 | S & F switch socket combination with 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 81 | S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 82 | S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 83 | S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. |
| 84 | S&F in replacement of 10 watt LED new adore 10WB22 cool day light ball lamp complete all as specified and directed. |
| 85 | S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 86 | S&F in replacement of Recess/surface mounted 2\"x2\" LED flat light 24W lumanaire with comfortable glare free soft illimination not less than 5700K with surge proctected led driver complete all as specified and as directed.Make:Havells Cat No. LHEWEIP7IW1W034 of make Havells or, Philips, Cromption or equivalent) |
| 87 | S&F in replacement LED batten luminaires, 20 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of size 23/0.0076, from connector and ceiling rose, complete all as specified and directed. Make Havells/Bajaj/CG |
| 88 | S&F Bulkhead LED 10 Watt for bldg light ac 240V, 50Hz,New generation energy saving LED Bulkhead Neo made up of Poly carbonate housing with diffuser complete all as specified.Make-surya SLE BH 10W or equivalent |
| 89 | S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. |
| 90 | S&F MCB SP 6-32 amps B series, single pole and neutral 10KA, 240V rating, to be housed in DBs catered here in before complete all as specified and as directed. (Make : L&T Cat No. BB20400C, Schneider, ABB, Havells or equivalent) |
| 91 | S&F MCB SPN 32 Amps 10 KA, ‘C’ Curve including connection with suitable size aluminum /copper lugs complete all as specified and directed by Engr-In-Charge. (Make:- L&T Cat no BB20320C, Schneider ABB ,Havells or equivalent) |
| 92 | S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed. |
| 93 | S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 94 | S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 4 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. (Cat No. LTSD04M of make L&T or equivalent in Schineder/Legrand) |
| 95 | S & F in repair fan hook made of mild steel of existing size for mounting ceiling fan of any size complete all as specified and directed. |
| 96 | Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 2.5 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. Cost of cutting chase and making good shall be included in the quoted rate. |
| 97 | Supply and fixing exhaust fan made of study Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep cable of suitable size and connecting with ceiling rose including making hole/niche in wall to fix the fan and necessary arrangement for fixing such as frame, nuts, bolts and washers complete all as specified and directed. |
| 98 | M & L for house service bracket (hook type complete with 3.0 m long galvanised iron pipe 40 mm dia medium grade, two Nos 900 bends mild steel hook and stay or guy complete all as specified and as directed. |
| 99 | Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed. |
| 100 | Taking down ceiling fan 1200/1400 mm sweep / exhaust fans including disconnection of electric connection, dismantling blades and removing fan and blades to store complete all as specified and as directed. |
| 101 | S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, 1350 rpm, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, including capacitor to ensure power factor more than 0.9, complete all as specified and directed by Engineer-in-charge. |
| 102 | S&F bracket for street light fitting fabricated with 1200mm long and 40mm bore medium grade GI pipe bent to shape as required and fixed in positon including necessary clamps, nuts, bolts & washercomplete all as specified and directed. |
| 103 | Supply,fixing and connecting new generation energy saving environment friendly long life LED street light made up of pressure die cast aluminium housing with high power LEDs as light source and lens embedded PC cover with IP-66 protection and impact resistance of IK07 having 45 watt 5700K LED with prewired and necessary mounting GI bracket and making necessary electrical connection complete all as specified and directed. |
| 104 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. |
| 105 | S&F metal clad socket out let with MCB two pole (P+N) 20Amp including sheet metal enclosure complete 2nd class hard wood wooden boards including complete electrical connection by proper size of copper lugscomplete all as specified and as directed. MAKE : Havells cat part No. DHPPUSN020/DHDPUDP020 |
| 106 | S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. |
| 107 | Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire and taking down complete all as specified and as directed. |
| 108 | S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 4 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail