}

Tender For Supply, Installation And Maintenance Of Online Continuous Effluent Monitoring System (Ocems) I.E. Ph, Bod, Cod, Tss And Flow Along With 5-Year Comprehensive Operation And Maintenance As Well As Data Transfer To Cpcb And Rspcb Server For Ru, Nimbahera-Rajasthan

Department Of Local Bodies has published Tender For Supply, Installation And Maintenance Of Online Continuous Effluent Monitoring System (Ocems) I.E. Ph, Bod, Cod, Tss And Flow Along With 5-Year Comprehensive Operation And Maintenance As Well As Data Transfer To Cpcb And Rspcb Server For Ru. Submission Date for this Tender is 12-12-2022. Organic Derivatives Tenders in Nimbahera Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

35056644
Tender For Supply, Installation And Maintenance Of Online Continuous Effluent Monitoring System (Ocems) I.E. Ph, Bod, Cod, Tss And Flow Along With 5-Year Comprehensive Operation And Maintenance As Well As Data Transfer To Cpcb And Rspcb Server For Ru
Open Tender
Indian
Rajasthan
Nimbahera
12-12-2022

Tender Details

Supply, Installation And Maintenance Of Online Continuous Effluent Monitoring System ( Ocems ) I.E. Ph, Bod, Cod, Tss And Flow Along With 5-Year Comprehensive Operation And Maintenance As Well As Data Transfer To Cpcb And Rspcb Server For Running 2Mld , Remaining Work Of Wonder Town Hall At Nimbahera , Supply , Installation, Testing & Commissioningof On Line Bod / Cod / Tss / Ph / Flow Meter In-Situ Based Analyzer As Percpcb Guideline For Online Continuous Effluentmonitoringsystem ( Ocems ) July 2018 With Panel For S.T.P. Effluent Measurement Items Uv-Vis Spectrometry Double Beam With Entire Spectrum Scanning 200 -720 Mm 190- 750Mm Wave Lengths Along With 256 Unique Pixel Diode. Make-Tethys / Xylem / Real Tech / Hach / Abb As Approved By Engineering In Charge ( All The Materials / Equipment And Apparatus Shall Be Got Approved By The Engineer In Charge Before Procurement Of The Items And There After Use In The Work. • Moc Of Bod / Cod / Tss Sensor -Titanium 3.7 F Ss316l Better • Cleaning Facility-Ultrasonic Cleaning Or Air Pressure Cleaning • Accuracy Of Bod / Cod / Tss Sensor-+ / -3% Of The Measured Value Light Source: Xenon Flash Lamp Or Following Measuring Ranges Are Required: Cod: 0-700 Mg / Ibod 0-400 Mg / 1 Tss: 0-600 Mg / 1 Ph Range 0 14 • Moc Of Ph. Sensor-Stainless Steel 316 Or Better Ph Accuracy + / 0.2% Protection Type: Ip 68 For Both The Sensor And Cable ( Cable ) Lengths Per Site Requirement ) Controller / Display- Housing Material Non Corrosive E.G. Acryl Onitrile-Styrene Acryl Ester Polymer Or Better • Protection Rating Ip 67 Controller / Display Cabin Box Should Be Ip66 Grade With Lock & Key Ss304 Grade Moc • Data Logger ( Including Data Transmission To Cpcb And Rspcb ) , Internet For Data Transmission Is In Bidders’ Scope. The Communication To The System Should Be Two Way The Data Should Be Received At Central Location And Should Be Displayed There In Real-Time In Graphical And Tabular Format. Operating Temperature 0 To 55 °C. Protection Surge Protection On Sensor Inputs, Over Voltage And Reverse Polarity Protection On Power Input. Storage 256Mb ( Industrial Microsd ) . Interface ( S ) 2 X Eia Rs485, 1 X R$232. 8 X 4-20Ma ( 1% Fs ) Usb Host 1 ( Usb 2.0 ) Voltage 9-24 Vdc 10% ( Nominal 12Vdc ) Power Sw ( Peak ) • Statistical Data Analysis ( Customizable ) For Average, Min... Max., Diurnal Variation. Auto Report To The System Should Be Two Way. The Data Should Be Received At A Central Location And Should Be Displayed There In Real-Time In Graphical And Tabular Format... Operating Temperature 0 To 55 °C. Protection Surge Protection On Sensor Inputs, Over Voltage And Reverse. Polarity Protection On Power Input. Storage 256Mb ( Industrial Microsd ) Interface ( S ) 2X Eia Rs485, 1 X Rs232, 8 X 4-20Ma ( 21% Fs ) Usb Host 1 ( Usb 2.0 ) Voltage 9-24 Vdc 10% ( Nominal 12Vdc ) Power 5W ( Peak ) • Statistical Data Analysis ( Customizable ) For Average, Min., Max, Diurnal Variation. Auto Report And, Auto Mail Generation Etc. • Comparison Of Parameters Of Different Locations In User Selectable Time Formats I.E. In Graphical And Tabular Formats Compatible To Ms. Excel, Ms Word, Txt Etc. Including Mandatory Fee For Data Transmission To Cpcb, Rspcb & Mcb Server ( Whenever Payable ) . • Ultrasonic Open Channel Flow Meter With Shall Comprise Of Flow Sensor / Transducer, Flow Transmitter, Digital Level Indicator / Remote Indicator. Control Unit • Operating Temperature: 0 To 50°C. Safety: Explosion Proof Or Intrinsically Safe. • Measuring Principal: Ultrasonic. • Communication Protocol: Open Protocol Like Modbus, Profibus, Hart, Etc. Analog Output: Isolated 4-20Ma, • Relay Contacts: Minimum Of 3 Spdt Contacts. • Accuracy: ± 0.25% Of Measured Value Or Better. • Output. 4-20 Ma • Protection A. ) Sensor: Ip-68. B. ) Transmitter / Controller: Ip-66 ( Nema 4X ) . • Display: Lcd With Led Backlighting 130 , 1 Kva Ups • Capacity -1000Va / 600W • Input Voltage Range 140 V 300 V Ac Frequency 50 Hz ± 10% • Operating Temperature 0°C-40°C; • Charging Time 6-8 Hours Recover To 90% Capacity Battery Rating Smf 12V / 7Ahx2 Batteries, • Output Voltage 230 V Ac Nominal Transfer Time Typical 4-8Ms • Type Sealed Maintenance Free , Comprehensive Operation & Maintenance Cost For Whole System For 2Nd Year Including Data Transmission To Cpcb, Rspcb & Mcb Website, Four Service Visits, Two Times Calibration Of System In A Year, Repairable Cost, Replacement Cost. Consumables Etc. , Comprehensive Operation B Maintenance Cost For Whole System For 3Th Year Including Data Transmission To Cpcb, Rspcb & Mcb Website, Four Service Visits, Two Times Calibration Of System In A Year. Repairable Cost, Replacement Cost, Consumables Etc. , Comprehensive Operation & Maintenance Cost For Whole System: For 4Th Year Including Data Transmission To Cpcb, Rspcb & Mcb Website, Four Service Visits, Two Times Calibration Of System In A Year. Repairable Cost, Replacement Cast, Consumables Etc. , Comprehensive Operation & Maintenance Cost For Whole System For 5 Year Including Data Transmission To Cpcb, Rspcb & Mcb Website, Four Service Visits, Two Times Calibration Of System In A Year, Repairable Cost, Replacement Cost, Consumables Etc.

Key Value

Document Fees
INR 2000 /-
EMD
INR 132780.0 /-
Tender Value
INR 66.39 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail