Kerala State Electricity Board-KSEB has published Development Of Distribution Infrastructure At Thiruvananthapuram District Of Kerala Stateunder Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme - (Schedule Of Rates And Prices) - Ex-Works Supply Of Materials. Submission Date for this Tender is 28-02-2023. MS Flat Tenders in thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 21-Dec-2022 | BID SUBMISSION FEE CORRIGENDUM | Fee | 07-01-2023 |
2 | 31-Dec-2022 | CORRIGENDUM II | Technical Bid | 07-01-2023 |
3 | 05-Jan-2023 | Extension of bid submission date and bid opening date | Date | 28-01-2023 |
4 | 09-Jan-2023 | TECHNICAL TVM PACKAGE | Other | 28-01-2023 |
5 | 19-Jan-2023 | CORRIGENDUM 5 TVPM PACKAGE | Other | 28-01-2023 |
6 | 24-Jan-2023 | DATE EXTENSION TVPM PACKAGE | Date | 08-02-2023 |
7 | 03-Feb-2023 | CORRIGENDUM7 TVPM PACKAGE | Other | 08-02-2023 |
8 | 06-Feb-2023 | CORRIGENDUM8 TVM PACKAGE | Other | 08-02-2023 |
9 | 10-Feb-2023 | BID SUBMISSION EXTENSION THIRUVANANTHAPURAM PACKAGE | Date | 28-02-2023 |
Sl. No. | Item Description |
1 | BOQ 1.1 - 11 KV Reconductoring using Covered Conductor |
2 | POLES for 11 KV OH line as per technical specifications approved works and as per drawing. |
3 | PSC pole 9M- /487 kg |
4 | A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm; |
5 | A pole 12 M-- do - Horizontal ties ISA 65x65x6mm; |
6 | A pole 13 m -- do - Horizontal ties ISA 65x65x6mm; |
7 | Prefabricated ItemsV cross arm(10.75kg/each), Pole top F clamp(1.5kg/each), Double C cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, including back clamp, etc made of GI Channels,angle, flats of given sizes for over head structures, GI Strip 25 x 3mm, GI Strip 25 x 6 mm, 8 SWG GI wire, 6 SWG GI wire etcas per technical specification, approved drawings and scope of work. |
8 | MS bolts and nuts with washers |
9 | Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20 mm Dia solid GS stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing. |
10 | Polymeric insulator with accessories |
11 | 11kv 45 KN, polymeric disc insulators with Anchoring clamp |
12 | 11kv polymeric pin insulator with GI pin |
13 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
14 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
15 | Earth/ Groundenhancementmaterial |
16 | LT Coil for Earthing (50mm dia, 115 turns) as per specification |
17 | 11KVCovered Conductor with following types |
18 | 3 x 70 sqmm AAAC/ ACSR HT Covered Conductor |
19 | Covered Conductor Accessories |
20 | Insulated Piercing Connector for bare to insulated connection |
21 | Mechanical Connector with heat shrink sleeve for bare to insulated connection |
22 | Insulated Piercing Connector for branching(IPC - type 2) |
23 | Insulated Piercing Connector with Al bail for earthing(maintenance earthing IPC-type3) |
24 | Heat shrinkable end cap |
25 | Mid span Joint for CC |
26 | UV resistant Insulated Cable Tie |
27 | 9 KV, 10 KA Station Class Lightning Arrestor |
28 | 9 KV, 5 kA Distribution class LA |
29 | RDSS sign Board as per specifications |
30 | 12KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions. |
31 | Fuse unit withbackalite/ FRP base 100 A |
32 | Covered Conductor Accessories |
33 | Wedge connector |
34 | New PVC Alweather proof cable for service connection |
35 | 2 C 2.5 sqmm |
36 | 4 C 16 sqmm |
37 | 4 C 25 sqmm |
38 | Providing outdoor End Termination for for 11 kV Covered conductor |
39 | ACSR Rabbit |
40 | LT Pin |
41 | LT shackle |
42 | LT Pin with insulator |
43 | packing clamp |
44 | BOQ 1.2 :11KV Reconductoring using ABC |
45 | POLES for 11 KV ABCline as per technical specifications approved works and as per drawing. |
46 | PSC pole 9M- /487 kg |
47 | A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm |
48 | A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm; |
49 | A pole 12 M-- do - Horizontal ties ISA 65x65x6mm; |
50 | Four legged Pole |
51 | Supply of 11KV ABC as per technical specification and scope of work. |
52 | 3x150+1x120sqmm(insulated messenger) |
53 | 3x120+1x95sqmm(insulated messenger) |
54 | Single core removable and re usable TEE for 11kv ABC (MVT) (Set of 3nos) |
55 | Special channel cross arm for fixing the MVT, LA with bolt and nuts, Earthwire etc. |
56 | 11KV end termination kits for 3phase |
57 | suitable for 150sqmm |
58 | suitable for 120sqmm |
59 | ABC Accessories |
60 | Heat shrinkable tube |
61 | Anchor clamp or dead end clamp suitable for HT ABC |
62 | Suspension clamp suitable for HT ABC |
63 | Stainless steel strap |
64 | stainless steel buckles |
65 | Cable ties UV plastic heavy duty around 250mm long |
66 | supply of Insulated Piercing Connector |
67 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
68 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
69 | Earth/ Groundenhancementmaterial |
70 | LT Coil for Earthing (50mm dia, 115 turns) as per specification |
71 | Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings |
72 | Lightning Arrestor |
73 | 9 KV, 5 KA, Distribution Class LA |
74 | 9 KV, 10 KA, Station Class LA |
75 | Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20 mm Dia solid GS stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing. |
76 | RDSS sign Board as per specifications |
77 | New PVC Alweather proof cable for service connection |
78 | 2 C 2.5 sqmm |
79 | 4 C 16 sqmm |
80 | 4 C 25 sqmm |
81 | 12KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions. |
82 | Fuse unit with base 100 A |
83 | GI Strip 25 x 3mm, GI Strip 25 x 6 mm, 8 SWG GI wire, 6 SWG GI wire etc |
84 | Pre-fabricated GI Channel cross arm, bracket, clamps, Galvanised Nuts, Bolts with spring washers etc as per technical specification, |
85 | Polymeric insulator with accesoeries |
86 | 11kV 45 KN, polymeric disc insulators with hardware fittings |
87 | 11kV polymeric pin insulator with GI pin |
88 | LT Pin Insulator with Pin |
89 | LT Shackle Insualtor with SBN |
90 | Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle,and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.(Excluding stay rod) |
91 | 2 line spacers 300 mm in LT ACSR bare OH line |
92 | 4 Line spacers 450 mm in LT ACSR Bare OH line |
93 | BOQ1.3:LT Reconductoring using ABC |
94 | Supply of poles as per specification and scope of work |
95 | 8 m long /380 kgs PSC Poles |
96 | 9 meter long /487 KG PSC Poles |
97 | A Type Pole, 10m - Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm |
98 | 8m long Steel Tubular poles with welded steel base plate |
99 | Supply of LT ABC as per technical specification and scope of work. |
100 | 3x95+1x70+1x16sqmm(insulated messenger) |
101 | 3x70+1x50+1x16sqmm(insulated messenger) |
102 | Supply of ABC accessories |
103 | ABC to ABC T connector |
104 | ABC to ABC Mid span joint (straight joint) |
105 | Satellite connectors for multiple service connection. |
106 | IPC for service connection |
107 | IPC for ABC to DB connection |
108 | IPC for ABC to bare conductor |
109 | LT Distribution Box suitablefor single phase and three phase service connection |
110 | Heat shrinkable tube |
111 | End cap as per cable size |
112 | Anchor clamp or dead end clamp suitable for LT ABC |
113 | Suspension clamp suitable for LT ABC |
114 | Stainless steel strap |
115 | Stainless steel buckles |
116 | Cable ties UV plastic heavy duty around 250mm long |
117 | Bimetal crimp lug as per the cable size |
118 | Nut & Bolt for LUG M12x40mm Brass |
119 | Earthingarrangement for LT line as per technical specifications and scope of work |
120 | LT Coil for Earthing (50mm dia, 115 turns) as per specification |
121 | Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings |
122 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
123 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
124 | Earth/ Groundenhancementmaterial |
125 | Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamp, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work |
126 | 3.5Cx25sqmm XLPEAluminium Cable |
127 | 25 sqmmXLPE insulated single core cable for connecting to Distribution Box |
128 | RDSS Sign Board as per specifications |
129 | 70 sqmm 1 C XLPE cable |
130 | Fuse unit withbackalite/ FRP base |
131 | 63 A |
132 | 100 A |
133 | 200 A |
134 | New PVC Alweather proof cable for service connection |
135 | 2 C 2.5 sqmm |
136 | 4 C 16 sqmm |
137 | 4 C 25 sqmm |
138 | Pre-fabricated GI Channel cross arm, bracket, clamps, Galvanised Nuts, Bolts with spring washers etc as per technical specification, |
139 | HT pin with insulator(composite type) |
140 | HT stay set complete |
141 | LT Shackle with SBN |
142 | LT Pin Insulator with pin |
143 | 2 Line x-arm with CBN |
144 | 4 Line x-arm with CBN |
145 | Insulation piercing connector for street light main :16-95sqmm, Tap : 1.5-10sqmm |
146 | IPC for ABC to Earth Connection |
147 | GI wire 4mm 8 SWG |
148 | Weather Proof Wire 1/1.8 |
149 | Weather Proof Wire 1/2.8 |
150 | XLPE cable 95sq mm |
151 | Aluminium crimping Socket 95 sqmm |
152 | BOQ1.4 Single Phase to Three Phase Conversion using ABC |
153 | Supply of poles as per specification and scope of work |
154 | 8 m long /380 kgs PSC Poles |
155 | 9 meter long /487 KG PSC Poles |
156 | Supply of LT ABC as per technical specification and scope of work. |
157 | 3x70+1x50+1x16sqmm(insulated messenger) |
158 | Supply of ABC accessories |
159 | ABC to ABC T connector |
160 | ABC to ABC Mid span joint (straight joint) |
161 | Satellite connectors for multiple service connection. |
162 | IPC for service connection |
163 | IPC for ABC to DB connection |
164 | IPC for ABC to bare conductor |
165 | LT Distribution Box suitablefor single phase and three phase service connection |
166 | Heat shrinkable tube |
167 | End cap as per cable size |
168 | Anchor clamp or dead end clamp suitable for LT ABC |
169 | Suspension clamp suitable for LT ABC |
170 | Stainless steel strap |
171 | Stainless steel buckles |
172 | Cable ties UV plastic heavy duty around 250mm long |
173 | Bimetal crimp lug as per the cable size |
174 | Nut & Bolt for LUG M12x40mm Brass |
175 | Earthingarrangement for LT line as per technical specifications and scope of work |
176 | LT Coil for Earthing (50mm dia, 115 turns) as per specification |
177 | Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings |
178 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
179 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
180 | Earth/ Groundenhancementmaterial |
181 | Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamp, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work |
182 | 3.5Cx25sqmm XLPEAluminium Cable |
183 | 25 sqmmXLPE insulated single core cable for connecting to Distribution Box |
184 | RDSS Sign Board as per specifications |
185 | Fuse unit withbackalite/ FRP base |
186 | 100 A |
187 | 200 A |
188 | New PVC Alweather proof cable for service connection |
189 | 2 C 2.5 sqmm |
190 | 4 C 16 sqmm |
191 | 4 C 25 sqmm |
192 | BOQ1.5: Installation ofnew 11KV ABC of sizes3x120+1x95sqmm(insulated messenger) |
193 | POLES for 11 KV ABCline as per technical specifications approved works and as per drawing. |
194 | PSC pole 9M- /487 kg |
195 | A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm |
196 | A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm; |
197 | A pole 12 M-- do - Horizontal ties ISA 65x65x6mm; |
198 | 10.1 M long steel Tubular poles with welded steel base plate of Designation 540 SP 72 (IS 2713, Pt I, II, III 1980) |
199 | Supply of 11KV ABC as per technical specification and scope of work. |
200 | 3x120+1x95sqmm(insulated messenger) |
201 | Single core removable and re usable TEE for 11kV ABC (MVT) (Set of 3nos) |
202 | Special channel cross arm for fixing the MVT, LA with bolt and nuts, Earthwire etc. |
203 | 11KV end termination kits |
204 | suitable for 120sqmm |
205 | ABC accessories |
206 | Heat shrinkable tube |
207 | Anchor clamp or dead end clamp suitable for HT ABC |
208 | Suspension clamp suitable for HT ABC |
209 | Stainless steel strap |
210 | Stainless steel buckles |
211 | Cable ties UV plastic heavy duty around 250mm long |
212 | Ligthning Arrester |
213 | 9KV 5KAmps polymeric surge arrester Distribution classs(3nos per set) |
214 | 9KV 10KAmps polymeric surge arrester Station classs(3nos per set) |
215 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
216 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
217 | Earth/ Groundenhancementmaterial |
218 | Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings |
219 | LT Coil for Earthing (50mm dia, 115 turns) as per specification |
220 | Galvanized stay set with anchor plate size 300x300x10mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20mm Dia solid GI stay rod and 7/3.15mm dia GI stranded wire as per technical specifications ,scope of works and as per drawing. |
221 | RDSS sign Board as per specifications |
222 | 12KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions. |
223 | Supply of insulated piercing connector |
224 | BOQ1.6:Construction of 11 KV Line using 3x300 sqmm UG Cable |
225 | Supply of 11 KV UG Cable of size 3x 300 sqmm |
226 | HDPE PipePN 6 configuration and PE grade 80 |
227 | 110 mm |
228 | 150mm |
229 | Class B4.8 mm thick GI pipe |
230 | 150 mm |
231 | Heat shrinkable Cable End Termination Kit suitable for 3 x 300 sqmm UG Cable |
232 | Indoor type |
233 | Outdoor Type |
234 | Heat shrinkable Straight joints using Shear Bolt Type as per IS 13573 Part II 2011 with dual wall and single triple extruded hybrid tubing with shear bolt connector as per IEC 61238, of rating 300/400 A |
235 | Poles for the construction of DPs/ Cut pole |
236 | PSC Poles 9M- 487 Kg |
237 | Prefabricated materials like cross arms, clamps,bolts and nuts, GI Wire of size6 SWG, GI Strip of size 25 x 3mm etc |
238 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
239 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
240 | Earth/ Groundenhancementmaterial |
241 | Properly cured Reinforced Concrete Slabs of size 40 x 30 x 5 cm , 1 : 1.5 : 3cement concrete with6mm baby metal using 6 mm TMT at 10 cm c/c -with markings as specified |
242 | Cable Route Markeras per specification |
243 | Station Classpolymer type LA, 9 KV, 10 KA with all accessories |
244 | 12KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions. |
245 | RDSS sign Board as per specifications |
246 | Hot dip Galvanized stay set with anchor plate size 300x300x10mm, 50/8mm stay clamp, stay insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20mm Dia solid GI stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing. |
247 | DO fuse unit |
248 | Supply of 11kV UG Cable of size 3x150sq mm |
249 | Supply of cable end termination kit suitable for 150sq mm UG cable |
250 | BOQ1.7:Uplifting of Transformer & RMU |
251 | DTR Substation Supports as per technical specification, approved drawings and scope of work |
252 | Bolts & Nuts & Washers of Various sizes with stud |
253 | Earthing arrangement |
254 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
255 | 1.1 KV XLPE insulated unarmoured cable for connection of transformer LV side to Distribution Box and Distribution Box to Over Head Line as per spec |
256 | 1x 120 sqmm Al conductor cable |
257 | New Distribution Transformer (Level 1) with all Accessories as per spec |
258 | Statutory Boards |
259 | RDSS Sign Board as per specifications |
260 | BOQ1.8 Installation of LT Capacitor |
261 | 9 KVAr LT Capacitor with Enclosure and Pole mounting clamps, Bolt and Nuts and Connecting Cables with all accessories etc |
262 | RDSS Sign Board as per specifications |
263 | BOQ 1.9: Installation of New Distribution Transformer of capacities 100, 160, 250, 315 and 500 KVA |
264 | DTR Substation Supports as per technical specification, approved drawings and scope of work |
265 | PSC pole 9M- /487 kg |
266 | A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm; |
267 | A pole 12 M-- do - Horizontal ties ISA 65x65x6mm; |
268 | Prefabricated Items likes V cross arm, Pole top bracket, Channel cross arm (3M,2.4M), Clamps, 2 line/4 line cross arm, Cross bracings, Guarding channels, MS flat of given sizes, GI wire, GI strip 25 x 3mm , GI strip 25 x 6mm etc as per specifications and scope of work |
269 | Bolts & Nuts & Washers of Various sizes with stud |
270 | 12KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions. |
271 | Stay Set (Galvanized) with 50X8mm stay clamp, stay insulator (2 nos), Anchor plate (300x 300x 10 mm), Nuts &Bolts, Stay Tightner/Turn Buckle, Stay Rod (1.8m long, 20 mm dia),7/3.15 mmdia GI stranded as per spec and scope of work. |
272 | PolymerInsulators with hardware fittings, hardware etc |
273 | 11 KV Disc Insulator with MS Cleat and harware fittings |
274 | 11 KV Pin Insulator with GI pin |
275 | DO Fuse Unit with support insulators |
276 | Earthing arrangement |
277 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
278 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
279 | Earth/ Groundenhancementmaterial |
280 | Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings |
281 | Lightning Arrestor |
282 | Distribution class Lightning Arrestor 9 KV, 5 KA |
283 | Station Class Lightning Arrestor 9 KV, 10 KA |
284 | ACSR Conductor Raccoon for providing drops and jumper connections |
285 | ACSR Conductor Rabbit for providing LTconnections |
286 | 1.1 KV XLPE insulated unarmoured cable for connection of transformer LV side to Distribution Box and Distribution Box to Over Head Line as per spec |
287 | 1x 95 sqmm Al conductor cable |
288 | 1x 120 sqmm Al conductor cable |
289 | 1x185 sqmm Al conductor cable |
290 | Aluminium socket |
291 | New Distribution Transformer (Level 1) with all Accessories as per spec |
292 | 11KV/433 V 100 KVA Distribution Transformer with all Accessories as per spec |
293 | 11KV/433 V 160 KVA Distribution Transformer with all Accessories as per spec |
294 | 11KV/433 V250KVA Distribution Transformer with all Accessories as per spec |
295 | LT Distribution Box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, earthing bus, earthing terminal front door operate with Fuse units & proper locking arrangement as per tech.spec |
296 | 3 Pahse 100 KVA 2/3 way Distribution Box |
297 | 3 Phase 160 KVA 3 wayDistribution Box |
298 | 3 Phase 250 KVA 3 way Distribution Box |
299 | DTR Metering |
300 | SMC DTR Box |
301 | LT CT, 415 V, -/5A, 5 VA, Class 0.5, 200/5 |
302 | LT CT, 415 V, -/5A, 5 VA, Class 0.5, 400/5 |
303 | LT CT, 415 V, -/5A, 5 VA, Class 0.5, 300/5 |
304 | LT CT, 415 V, -/5A, 5 VA, Class 0.5,600/5 |
305 | DTR Meter, 3x240V, -/5A, DTR Meter of accuracy class 0.5S |
306 | Statutory Boards |
307 | RDSS Sign Board as per specifications |
308 | LT Insulators and hardware fittings as per specification and scope of work |
309 | LT shackles Set |
310 | LTpin insulator with GI pin |
311 | Earth Knobfor neutral line and providing earth |
312 | Aluminium parallel groove clamp |
313 | 8m psc pole for mounting LT cable from distribution box |
314 | shackle insulator |
315 | ACSR Rabbit conductor for reaaranging LT feeders |
316 | BOQ Q1.10 Enhancement of Transformer |
317 | Bolts & Nuts & Washers of Various sizes with stud |
318 | Stay Set (Galvanized) with 50X8mm stay clamp, stay insulator (2 nos), Anchor plate (300x 300x 10 mm), Nuts &Bolts, Stay Tightner/Turn Buckle, Stay Rod (1.8m long, 20 mm dia),7/3.15 mmdia GI stranded as per spec and scope of work. |
319 | Earthing arrangement |
320 | 40 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete |
321 | 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap |
322 | Earth/ Groundenhancementmaterial |
323 | Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings |
324 | Lightning Arrestor |
325 | Distribution class Lightning Arrestor 9 KV, 5 KA |
326 | ACSR Conductor Raccoon for providing drops and jumper connections |
327 | 1.1 KV XLPE insulated unarmoured cable for connection of transformer LV side to Distribution Box and Distribution Box to Over Head Line as per spec |
328 | 1x 120 sqmm Al conductor cable |
329 | 1x185 sqmm Al conductor cable |
330 | 1x 240 sqmm Al conductor cable |
331 | Aluminium socket |
332 | New Distribution Transformer (Level 1) with all Accessories as per spec |
333 | 11KV/433 V 100 KVA Distribution Transformer with all Accessories as per spec |
334 | 11KV/433 V 160 KVA Distribution Transformer with all Accessories as per spec |
335 | 11KV/433 V250KVA Distribution Transformer with all Accessories as per spec |
336 | 11KV/433 V 315 KVA Distribution Transformer with all Accessories as per spec |
337 | LT Distribution Box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, earthing bus, earthing terminal front door operate with Fuse units & proper locking arrangement as per tech.spec |
338 | 3 Pahse 100 KVA 2/3 way Distribution Box |
339 | 3 Phase 160 KVA 3 wayDistribution Box |
340 | 3 Phase 250 KVA 3 way Distribution Box |
341 | 3 Phase315 KVA 4 way Distribution Box |
342 | DTR Metering |
343 | SMC DTR Box |
344 | LT CT, 415 V, -/5A, 5 VA, Class 0.5, 200/5 |
345 | LT CT, 415 V, -/5A, 5 VA, Class 0.5, 400/5 |
346 | LT CT, 415 V, -/5A, 5 VA, Class 0.5, 300/5 |
347 | LT CT, 415 V, -/5A, 5 VA, Class 0.5,600/5 |
348 | LT CT, 415 V, -/5A, 5 VA, Class 0.5,800/5 |
349 | DTR Meter, 3x240V, -/5A, DTR Meter of accuracy class 0.5S |
350 | Statutory Boards |
351 | RDSS Sign Board as per specifications |
352 | BOQ1.11 Installation of RMU(materials) |
353 | Supply of SCADA compatible RMU with FRTU , motorized both side extensible, Front cable Entry,outdoor type ring main units and Add on modules with various combinations of Load break switches and Vacuum circuit breakers as listed below with FPI, auxilliary transformer for battery charger, Terminal protector boots ,Protection relays without metering instruments with all accessories, spares etc |
354 | CTC |
355 | CC RMU MODULE |
356 | CCC |
357 | Add on C |
358 | Add on T |
359 | CTTC |
360 | Supply ofGI pipe earthing set using 40mm dia 3M long GI earth pipe with all accessories,with 6Kg 10 inch PVC pipe of length 30 cm withPVC end cap foe earth pit covering |
361 | Earth/ Groundenhancementmaterial |
362 | Prefabricated Materials like Channel Cross Arms, EarthingGI Strip of size 25X6 mm, EarthingGI Strip of size 25X3mm,6 SWG GI wire , Flats etc as per drawing and scope of works |
363 | Heat shrinkable End termination Kit suitable for 3 x 300 Sqmm XLPE cable |
364 | Station Classpolymer type LA, 9 KV, 10 KA with all accessories |
365 | 11 kV, 400A AB switch with Polymer Post Insulator with all accessories |
366 | Poles for the construction of DP structure |
367 | PSC pole 9 m- 487 kg |
368 | Hot dip Galvanized stay set with anchor plate size 300x300x10mm, 50/8mm stay clamp, stay insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20mm Dia solid GI stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing. |
369 | RDSS sign Board as per specifications |
370 | 11KV Sectionalizerand loadBreak switcheswith battery charger ,battery, auxilliary transformeretc. |
371 | Supply of 11 KV UG Cable of size 3x 300 sqmm |
372 | HDPE PipePN 6 configuration and PE grade 80 (110mm) |