Tender For Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput, koraput-Odisha

Civil Engineering Department has published Tender For Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput. Submission Date for this Tender is 23-11-2022. Building Repair Tenders in koraput Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

34731652
Tender For Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput
Open Tender
Indian
Odisha
koraput
23-11-2022

Tender Details

Construction Of New Girls Hostel Building ( G Plus 5 ) And Multi Utility Building ( Renovation ) At Govt Medical College Koraput Construction Of New Girls Hostel Building ( G Plus 5 ) And Multi Utility Building ( Renovation ) At Govt Medical College Koraput.

Key Value

Document Fees
INR 10000 /-
EMD
Refer document
Tender Value
INR 19.04 Crore /-

BOQ Items

Name of Work: Construction of New Girls Hostel Building (G+5) & Multi Utility Building (Renovation) at Govt Medical College Koraput.
Sl. No. Item Description
1CIVIL WORK Providing jungle cutting uprooting buses below 1.00m girth with cost of all labour and T&P required for the work etc. complete.
2SITE CLEARANCE
3Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
4Under 3.0mt (MUB)
5Above3.0mt (MUB)
6SITE CLEARANCE
7Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
8Ground floor (MUB)
9Dismantling and removing R.C.C. Chajja, Shelves, fins and parapet including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
10Ground floor (MUB)
11Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
12Ground floor (MUB)
13Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of thewater pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.
14All type of soil (Hostel)
15All type of soil (MUB)
16RETAINING WALL
17SITE CLEARANCE
18RETAINING WALL
19Carriage of earth by mechanical means with cost of all labour and T&P required for the work etc. complete. (Upto 5km).
20MUB
21SITE CLEARANCE
22Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge.
23HOSTEL BUILDING
24MUB
25Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. (Measurement will be taken on finished compacted section only).
26HOSTEL BUILDING
27MUB
28RETAINING WALL
29Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
30HOSTEL BUILDING
31MUB building
32Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portlandslag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
33HOSTEL BUILDING
34MUB building
35RETAINING WALL
36Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floorsusing Portland Slag Cement (PSC) with 12mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per specification anddirection of Engineer-in-charge.
37HOSTEL BUILDING
38Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
39HOSTEL BUILDING
40Footing
41Column up to PlLvl
42Tie/Plinth Beam
43MUB
44Footing
45Column up to PlLvl
46Tie/Plinth Beam
47RETAINING WALL
48Footing
49Retaining wall base 350mm top 230mm
50Column up to Roof Lvl :-
51HOSTEL BUILDING
52Ground Floor
53First Floor
54Second Floor
55Third Floor
56Fourth Floor
57Fifth Floor
58Mumty Floor
59MUB
60Ground Floor
61LINTEL :-
62HOSTEL BUILDING
63Ground Floor
64First Floor
65Second Floor
66Third Floor
67Fourth Floor
68Fifth Floor
69Mumty Floor
70MUB
71Ground Floor
72CHAJJA:-
73HOSTEL BUILDING
74Ground Floor
75First Floor
76Second Floor
77Third Floor
78Fourth Floor
79Fifth Floor
80Mumty Floor
81MUB
82Ground Floor
83ROOF BEAM:-
84HOSTEL BUILDING
85Ground Floor
86First Floor
87Second Floor
88Third Floor
89Fourth Floor
90Fifth Floor
91Mumty Floor
92MUB
93Ground Floor
94ROOF SLAB:-
95HOSTEL BUILDING
96Ground Floor
97First Floor
98Second Floor
99Third Floor
100Fourth Floor
101Fifth Floor
102Mumty Floor
103MUB
104Ground Floor
105STAIRCASE:-
106HOSTEL BUILDING
107Ground Floor
108First Floor
109Second Floor
110Third Floor
111Fourth Floor
112Fifth Floor
113LIFT WALL:-
114HOSTEL BUILDING
115Ground Floor
116First Floor
117Second Floor
118Third Floor
119Fourth Floor
120Fifth Floor
121Mumty Floor
122SHELVES:-
123HOSTEL BUILDING
124Ground Floor
125First Floor
126Second Floor
127Third Floor
128Fourth Floor
129Fifth Floor
130Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.
131HOSTEL BUILDING
132Ground Floor
133First Floor
134Second floor
135Third floor
136Fourth floor
137Fifth floor
138Terrace Floor
139MUB
140RETAINING WALL
141Providing weepholes in retaining wall, drain covers etc with 50mm pipe
142RETAINING WALL
143Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
144HOSTEL BUILDING
145MUB
146Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
147HOSTEL BUILDING
148Ground Floor
149First Floor
150Second floor
151Third floor
152Fourth floor
153Fifth floor
154Terrace Floor
155MUB
156Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
157HOSTEL BUILDING
158Ground Floor
159First Floor
160Second floor
161Third floor
162Fourth floor
163Fifth floor
164MUB
165Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
166HOSTEL BUILDING
167Ground Floor
168First Floor
169Second floor
170Third floor
171Fourth floor
172Fifth floor
173Terrace Floor
174MUB
175Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
176HOSTEL BUILDING
177Ground Floor
178First Floor
179Second floor
180Third floor
181Fourth floor
182Fifth floor
183Terrace Floor
184MUB
185Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
186HOSTEL BUILDING
187Ground Floor
188First Floor
189Second floor
190Third floor
191Fourth floor
192Fifth floor
193Terrace Floor
194MUB
195Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (OASIS / SOMANY/ KAJARIA or equivalent) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge.
196HOSTEL BUILDING
197Ground Floor
198First Floor
199Second floor
200Third floor
201Fourth floor
202Fifth floor
203MUB
204Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous)of approved make (OASIS / SOMANY/ KAJARIA or equivalent )as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.
205HOSTEL BUILDING
206Ground Floor
207First Floor
208Second floor
209Third floor
210Fourth floor
211Fifth floor
212MUB
213Providing and fixing 20mm thick mirror polished granite stone slab, machine cut stone (sample of granite should be approved by EIC) for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. laid over 25mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.In all floors and all heights.
214HOSTEL BUILDING
215Ground Floor
216First Floor
217Second floor
218Third floor
219Fourth floor
220Fifth floor
221Terrace floor
222MUB
223Providing and fixing 20mm thick mirror polished granite stone skirting, machine cut stone (sample of granite should be approved by EIC) for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. laid over 25mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.In all floors and all heights.
224HOSTEL BUILDING
225Ground Floor
226First Floor
227Second floor
228Third floor
229Fourth floor
230Fifth floor
231Terrace floor
232MUB
233Providing and layinganti-skid Matte Finish Vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 300mm x 300mm plain (Ivory)of approved make (OASIS / SOMANY/ KAJARIA or equivalent ) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge.
234HOSTEL BUILDING
235MUB
236Fixing of Ceramic Glazed Wall Tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 of size 30cm x 20cm / 20cm x 20cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.
237HOSTEL BUILDING
238MUB
239Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.
240HOSTEL BUILDING
241Providing fitting fixing of inter locked paver block of size 80 mm thick and filling the joints with sand of approvedv quality including rubbing & polishing etc comleteincluding costof all materials, labour with T&P etc. complete in all respect.
242HOSTEL BUILDING
243MUB
244Dressed seasoned sal woodworkframed andfixedinframesofdoors&windows including cost,conveyanceofall materials and cost of labour for fitting, fixing etc.complete as per the instruction of Engineer-in-Charge .
245HOSTEL BUILDING
246Ground Floor
247First Floor
248Second floor
249Third floor
250Fourth floor
251Fifth floor
252MUB
253Providing and fixing ISI marked32mm flush door shutters with 1mm laminates pasted both side confirming to IS 2202(Part1) including ISI marked necessary hardware fitting with approved colour paint over a coat of primer etc and hardware fittings such as, SS Concil Hinges (5"),stopper,Door magnet,SS Tower bolt,Pull handle/Mortise lock Handle,Cylinder coin & knob key & knob ,SS lock body and Door closer etc. includingcost of all labours, materials, conveyance, hardware fixing,loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
254HOSTEL BUILDING
255Ground Floor
256First Floor
257Second floor
258Third floor
259Fourth floor
260Fifth floor
261MUB
262Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride(UPVC) ( FENESTA / NCL VEKA LTD.)Three Track - Three Panel sliding window– 60- Series duly manufactured using UPVC reinforced profiles of 108mm x 45 mm x 2.5 mm for outer frames and Window Sash of 39 mm x 58 mm x 2.5 mmcapable of mounting singleglazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistantand the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials andproduct conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards.
263HOSTEL BUILDING
264Ground floor
265First floor
266Second floor
267Third floor
268Fourth floor
269Fifth floor
270MUB
271Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and designwith cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.
272HOSTEL BUILDING
273Ground Floor
274First Floor
275Second floor
276Third floor
277Fourth floor
278Fifth floor
279Terrace
280MUB
281Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.
282HOSTEL BUILDING
283Ground Floor
284First Floor
285Second floor
286Third floor
287Fourth floor
288Fifth floor
289Terrace Floor
290MUB
291Painting two coats with approved antifungal weather seal paints (ISI) of approved colour, shade on wall surface over a coat of wall primer(ISI) water bound including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge.
292HOSTEL BUILDING
293Ground Floor
294First Floor
295Second floor
296Third floor
297Fourth floor
298Fifth floor
299Terrace Floor
300MUB
301Finishing plastered surfaces of walls with water based wall putty of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
302HOSTEL BUILDING
303Ground Floor
304First Floor
305Second floor
306Third floor
307Fourth floor
308Fifth floor
309Terrace Floor
310MUB
311Painting two coats with plastic emulsion paint "Royale Shyne"to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.
312HOSTEL BUILDING
313Ground Floor
314First Floor
315Second floor
316Third floor
317Fourth floor
318Fifth floor
319Terrace Floor
320MUB
321Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.
322HOSTEL BUILDING
323Ground Floor
324First Floor
325Second floor
326Third floor
327Fourth floor
328Fifth floor
329Terrace Floor
330MUB
331Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
332HOSTEL BUILDING
333Ground Floor
334First Floor
335Second floor
336Third floor
337Fourth floor
338Fifth floor
339MUB
340Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m.
341HOSTEL BUILDING
342MUB
343Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.
344HOSTEL BUILDING
345Terraace Floor
346MUB
347Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1"6" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.
348Terraace Floor
349Providing, and applying two coat of primer 7E in both surface of expansion joint followed by applying polysulphide sealant Thioflex 600 on vertical joint surface after proper fixing of the necessary backup materialsas specified including cost ,conveyance ,taxes of all materials ,Labour, transportation charges etc. complete as per specification and direction of the Engineer-in-charge.
350Manufacturing, Providing and Fixing of (Glass Fibre ReinforcedConcrete) GFRC Jali/ Screen, make ""Samudyam or equivalent"" of thickness 25mm+/- 5mm with border thckness 50 +/- 10mm pattern, design and color of approved make to be fixed on/between RCC/Block work column or structural work with dry fixing method with appropriate frame work, using fastners and necessary hardware in building facade. The element shall be made from 53 grade portland cement make Birla/ JK cement or equivalent, quartz, fine silica sand, alkali resistant glass fibre make "OC" or equivalent, super plasticizer/ adhesives (make _BASF or equivalent) polymers and UV resistant synthetic inorganic pigments shall be used for pigmentation make " BAY FERROX" or equivalent. The material casting shall take place in synthetic rubber/ FRP mould manufactured by mould toolof revex/ reckli or equivalent.
351Ground floor
352First floor
353Second floor
354Thrd floor
355Fourth floor
356Fifth floor
357E.I. WORK INTERNAL WIRING.( Make of wire Finolex/ L&T / Anchor / Havels / V Guard /KEI/RR/eq make) Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.Group C
358Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. ) Average Length: 3mtr
359Recessed wiring to ceiling fan point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge.
360Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer in Charge.
361Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )
362Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer in Charge.
363Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge.
364PointwiringforProjector/A.C socket outlet with 16A plug socketand 16Acontrol switch atnearest separate location.
365Recessed wiringfor A.Csocket outletwith 20 amp SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure indusrial socket ,20A SP MCBincluding all accesories and connection as per direction of Engineer in Charge.
366SUBMAIN.
367Recessed wiring to submain in 4 x 16sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduitalong with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (PDB)
368Recessed wiring to submain in 4 x 10 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(For PDB )
369Recessed wiring to submain in 4 x 6sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For LDB)
370Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For EDB & 2TR AC)
371Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
372Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
373Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
374DISTRIBUTION BOARD .L&T/ Hager/ Legrand/ Siemens/ Panasonic/Eq make
375Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator)
3764 way (4 + 12) TPN double doorhorizontal type
3776 way (4 + 18 ), TPN , MCB DB double doorhorizontal type
378Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR)
3794 way SPN , MCB DB double door
3808 way SPN , MCB DB double door
3818 way SPN , MCB DB double door
38212 way SPN , MCB DB double door
383Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
3846 amp to 32 amp rating SP MCB , "c" series, 10KA breaking capacity
385Supply and fixing of following rating 240 V Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
38625 to 40 amp rating DP RCBO, 30mA
38725 amp rating FP RCBO, 30mA
38832 amp rating FP RCBO, 30mA
38940 amp rating FP RCBO, 100/300 mA
39063 amp rating FP RCBO, 100/300 mA
391CABLE .RR/KEI/eq make
392Supplyof one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes of cable as required.
3933.5 C x 300 sq.mm Al
3943.5 C x185sq.mm Al
3953.5 C x150sq.mm Al
3963.5 C x95sq.mm Al
3973.5 C x70sq.mm Al
3983.5 C x 50 sq.mm Al
3993.5 C x 25 sq.mm Al
4004 C x 16 sq.mm Al
401Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required.
402Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required.
403Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required.
404Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
405Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
406Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
407Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required.
408Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade ofsize exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE/METAL pipe as required.
409Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required.
410Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required.
411Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface as required.
412END TERMINATION
413Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
4143.5 C x 300 sq.mm Al
4153.5 C x185sq.mm Al
4163.5 C x150sq.mm Al
4173.5 C x95sq.mm Al
4183.5 C x70sq.mm Al
4193.5 C x 50 sq.mm Al
4203.5 C x 25 sq.mm Al
4214 C x 16 sq.mm Al
422PANEL:L&T/Hager/Siemens/Legrand/eq make
423Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including Busbars,interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used.
424MAIN LT PANEL with 800A 4P Micro Processor Based EDO ACB (50kA)-1 Nos as incomer, 630A 4P MCCB (50kA) -3 Nos, 200A 4P MCCB (50kA) -2 Nos, 63A 4P MCB-2 Nos, 32A 2P MCB-6 Nosas Outgoing.
425MAIN ESSENTIAL PANEL with 200A 4P C/O Switch -1 No &200A 4P MCCB (50kA) -1 No as incomer, 125A 4P MCCB (36kA) - 2 No, 100A 4P MCCB (36kA) - 3 Nos, 63A 4P MCB- 2 Nos, 32A 2P MCB-6 Nos as Outgoing.
426MAIN NON-ESSENTIAL PANEL with 800A 4P C/O Switch -1 No &630A 4P MCCB (50kA) -1 No as incomer, 200A 4P MCCB (36kA) - 3 No, 125A 4P MCCB (36kA) - 2 Nos, 63A 4P MCB- 2 Nos, 32A 2P MCB-6 Nos as Outgoing.
427ZONE-1/3 PANEL (ESSENTIAL) with 100A 4P MCCB (36kA) -1 No as incomer, 40A 4P MCB- 2 Nos, 32A 4P MCB- 8 Nos, 32A 2P MCB-6 Nos as Outgoing.
428ZONE-2 PANEL (ESSENTIAL) with 125A 4P MCCB (36kA) -1 No as incomer, 40A 4P MCB- 3 Nos, 32A 4P MCB- 11 Nos, 32A 2P MCB-6 Nos as Outgoing.
429ZONE-1/2 PANEL (NON-ESSENTIAL) with 200A 4P MCCB (36kA) -1 No as incomer, 63A 4P MCB- 6 Nos, 40A 4P MCB- 10 Nos, 32A 2P MCB- 6 Nos as Outgoing.
430ZONE-3 PANEL (NON-ESSENTIAL) with 125A 4P MCCB (36kA) -1 No as incomer, 63A 4P MCB- 6 Nos, 40A 4P MCB- 2 Nos,32A 2P MCB- 6 Nos as Outgoing.
431EXTERNAL LIGHT PANEL with 63A 4P MCB- 1 No as incomer, 32A 4P MCB- 3 Nos, 32A 2P MCB-9 Nosas Outgoing.
432Automatic Power Factor Correction Panel of 220 kVAR capacity suitable for 440 Volts 3 phase 50 c/s & having APP type heavy duty 525v , self fusing, low loss, self healing, resin bonded without oil, three phase delta connected capacitors (confirming to IS:2834 IS:13346 IEC-831/1-2, & IEC-439(1-2), housed in alluminum cans & having current limiting contacts circuit to suppress switching in rush current & having 12 step microprocessor based APFC relay with digital displaycontrolling capacitors of rating5,10,20, 25 & 50 kVAr for improvement of targeted P.F. of the system & provided with 630 Amps 4P MCCB (50kA) and set of 600/5 CTs with Digital Ammeter and selector switch, capacitor duty contactors with 3Pole MCCB of suitable rating , auto manual selector switch, ON/OFF indicating lamp and push button, 1 No 800/5 CT in the the main panel, including interconnection and control wiring with copper cable etc. complete with 14% detuned reactor as required.10kVArshall be of fixed type.
433MAIN PANEL with 200A 4P C/O Switch, 160A 4P MCCB (36kA) - 1 No as incomer, 40A 4P MCB - 5 Nos followed by 10-40A 3P kWH Energy Meter, 32A 2P MCB- 12 Nos followed by 5-30A 1P kWH Energy Meter with 32A DP Contactor & Timer- 1 Nos as Outgoing and 3nos 160/5A CT, 0-160A Digital Ammeter and 160A aluminium Bus Bars.
