Military Engineer Services-MES has published Tender For Repair And Maintenance Of External Water Supply, Repair Of Pump, Motor, Pipe Line And Day To Day Complaints And Fire Fighting Equipments And Other Misc E/M Work At Diber Haldwani.. Submission Date for this Tender is 05-01-2023. Fire Fighting Consumable Tenders in haldwani Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

35138975
Corrigendum : Tender For Repair And Maintenance Of External Water Supply, Repair Of Pump, Motor, Pipe Line And Day To Day Complaints And Fire Fighting Equipments And Other Misc E/M Work At Diber Haldwani.
Open Tender
Indian
Uttarakhand
haldwani
05-01-2023

Tender Details

Tender For Repair And MAINTENANCE Of External Water Supply, Repair Of Pump, Motor, Pipe Line And Day To Day Complaints And Fire Fighting Equipments And Other Misc E/M Work At Diber Haldwani.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-12-2022
2 31-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
INR 8 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR & MAINT OF EXTERNAL WATER SUPPLY,REPAIR OF PUMP,MOTOR,PIPE LINEAND DAY TO DAY COMPLAINTS AND FIRE FIGHTING EQUIPMENTS AND OTHER MISC E/MWORKAT DIBER HALDWANI.
Sl. No. Item Description
1Contract details
2M&L for lifting out and removing non functional submersible pump set of any description and capacity (7.5 HP to 10 HP) & in any position, alongwith existing column pipe 50mm dia and existing submersible cable of any size from the bore well (approximately 500 feet depth of pump set from GL)after disconnecting the electrical connection from panel, dismantling existing CI bend from non return valve, and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed . (including notes mentioned here in below) 1.Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable.All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Number of column pipe may vary from 30 to 50, The existing pipes , screwed and socket joints shall be checked for its serviceability & unserviceable joints alongwith flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new socket and nut bolt, the cost of same shall be deemed to be included in the quoted rate for above item. However replacement of pipes if any required shall be measured & paid separately.
3M&L in replacement of existing U/S MS water tubing as in column pipe, 50mm bore, medium grade of thickness 4.5mm, ISI marked, conforming to relevant IS for column pipe in required length but length not more than 3.00 mtr, both end threaded. One end internally and other end externallythreaded and duly welded with pipe using 4 Nos MS strips of size 20x 3mm in triangular right angled shapewith provision of 04 Nos holes and side slot for passing submersible cable on threaded end, including painting with two coats of anti corrosive bituminous paint over a coat of red oxide primer complete all as specified and directed.
4Taking out & removing old burnt out windings wire of the submersible electric motors of 7.5 HP, Three phase, 415 Volts, 50 Hz, AC supplycapacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor wireincluding cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site complete all as specified and directed Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
5(a) Gun metal bush
6(b)Thurst plate
7(c) Shaft Grinding and polishing
8Dismentalling of submersible pumpset of capacity 7.5 HP cleaning and inspection ofparts removal all defective parts & replacement of defective impellers, bushes, shaft, locking pin and non return valve,rematling and repairing of repairable itemreassembling testing and commissioning all as directed by eng in charge.Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under this item saperately as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
9(a) Impeller
10(b) Difuser
11(c ) Gunmetal bushes
12(d) Coupler for motor and pump
13(e) Non return valve
14Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well alongwith column pipe 50mm dia and submersible cable of any size (approximately 500 feet depth of pump set from GL) including making necessary electric connections and providing water tight cable joint & testing the pump set after lowering complete all as specified and directed (including notes mentioned here in below) NOTES :- 1.Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable.All necessary T&P and equipments required for lowering of pump set etc shall be arranged by the contractor at his own cost. 2.Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes with MS internally threaded flange welded with column pipe by using 04 Nos 20x3mm MS strips and thereafter jointed with rubber gasket joints and nuts, bolts / pump set at the end / submersible cable and making necessary connections and testing including reconnecting water supply system. The required materials like column pipe /flanges with rubber gasket joints/ submersible cable/ repaired pump sets etc shall be met out with old retrieved materials and additional quantity of column pipe, flanges with rubber gasket joints , submersible cable& straight through joint of cable shall be measured and paid for separately under respective item of this Schedule as “Supply only”, but the rate for its fixing shall be deemed to be included under this item.
15Supply only 4 Sqmm, 3 Core, flat submersible Cable, PVC insulated, PVC sheathed with multi-stranded copper conductors, conforming to IS : 694- 1990 of 1100 Volt grade, dismantled/fixed under Sch ‘A’ item No. 1 here in above complete all as specified and directed .
