Tender For Comprehensive Maintenance Of Main And Standby Power System, Precision Cooling, Fire Suppression System And Allied Accessories For Project Vyoma At 1 Wec And Repair Maintenance Of Internal Electrification Misc Works 1 Wec Under Ge (U) P&M Delhi , delhi-Delhi

Military Engineer Services-MES has published Tender For Comprehensive Maintenance Of Main And Standby Power System, Precision Cooling, Fire Suppression System And Allied Accessories For Project Vyoma At 1 Wec And Repair Maintenance Of Internal Electrification Misc Works 1 Wec Under Ge (U) P&M Delhi . Submission Date for this Tender is 30-11-2022. Fire Suppression System Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

34736499
Tender For Comprehensive Maintenance Of Main And Standby Power System, Precision Cooling, Fire Suppression System And Allied Accessories For Project Vyoma At 1 Wec And Repair Maintenance Of Internal Electrification Misc Works 1 Wec Under Ge (U) P&M Delhi
Open Tender
Indian
Delhi
delhi
30-11-2022

Tender Details

Tender For Comprehensive Maintenance Of Main And Standby Power System, Precision Cooling, Fire Suppression System And Allied Accessories For Project Vyoma At 1 Wec And Repair Maintenance Of Internal Electrification Misc Works 1 Wec Under Ge ( U ) P&M Delhi Cantt-10.

Key Value

Document Fees
INR 500 /-
EMD
INR 82940.0 /-
Tender Value
INR 41.47 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVE MAINTENANCE OF MAIN AND STANDBY POWER SYSTEM, PRECISION COOLING, FIRE SUPPRESSION SYSTEM AND ALLIED ACCESSORIES FOR PROJECT VYOMA AT 1 WEC AND REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION MISC WORKS 1 WEC UNDER GE (U) P&M DELHI CANTT-10.
Sl. No. Item Description
1Periodical, preventive and comprehensive maintenance to Integrated Data Centre Solution/IT Racks (02 Nos) suitable for 35 KW IT load distributed in 4 Racks which provide active approx 165 U space for IT devices of OEM VERTIV and consisting of the following :- (i) Precision Air Conditioning (04 Nos):- Direct Expansion microprocessor based precision AC units (Para metric cooling CFM) of min 35 KW sensible capacity precision AC unit with air cooled condenser, digita scroll compressor in each unit with suitable refrigerant circuits, evaporator coil with hydrophilic coating, direct driven electronic thermostatic expansion valve suitable for environment friendly R410A refrigerant, electric heater locking disconnect switch, adjustable modular baffle system, heater, clocked filter, 2 Nos rack sensors, Infraredhumidifiers and vibration isolator.The unit refrigerant circuit has factory installed solenoid valve and service valves. Motor is suitable for 415V + 10%, 50cycles, 3 phase AC supply with EC fan and external static pressure 20 Pa.Smart row capacity modulated cooling, which is self contained precision cooling unit designed for cooling racks.
2(ii) Fire Detection and Suppression system:- Fire detection, fire suppression, smoke detection, NOVEC 1230 gas for fire suppression.The accessories are compressionof:- Seamless cylinger with pressure guage & low pressure switch fillable with NOVEC 1230 gas - 02 Nos. Electrical solenoid 24V DC stackable – 2 Nos. Manual & pneumatic actuator – 2 Nos. Discharge Hose – 2 Nos. 360-180 deg ceiling type discharge nozzle – 6 Nos. Cylinder strap – 2 Nos. 2 zone fire alarm panel with single zone gas release panel – 2 Nos. Release switch – 2 Nos. Abort switch – 2 Nos. MS Seamless pipes as per ASTMA with necessary fittings – 2 Lot. Smoke detectors photoelectric type 24V DC – 12 Nos. Warning plates – 2 Nos. Hooter cum strobe – 2 Nos. (iii) Remote display unit (RDU). (iv) Power distribution unit (PDU). (v) Camera surveillance and recording system. (vi) Event alerts system. (vii) Biometric Access Control system. (vii) Rodent repellent system. (viii) Temperature monitoring system. (ix) Humidity monitoring system. (x) Water leak detection system.
3Microprocessor/DSP controlled modular UPS of capacity 150 KVA (30 KVA Modules X 5 Numbers ) UPS Rack to be Scalable upto minimum 300 KVA and comprising IGBT based rectifier inverter to achieve input THDI<3% and input power factor >.99 at 100 % loading. The UPS frame having the space to scale 100% of the rated output and option to be paralleled with another frame if required in future. True online double conversion (VFI as per IEC 62040-3) UPS using PMW IGBT technology, 3 Phase input and 3 Phase 400 V output UPS system of OEM VERTIV complete all as specified and as directed and each comprising of the following:- (i) Fully rated, unity power factor designed user replacecable Rectifier, charger & inverter unit integrated in each power module, 5 Nos of 30 KVA power module to be integrated to achieve 150 KVA/KW connected load. (ii) Module should be redundent & Controller should also be redundent. (iii) 100% rated static bypass module at the bypass line. The static bypass module should be rated equivalent to the total power ratings of the power modules. (iv) Web-enabled monitoring and management through SNMP protocol for multi-OS environments. (v) UPS efficiency upto 95% at full load. (vi) High performance battery module comprising of lead acid sealed maintenance free batteries of capacity 12 Volts, 200 AH - 40 Nos,for providing 15 minutes backup to 150 KVA connected float. (vii) Health monitoring of battery back up.
4Periodical, preventive and comprehensive maintenance to VRV/VRF (Variable Refrigerant Volume/ Variable Refrigerant Flow) Air Conditioners of modular system type, with number of indoor connected to centrally located outdoor units as per OEM (DAIKIN) instructions. (a) Outdoor Units :- VRV/VRF outdoor units with multiple compressors complete with inverter based type Rotary/Scroll compressors, R 410A refrigerant, cooling & heating mode both options, special pre-coated fin type heat exchanger, low noise direct driven propeller condenser fans in each module with top discharge every module having minimum 02 Nos. fans, GI coated condenser stand, microprocessor panel with sequential staring of condensing unit, coils, expansion valves, filters in refrigerant circuits, single phase preventor, all vibration isolators, safeties, operation range of dry Bulb Temperature -5 of 49 Deg C (i.e. in cooling mode) and -20 to 15.5 Wet Bulb Temperature Deg C (I.E. in heating mode) with Minimum capacity control of 8% of ODU capacity. Each system had the provision to combine maximum 3 Nos. single outdoor unit, Every single outdoor unit had multiple compressors Minimum 2 and maximum 3 Nos. in single module of system. Level Difference of piping is 50 Mtr if DODU is above or below from IDU in both cases. Make- Daikin. (a) 18 HP Outdoor unit VRV/VRF System. (b) 14 HP Outdoor unit VRV/VRF System. (c) Indoor Units :- Ceiling Mounted Cassette type Indoor Units with inbuilt drain pump & decorative panels and having dimensions 900x900 mm complete all as specified and directed be Engineer-in-Charge for the following capacities :- (i)2 TR round flow type cassette unit with remote controls- 02 Nos. (ii)2.65 TR round flow type cassette unit with remote controls - 01 Nos. (iii)3.3 TRround flow type cassette unit with remote controls- 02 Nos. (iv)4.0 TR round flow type cassette unit with remote controls - 02 Nos. (v)2.0 TR 2 Way Ceiling mounted Ductable type unit- 04 Nos.
5Periodical, preventive and comphrensive maintenance to Microprocessor based 2 wire fault tolerant loop, 1 loop (each loop accessing minimum 99 detectors and 99 modules) fire alarm/detection control panel.The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes.Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is trigged.The panel shall have rectifier, loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output complete in all respects.The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2x12 volt SMF lead acid batteries capable of running for a minimum of 8 hours with battery charger complete as required and as per specification alongwith the following accessories :- Make of Control panel - Honeywell/GST/GE/Siemens. (a)Photo electric addressable smoke detector with standard base - 24 Nos. Make - Honeywell/GST/GE/Siemens. (b)Photo electric addressable heat detector with standad base - 01 Nos. Make - Honeywell/GST/GE/Siemens. (c)Photo electric addressable multi detector with standard base - 03 Nos. Make - Honeywell. (d) Fault isolator base - 03 Nos. Make - Honeywell. (e) Addressable manual push button to initiate audio alarm with a breakable glass cover/resettable, intelligent addressable type - 03 Nos. Make - Honeywell. (f)Fire Alarm Hooter, conventional, (sound output of minimum 90 dB upto a distance of 10 feet) with strobe light of minimum 75 cd intensity with power supply arrangement - 02 Nos.Make - GST.
6NOTE FOR ITEM NOS. 1 to 4:- (a) The comprehensive maintanance of equipment under this contract shall be done through respective OEM i.e. VERTIV and DAIKIN. The contractor will have to submit MoU on stamp paper of Rs. 100/- duly notarized as per performa (on serial page No. 119 to 121) within fifteen days from date of Accptance of tender, failing which the contract will be liable to be cancelled and work will executed as per policy invouge of the contractors default. (b) The contractor should submit the monthly test report of Equipment conducted by the OEM with in first week of every month to the Engr-in-Charge, failing which recovery of Rs. 2000/- per Equipment per month shall be deducted from contractors dues.
7Supply and fillingrefrigerant gas R-410A in Precsion AC/ VRV units complete in satisfactory working condition complete all as specified & as directed.
8M & L for detecting the leakage of gas and rectifying the defect to stop the leakage by gas welding or by any other means including cutting & brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
9Supply & fixing MCCB 3 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 KA with spreader terminals including taking down old unserviceable onecomplete all as specified & as directed.(Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
10Supply & fixing MCCB 3 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 10 KA with spreader terminals including taking down old unserviceable one complete all as specified & as directed.(Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
11Inspection, checking, cleaning, testing and commissioning of fire alarm cum fire detection system complete including fire detectors, smoke detectors, heat detectors, response indicators, wiring etc. through trained/experianced technician of OEM, the system and carry out planned maintenance in systematic and controlled manner building complete except new server room complete all as specified & as directed. (a) Fire Alarm control panel:- These shall be kept clean by checking for its controls, indicating equipment’s system and all operations/fault indicators including checking of panel circuits for its healthiness and including of healthy battery/UPS/battery charger system. (b) Smoke Detectors &Fire Detectors: - All smoke/fire detectors shall be removing dust/dirt accumulated on them due to local ambient conditions. These shall be tested & cleaned once in a quarterly and report shall be maintained as directed by Engineer-in-Charge duly signed by user and concerned JE/Engineer-in-charge. (c)Response Indicators, Manual Call Point and Hooter:All items which are installed inside a cabin, room or above ceiling shall be tested by actuating the particular detectors every quarterly so as to ensure proper functioning of indicator. (d) Wiring and cables:Complete wiring shall be inspected jointly by contractor, MES rep and users so that structure or occupancy changes doesn"t damage the cable/wiring/trigger device (Manual call points smoke heat ionization detector etc) (e) The contractor deemed to have visited the site and seen the scope of work before quoting the rates. (f) Quarterly maintenance (testing of all smoke detector and hooters shall be included) and its report shall be submit by the contracor to the Engineer-in-Charge. Test report shall be submitted to deptt duly signed by user. (m) Mock drill will be conducted once in quarterlyin presence of user after completion of cleaning and testing.
12Supply, fixing, commissioning and testing of automatic Floating Sensitivity type photo electric addressable thermal smoke detector with mounting based LED, Address Switch from 01-159 , to programme the detectors, complete as required. (In Changing Environment Area) ul- 7th editionincluding taking down old unserviceable one complete all as specified & as directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
13Supply, fixing, commissioning and testing of photo electric addressable thermal heat detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Ul- 7th editionincluding taking down old unserviceable one complete all as specified & as directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
14Supply, fixing, commissioning and testing of photo electric addressable thermal multi detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Ul- 7th editionincluding taking down old unserviceable one complete all as specified & as directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
15Supply,fixing,testing and commissioning of addressable type fault for isolating module shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model)including taking down old unserviceable one complete all as specified & as directed. (Make: - NOTIFIER GST/APPOLO/ EDWARD/HONYWELL).
16Supply and fixing of Strobe Lights Cum Hooter with 110 cd. The strobes shall be synchronized for better evacuationincluding taking down old unserviceable one complete all as specified & as directed. (Make:- NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
17Supply and fixing of addressable manual push botton to initiate audio alarm with breakable glass cover call pointincluding taking down old unserviceable one complete all as specified & as directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
18Material and labour for maintenance of feeder pillar/LT panel indoor/outdoor type including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends fresh and supply and crimping new thimbles/lugs and fixing the cable on bus bar/MCCB/Main switch/MCB including providing new nut bolts and washer if required greasing the doors of feeder pillar/LT panel outdoor/indoor type complete all as specified & as directed.
19M&L in repair pipe earthing (PIP) comprising of GI 50mm borepipe, wall thickness of pipe 4.85 mm (Medium grade), 3.00 Metre length, terminal size 40x6mm & internal strip 25x4mmwith one bag of BFC (50 Kg) as per IS 3043-1987, tubing filled with jelly earthing compound, duly inserted in soil, boring of 100mm bore filled with back filled compound including fibre chamber cover 1x1 feet, openable type, including testing of earthing complete all as specified and as directed. Note: On testing after completion, if the earth resistance < 1 Ohms is not obtain, earthing shall be rejuvenated at no extra cost till the desired earth resistance is obtained.
20Disconnecting and taking down faulty and defective Servo Voltage Stablizers of capacity 150 KVA , 418 Volts and opening the top cover of the servo stablizer, carrying out the repairs /works listed at serial No. (i) to (xii) for installation including making all the electrical connections complete all as specified and as directed. (i)Decanting of the Servo Volatge Stablizer oil (Transformer Oil)into separate Container /barrel. (ii)Taking out the core/coil of Stablizer (iii)Painting outside body with synthetic enamel paint of existing tint/colour and Cleaning inside of the Stablizer using Stablizer oil. (iv)Fixing only the existing/new buck boost transformer & Dimmer (Variable Transformer) in Stablizer including heating up the core assembly to remove moisture after carrying out the repair works . (v) Renewal of rubberised gasket set for top cover, Brass spindles, LT bushes, etc. (vi)Filling of new Stablizer oil after centrifuging and testing for requird di-electric strength. (vii)Re-fixing the top cover of the stablizer with nuts, bolts and washers. (viii) Preparing Inspection report for renewal of parts etc in presence of EIC and Contractor. (ix)The contractor shall arrange factory visit for the EIC or his representative as and when requried, testing of stablizer to be done on full load at factory. (x) Soldering/ brazing or connecting LV bus bars with sutable size nuts, bolts and washers (xi)Providing necessary insulation papers, sleeves, PVC pipes insulation sheet etc. (xii)Renewal of worn out nuts, bolts and washers. (xiii) Disconnecting the existing old unserviceable On Load Change over switch and fixing new switch. (Note :-Parts defective shall be measured and paid separately under relevant items as supply only)
21Supply only in replacement of Electronic card for 150KVA.
22Supply only in replacement of Electronic sensing transformer set 12V/16V for 150KVA.
23Supply only in replacement of 12pin PCB connectors for 150KVA.
24Supply only in replacement of voltemeter selector switch/rotory switch for Amper meter for 150KVA. ( Make : AE/MECO/ L&T (Rishabh)/ SECURE
25Supply only in replacement of servo motor of 10 kg torque for 150KVA.
26Supply only in replacement of RC network of 10 KG torque for 150KVA.
27Supply only in replacement of cut off circuit PCB Low/ High for 150KVA.
28Supply only in replacement of voltage slector arm of Acute transformer for 150KVA.
29Supply only in replacement of Gear of 120 teeth for 150KVA.
30Supply only in replacement of Voltmeter of reputed (Make : AE/MECO/ L&T (Rishabh)/ Secure).
31Supply only in replacement of Ammeter. (Make : AE/MECO/ L&T (Rishabh)/ Secure)
32Supply only in replacement of Neon Indicators. (Make : AE/MECO/ L&T (Rishabh)/ Secure)
33Supply & topping up in replacement of oil for volatge stablizer up to required level for voltage stabilizers of dielectric strength 50 KV &aboveall as per IS specification.
34Supply and fix in replacement On load change over switch of 400 Amp cap 4 pole with with MS Encluser made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick channelfloor mounted and fixing in ground and necessary mounting accessories complete all as specified and as directed. Make : - Havells/L & T / C& S / Schinder
35S & F in replacement for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550MPa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and as directed.
36Supply, laying & fixinginsulated heavy duty electric cable with multi-stranded copper conductor, 1100 volts grade, cross- sectional area 35 sqmm single core laid on wall/ duct or floor including necessary clamps, cable lugs, glands, accessories etc. complete including Taking down old and unserviceable one all as specified & as directed. (Make: RR KABLE LTD/ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS)
37Supply, laying & fixinginsulated heavy duty electric cable with multi-stranded copper conductor, 1100 volts grade, cross- sectional area 50 sqmm single core laid on wall/ duct or floor including necessary clamps, cable lugs, glands, accessories etc. complete including Taking down old and unserviceable one all as specified & as directed. (Make: RR KABLE LTD/ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS)
38Taking down old and unserviceable point wiring and removing from the site and making good the disturbed surface complete all as specified and as directed.
39M&L point wiring for modular switches or normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through existingconcealed Conduit as requirement of siteincluding cadmium plated screws as per ISI, including replacement of 3 mm thick phenolic laminated sheet top covers on and includingsunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single pole complete all as specified and as directed. Make-Havells/Finolex/Standard.
40All as per item No. 6 above but one three pin 5 Amps socket out let on independent board.
41All as per item No. 6 above but one three pin 5 Amps socket out let on sameboard.
42All as per item No. 6 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and as directed. Make-Havells/Standard /Finolex
43All as per item No. 6 above but point wiring of copper cable multi stranded 4.00 Sqmm size for AC point wiring with 4.0 Sqmm size of earth conductor complete all as specified and as directed.Make-Havells/Standard/Finolex
44S & F modular switch one module, 5/6 Amp, one way, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand)
45S & F modular switch one module, 15/16 Amp, one way, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand)
46Supply and fixing of modular socket outlet (two module) 5/6 amps, 2 in 1, 2 & 3 pin combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand)
47Supply and fixing of modular socket out let (two module), 2 in 1, 3 Pin suitable for 5/6 Amp and 3 Pin suitable 15/16 Amp combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona/ Crabtree / Legrand)
48Material and labour for sub main wiring with two runs of single core 4.0 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC Conduit (heavy grade) of 25mm dia or more dia with all fittings and accessories surface type including one run 4.0 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed by Engr-in-Charge. (Make of cable:-NICCO / FINOLEX / RR KABEL/ HAVELL"S/ POLYCAB / KEI INDUSTRIES LTD Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST) Note : (a) Two runs of 4.00 sqmm copper cable and one run of 4.00 sqmm copper cable (earth wire) alongwith PVC conduit measured as one unit length. (b) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (c)Earth wire shall run inside the conduit. (d) Suitable colour code of wire shall be maintained for phase / neutral / earth).
49S & F in replacement MCB SP 240 Volts, 16 to 40 Amps complete all as specified and as directed. Make- Make-Havells/Legrend/Crabtree
50S & F in replacement MCB SPN, 240 Volts, 32/40/63 Amps complete all as specified and as directed. Make-Havells/Legrend/Crabtree
51S & F in replacementMCB TPN 63 Amp complete all as specified and as directed. Make - Havells/Legrend/Crabtree
52Material and Labour for frame work with angle ironfor frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and asdirected.
53S&F Aesthetically designed 2x2 LED flat panel recess mounting which provides soft-light of 34 Watts 4000K, complete all as specified and as directed. Make Havells/ CG/ Polycab
54Supply & fixing in replacement of Fingerprintss Templates : 500/100, Transaction Storage : 50000, Card Capacity : 500, Card Reader : Yes, Fingerprint Sensor : 500 DPI Optical Sensor, FAR : <=0.0001% / FRR : <=1%, Identication Speed : <1Sec, Display : 2.8” TFT Screen,Keypad : 4 x 4 Keypad, LED Indicator : Green /Red, Schedule Bell/Speaker : Mini Speaker, Communication : TCP/IP, USB-Host Standard features : Inbuilt Battery Backup, Self Service Query, SSR Recorder, Automatic Status Switch, DST,T9 Input, Power Supply : 5 V DC, 0.8 Amps, Operating Temperature : 0o C to 45o C, Operating Humidity : 20% - 80%,Dimension : 185x140x30 mm, Access Control, Relay : 5V, Support Exit Readers : Push Button, Buttery : Yes, Dual Mode : Either SSR Mode or Software Mode, Comatible Software & SDK, Smart Office suite desktop.Etime Track lite desktop, Major Application : Timer & Attendance, Canteen Management, School Attendance, Production Management, Gym & Clubs. Note :- Old unservisible Material shall be deposited to MES Store yard.
55Supply and fixing earth continuity conductor or main earthing lead (GI strip) of size 25 x 4 mm fixed to plinth or buried in ground or drawn any other situation as indicated for loop earthing etc including taking down old unserviceable one complete all as specified and as directed.
56Supply and fixing in SMF 12V, 200 AH Battery, QUANTA BATTERY with specifications as under:- Nominal voltage :-12 Volts Rated capacity (C20 Hour rate at 27°C) :-200 Ampere Hour Dimensions (±2 mm):-Length 541 mm X Width 232 mm X Height 238 mm Weight ± 1.0 Kgs (approx.):- 61.0 Kgs Capacity@ 80.6°F:-(27°C) as following :- 20 hour rate (10.0A) upto 10.5V :-200.0 Ah 10 hour rate (18.60A) upto 10.5V:- 186.0 Ah 5 hour rate (34.30A) upto 10.2V :- 171.50 Ah 1 hour rate (126.60A) upto 9.6V :-126.60 Ah 15 minute rate (327.90A) upto 9.6V :-81.97 Ah Internal resistance Fully charged battery 80.6°F (27°C) :-3.49mOhm Capacity affected (Temperature at C20 hour rate) as following :- 104°F (40°C) -110% 80.6°F (27°C) 100% 32°F (0°C) 80% 5°F (-15°C) 60% Self discharge 80.6°F (27°C) :- Capacity after 3 month storage 90% ,Capacity after 6 month storage 80% Terminal Type :- M8×25 mm Copper terminal Short circuit current :- 3655A Make:- Amaron, Exide, Luminous Note :- Old unservisible battery shall be deposited to MES Store yard.