434EARTHING
435Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
436Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
437Extra for using salt and charcoal for G.I or copper plate earth as required
438Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required.
439Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required.
440Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
441Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked on surface or in recess for connection etc as required.
442Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required.
443LIGHTNING ARRESTOR
444Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete asrequired.
445Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
446Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
447Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required.
448Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, copper tube,having single prong at top,with 85mm dia 3 mm thick copper base plate including holes etc. complete asrequired
449Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
450Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
451Providing and fixing of testing joint, made of 20 mm x 3 mm thick Copper strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required.
452Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required
453Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required.
454Providing and laying of copper tape 32 mm x 6 mm from earth electrode directly in ground as required.
455Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
456Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
457Extra for using salt and charcoal for G.I or copper plate earth as required
458FIXTURE
459Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.
460Surface mounted indoor type 18W SINGLE LED TUBELuminaire with LED Lamp Similar to WIPRO Cat No. WIO921208 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
461Surface mounted outdoor type 40W LED TUBEwith LED Lamp Similar to WIPRO Cat No. LE20-491-XXX-57-G1 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
462Surface mounted indoor type 36W 2"x2" Square LED Luminaire with LED Lamp Similar to WIPRO Cat No. CRCO10S036HP57G2 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
463Surface mounted indoor type 6W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-350-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
464Surface mounted indoor type 12W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-101-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/equivalent make.
465Surface mounted indoor type 15W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-131-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
466Surface mounted indoor type 10W BULK HEADLED Luminaire with LED Lamp Similar to WIPRO Cat No. LW07-141-XXX-57-XX Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/equivalent make.
467Surface mounted indoor type 10W MIRRORLED Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-111-XXX-65NE3 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
468SITC of indoor type LED SKIRTING LIGHT mounted on G.I modular box with face plate & cover of suitable size , Similar to LEGRAND MYRIUS Cat No. 673036 or equivalent.
469Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.
470Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.(Bjaj/Crompton/Havells/Eq make)
471Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.
472Supply, Installation, testing and commissioning of exhaust fan of 150 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.
473Providing and fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored
474DATA, TELEPHONE & TELEVISION
475Recessed wiring to telephone pointwithclip in type modular telephone socket (RJ 11) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
476Recessed wiring to television point with clip in type modular television socket ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
477Recessed wiring to LAN pointwithclip in type modular lan socket (RJ45) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
478Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.
479Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
480Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required.
481Supply and drawing of TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid & protected with FR PVC sheath inexisting surface / recessed STEEL / PVC conduit as required.
482Supplying and drawing UTP 4 pairLAN cat-6 cable in the existing surface / recessed PVC conduit as required.
483Supply & Fixing of 9U Rack single section glass door with cable manager, fan & AC Distribution.Complete as required .(Make-VALRACK, VEROPRESIDENT, HCL)
484Supplying, Installing, Testing & commissioning of 24 port distribution data managed 2 layer giga switch suitable for rack mounting. CISCO
485Supplying,Installing, Testing & commissioning of 24 port patch panel suitable for rack mounting D-LINK/HP/3Com or Equivalent.
486Supply and fixing of 10 pair telephone tag box with KRONE terminal
487EXTERNAL LIGHTING
4887M long G.I.octagonal pole complete with RCC foundation, required G.I base plate , single-arm of ERW galvanised pipe 30mm - 1M length,providingGI pipes for cable entry junction box with prewired 6 Amp SP MCB, loop-in -loop-out , terminal block, wiring with copper wire upto the fitting etc. complete
4894M long G.I.octagonal pole complete with RCC foundation, required G.I base plate , Single-arm of ERW galvanised pipe 30mm - 1M length,providingGI pipes for cable entry junction box with prewired 6 Amp SP MCB, loop-in -loop-out , terminal block, wiring with copper wire upto the fitting etc. complete
490Supply , fixing& termination of OutdoorStreet Light LEDLuminaire with 72w LED Lamp similar to WIPRO Cat No.LR02-781-XXX-57-G2 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
491Supply , fixing& termination of OutdoorStreet Light LEDLuminaire with 40w LED Lamp similar to WIPRO Cat No.LR02-451-XXX-57-G1or equivalent.
492Supply &fixing ofBUSH LIGHTsuitable for LED lamp Equiv. to WIPRO LF05-600-036-27-XX . With Junction Box.
493Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
494Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 2Cx 6 sq.mm Al.direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
495Supplying and making end termination with brass compression gland and aluminum lugs for 2C x 6 sq.mm of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
496Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.
497Supplying and fixing ofof 50mm G.I pipe(Medium Class) along with accessories ingroundincluding cutting & making good the sameas required.
498Supply, delivery & installation of GI coil earthing made out of 8 swg GI wire closely wound in shape of a helical coil of 50mm diameter with 115 numbers of turns including excavation of earthpit of size 800x 800x 1500mm in all kinds of soil, back filling the excavated pit with alternate layers of salt, charcoal around the coil with a diameter of 300mm upto 1000mm and balance by good quality soil, end termination complete as required.
499FIRE FIGHTING & FIRE ALARM SYSTEM
500Sub-Head - I - DOWNCOMER.
501Supply, erection, testing and commissioning of following sizes of heavy grade ("C" class) mild steel pipe, flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts"Heavy class" confirming to IS:1239-1974 Part - I and part - II with upto-date amendment i/c giving two coats of hot bituminous paint. Make- Tata/Zindal/Sail/Eq
502100mm dia
50380mm dia
50425mm dia
505Providing and fixing Single headed, S.S ISI marked oblique patternhydrant landing valvewith80mmdia flangedinlet and 63mm dia instantaneous type female outlet complete withcap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type "A"). Make-KARTAR, Safex, Fireshield,Safe Guard
506Providing and fixing standard short size gunmetal branch pipe with gunmetal nozzle 16mm dia outlet with standard male instantaneous spring lock type 63mm dia coupling.Branch pipe and nozzle shall confirm to IS : 903-1985. Make-KARTAR, Safex, Fireshield,Safe Guard
507Providing and fixing Non-percolatingflexible canvas hose(RRL type-"A") ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneoustype gunmetal 63mmdia. IS markedMaleandfemale couplings (IS:903)bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire. Make-KARTAR, Safex, Fireshield,Safe Guard
508Providing and fixing standard fireman"s axe with heavy insulated rubber handle complete.
509Providing and fixing dial type pressure gauge with isolation cock and pipe. Make-H.guru/Emerald/Fiebig/Equivalent
510Dial diameter 100mm calibration 0-15 kg.
511Providing and fixing first aid fire hose reel equipment confirming to IS : 884-1969 with upto date amendments finished with post office red spray paint and complete with following as required :Make-KARTAR, Safex, Fireshield,Safe Guard
51220mm dia 30metres long hose tubing of approved make confirming to IS : 5132-1969 with upto date amendments.
513Swinging type hose guide fixing bracket assembly
5146mm outlet gunmetal nozzle with shut off valve as required
515Providing and fixing brass/bronze lever operated ball valves of full flow with stainless steel ball (AISI 304 and spindle AISI 401) with settling and gland of superior quality and having minimum working pressure of 15 Kg/cm2.Make-Kartar/Zoloto/H Sarker/Eq.
51625NB
517Supply, installation, testing and commissioningof Fire Brigade inlet connection with provision for Four male instantaneous coupling fabricated out of 150 mm dia. approved make heavy class MS pipe with non-return valve, Butterfly valvefor fire fighting system including making connection by providing necessary piping & fittings to the fire storage tank, fire fighting wet riser, sprinkler system painting the same with 3 coats of enamel paint over a coat of Zinc Chromate primer all complete as per drawings, specifications. Make-Minimax, Safex, Fireshield,Kartar.
518a) Three way
519Sub-Head II- Terrace Pump
520Supplying,installation,testingandcommissioningof electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump). Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation,conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitablecementconcretefoundationdulyplastered and with anti vibration pads. Make-wilo,kirloskar/lubi/equivalent.
521900 lpm at 35 m Head
522Sitcof Terrace Pump Controller
523Supplying,installation,testingandcommissioningof pump controller.Make-c&s/l&t/crompton/Eq
524Sub-Head IIIFIRE PUMPS & ANCILLARY WORKS
525Providing,installation,testingandcommissioningof cast ironY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange.Make-Kartar/Zoloto/H Sarker/Eq.
526100mm dia
527Providing, fixing, testing & commissioning ofC.I. dual plated Non-return valve [PN 1.6 Rating (16kg/cm2] complete2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes .Make-Kartar/Zoloto/H Sarker/Eq.
528100 mm dia
529Providing, fixing, testing & commissioning of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers complete . [PN -1.6 rating (16kg/cm2)]Make-Kartar/Zoloto/H Sarker/Eq.