16Disconnecting and taking up or down old existing GI tubing and connections20 mm bore,including connected fittings/accessories and fixtures of any description/ grade and in any position in trenches/under floors/road / on walls etc and making good the disturbed surface complete all as specified and directed
17ditto but 25 mm bore
18ditto but 40 mm bore
19ditto but 50 mm bore
20Supply, fixing, laying, jointing & testing 20 mm bore of galvanised iron water tubing "medium grade" conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete all as specified and directed
21ditto but 25 mm bore
22ditto but40 mm bore
23ditto but50 mm bore
24Refixing old steel tubbing20 mm bore and connection in new or old position in (trenches,wall, ceilling, floor,roadetc) complete all as specified and directed
25ditto but 25 mm bore
26ditto but40 mm bore
27ditto but50 mm bore
28Disconneting the water supply to existing over head tank of capacity 500 ltr , washing , cleaning and removingscales,silt or dirt from the tank and refixing the same in position includingwashing internal surface of tank with the help of bleaching powder etc complete all as specified and directed
29Disconneting the water supply to existing over head tank of capacity 1000 ltr , washing , cleaning and removingscales,silt or dirt from the tank and refixing the same in position includingwashing internal surface of tank with the help of bleaching powderetc complete all as specified and directed
30S&F in repair PVC water tank coverfor PVC water tank capacity not exc 1000 ltrincludingcomplete fittings all as directed .Make- Syntex/Polywell/Prayag
31S&F in repair rotational moulded polythene water storage tank ( Cylindrical vertical with closed top) hoisted and in fixed in position 500 ltrs capacity includingcomplete fittings all as directed. Make- Syntex/Polywell/Pryag
32S&F in repair rotational moulded polythene water storage tank ( Cylindrical vertical with closed top) hoisted and in fixed in position 1000 ltrs capacity includingcomplete fittings all as directedMake- Syntex/Polywell/Pryag
33S&F in repair rotational moulded polythene water storage tank ( Cylindrical vertical with closed top) hoisted and in fixed in position 2000 ltrs capacity includingcomplete fittings all as directed. Make- Syntex/Polywell/Pryag
34M&L for servicing/overhauling/repairing of existing defective centrifugal pump of following capacity ,3 Phase,415 volts, AC supplyand cleaning, oiling/greasing, fixing of serviceable parts in position, oiling/greasing,refixing of serviceable parts in position,balancing, realignment etcreplcement of nut bolt washer where required, weldingbraging andtrasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete all as specified and directed. Booster/centrifugal pumpof capacity 60 HP (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
35(a) Booster/centrifugal pumpof capacity 25 HP,
36(b) Booster/centrifugal pumpof capacity 7.5HP,
37(c) Booster/centrifugal pumpof capacity 5HP,
38(d) Booster/centrifugal/monoblock pumpof capacity 3 HP,
39(e) Booster/centrifugal/Monoblock pumpof capacity 1 HP,
40Disconnecting and removing of following old existing non functional booster pump / centrifugal pump of any description and in any position, dismantling and strip opening of the motor and pump, for carrying out repair/ servicing /overhauling mechanically and electrically, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, ie bearing,connecter, fan blade, nuts and bolts etc with and including removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor 7.5 HP operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in above quoted rates.
41(a) Ball bearing no6308 of SKF
42(b) Ball bearing no6208 of SKF
43(c)Gun metal Bush
44(d) CI Impellar
45(e )Connection plate
46(f) Cooling fan blade
47Disconnecting and removing of following old existing non functional booster pump / centrifugal pump of any description and in any position, dismantling and strip opening of the motor and pump, for carrying out repair/ servicing /overhauling mechanically and electrically, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, ie bearing,connecter, fan blade, nuts and bolts etc with and including removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor 5 HP operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in above quoted rates.
48(a) Ball bearing no6306 of SKF
49(b) Ball bearing no6206 of SKF
50(c)Gun metal Bush
51(d) CI Impellar
52(e )Connection plate
53(f) Cooling fan blade
54Supply only bleaching powder in 25 Kgs bag having 35 % chlorine contentof Ein C approved make. Chlorine liquid.
55M&L for Cleaning of UG sump of residential area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat oflime wash on inner surfaces, after drying up of capacity 30000 ltr located at domestic area. All as directed and approved by Engineer-in-Charge
56M&L for Cleaning of UG sump of techanical area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces ofthe tank of inner surfaces . carrying out two coat oflime wash on inner surfaces,after drying up of capacity 20000 ltr located behind the admin building. All as directed and approved by Engineer-in-Charge
57M&L for Cleaning of RCC tank of techanicall Bldg and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat oflime wash on inner surfaces,after drying up of capacity 25000 ltr in two compartment, located at Technical area. All as directed and approved by Engineer-in-Charge
58M&L for Cleaning of UG sump of techanicall area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat oflime wash on inner surfaces,after drying up of capacity 75000 ltr in two compartment, located at Technical area. All as directed and approved by Engineer-in-Charge
59M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, connected to gaivanised iron strip 25 mm x 4 mm by means of bolts, nuts, check nuts and washer of gaivanised iron or steel all as shown in electrical plate no.3 connected to earthing test point all as specified or indicated including testing on completion.
60M&L for repair and removal of leakage in the mainpipe line by any means like rethreading replacement of socket, union, inserting nipple etc including earth work etc required to complete the job for size 20 to32 mm bore
61-Ditto- but 40 mm to 50 mm bore
62S&F in repair CI non return valve vertical type suitable for 80 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store make Kalpana.
63S&F in repair CI non return valve vertical type suitable for 150 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store Make Kalpana.
64S&F flexible rubber coupling of delivery vertcal pipe line of out let of pump set of size 80 mm bore with nut bolt washer etc after diisconnecting and taking out old existing coupling with old nut bolt and washer etc, complete all as directed.
65- Ditto - all as above but for pipe size 150 mm bore
66S&F in repair Brass/GM foot valve vertical type suitable for 40 mm bore pipe line including threading to pipe and connecting all as directedincluding taking outexisting one and shifting to store Make leader or equivallent.
67Inspection, tuning, callibration,connecting of cable, rewiring where required from controle panel to controle switchs and other equipment of auto functional system ,detection of fault and rectification, commisioning of main controle panel to make auto functional and testing of complete fire fighting system. Assement of serviceability of all connected equipement of fire fighting system compraising of pump set,motor,pressure tank ,pressure guage ,pressure valve electric controle panel,cable, fire hydrant,hose reel box, vertical duct, controle valves , hoses, rubber reels, syron and measurig equepements to the satisfaction of Eng- in- Charge at DIBER technical area . Minor item like cable upto 1.5 mtr, insulation tape ,marker , lugs ,separater if required will be supply and fixed by contractor, cost of the same is deemed to be included in the item of work.Notes: (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` here in after.(ii) Detail inspection/serviciability report will be submitted by the contractor cost of the same is deemed to be included in the item of workall as directed to the satisfaction of E in Charge .
68M&L for repair of old existing out door double door hose box doors, locking system and replacement of both existing broken door glasses with existing size completewith rubber beading and denting/welding all as required at site anddirected.
69M&L for repair of old existing double doorduct doors, locking system, hinges and replacement of both door glasses of existing size complete with rubber beading and denting/welding all as directed to the satisfaction of E- in -Charge
70M&Lfire hose box made out of MS sheet having thickness 18 gauge, double door, out door with glass pane, with locking arrengement of size L X W x D (800mm x 600mm x 250mm) fixed ontwo GI angle iron legs of existing size, duly painted with two coats sythatic enamelled red paint over a coat of red oxide primer and in side with white colour, including PCC foundation suitable for placing two nos of hose reel of size 15 mtr long and nozzel complete,including dismaintling of old existing one complete all as directed.
71Disconnecting and taking out old existing unserviceable pressure switches supply & fix new Industrial Pressure switch for water of exesting size complete allas directed. Make Indfos cat IPS 100 or equivallent of Denfos
72M & L for taking out old existing unserviceable water pressure guage supply & fix new water Pressure guage 4"" dia 0-14 kgs rating of complete allas directed. Make Indfos cat IPS 100or equivallent of Denfos
73Disconnecting and taking out old existing unserviceable safety relief vave of size 25 mm straight type screwed male endof brass/bronze made and supply & fix new safety release valve of size 25mm of brass/bronze complete with testing and as directed.
74Disconnecting and taking out old existing unserviceable Amp meterand supply & fix new digital Amp meter three phase bright LED display 4 digits square type complete with nut bolt and testing and commisioning all as directed. Make Schneider Cat 300461and equivalent
75Disconnecting and taking out old existing unserviceable volt meter supply & fix new anolog volt meter three phase bright0 to 500 V, square type complete with nut bolt and testing and commisioning all as directed. Make AE and equvalent
76M&L selector switch 3 Phase suitable for volt meter as per existing one
77M&L selector switch 3 Phase suitable for Amp meter as per existing one
78Taking out existing defectiveCI butterfly valve of size 80 mm bore and supply & fix new CI butterfly valves of 80 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.Make Kartar or equivallant
79Taking out existing defectiveCI butterfly valve of size 100 mm bore and supply & fix new CI butterfly valves of 100 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.Make Kartar or equivalant
80Taking out existing defective GM gate valve of size 25 mm bore and supply & fixnew GM brass gate valve of size 25 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
81Taking out existing defective GM gate valve of size 50 mm bore and supply & fix new GM gate valve of size 50 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
82Taking out existing defective GM gate valve of size 20 mm bore and supply & fix new GM gate valve of size 20 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
83Taking out existing defective stand post hydrants landing valves single controle of size 63/65 mm bore and supply & fix new fire hydrant landing valves single controll of size 63/ 65 mm bore incl replacement of rubber gasket,etc. all as directed.
84Taking out existing defective hose reel drum of 30 mtr length ISI marked complete with nozzle and coupling and supply & fix new hose reel drum of 30 mtr length ISI marked complete incl nozzle and coupling all as specified and as directed.
85Taking out existing defective RRL hose type-A 15mtr in length, complete with nozzle and coupling supply & fix newRRL hose type-A 15mtr length ISI marked complete incl brass/ GM nozzle,male and femail coupling and all as specified and as directed.
86Taking out existing defective Contactor for starter and supply & fix new Contactor of size 3 ph 415 v 25 ampincl replacement nut and bolt etc. all asdirected Make L&T Cat. No MNX9 or equvalent
87Taking out existing defective overload relay supply & fix new overload relay of size 6- 25 a incl replacement of nut and bolt etc. all as directed. Make L&T Cat No FN 3240T or equivallent.
88Taking out existing defective single phase preventorsupply & fix new single phase preventor three phase incl replacement of nut and bolt etc. all as directed. Make Minilec VSP2 or equivallent.
89Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 3, 415 V, 50 HZ, 3 phase cap up to 20 Hp make L&Tor Equivallent
90Supply and fix in replacement 4 pole power contractor 18A/20A AC3 Rating Suitable for 7.5HP / 5.6kW AC Motors Suitable for MK 1 Starters 110V AC 50Hz Control Voltage Coil as directed by Engr in Charge.
91Supply and fix in replacement MCCB 125 Amp 3 pole with thermal magnetic release 100 to 125 Amp, breaking capacity 16 KA Make L&Tcatpt no SL98653OOOO OR as per sample and directed.
92Supply and fix in replacementpower contactor 3 pole,415 volt, 50 HZ,70 to 100 Amp cap Make-L&T as per sample and directed or equivallent to other make..
93Supply and fix in replacement electronic timer 3 to 30 sec 240/415 Volt as required at sitetype ST 100 ofMakeL&T as persample or other equivallant and as directed directed.
94Supply and fix in replacement water level controller with water level controller probe for draining and filling application 240/415 Volt MakeL&T as per sample or other equivallant and as directed directed.
95M& L for supplyinstalation, testing, commisioning of fire alarm response indicator in replacement of existing unserviceable response indicator inclDisconnecting, dismantling and taking out existing unserviceablefire remote indicator to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
96M& L for supplyinstalation, testing, commisioning of fire alarm hooter/sounder with hammer built in ABS housing / MS housing (12 volt dc) connected with main controll pannel in replacement of existing unserviceable fire alarm hooter/sounder incldisconnecting, dismantling and taking out existing unserviceable fire alarm hooter/sounder to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
97M& L for supplyinstalation, testing, commisioning of fire alarm manual call point (MCP box)in replacement of existing unserviceable fire alarm manual call point inclDisconnecting, dismantling and taking out existing unserviceable fire alarm manual call point to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
98M& L for supplyinstalation, testing, commisioning of smoke detector in replacement of existing unserviceable smoke detector inclDisconnecting, dismantling and taking out existing unserviceable smoke detector to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
99M&L for collecting out water sample from bore well tank and giving it to the govt approved lab for chemical/micro biological testing like colour ,turbidity,pH,TDS,Hardness,Alkalinity etc and and then taking it from lab and giving it to the AGE Office for further submission. all as specified and as directed.
100Disconnecting and taking out old existing unserviceable/ non- functional LT Cable of size 10 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 10 square mm, 4 core . complete all as specified and directed. Make- Havells/Plaza/
101Note : Tenderers maybe noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract.