| 1 | Demolishing brick work in cement mortar up to floor V level including stacking of serviceable material and disposal of unserviceable material within the campus as per directions of EIC |
| 2 | Dismantling of existing wooden fixed work stations including stacking of serviceable material and disposal of unserviceable material as directed with all leads complete |
| 3 | Brick work with FPS bricks of class designation 75 in super structure up to all floors.In cement mortar 1cement: 6 fine sand mortar |
| 4 | 15mm thick cement plaster on brick/ concrete wall of mix 1:4 (1 Cement: 4 Coarse Sand) |
| 5 | PLASTIC EMULSION PAINTPainting two or more coats with Dulux paint of Spectrum/ Nerolac or equivalent make and approved shade on internal walls and ceilings as required to give an even shade including preparing the surface, applying primer coats etc complete all to the satisfaction of EIC |
| 6 | Providing and fixing of MDF panelling 8mm thick fixed in panels of approved make and design over 12mm ply fixed over wall including all related accessories like corner/ top flashing etc complete including cost of mat finish paint, screws all complete as per the directions of EIC |
| 7 | GYPSUM FALSE CEILING : - Providing & fixing suspended false ceiling using 12.5mm thick Indian gypsum boards confirming to IS 2095-1982 and GI framework of Gyp steel or approved equivalent comprising of following. 1.GI perimeter channel of 0.55mm thick having one flange of 20mm, another of 30mm and web of 27mm fixed to brick wall partition along periphery of ceiling with the help of nylon sleeves and screws at 610mm c/c 2.GI intermediate channel ( size, 45mm web, two flanges each of 15mm & thickness 0.9mm ) suspendedfrom the soffit / ceiling at 1200mm c/ c spacing. 3.GI ceiling sections of 0.55mm thick having knurled web of 51.5mm and two flanges each of 26mm with leaves of 10.5mm fixed to intermediate channel with the help of connecting clip at direction perpendicular to the intermediate channel at spacing of 600 mm c/c, . GI suspender angle of 25mmx10mm and thk.0.55mm at spacing of 600mm c/c, fixed to the ceiling / soffit using GI cleat angle 25mm x 25mm, 0.55mm thk. Cleat angle to be fixed to the ceiling / soffit using6mm dia anchor fastener. Gypsum board to Be finished with Jointing tape and Jointing compound including application of One coat primer as Per Gypsum board Manufactuerer specification. The rate quoted shall include making cut outs for fixinglight fittings, grills, diffusers, speakers, smoke detectors, sprinklers etc.Cut outs have to be made with provision of the frame along perimeter of the cut outs/ opening with channels/ ply to support the ceiling adequately. No extra payment shall be made for making cut outs. |
| 8 | Acoustic Grid CeilingProviding and fixing Mineral Fibre Board modular Ceilingmanufactuered byUSG / Armstrong / Saint Gobain India Ltd or equivalent make as approved by Architect in Tegular edge Mineral textured tiles with approved surface pattern of size 600mm X 600mm x 15 mmhavingNoise reduction Co-efficient 0.6 light reflection over 75%, Relative Humidity 95%, Suspension system of Silhouette reveal profile grid system with 15mm wide flanges incorporating a 3 or 6 mm central recess of colour all white or all black or white with black as directed, Silhouette main runners and cross tees to have mitred ends and \"birds mouth\" notches to provide mitred cruciform junction, fixed to the structural soffit by Butterfly clip hangers, suspension wires & anchor fasteners as per the manufacturer\"s specification, Suspension wires to be provided at every 600mmm c/c with two nos of ties on each anchor fastener, Perimeter trim of Trulok wall angle in white colour secured to wall at 450mm maximum centres. The rate quoted shall include making cut outs for fixinglight fittings, grills, diffusers, speakers, smoke detectors, sprinklers etc.Cut outs have to be made with provision of the frame along perimeter of the cut outs/ opening with channels/ ply to support the ceiling adequately. No extra payment shall be made for making cut outs. |
| 9 | Providing and fixing of PVC panelling/ lining of 6mm (net thickness) and fixed over steel channels of required size and thickness including cost of beading, edge provides, screws, plugs etc complete as per directuons of EIC |
| 10 | Painting with synthetic enamel paint of approved brand and manufacture to given an even shade two or more coats on new/ old wood work including sand papering and knotting including priming coat |
| 11 | Providing and laying in position cement concrete (1:2:4) in RCC for all types of structures including proper vibration and curing including broom finish if required but excluding cost of formwork and reinforcement etc all complete as per drawing, specification and direction of EIC. AGL |
| 12 | Providing and fixing to correct level, line plumb, vertical, plain formwork with contractor\"s own material in all shapes made of plywood/ms sheets for RCC/PCC works including necessary strutting, scaffolding, bracing etc. Leaving necessary recesses, opening chamfers etc. Keeping the same in position during concreting and removing after the specified period, all complete as per specification and direction of EIC. for work above FGL |
| 13 | Granite FlooringProviding and laying flooring using 18mm thick N-Green type Granite of approved size, pattern laid over 20mm thick bed with tile grouting for flooring, using adhesive/ chemical slurry below slabs for packing as per architectural design, drawing and specifications, including joint filling with approved quality and colour cement to match the shade of Granite. The work shall include cost of materials, wastage, labour, all lead and lift at all levels, loading and unloading, transportation, cutting, curing etc and all other incidental charges etc complete and as directed by EIC |
| 14 | DOORSSOLID LAMINATE WATER PROOF DOOR SINGLE LEAF WITH ALUMINUM FRAMEProviding & fixing of 45mm thick Solid Laminated door (total built up 47mm) with single shutter as per details. * The door shutter shall consist of 45mm thick solid cored water proof flush panel. * The frame shall be including. * The door shall be finished on both sides with 1.0mm thick laminate of approved shade cladded with grooved as per design.* 2mm thick teak wood lipping to be provided alround the shutter finished with melamine poilsh or paint as directed by EIC. * The rate shall include 8mm thick clear glass of specified size and shape (vision panel) with necessary deep etching/bevelling complete as per design and drawing and as directed by EIC. * Grooves to be filled with epoxy based bal grout of matching / contrast shade. *Provided both side SS kick plate 900X300X2mm thick* Provided with four no. 100mm SS hindges.All complete, with necessary accessories like door lock with handle , door stopper, concealed door closer etc complete of Dorma or equivalent make. |
| 15 | Note. The quoted percentage (%age) should preferably be in fractional form in order to minimize concurrence of similar quoted rates |