530100NB
531Supply,Providing & fixing Pressure Switchthe most commonly used fluid control components of Aluminum enclouser with storage temprature 40 to 180°F (-40 to 82°C) along with ambienttemprature 0 to 160°F (-18 to 71°C),set point shifts less than 1% of range for a 50°F (28°C) ambient temperature change. Unit will operate down to -40°F (-40°C) but with reduced repeatability. Maximum media temperature 200°F (93°C), Shock Set point repeats after 50 G, 10 millisecond duration. Switch output One SPDT including seven electrical terminations; Refer to "How to Order" and vibration set point repeats after 10 G, 5-500 CPS.Make-Honeywell/Danfoss/Jhonson controls.
532Sub-Head - IV -Hand Appliances
533Note :All the fire extinguishers shall be ISI marked and filling/validity date shall be painted.
534Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed towall with brackets complete with internal charge.Make-Minimax, Safex, Fireshield, Safe Guard
535Capacity 4.5 kg
536Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed towall with brackets complete with internal charge. Make-Minimax, Safex, Fireshield, Safe Guard
537Capacity 6 kg
538Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold.Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. Make-Agni,/Cease fire/Eq.
539Sub-Head V FIRE DOOR
540Supply, installation, testing and commissioning offire metal door. Pressed Galvanized steel confirming to IS 277 specification.Door frame shall be Double rebate profile of size 139 x 57 mm made out of 1.20mm minimum thick galvanized steel sheet& single leaf door. Provision should be kept for grouting with cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf should be 43mm thick fully flush double skin door. Door leaf shall be manufactured from 1.0 mmthick galvanised steel sheet single leaf door. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. painting system will be powder coating finished. Make: Coburn /Garg or Equivalent
541Size : 1250mm x 2250mm(single leaf )
542Sub-Head VI EXIT SIGNAGES
543supplying,fixing of following type 2 mm thick photo luminecent signages non toxic non radio active maintenance free self glowing safety signages comprising of supplied chargeable crystals to glow in the dark with high intesity luminous 1.2mm aluminium sheet properties by chemical coated ( Vinayal & Tap not accepted) and covered with UV Protection layer printed with graphics symbol etc as required.
544For FIRE EXIT(12"" X 6"")
545For FIRE HYDRANT(16"" X 6"")
546For Lift (12"" X 6"")
547For Stair case (12""x6"")
548Arrows symbol(12""x6"")
549Sub-Head VII FIRE ALARM SYSTEM
550SITC ofMicroprocessor based,Conventional type Fire Alarm Control Panel with 2 nos. of zone.operating voltage 24v dc. Make: Honey well / Agni/ Esser/Eq
551Hooter with Strobe Supply, installation, connecting, testing and commissioning of Conventional Hooters cum strobe min. 95 db output , the cost includes of control module .Make: Honey well / Agni/ Esser/Eq
552Supply, installation, connecting, testing and commissioning of  Conventional Manual Call Box in ABS plastic  as required complete Pull Down Type. Make: Honey well / Agni/ Esser/Eq
553Looping Cable Supplying, installing, testing and commissioning of Fire Survival armoured cable,Fibre glass tape wrapped, ZH inner, outer sheath 2C X 1.5 sq. mm, PVC insulated copper wires with aluminium armour confirming to IS standards and specifications. Make-Polycab/RR cable/Eq
554HVAC
555Supplyinstalation testing commissioning of HI-WALL TYPE UNIT with OEM manufactured rotary compressor Three Star rated non inverter type with stablizer (R410A/R32- refrigerant)suitable for 230V, 50 Hz, single phase AC. ) & making all arangement for installation i/c factory fabricated bracket, cutting the wall, making good the damages etc. as required(Make:- Daikin ,Hitachi or Eqiv) & making all arangement for installation i/c factory fabricated bracket, cutting the wall, making good the damages etc. as required.with Refrigerant Copper Piping Make-Rajco/Mandev/Maxflow ,PVC drain piping including insulation Kinni foam connectionswithunitswithU-trap, nipple clamps etc. of make-Ashirbad/Astral/Supreme
5562 TR
557MECHANICAL VENTILATION
558Supply installation, testing , commissioning of SISW Backward curved centrifugal fans (Bearing, motor and shaft shuould be outside of airflow path).Consistng of motor , drive arrangement, MS channel common base frame for fan. Fan should be AMCA certified for AIR, SOUND and FEG( minimum FEG should be 80). Outlet velocity of the fan should not exceed 11 m/s. Shound level of the fan should not exceed 75db(A) @ 3 meter distance. Installed motor Kw. should be 30% higher than fan brake Kw. (Moter make- Havels/ CGL/ BBL/ Hindustan Motors). ( Fan Make-kruger, Nicotra, Greenheck)
5593900 CFM @25mm static pressure
5602700 CFM @25mm static pressure
561Supply, installation, balancing and commissioning of Site fabricated Gi sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specifications.(As per SMACNA)(Make-TATA, SAIL,Jindal)
56224 Gauge ( Thickness 0.63mm)
563Supply, Installation, testing and balancing of powder coated Alluminium Grilles complete withnuts, bolts, screws etc. as per drawings and specifications. (Make-Glenstroms, carryaire,System air )
564Supply air grille withAlluminium volume control damper
565Supply, fixing and commissioning of exhaust air louvers with section comprising of powder coated Aluminium louvers & bird screen as per specifications. (Make-Glenstroms, carryaire,System air )
566ELECTRICAL WORKS
567Supply, laying, testing and commissioning of following sizes of PVC sheathedXLPEinsulatedAluminiumconductorarmouredcablesof 1100Vgradeonsurfaceofwallorinexistingcabletrays/masonry ducts/ hume pipe with fixing hardware etc. as required. (Make- Polycab, Havels,RR cable )
5684 Core x 2.5 Sq.mm
569STARTER PANEL FOR FAN
570Supply, Installation, testing & commisioning of 3 KW 3 phase DOL starer with D range Contactor & LR1D OLR in 2mm CRCA steel sheet duly painted having 1 no 32A 4P MCB, 1 no 3P power contactor, 1 no 9 to 15A PLR, 1 no 30A CT operated ameter, 3 nos. phase indication lamp, 3 nos. ON,OFF,TRIP indicator, 2 nos. ON/OFF push button, 1 no. emergency stop with provision for remote operation for ventilation fan. (Make- L & T, Siemens, Havels)
571CCTV
572SUPPLY AND INSTALLATION 64 CH NVR Up to 12 MP resolution 8 SATA (DS-8664NI-I8 ) Make: HIKVISION or equivalent.
573SUPPLY AND INSTALLATION 32 CH NVR Up to 12 MP resolution 2 SATA (DS-7632NI-K2 ) Make: HIKVISION or equivalent.
574SUPPLY AND INSTALLATION 16 CH NVR Up to 12 MP resolution 2 SATA (DS-7616NI-K2 ) Make: HIKVISION or equivalent.
575SUPPLY AND INSTALLATION 2MP DOME CAMERA (DS-2CD1323G0E-I) Make: HIKVISION or equivalent.
576SUPPLY AND INSTALLATION 2MP BULLET CAMERA (DS-2CD1023G0E-I) Make: HIKVISION or equivalent.
577SUPPLY AND INSTALLATION 16 PORT GIGA POEMake: HIKVISION or equivalent.
578SUPPLY AND INSTALLATION 8+1 PORT GIGA POEMake: HIKVISION or equivalent.
579SUPPLY AND INSTALLATION 4 TB HDD Make: SEAGATE or equivalent.
580SUPPLY AND INSTALLATION 2U RACK WITH FANE PDU Make: NETRACK or equivalent.
581SUPPLY AND INSTALLATION 9U RACK WITH FANE PDU
582SUPPLY AND INSTALLATION UTP 4P CAT 6CABLE(As Per Actual) Make: D-LINK or equivalent.
583SUPPLY AND INSTALLATION UTP 4P CAT 6CABLE(As Per Actual)
584ELEVATOR
585“Testing, Supply, Delivery, Installation & Commissioning with approved materials, labour etc. in all respect complete of02 nos. Passenger Lift from (GF to 5th Floor), 01 no. Passenger cum Stretcher Lift from (GF to 5th Floor),as detailed in specifications and complete in all respect for NEW HOSTEL & MUB BUILDING AT Koraput MEDICAL COLLEGE CAMPUS
586Providing Passenger Lift ,
587Supplying, installation, testing and commissioning of 10 passenger (680Kg) lifts having contract speed of 1.25 MPS serving different floors in the lift shaft including 12 months maintenance period as per detailed specifications enclosed (Annexure) and Terms & Conditions mentioned in NIT and as under :- Location – Girls Hostel , Koraput , Odisha. Type – Gear less machine with Machine Room Speed – 1.25 MPS Floors - 6 floors (G+5 floors) Travel – 16.5 meters (approx.) Stops & Opening – 6 Nos at the same side Controller – microprocessor controlled electronically regulated A.C. variable voltage & variable frequency (VVVF) drive using pulse width modulation (PWM) with phase reverse relay. Automatic Rescue Device complete with dry maintenance free battery of maximum 12 AH capacity each with required Nos. Operation : Microprocessor based single automatic push button with Simplex collective selective /without attendant. Power - 415 Volts, 3 phase, 50 Hz, 4 wires system A.C. Type of Doors- Horizontal Sliding – Centre Opening
588Car – 800mm clear opening with power operated fully automatic centre opening horizontal sliding, Stainless steel scratch proof 1.5 mm thick moon rock finish body work stainless steel drop ceiling and CFL/ LED lamps for lighting inside the car and fan. PVC 3mm thick (minimum) flooring. Landing Doors- Automatic and multi beam full height infra red detector automatic centre opening horizontal sliding 1.5 mm thick stain less steel scratch proof moon rock finish. Fire rating -120 min. Stainless steel hand rail not less 600 mm long at 900mm above floor level to be fixed. Brail system including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS: 14665, and as per attached detailed specifications and additional conditions i/c provision for temporary scaffoldings and all minor building works
589Original manufacturer among the approved makes i.e. JOHNSON/OTIS/KONE/SCHINDLER/MITSUBISHI/eq make
590Supplying, installation, testing and commissioning of 15 passenger-cum-stretcher (1020Kg) lifts having contract speed of 1.25 MPS serving different floors in the lift shaft including 12 months maintenance period as per detailed specifications enclosed (Annexure) and Terms & Conditions mentioned in NIT and as under :- Location – Girls Hostel , Koraput , Odisha. Type – Gear less machine with Machine Room Speed – 1.25 MPS Floors - 6 floors (G+5 floors) Travel – 16.5 meters (approx.) Stops & Opening – 6 Nos at the same side. Controller – microprocessor controlled electronically regulated A.C. variable voltage & variable frequency (VVVF) drive using pulse width modulation (PWM) with phase reverse relay. Automatic Rescue Device complete with dry maintenance free battery of maximum 12 AH capacity each with required Nos. Operation : Microprocessor based single automatic push button with Simplex collective selective /without attendant. Power - 415 Volts, 3 phase, 50 Hz, 4 wires system A.C. Type of Doors- Horizontal Sliding – Centre Opening
591Car – 900mm clear opening with power operated fully automatic centre opening horizontal sliding, Stainless steel scratch proof 1.5 mm thick moon rock finish body work stainless steel drop ceiling and CFL/ LED lamps for lighting inside the car and fan. PVC 3mm thick (minimum) flooring. Landing Doors- Automatic and multi beam full height infra red detector automatic centre opening horizontal sliding 1.5 mm thick stain less steel scratch proof moon rock finish. Fire rating -120 min. Stainless steel hand rail not less 600 mm long at 900mm above floor level to be fixed. Brail system including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS: 14665, and as per attached detailed specifications and additional conditions i/c provision for temporary scaffoldings and all minor building works.
592Original manufacturer among the approved makes i.e. JOHNSON/OTIS/KONE/SCHINDLER/MITSUBISHI/eq make
593P.H. WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipesconforming topipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge
594GroundFloor
59520mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59625mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59732mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59840mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59950mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
600In 1st Floor
60120mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60225mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60332mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60440mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60550mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
606In 2nd Floor
60720mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60825mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60932mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61040mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61150mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
612In 3rd Floor
61320mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61425mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61532mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61640mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61750mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
618In 4th Floor
61920mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62025mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62132mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62240mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62350mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
624In 5th Floor
62520mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62625mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62732mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62840mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62950mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
630In 6th Floor
63140mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
63250mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
633Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.
634250mmthick wall in Ground floor
635In 1st Floor
636In 2nd Floor
637In 3rd Floor
638In 4th Floor
639In 5th Floor
640Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. in Ground Floor
641In 1st Floor
642In 2nd Floor
643In 3rd Floor
644In 4th Floor
645In 5th Floor
646Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor
647In 1st Floor
648In 2ndfloor
649In 3rd Floor
650In 4th Floor
651In 5th Floor
652Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge
653250mm to 375mmthick wall
654in Ground Floor to 5th Floor
655Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge
65615mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
65715mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
65815mm dia CPBib cock (Con-CHR-047KN Jaquar make)
65920mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make)
66015mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
66115mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
66215mm dia CP extension piece
66315mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
66425mm dia G.M or Brass F.W valve (Sakti make)
66540mm dia G.M or Brass F.W valve (Sakti make)
666125mm dia CP gratings
66715mm CP revolving shower (Jaquar)CON-CHR-209KN
66850mm dia G.M or Brass F.W valve (Sakti make)
669Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge
670110mm dia U-PVC SWR pipes(Supreme/Ashirvad)
671110mm U-PVC door bend
672110mm U-PVC door Tee
673110mm U-PVC plain Tee
674110mm U-PVC plain Y
675110mm dia U-PVC offset without ear
676110mm U-PVC plain bend
677110mm U-PVC vent cowl
678110mm dia U-PVC "P" trap
679110mm dia suitable PVC clamp
680Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge
68110 litres PVC L.L. Cistern (Slimline-white)
682Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make)
683580mm size Orissa pan(Hindware/Parryware/Jauar)
684Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge
685Fixing of squatting urinal (Parryware/Hindware/Jauar)
686Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge.
687E.W.C. with seat cover (Parryware/Hindware/Jauar)
688EWC(Matrix set)No.70002(P-18)
689Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge
690550mm x 400mm size W. H. Basin with Porcelain Pedestal (Parryware/Hindware/Jauar)
691Under Counterbasin(560x450)Hindware-No.10095
692Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge
693600mm x 450mm size B.E mirror
694Large size mirror with frame(75x0.60x0.90)=40.50
695Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
696600 x 125mm plate glass shelf with CP guard rails(Jaquar)AKP-CHR-35771P
697Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
69825mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N
699CP towel Ring(Jaquar)ACN-ACR-1121N
700Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
701CP soap holder (Jaquar)ACN-ACR-1131N
702Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge
703600 x 450 x 250mm size S/S kitchen sink (Jayana make )
704Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips broken including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C In 1st Floor
705In 2nd Floor
706In 3rd Floor
707In 4th. Floor
708In 5th. Floor
709Supplying all materials, labour, T&P and providing cement flush pointing with C.M (1:3) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
710In Ist Floor
711In 2nd Floor
712In 3rd Floor
713In 4th Floor
714In 5th Floor
715Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including cement punning,watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
716In Ist Floor
717In 2nd Floor
718In 3rd Floor
719In 4th Floor
720In 5th Floor
721Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1"-6" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.
722In Ist Floor
723In 2nd Floor
724In 3rd Floor
725In 4th Floor
726In 5th Floor
727Supplying all materials, labour, T&P and providing and filling cynder including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
728In Ist Floor
729In 2nd Floor
730In 3rd Floor
731In 4th. Floor
732In 5th. Floor
733Supplying all materials, labour, T&P and providing Ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc complete as per direction of the Engineer in charge. (vitrified tiles of size300x300 of make- Kajaria/Somany/Johnson/Orient Bell/Rakplain/printed series to be pre-approved by the Engineer in charge)In 1st Floor (Kajaria-Fogparla or equivalent make)
734In 2nd Floor
735In 3rd Floor
736In 4th Floor
737In 5th Floor
738Supplying all materials, labaour, T&P and fixing ceramicglazed tiles in dados skirting on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed ith pigments to match the shades of the tiles etc. complete as per direction of the Engineer-in-charge.(ceramic vitrified Glazed tiles in wall of size 450x300 ) of makeKajaria/Somany/Johnson/Orient Bell/Rak) plain/printed series to be pre-approved by the Engineer-in-charge. in Ground Floor(Kajaria-Durenmarfil or equivalent make)
739In Ist Floor
740In 2nd Floor
741In 3rd Floor
742In 4th Floor
743In 5th Floor
744Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
745Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge
746Finishing wall surface of walls with providing two coats wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.
747In Ist Floor
748In 2nd Floor
749In 3rd Floor
750In 4th Floor
751In 5th Floor
752Supplying all materials, labour, T&P and distempering two coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge
753In Ist Floor
754In 2nd Floor
755In 3rd Floor
756In 4th Floor
757In 5th Floor
758Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge
759Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
760Inside size 760mm x 760mm x 460mm
761Fitting and fixing RCPC cover slab (0.45m dia)
762Supplying all materials, labour, T&P and providing kodappa slab in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge
763Supplying all materials, labour, T&P and providing granite tiles in slab, treads and landing on 20mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc all complete as per direction of the Engineer in charge
764Construction of 40000 Liters RCC Over head Tankin sixth floor with RCC Stagging(Domestic & Fire fighting)
765Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete.
766Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gauge.in 6th Floor.
767Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in 6th Floor.
768RCC floor roof, chajja etc
769RCC Beam, Column, wall etc
770Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site.
771Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
772Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete
773Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge
774Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.
775Aquagurd Pure Chill 120 PSS UV
776Sinking of 200mmx150mm dia Bore Well through DTH method.- 2 Nos.
777Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
778Drilling of 200mm dia bore0 to 30 mtr
779Drilling of 200mm dia bore31 to 45 mtr
780Drilling of 150mm dia bore41 to 125 mtr
781Labour for lowering the following size of PVC casing pipes with or without slotted pipes as per necessity from ground level upto 300 mtrs depth and fitted and set up in perfectly vertical position including cutting and threading of blank pipes and slotted pipes and supplyinging and fixing of all jointing materials ,extra sockets and T&P etc. all complete and keeping the top of casing pipe threaded including plugging the tubewell to prevent entry of foreign materials
782Lowering of 200mm dia PVC casing pipes 0 mtr to 30 mtrs
783Lowering of 200mm dia PVC casing pipes 31 mtr to 45 mtrs
784Cost of 200mm dia PVC schedule - 80 pipe
785Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
786Supplying all materials,labour,T&P andproviding around sealing by cement concrete grouting of annualr space around GI/PVC housing pipe upto 5 mtr below ground level ( as per drawing ) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer-in-charge . Mimimum one meter of casing pipe to nserted in the bore in to the rock the bottom to ensure sanitary sealing ( excluding cost of cement which willbe supplied by the Department )
787Sanitary sealing upto 5 mtr below ground level
788CC(1:2:4) with 12mm chips for grouting up to 5 mtr Depth in
7891x5x3.14x(0.15-0.10)
790Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.
7912HP Three Phase 3 stage submersible pump set.
792DOL control panel
79350mm S. S. Nipple, S. S. bolt & clips
79450mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap
7952.50mm Sqm Submersible flat cable
796Steel rope with cover
79720mm dia rigid U-PVC pipe
79850mm dia HDPE pipe
799Labour charges for lowering, testing, commissioning & transportation to site etc.
800Supply all materials, labour, T&P and providing, fitting and fixing of centrifugal pump set to run on 3phase/1phase line voltage ranging from 320 volt to 450 volt with suitable control pannel, jointing with GI/ PVC/ HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.
8015 HP 3 phaseHorizontal submerssiblepump set.
802DOL control panel
803Labour charges for lowering, testing, commissioning & transportation to site etc.
804Supplying all materials, labour, T&P and providing and laying in trenches PVC ASTM pipeof the following nominal bore, tube fittings, testing all complete as per specification and direction of the Engineer in charge
80550mm dia PVC ASTM
806Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesof the following nominal bore and pipe fittings with clamps including making good the wall and testing as per specification and direction of the Engineer in charge
80750mm dia CPVCpipe (sch-80)
808Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
809100m x 0.45m x 0.60m =27.00
810Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge.
81150mm dia Brass N. R. Valve
81250mm dia Brass Check Valve
81350mm dia Brass F. W. Valve
814Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge
815Inside size 250mm x 250mm x 560mm
816Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
817Inside size 910mm x 910mm x 910mm
818Addl depth
819Fitting and fixing RCPC cover slab (0.45m dia)
820Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
8211.40m dia x 2.00m deep
822Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
823110mm dia u-pvc pipe alround concrete
824160mm dia u-pvc pipe alround concrete
825200mm dia u-pvc pipe alround concrete
826Supplying all materials, labour, T&P and constructing circular type man hole chamber of the following sizewith cement concrete (1:4:8) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar (1:5), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, 12mm thick cement plaster (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
827Circular MH inside dia 1200mmx1670mm with sides sloped upto560mm
828Cost of RCPC Cover
829Construction of 50 KLDSTP Civil Works
830Earth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
831-do- with Ist additional depth of 1.50 m over the initial lead and lift
832Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge.
833Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
834Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
835R.C.C. work of M-30 grade with 20mm and down grade black hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per spection and the direction of the Engineer-in-charge.
836Base slab
837Wall
838Roof Slab
839RCC Lintle
840Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
841Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site.
842Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
843Quantity same as itemabove inside
844Supplying and fitting and fixing stainless steel 304 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below doors and windows with ss platevincluding welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.
845Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge
846Supplying all materials, labour, T&P and providing brick work using fly ash bricks in CM(1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
847Supplying all materials, labour, T&P and providing 16mm thick cement plaster in CM(1:6) over brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
848Supplying all materials, labour, T&P and providing 12mm thick cement plaster in CM(1:4) over brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
849Supplying all materials, labour, T&P and providing two coats of plastic paint over a coat of primer of approved shade, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
850Quantity same as itemabove inside
851Supplying all materials, labour, T&P and providing two coats of weather coat over a coat of primer of approved shade, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
852Quantity same as itemabove 231
853Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
854Quantity same as itemabove inside
855Electro Mechanical portion of 50 KLD STP
856Supplying, Installation, testing & commissiongof Packeged type Prefabricated (MS with 3mmFRP coating with anti-corrosivecoating Modular STP Capacity of 50 KLD on FMR (Fludised Media Reactor) / FAB (Fludised Aerobic BioReactor) technology with Lamella/Tube Settler andproviding all equipment, piping etc.at site including erection testing & commisioning of equipments, electricals, piping for Sewage Treatment Plant (Make - ION Exchange (India) Ltd.)
857The RawSewage shall be domestic Sewage and the qualityof treated sawage shall be as under: BOD : Shall not be more than COD : Shall not be more than TSS : Shall not be more than Oil and grease : Shall not be more than 10 mg/litre The STP shall be covered following
858MS bar Screen : Supplying , installing , testing and commissioning of 1No.barscreenintheexistingcivilstructureinfrontoftheintake works , so as to exclude the large sized particleswith associated set ofguide anglesinMSflatof10.00mmscreenkeptinclinedat45 degreetothehorizontalat40mmc/cwithoneno.handrackinGI. (Necessarycorrection/modificationrequiredtobedoneinexisting civilstructureshallbedonebythecontractorathisowncost).Bar rackshallbefabricatedfromSS-304barstocoverthewidthofthe screen chamber with a racking arm for manual operation. Size: 10 mm
859RawSewagePumps: Supplying, installing, testing and commissioning of 02 Nos (1W + 1S) centrifugal, Non - Submersible type raw sewage water pumps with a solid handling capacity of 40 mm to pump sewage from equalisationsumptoaerationtankatuniformflowrate.Thepump shall be three phase, three HP electrical motor mounted on a common base frame each of these pumps shell also include. (Make : Jhonson / Kriloskar / equi. )
860a). Dry run protection. b) 1 No.Pressure gauge 4" dial with valve tee and fittings. c) 2nos.castironleveropertedslimsealtypebutterfly valvesofCI bodyandspheroidalgraphiteirondisc(SGiron),withnitrilerubber seal , tested to 10 kg / sq. cm Confrming to BS 5155 / MF6 standards andincludingasetofGIflangesasper BS-10table1includingbolt nuts,GIwashers,andneoprenerubbergasketsCompleteetc.( Make: Crane / Intervalve / Audco ) on the delivery side.
861d) 2Nos. Slimsealflap typecheck valvewith CI body andcast steel disc pressure rating PN-10 kg/ sq. cm including a set of GI flanges as perBS-10table1includingboltnuts,GIwashers,andneoprene rubbergasketscompleteetc., (Make: Expert / Intervalve / Audco )onthe delivery side. e) GI manifold finished neatly with hot dip galvanizing to 100 microns withflangedendoneithersidesandcollarprovisionforconnectivity of above mentioned valves. Thesepumpsshallbesuitableforthefollowingrequirements:Flow rate = 2.5 cum/hr., Head 10 meter.
862PRE-FABRICATED STP
863a) SEWAGE TREATMENT PLANT (STP) - MS TANK with 3mmthick FRPcoating inside with Akzo Noblecoatingonbothsides ofSewagetreatmentplant, having an inbuilt Aeration-I& Aeration-II,Lamella/Tubesettlingtank,chlorinecontacttankwith laddersprovisiononeachplantandrailingetc.,havingmin.sizeof (L x B x H)4.0mx 2.13 mx2.2m,minimunvolumeofreactor should be19CuMtr.orasperapprovedOEM"sdesignandcapacitybut shouldhaveminimumretentiontimeof6hours,Minimumthickness of MS sheet should be 5 mm with special anti corrosive coating.
864Following shall also be provided in Sewage Treatment Plant.
865b) Air Diffusuion system forSTP aeration chamer I&II:Supplying installing,testingandcommissioningof06Nos.airdiffusersof varyingsizesconsistingoffinebubblediffuser alongwithmembrane fromEDI, USAshallconsistsofsetofEPDMmembranes,SS304 clips,PVC support pipe(10kscpressure rating),PVCfitting,nylon ropebraidedhosewithallaccessoriestomakeitretrievable&to provide cloq- free oxigen for Aeration tanks.
866c) MBBR ( Moving Bed Bio Film Reactor) / FMR ( Fluidized Media Reactor) Media : Supplying, installing, testing and commissioning of 1.5 cum MBBR/FMR Media.
867d)LAMELLACLARIFIERMECHANISM : Supplying, installing, testing and commissioning of one set of lamella/tube settler clarifier mechanism to fit into clarifier tank which consists of inclined overlapping FRP plates which will be arranged to form a separate dimentation chamber or the cells between each pair of adjacent plates. The overlapping additive projected area of several plates will be a factor of increasing surface settling area proportion to the number of plates used.
868The inlet flow will divide and enter the tower part of each sedimentation cell from its two opposite sides. As the water will displace upward in smooth, gently, flow, the suspended solids coalesce to from precipitates which will settle in the chambers on the lower portion of each lamella plate. Influent water flows upwards over the plates. The deposited precipitates increase in size until they slide or roll down the inclined surface of the plates. This will then be collected in the hopper provided at the bottom of the separator.
869Air Diffusion System for EQ ( Equalization ) tank& SHT( Sludge HoldingTank) : Supplying, installingandcommisioning of Air Grid of varying sizes as per manufacurers specifications with PVC flexible hose HDPE pipegrid (or) as per OEM manufacturers design to provide clog - free oxygen for Equalisation Tank & Sludge Holding Tank.
870AirBlowers:Supplying, installing, testing and commissioning of TwinLobe designtype02 Nos (1W + 1S)airblowercompletewithmotors, pulleys,RigidonepieceCIcasingandsideplates,silencer,base plate,anti-frictionbearings,Rotaryoilsealingshavinghorizontal configuration
871a)TwinLoberoot typeAir blower of75 m3/hrat 0.37kg/sqcm capacitycomprisingofcommonbaseframe,suctionsilencer,non, return,Vbelt,safetyvalve,beltguard,driveanddrivenpulleys, pressuregauge,interconnectionpiping, dischargesilencer,anti vibration pads including required motor of 3.0 HP, 1500 rpm, IE-2 efficiency with IP-55 protection
872b) 2 Nos. cast iron lever operated slim seal type butterfly valves of CI bodyandspheroidalgraphiteirondisc(SGiron),withnitrilerubber seal,testedto10kg/sq.cmconformingtoBS5155/MF6standards andincludingasetofGIflangesasper BS-10table1includingbolt nuts, GI washers, and neoprene rubber gaskets complete etc. ( Make: Crane / Intervalve / Audco / Kitz / Zoloto / equivalent )on the delivery side.
873c) 1 No. pressure gauge 4"dial with valve tee and fittings.
874ChlorineDoser:Supplying, installation, testingand commissioning of on line electronic sodium hypo dosing unit with automatically operated dosing pump, etc., Theunitshallcompriseof the following.
875One No. Single moulded FRP cylindrical type chemicalsolution tank of 100 litres capacity having detachablelidswith moulded inserts for mounting of pumps and starter.
876OneNo.Electronicdiaphragmtypepositivedisplacementpump,for chemicaldosingwithplastic head.Theelectronicpumpshallbe operatedon220Vsinglephasesupply andshallbemounteddirecty on the tank top. ( Make: Milton Roy / Asia LMI )
877Completesetofpipes,valvesandfittings,footvalvemagneticfloat switch to trip the dosing pump at low level of chemical in the tank.
878Thefreechlorinecontentinthefilteredwatershallnotbelessthan 0.5 PPM.Shall consists of one no. 100 Ltrs., HDPE / LLDPE tank with one no. PP, diaphragm type pump of capacity: 0 - 4 LPH shall be provided.
879The pump shall be suitable for the following requirements: Min. Actuating Pressure - 0.3 kg /sq cm; Max., working pressure - 2.5 kg/sq cm; Max., Temperature - 50 deg C; HP - 1/2 and Dosing flow range - 0 4 LPH
880Multigrade Filter: supplying, installation, testing and commissiong of multigrade sand pressure filter for litration of treatedsewage water. The filter shall be designed for a specific velocity of 4 m3/hr/sq.m area shall not be less then 16 Inch DIA with Minium HOS 65 Inch.
881The filtration unit shall comply with the following technical requirements: Flow rate - 4 cu.m/ hr Backwashduration - once in 24 hours for 20 min.Filtering Media - Multi grade of Sand / Pebbles: Pressure drop across unit -1.0 kg sq.cm (max) and dia of filter - 16 Inch, HOS - 65 Inch. MOC- FRP, operating pressure: 3.5 kg per sq. cm
882Further the filtration unit shall comprise the following:
883Thefiltershallbefittedwithinletdistributionandbottomcollecting system. Orifice board/ Rotameter for monitoring back wash flow to be fitted. Initial charge of underbed and carbon fotlering media as required. Complete set of valves, perssure gauge with needle valve and frontal pipe work done with Gray PVC pipes.
884ACTIVATEDCARBONFILTER(ACF):Supply, installation, testing and commissioning of activated carbon filter for filtration and removal of colour in treated sewage water. The filter shall be for 4 m3/hr flow rate and designed to operate for 12 hours.
885TheACFshallbedesignedforaspecificvelocityof4 m3/hr/sq.m area and the approx. dia shall not be less than 16 Inch DIA with 65 Inch HOS ( Height on straight ) of vessel.
886Further the filtration unit shall comprise the following:
887Thefiltershallbefittedwithinletdistributionandbottomcollecting system. Orifice board / Rotameter for monitoring back wash flow to be fitted. Initial charge of underbed and carbon filtering media as required. Complete set of valves, pressure gauge with needle valve and frontal pipe work done with Gray PVC pipe.
888FilterFeedPumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) filter feed pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 25meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB )
889PlantPiping : Supply, Installation, Testing Commisioning ofpipes & Valves with fittings suchastees, crosses, plugs, sockets, elbows, unions,flanges,sleevepieces, check nutsetcfor the entire STP Plant.
890a)Providing and fixing of MS pipes to I.S. 1239 including all fittings like bends, flanges, valves, etc., ( Make: Jindal / Tata )
891b) Inter connecting pipe works with valves for air line- Jindal/Eqv
892c) Inter connecting pipe works with valves for water line- PVC/UPVC
893Sewage TransferPumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) Submersible pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 10meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB )
894Sludge Re-circulation Pumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) Re-circulation pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 25meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB )
895Ultra Filtration Feed Pumps Capacity-3m3/Hour, Head-25-30 Meter
896Supplying, installing, testing & commissioning of Ultra Filtration System (UF) of Capacity 50 KLD, electro mechanical system (Excluding Civil construction)
897Electrical Panel Works:
898a) Supplying ,installaing ,testing and commissioning of Electrical panelsconsistingofMCCpanel(motorcontrolcenter)to accommodate all the drive units with cabling , glanding within the STP Compartmental,designIndoorwallmountedtypewithtopentryfor cabletheinternalcomponentseitherSiemen/ ABB Shallbeprovided with 1 no. Energy meter.
899To receive , control and distribute electrical power at440 V, 50Hz , ACinasheetsteelhouse.MCCistobemanufactured/assembled asperthelatestISIspecification,IndianElectricityRules,Including specialrequirementsofconcernedstateelectricityinspectorate.The switch board shall be fabricated out of 14 SWG sheet steel and shall be un cubical design.MCC of suitable rating to take care of full load of thesewagetreatmentplantincludingallmotorsandlighting.MCC shall be provided with the following feeders.
900Incoming Feeder : MCCB, Ernergy meter (Voltmeter with selector switch), LED type indication for 3 phases Outgoing Feeder: MCCB Motor feeder, 1 No 3 phase and netural of suitable capacity to be provided Busbar: Aluminium
901b) Power Cables (LT) for use on 415V system shallbeof 1100 volt grade, Aluminium conductor, PVC insulatedas per IS: 1554 (Part I). Motor up to 5 HP copper conductor cable should not be less than 1.5 sq mm of size to be used.
902c) Control Connector, Lugs / Sockets shall be of copper conductor and of Aluminium for conductor cable, suitable, solderless, crimping type.
903d)MCCpanelshouldhavenecessaryfeaturestooperatetheair blowers according to requirement of DO by means of VFD.
904e) Installation and wiring with fixing cable trays.
905Multi Utility Building at Koraput Medical College at Koraput(PH Works)
906Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor PVC pipes conforming to C-PVC1785/89 ( Sch-80 ) and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge .
907In ground floor
90820mm dia C-PVCPipe
90925mm dia C-PVCPipe
91040mm dia C-PVCPipe
911In 1st floor
91225mm dia C-PVCPipe
91340mm dia C-PVCPipe
914Supplying all materials,labour,T&P and cutting holes through existing brick work including making good the damages in cement mortar(1:4) for taking GI pipes and fittings/PVC pipes and fittings etc.all complete as per PH specification and direction of the Engineer-in-charge.
915In ground floor
916250mm thick wall
917Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge
918In ground floor
919Supplying all materials , labour, T&P and cutting grooves in pucca floors and walls for taking P.V.C pipes and G.I fittings etc. and making good the damagesincluding finishing complete as per P.H. specification and direction of Engineer-in-charge.
920In ground floor
921Supplying all materials , labour, T&P and fitting and fixing brass/CP fittings of following nominal bore with supply of all jointing materialscomplete as per P.H. specification and direction of Engineer-in-charge
92215mm C.P.Bib cock(CQT-CHR-23037)Jaqquar.
92315mm C.P.Pillar cock (DRC-CHR-37001)Jaquar.
92420mm dia CP Concealed Stop cock(FLR-IVC-5083N)Jaquar.
92515mm dia CP Angle Stop cock.(AQT-CHR-3059)
92615mm dia CP two way Bib Cock ( KLN-CHR-19041 )Jaquar.
927HEALTH FAUCET1.2 M TUBE(B FLOW PREVNTOR))(ALD-CHR-577)Jaquar.
92825mm dia brass fullway valve(Shakti Make)
92940mm dia brass fullway valve(Shakti Make)
93015mm dia. C.Pextension piece
93115mm dia. C.P flange
932125mm dia CP gratting
933Supplying all materials ,labour ,T&P and fixing 10 litres capacity PVC low level flushing cistern with a pair of PVC brackets complete with fittings such as pvc siphonic arrangements, 15mm dia nominal size pvc ball valve with polythene float ,pvchandles, unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet , and connecting the inlet pipe with supply mainetc.all complete as perspecification and direction of Engineer-in-charge
93410 ltrs. capacity PVC low level cistern (Slimline-white)
935Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 2.60m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge.( Sintex/Supreem/Rotomax)
9362000 ltrs capacity rotational moulded polyethylene cylindrical vertical water storage tank .-In Ist. floor
937Sanitary Installation
938Supplying all materials,labour,T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No.13592/1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification,testing,earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of Engineer-in-charge
939110mm dia U-PVC SWR Pipe (Supreme/Ashirvad)
940110mm dia U-PVC Door Tee
941110mm dia U-PVC Plain Band
942110mm dia U-PVC Plain Tee
943110mm dia U-PVC Offset without ear
944110mm dia U-PVC Plain Shoe Bend
945110mm dia U-PVC Door Bend
946110mm dia U-PVC "P"Trap
947110mm dia U-PVC Cowl
948110mm dia U-PVC Socket plain
949Supplying all materials , labour, T&P and cutting holes through existing brickor laterite masonry wall for takingU-PVC / HCI pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
950250mmto 375mmthick wall
951Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.
952Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
953Supplying all materials , labour, T&P andfixing Vitreous chinawater closet ,squattingpan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal sizeincluding fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci "P" or "S" trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
954580mmx440mm size Orissa Pan ( White )
955Supplying all materials,labour,T&P and fitting and fixingvitrous Chaina washed down water Closet (European type water closet - EWC) with integral "P" or "S" type trap to the floor including wodden plug and chromoum plated screw including jointing the trap with soil pipe in CM(1:1) fixing plastic seat cover for washed down water closet with crmium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of Engineer-in-charge.
956European Water Clost "S" trap
957Supplying all materials ,labour ,T&P andfixing Wash basin with hole for pillar taps with cast iron or MS brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. fixing pedestralfor wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin , fixing 12mm dia CP brass waste etc.all complete as perspecification and direction of Engineer-in-charge.
958550mmx400mm size wash hand basin with Porcelain pedestal
959Under Counterbasin(560x450)Hindware-No.10095
960Supplying all materials,labour,T&P and fixing standard sized Glass-shelf with C.P brass bracket and guard rail complete fixed to wooden pluges with screw etc.all complete as per specification and direction of Engineer-in-charge.
961600mmx125mm glass shelf with CP/NP guard rails
962Supplying all materials ,labour ,T&P andfixing standard sizedCP brass towel rail completewith CPbrass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as perspecification and direction of Engineer-in-charge
963Fixing 25mmx600mm long CP towel rail25mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N
964CP towel Ring(Jaquar)ACN-ACR-1121N
965Supplying all materials ,labour ,T&P andfixing CP Soap Holder complete with CP brass bracketsfixed to wooden plugs with chromium plated brass screws etc.all complete as perspecification and direction of Engineer-in-charge
966CP soap holder (Jaquar)ACN-ACR-1131N
967Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted min 5mm thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge
968600mmx450mm size B.E mirror (fixed type)
969Large size mirror with frame(6x0.60x0.90)
970Supplying all materials, labour, T&P and providing kodappa slab in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge
971Supplying all materials, labour, T&P and providing granite tiles in slab, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc all complete as per direction of the Engineer in charge
972Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
973Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
974Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
975Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
976Fitting and fixing vetrified tiles with matt finish Kajaria ( Fog Perla or equivalent ) on floor or steps & landing on 25mm. Thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, roylalities and taxes etc. all complete as per direction of Engineer-in-charge.(600mmx600mm)
977Fitting and fixing vetrified tiles with matt finish Kajaria ( Duren Marfil / Equvalant) to dados skirting & risers of steps on 12mm tick C.P(1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, roylalities and taxes etc. all complete as per direction of Engineer-in-charge. (600mmx300mm)
978Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
979Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge
980Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.
981Aquagurd Pure Chill 120 PSS UV
982External S/D portion
983Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge
984Supplying all materials ,labour ,T&P and constructing Inspection Chamber ofinside size 760mmx760mmx460mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge
985Inside size : 760mmx760mmx460mm
986Supplying all materials ,labour ,T&P and constructing Man Hole Chamber ofinside size 910mmx910mmx910mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken black hard granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing, conveyance of all materials to worksite, payment of royalty, taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge
987Inside size : 910mmx910mmx910mm
988Fitting and fixing RCPC cover slab (0.45m dia)
989Supplying all materials, labour, T&P & constructing Soak Way Pit of the following size with dry brick walling from bottom upto invert of inlet pipe andKB brick work in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size crusher broken hard black granite metal on bed, 12mm thick cement plaster in cement mortar (1:4) inside and outside over masonry brick work, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips fitted with iron lifting handles including earth work in open well excavation in all kinds of soil and refilling of cavity around the pit and painting the iron works, watering, curing,cost of all materials,conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per approved drawing,PH specification and direction of the Engineer-in- charge.
9901.80m dia x 2.60m deep inside size Soakway Pit
991Supplying all materials,labour,T&P and laying in trenches ( to level or slope ) unplasticized PVC pipe conforming to IS:4985/2000 of the following outside dia for class-3 (0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/ as per manufactures"s providing and laying in trench cement concrete(1:4:8) with 40 mm size hard granite metal in the Type-C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer-in-charge.
992110mm dia U-PVC pipe ( Allround concrete )
993160mm dia U-PVC pipe ( Allround contrete )
994Sinking of 200mmx150mm dia Bore Well through DTH method.- 1 Nos.
995Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
996Drilling of 200mm dia bore0 to 30 mtr
997Drilling of 200mm dia bore31 to 45 mtr
998Drilling of 150mm dia bore41 to 125 mtr
999Labour for lowering the following size of PVC casing pipes with or without slotted pipes as per necessity from ground level upto 300 mtrs depth and fitted and set up in perfectly vertical position including cutting and threading of blank pipes and slotted pipes and supplyinging and fixing of all jointing materials ,extra sockets and T&P etc. all complete and keeping the top of casing pipe threaded including plugging the tubewell to prevent entry of foreign materials
1000Lowering of 200mm dia PVC casing pipes 0 mtr to 30 mtrs
1001Lowering of 200mm dia PVC casing pipes 31 mtr to 45 mtrs
1002Cost of 200mm dia PVC schedule - 80 pipe
1003Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
1004Supplying all materials,labour,T&P andproviding around sealing by cement concrete grouting of annualr space around GI/PVC housing pipe upto 5 mtr below ground level ( as per drawing ) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer-in-charge . Mimimum one meter of casing pipe to nserted in the bore in to the rock the bottom to ensure sanitary sealing ( excluding cost of cement which willbe supplied by the Department )
1005Sanitary sealing upto 5 mtr below ground level
1006Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
10071x5x3.14x(0.15-0.10)
1008Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.
10092HP Three Phase 3 stage submersible pump set.
1010DOL control panel
101150mm S. S. Nipple, S. S. bolt & clips
101250mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap
10132.50mm Sqm Submersible flat cable
1014Steel rope with cover
101520mm dia rigid U-PVC pipe
101650mm dia HDPE pipe
1017Labour charges for lowering, testing, commissioning & transportation to site etc.
1018Instalation of 1.5 HP submerssible pump-motor
1019Supplying all materials, labour, T&P and providing fitting & fixing submerssible pump with squirrel cage induction type submerssible electric motor to run single-phase line voltage ranging from320 to450 volt confirm to IS 8034/89 with following specification suitable control pannel jointing with GI/PVC/HDPE pipe, electrification, testing, commissioning , trial running, conveyance of all materialto work site, payment of all taxces etc all complete as per PH specification and direction of Engineer-in-charge.
10201.5 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110L.P.M with outlet dia of 25mm
1021DOL contol pannel suitable for 1.5HP pump
10222.50 sqmm flate cable
102350mm dia steel short piece
102450mm dia C.I Bracket
102550mm diaHDPEPipes
102625mm dia rigid U-PVC pipe
1027Well cap
1028Steel rope with cover
1029Supplying all materials, labour, T&P and constructingBore well protectionchamber of the inside size 650x650x1000hightwith cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ashbrickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4)inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.
1030Bore well chamber
1031Construction of 20 users Brick Septic Tank- 1 No.
1032Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge.
1033Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
1034Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1035Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1036Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1037In F&P
1038Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1039In ground floor
1040Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1041Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1042R.C.C floor androofslabs
1043Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1044Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge.
1045Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge
1046Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
1047Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge