Tender For Spl Repairs To Bldg No P-7/8, P-9/8,P-7/5, Pron Of Rain Water Underground Drainage Near Mt Garage At Asc Saraibari And Provn Of Hard Standing With Paver Block, Provn Of 03Cattle Grid Atsaraibari Area Andprovn Of Parking Shed For Mescolon, jorhat-Assam

Military Engineer Services-MES has published Tender For Spl Repairs To Bldg No P-7/8, P-9/8,P-7/5, Pron Of Rain Water Underground Drainage Near Mt Garage At Asc Saraibari And Provn Of Hard Standing With Paver Block, Provn Of 03Cattle Grid Atsaraibari Area Andprovn Of Parking Shed For Mescolon. Submission Date for this Tender is 19-12-2022. Building Work Tenders in jorhat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

34939786
Corrigendum : Tender For Spl Repairs To Bldg No P-7/8, P-9/8,P-7/5, Pron Of Rain Water Underground Drainage Near Mt Garage At Asc Saraibari And Provn Of Hard Standing With Paver Block, Provn Of 03Cattle Grid Atsaraibari Area Andprovn Of Parking Shed For Mescolon
Open Tender
Indian
Assam
jorhat
19-12-2022

Tender Details

Special Repairs To Bldg No P-7 / 8, P-9 / 8, P-7 / 5, Pron Of Rain Water Underground Drainage Near Mt Garage At Asc Saraibari And Provn Of Hard Standing With Paver Block, Provn Of 03Cattle Grid Atsaraibari Area Andprovn Of Parking Shed For Mescolony At Rowria

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 42.85 Lakhs /-

BOQ Items

Nature of Work:SPL REPAIRS TO BLDG NO P-7/8, P-9/8, P-7/5 (SR/BLDG-09/22-23), PRON OF RAIN WATER UNDERGROUND DRAINAGE NEAR MT GARAGE(MINOR-23/ 22-23) ATASC SARAIBARI AND PROVN OF HARD STANDING WITH PAVER BLOCK (RW-15/ 22-23), PROVN OF 03 CATTLE GRID (MINOR-15 / 22-23) ATSARAIBARI AREA AND PROVN OF PARKING SHED FOR MES COLONY AT ROWRIAH(MINOR-22 / 22-23) UNDER GE JORHAT.
Sl. No. Item Description
1NOTES :(i)The bidders/contractorsare advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
2Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil
3Excavating over area not exceeding 1.5 m deep and getting out in soft/loose soil.
4Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
5Excavation in postholes not exceeding 0.5 cumand gettingout andreturningfilling in, rammingearthin layers not exceeding 25 cm thick, wateringand removingsurplussoil to adistancenot exceeding 50m and makinggood in hard/dense soil.
6Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
7Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
8Material and labour for hard core of gauge not exceeding 63 mm of broken stone or boulders , spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surfacecomplete all as specified and as directed.
9Material and labour for Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
10Material and labour for Plain Cement Concrete M-10(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
11Material and labour for Reinforced Cement Concrete M-20 (Nominal mix) using 20 mm graded stone aggregate as in foundation & plinth beams complete all as specified and as directed.
12Use and Waste of formwork for foundations, foundationbeams etc. for rough finished surfaces of concretecomplete all as specified and as directed.
13Material and labour for high strength steel TMT bars (Fe 500D) 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.90 mm diacomplete all as specified and as directed.
14Material and labour for high strength steel TMT bars (Fe 500D) 6mm 78mm dia , cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.90 mm diacomplete all as specified and as directed.
15Material and labour for high strength steelTMT bars (Fe 500D) 6 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel (annealed) wire not less than 0.90 mm dia complete all as specified and as directed.
16Material and labour for Rolled mild hollow steel sections steel of grade YSt 310conform to IS 4923-1997 in roof trusses (framed), trussed, purlins, bracing and fasteningsincluding distance pieces, cleats etccomplete all as specified and as directed. Note:- The steel trussesshall beprovide as per TDno CESZ/STD/26.
17Material and labour for mild steel screw bolts (machine made) with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exceeding 22.5 cm and not exceeding 30 cm long, dia of neck 16 to 20 mm complete all as specified and as directed
18Material & labour of Mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410W (Gde- E- 250) quality- A complete all as specified and as directed
19Material and labour forpre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick and pitch length 75 mm c/c of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed.
20Material and labour forpre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, tips, valley, gutters, length & girth as fixed with nail or screwscomplete all as specified and as directed.
21Material and labour for Rolled mild steel in joist, channel, angle, or tee sections, fixed independetly, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated), Fe-290(Gde E-165) and including andone shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabricationcomplete all as specified and as directed
22Material and labour for compound girders and stanchions,lattice girders, aerial masts, staging for water tanks and the like including caps,bases,splices built up from two or more beam, channel sections or angles with plates, includingalliattibars,stiffeners, gusset plates conforming to Fe 41O-W (Grade -250 quality A)and including andone shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabricationcomplete all as specified and as directed
23Material and labour for old size Brick work with bricks class designation 75, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
24Cutting openings, through brick walls built in cement mortar for door, windowand other openings or enlarging existing openings. Converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. To store and rubbish not exc. 50m complete all as specified and as directed.
25Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
26Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level)
27Demolition of cement concrete (un-reinforced) in ground floors, sunken floor and paving complete all as specified
28Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the MOD premises complete all as specified and as directed.
29Plain Cement Concrete M-15(Nominal Mix) using 12.5 mm graded stone aggregate as inmaking goodwindow opening, lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones, bed plates, kerbs, water trough and the like including weathering slightly rounded or chamfered angles and throating as directed
30Material and labour for1 50 mm thick plain cement concrete M-10(nominal Mix) using 40 mm graded stone aggregate as in floor, fair finished complete all as specified and as directed.
31Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tileexceeding 0.06 Sqm and not exceeding 0.11Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bedlayer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0kg of cement per Sqm complete all as specified and as directed.
32Material & Labour of vitrified ceramic tiles,double charged, light coloured shade, 10 mm thick of square/rectangular area of each tile not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bedlayer in CM (1:4)complete all as specified and as directed.
33All as per item No ___ here-in-before but to vertical surfaces such as skirting over and including 10mm thick rendering in CM (1:3) complete
34Material & Labour Glazed ceramic tiles 400x300x7 mm(Coloured)on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
35Material & Labour of 18mm thick granite ( of any type) work ( table rubbed and polished in pillars and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust admixture of pigment to match with shade of granite over 15mm thick screed bedlayer in CM (1:4) including taking down existing one complete all as specified and as directed.
36All as per item No 35 here-in-before but to vertical surfaces such as skirting over and including 10mm thick rendering in CM (1:3) complete
37Material ,Labourand laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever complete all as specified and as directed..
38Material ,Labourand laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sandcomplete all as specified and as directed..
39Materials and labour for sunken floor water proofing treatment of various layers from bottom to top on all surfaces of slab in followingsequence and including demolition and removal of existing surfaces complete all as specified and as directed. (i) Slope correction by using M-20 (Nominal mix) concrete by using 12.5mm graded stone aggregate with integral water proofing compound ( minimum 2%), finished even and smooth using extra cement all as specified and as directed. (ii) Application two coats of elastomeric cementitious water proofing on sunken wall & floor surface as per the manufacturers instruction (iii) Concrete for sunken slabs shall be mixed with WP compound as per manufacturers Instructions.(To be measured separately) (iv) Joint ofTrap/WC/Soil pipes shall be properly sealed with sealing compound(if required) (v) Testing of all traps & joints and sunken slab shall be as per IS-1742 before filling of sunken slabs, including smoke tests. (vi)25 mm outer diaof CPVC pipe spout pipe of 600 mm length Note:- This item shall be measurein length & breath of floor area and paid accordingly.
40Material & Labour for Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in mass concrete in sunken floor complete all as specified and as directed.
41Material & Labour for Continuous brick edging using bricks class designation 75, old size with width equal to depth of the brick laid on ends verticallycomplete all as specified and as directed.
42Taking down cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removaloutside of MOD land complete all as specified and as directed.
43Rendering 15 mm in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces finished even smooth withoutusing extra cement to the plastered surfacecomplete all as specified and as directed.
44Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finishedeven and smooth withoutusing extra cement, with water proofing treatment. Note:- Water proofing compound shall be measure and paidseparately
45Material and labour for Rendering 15 mm in Cement Mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth using extra cementcomplete all as specified and as directed.
46Rendering 5 mm in Cement Mortar 1:3 on fair faces of brick work or concrete ceiling surfaces finished fair
47Supply only integral liquidwater proofing compound
48Material and labour for Preparation of new surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.5 mm thick cement base wall putty complete all as specified and directed.
49Material and labour for completeremoval of existing finishing of internal ceiling surface of building/structure by mechanical appliance and preparation ofold surfaces and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of primer over a coat of 1.5 mm thick cement base wall putty complete all as specified and directed.
50Material and labour for completeremoval of existing finishing of internal wall surface of building/structure by mechanical appliance and preparation ofold surfaces and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of primer over a coat of 1.5 mm thick cement base wall putty complete all as specified and directed.
51Material and labour for Preparation of new surface and applying3 coats white wash on walls surface complete all as specified and as directed.
52Material and labour for preparation of old internal ceiling surfaces and applying a coats of white wash complete all as specified and directed.
53Material and labour for completeremoval of existing treatment of external wall surface of building/structure by mechanical appliance and preparation ofold surfaces applying two coats of acrylic exteriorweather resistant paint(weather proof paint @ 1.67 ltr/10 sqmper two coats ) of required colour shade and as per manufacturer’s specification over a coat of acrylic exterior primer((@ 2.20 kg/10 sqm) complete all as specified and directed.
54Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and as directed.
55Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. not exceeding 1.50 Sqm each complete all as specified and as directed.
56Supply and fixing of pressed steel door frames (fabricated out of CRLCS sheet 1.6 mmthickness) 165 x 60 mm size with one or more rebates including necessary fixing lugs, hinges, lock striking plate etc. complete all as specified and as directed.
57Supply and fixing of pressed steel door frames (fabricated out of CRLCS sheet 1.6 mmthickness) 125 x 60 mm size with one or more rebates including necessary fixing lugs, hinges, lock striking plate etc. complete all as specified and as directed.
58Material and labour for 35 mm thick, second class hard wood, factory made glazed and skeletonshutters, open rebated and prepared to receivegauze, etc.with plain chamfered or rounded, mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
59Supply and fixing of 35 mm thick flush shutters, solid core construction, with block board core and comercialplywood face panels with one face is covered with decorative face veneer with lipping/frame to match all complete all as specified and as directed.
60Material and labour for Solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with Mild Steel square tube, suppling & fixing in opening as per drawing complete all as specified and directed.
61Material and labour for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawingcomplete all as specified and directed.
62Material and labour for mild steel work as in bands, straps, supports or stays for RWP, ventilating pipes, clamps, hold fasts, wall ties conforming to Fe-290 Gde E-165
63Material and labour for Butt hinges Stainless steel100 mm size complete all as specified and directed.
64Material and labour for Aluminium anodised barrel tower bolts of extruded section size 300 mm complete all as specified and directed.
65Material and labour for Floor door stopper of SS body and tongue, anodised, with hard drawn steel spring of size 150 mm, fixed in floor complete all as specified and directed.
66Material and labour for Aluminium handles cast type anodised 75mm size complete all as specified and directed.
67Material and labour for Aluminium handles cast type anodised 100 mm size complete all as specified and directed.
68Supply and fixin ofofstainless steel telescopic ball bearing drawer channel of size 450mm x 46mm x 12.7mm, width of flap 30mm for drawar. complete all as specified
69Supply and fixing ofpowder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standardtubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
70Supply and fixing ofpowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
71Supply and fixing ofaluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum thickness of powder coating 50 micron) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge.
72Materials and labour for Mild Steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe-290(Gde E-165)complete all as specified and as directedincluding taking dwon old one complete all as specified and as directed.
73Material and labour for Stainless steel wire cloth, 0.43 mm nominal dia of wire and avergae width of aperture 1.00 mm and fixed with stainless steel wire staples complete all as specified and directed.
74Supply and fixing in repairsof figured glass with sheet glass 4 mm thick , pin head type and glazing with oil putty in squares n exc 0.5 sq. M in each panecomplete all as specified and as directed.
75Supply and fixingof sheet glass 4 mm thick ordinary quality fixed to aluminum door & window in squares in each pane of required size complete all as specified and as directed.
76Material and labour for preparation of new steelsurface and applying two coats of black bituminous paint over a coat of red oxide primer on new steel and iron surfaces of any description over exceeding 10 cm in width or girthcomplete all as specified and as directed..
77Material and labour for preparation of new wall plaster surface and applying two coats of synthetic enamel paint over a coat ofprimer on new wall surfaces of any description over exceeding 10 cm in width or girthcomplete all as specified and as directed..
78Material and labour for preparation of new steelsurface and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description over exceeding 10 cm in width or girthcomplete all as specified and as directed..
79Material and labour for preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat of pink primer on new woodensurfaces of any description over exceeding 10 cm in width or girthcomplete all as specified and as directed..
80Material, labour and fixed of aluminium snap grid frame work for false ceiling, size of grid 605 x 605 mm, including aluminium main/closs tee ofsize 35mm x 23mm x 1.5 mm ( minimum)aluminum BULBED TEES section and aluminium angle of 25mm X 25mm X1.5mm thick, sutiable type GI wire hanging arrangement with adjuster all as specified inclause no 10.38 in SSR part-I and including 4mm thick high pressure steam cured non asbestos fibre cement designerboard as per IS 14862with applying oftwo coats of acrylic distemper over a coat of primerincluding taking dwon existing false ceiling system complete all as specified and directed.
81Stripping out tarfelt from old roof surfaces and removing unserviceable materials from site of work in low laying in outside MOD area complete all as specified and as directed.
82Material and labour forrendering 15 mm(Avg) thick in Cement Mortar 1:4finished even and smooth witht using extra cementafterpreparation of old roof surface with brushing and applied neat cement slurry with 3.0 Kg of cement per Square Metre existing surface complete all as specified and as directed
83Supplying and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt laying over a coat of bituminous primer @ 0.40 Ltr / Sqm and two coats of Bitumen based UV reflective paint with aluminium finish over APP membrane. The membrane shall be laid using butane torch and sealing all joints etc all as specified in Para 11.44.5 of SSR Part Icomplete all as specified and as directed.
84M& L for cutting existing GI pipes 40 mm dia for insertion of new Tee 40X40X25 mm incl Tee for branch connection complete all as specified and as directed.
85Supply and fixing of 15mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors complete all as specified and as directed.
86Supply and fixing of 20mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors complete all as specified and as directed.
87Supply and fixing of galvanised steel water tubing 20 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) and laid in trenches all as specified and as directed.
88Supply and fixing of galvanised steel water tubing 25 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) and laid in trenches all as specified and as directed.
89Material and labour for Gun metal gate valve with iron wheel head, screwed both ends for iron pipe of 20mm bore complete all as specified and as directe
90Supply and fixing in repair of bib cock cast copper alloy screwed down with long body with wall flange,and fixed for 15 mm bore GI tube pipe and all accessoriescomplete all as specified and as directed. complete all as specified. Make :- Cat no PIS -08 of Prayag or equivalent model of make list as given in PS as approved by GE.
91Supply and fixing in repair of chromium plated pillar cock cast copper alloy screwed down with long body with wall flange,and fixed for 15 mm bore GI tube pipe and all accessoriescomplete all as specified and as directed. complete all as specified. Make :- Cat noPIS 02 of Prayag or equivalent model of make list as given in PS as approved by GE.
92Supply and fixing in repair ofstop valve standard of PTMT any colour high pressure screwed for 15 mm bore diairon pipe and fixed .(Minimum weight 15mm-90gms)complete all as specified.
93Supply and fixing ofVitreous china wash down water closet (pedestal pattern) with concealed S-trap or P-Trap, white, 390 mm high, seatcoverincluding connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etcand including taking down existing one complete all as specified and as directed Mak:-SLICK of HINWARE or equivalent model of make list as given in PS as approved by GE."
94Supply and fixingof vitreous china wash basin white flat back, size 550 x 400 mm includingCP waste coupling,with GI pipe brackets & , rag bolt in cement concrete/brick wall and including taking down existing HWB and making good wall surface complete all as specified and as directed. Make: Cat no S2040103 wash basin of CERA or equivalent model of make list as given in PS as approved by GE.
95Supply and fixing as in repair of PVC low level flusing cistern 10 litres capacity white with ball valve & brackets with flush pipe complete all as specified and as directed. Make: CHIVAS of CERA or equivalent model of make list as given in PS as approved by GE.
96Supply and fixing as in repair of PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
97Supply and fixing in repair offancy type chromium plated Health Faucet of cast copper alloy, chromium plated, screwed for iron pipe, and fixed suitable for 15 mm bore of pipe complete all as specified and as directed.
98Material and labour for 600 x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood complete all as specified and as directe
99Supply and fixing of uPVC oftype-B for use in soil and waste discharge systems, single socket, 110 mm bore in any length including rubber ring joints and fixed to walls with clips and other standard materialand including taking dwon oldrain water pipe & removal from siteall as specified in IS 13592complete all as specified and directed.
100All as per item no 75 above but75mm borecomplete all as specified and directed.
101Supply and fixing of Unplasticized (uPVC )bendfor 110 mm bore uPVC pipe complete all as specified and directed.
102Supply and fixing of Unplasticized (uPVC )bendfor 75 mm bore uPVC pipe complete all as specified and directed.
103Supply and fixing of PVC(SWR) vent cowl, 110 mm bore
104Supply and fixing of PVC (SWR) floor trap, plain with grating including jointing with solvent cement, 75 mm dia of outlet.
105Material and labour for Reinforced Cement Concrete pipe of 300 mm dia class NP-2 laid and jointed with collars and tested complete all as specified and directed.
106Material, labour for high strength steel deformed TMT bars 10 mm dia and over, cut to length, bent to shape required includinghooking ends for straining chain link fencing and fixed on fencing postcomplete all as specified and as directed
107Supply and fixing of chain Link3 mm dia , 75mm x75mm mesh size of mild steel galvanized fencingand minimum weight 2.1 Kg per Sqm and including fixed with straining bolts incl provision of binding wire etccomplete all as specified and as directed.
108Supply and fixing Hard drawn steel wire fabric (weight exceeding 4 Kg per Sqm) cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.90 mm in dia supplied and fixed in reinforcement complete all as specified and as directe
109Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scales, dirt etc. from the tank and from mouths of circulating pipes etc., exceeding 500 litres but not exceeding 1000 litres capacity complete all as specified and as directe
110Subtotal of Sch A part-I
111SCHEDULE "A" PART - II FOR E/M PORTION (Sl No __ to ____)
112Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
113Material and labour forpoint wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for one light/fan point controlled by one switch completeall as specified andas directed.
114Material and labour forPoint wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 6 amps on independent board completeall as specified andas directed.
115Material and labour forPoint wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSH copper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly for one 5 amps socket outlet on same board with other switchcompleteall as specified andas directed.
116Materials and Labour for Point wiring with 4.00 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 4.0 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 16 amps on independent board completeall as specified andas directed. NOTES FOR ITEM NO113 to 116:- Flush steel terminal box, inner plate and front plates shall be measured and paid seperately.
117Material and labour for Metal flush box 1 modular completeall as specified andas directed.
118Material and labour for Metal flush box 2 modular completeall as specified andas directed.
119Material and labour for Metal flush box 3 modular completeall as specified andas directed.
120Material and labour for Metal flush box 4 modular completeall as specified andas directed.
121Material and labour for Metal flush box 6 modular completeall as specified andas directed.
122Material and labour for Metal flush box 8 modular completeall as specified andas directed.
123Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 1 modular completeall as specified andas directed.
124Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 2 modular completeall as specified andas directed.
125Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 3 modular completeall as specified andas directed.
126Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 4 modular completeall as specified andas directed.
127Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 6 modular completeall as specified andas directed.
128Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 8 modular completeall as specified andas directed.
129Material and labour for Modular switch 6 Amp single pole one way completeall as specified andas directed.
130Material and labour for Modular switch 16 Amp single pole one way completeall as specified andas directed.
131Material and labour for Modular socket 16/6 Amp 3 pin combined shattered completeall as specified andas directed.
132Material and labour for Modular socket 6 Amp 2/3 pin combined shattered completeall as specified andas directed.
133Material and labour for ModularElectronic type fan regulator step type 120 watt, 230 volt completeall as specified andas directed.
134Supply and fixingin repair of bell multi music type AC, 230 volts complete all as specified and as directed.
135Supply and fixing in repairmodular type bell push flush type 5 Ampscompleteall as specified andas directed.
136Material and labour for Blanking plate SP with incoming contact completeall as specified andas directed.
137Supply and fixingceiling rose surface bakelite 65x50mm three terminalscomplete all as specified and as directed.
138Supply and fixing of LED surface/ceiling mounting(suspended fromceiling) box type light fitting20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover& highpower LED’s as light sourcewith 120Lumen perwatt (Minimum) andincluding all other standard accessories as per manufacture instructions ,internally pre-wired including connecting upthree core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CCS-100-20-65-HL2-DP-NWH ofCrompton/ BCLAB 20W WH LED P of Bajaj or equivalent model of make list as given in PS as approved by GE.
139Supply and fixing of LED surface/ceiling mounting(suspended fromceiling) box type light fitting10Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover& highpower LED’s as light sourcewith 110 Lumen perwatt (Minimum) andincluding all other standard accessories as per manufacture instructions ,internally pre-wired including connecting upthree core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model NoCCS-103-10-65-SL-DP-NWH of Crompton or equivalent model of make list as given in PS as approved by GE.
140Supply & Fixing ofLED street light fitting ( Building Security light) of 35Watt with LED lamp’s & driver and made ofpressure die-cast aluminum housing,IP 65/IP 66roadwayluminaries withUV stabilized polycarbonate coveror toughen glasscover& highpower LED’s as light sourcewith 110 Lumen perwatt andelectronic driverwithefficiency >85% . The light fittingshall be fixed on wall/pole with and including 25 mm dia( or higher size as per manufacturers recommendation)light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr longcomplete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primerand including taking up old light fitting complete all as specified and as directed Make:- Model No- TRP-400-35-57-SL-LM-NSR of Crompton Greave/ NXT P 36L WH CR PC SD of Bajaj or equivalent model of make list as given in PS. Notes : GI pipe bracket and clamps shall be deem to be included above quoted rate..
141Supply and fixingof sub main wiring with two single core 6.0sqmm (nominal area) PVC insulated copper conductorFRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping andaccessoriesaccessoriesincluding one single core 6.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
142Supply and fixingofsheet metal enclosure for MCBs to be used triple pole & nutral double door 4 Way 200 Amps rated busbarand including fixed with 25mm x 6 mm mild steel clamp of suitable lengthand including taking out old DB complete all as specified and as directed.
143Supply and fixingofsheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbarand including fixed with 25mm x 6 mm mild steel clamp of suitable lengthand including taking out old DB complete all as specified and as directed.
144Supply and fixingof MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
145Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacity.
146Supply and fixing MCB four pole 40 to 63 amps 415 volts 10KA breaking capacity.
147aterial & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit inPCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed
148Material and labourfor lamp holder insulated body with back plate for batten fittings with 10 Watt LED lamps complete all as directed
149Material and labourfor Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
150Material and labourforlaying of Class designation 75 bricks, old size, flat, common clay laid in trenches across the trench as cable protection complete all as specified and directed.
151Material and labourforlaying ofLT XLPE insulatedarmoured heavy duty cable 1100 voltgrade ISI markedwith alumimium conductor multi strandcrosssectional area 70 Sqmm x 3.5 Core complete all as specified and directed.
152Material and labourforlaying ofLT XLPE insulatedarmoured heavy duty cable 1100 voltgrade ISI markedwith alumimium conductor multi strandcrosssectional area 35 Sqmm x 3.5Core complete all as specified and directed.
153Supply and layingof 40mm bore galvanised steel tubes, light grade for cable protection complete all as specified and as directed.
154Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 25x4mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit inPCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layercomplete all as specified and directed .
155Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC-M10 using 20 mm graded stone aggregateincludingbus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply systemincluding disconnecting of electricconnection both incoming & out goingfrom existing unsv indoor/outdoor feeder pillar boxes/busbar enclosers and unsv accessoriesand taking out panelfrom the foundation . The panel board shall comprise of following items & all specified in SSR Part-I clause no 19.21 and all as shown on drawing .
156(A) INCOMING:- (i)MCCB 80 amps, 4 pole, breaking capacity 16KA suitable for operation of 415 volts AC 50 HZ- 01 No, (ii)4 strip tined coated copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear or not less than 200 Amp whichever higher (iii)Digital Ammeter, 0-400 Amps,with 3 Nos CT and 4 Position selector switch-1 Set , (iv)Digital Voltmeter 0-500 Volts with 4 Position selector switch - 1 set , (v) LED Type indicator lamp R-Y-B(1 Set), (v) 4 strip aluminum coated copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear or not less than 200 Amp whichever higher (B) OUTGOING (i) MCCB 40 Amp, 3 Pole, 415 Volts, 16 KA - 01 No, (ii)MCB 6-32 A, 2 Pole, 240Volts, 10 KA - 03 No,(iv) space for one MCCB
157Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ?___________mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail