Renovation / Improvement Of E&M Equipment At Recently Reconstructed Joharipur Online Bps.-Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. D.S.R 2018 Code No -1.10.2 Group C 2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2*1.5 Sq. Mm ( D.S.R 2018 Code No -1.17.2 ) 3 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( 2 X 2.5 Sq. Mm ( D.S.R 2018 Code No -1.17.11 ) 4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 2 X 4 Sq. Mm ( D.S.R 2018 Code No -1.17.20 ) 5 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( D.S.R 2018 Code No -1.21 ) 20 Mm 6 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 A Switch Dsr- 1.24.1 7 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Switch Dsr- 1.24.3 15 / 16 A Switch Each 8 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5 / 6 A Socket Outlet Dsr- 1.24.4 9 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 A Socket Outlet Dsr- 1.24.5 10 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. ( D.S.R.2018 Code No -1.33 ) 11 Supplying And Fixing Brass Batten / Angle Holder Including Connections Etc. As Required. ( D.S.R 2018 Code No -1.34 ) 12 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc.As Required. ( But Without Mcb / Rccb / Isolator ) 06 Way, Double Door ( D.S.R 2018 Code No -2.3.1 ) 13 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required Single Pole And Neutral ( D.S.R 2018 Code No -2.10.2 ) 14 Itc Of Ceiling Fan, Including Wiring The Down Roads Of Standard Length With 1.5 Mm Fr Pvc Insulated Copper Conductor, Single Core Cable Etc. As Req. Dsr-2018 Code:-1.44 15 S / F Stepped Type Electronic Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required Dsr-2018 Code:-1.25 16 Installation Of Exhaust Fan In The Existing Opening, Including Making Goods The Damage, Connection, Testing, Commissioning Etc. As Required. Dsr 2018, Code No.1.50.1 17 Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. ( D.S.R 2018 Code No -5.2 ) 18 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. ( D.S.R 2018 Code No -5.16 ) 19 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. ( D.S.R 2018 Code No -5.12 ) 20 Supply And Fixing If 32Mm Dia. 02 Mtrs. Long G.I Pipe ( Medium Class ) Bracket For Mounting Of Fluorescent / Hpmv / Hpsv Street Light Fitting On Pole / Wall Including Bending The Pipe To The Required Shape, 2 Nos. 40Mmx3mm Flat Iron Clamps With Nuts, Bolts And Washer, Painting The Flat Iron With Primer And Finish Paint Etc. As Required. Dsr-2018, Item Code- 12.34 21 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Ampere Dsr 2018- 2.14.3 22 Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube Etc. Directly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. Dsr1.41 23 Supply And Fixing Of 3 Mm Thick Phenolic Laminated Sheet As Required. Dsr Code- 1322 24 New Generation Energy Saving And Environmental Friendly Long Life Led Street Light Made Up Of Pressure Die Cast Aluminum Housing With High Efficient Led As Lighting Source And Pc Cover Having Top Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik07. 45W Led S.O.R Code; 19.10.5 25 New Generation Energy Saving And Environmental Friendly Long Life Led Street Light Made Up Of Pressure Die Cast Aluminum Housing With High Efficient Led As Lighting Source And Pc Cover Having Top Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik07. 70 W Led S.O.R Code; 19.10.6 26 S / O Of Ceiling Fan Having Size 1200 Mm ( 48 ) . Make:- Anchor, Orient, Standard, And Any Approved Make By Djb S.O.R Code; 20.1.2 27 S / O Of Exhaust Fan Having Size 375 Mm ( 15 ) , 1440 R.P.M. Of Single Phase 230 Volts. Make:- Anchor, Orient, Standard, Almonard And Any Approved Make By Djb S.O.R Code; 20.2.2 28 Higher Wattage Decorative Ultra Slim Aluminum Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficient Ready To Use Pack. 36 W Led 6500 K. S.O.R Code; 19.3.3 29 Supply Co2 Type Fire Extinguisher Capacity 4.5 Kgs Completes In All Respect. Make: - Life Guard / Omex / Ceasefire / Isi Mark. 30 S / O Of Exhaust Fan Having Size 375 Mm ( 15 ) , 1440 R.P.M. Of Single Phase 230 Volts. Make:- Anchor, Orient, Standard, Almonard And Any Approved Make By Djb S.O.R Code; 20.2.2 31 Higher Wattage Decorative Ultra Slim Aluminum Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficient Ready To Use Pack. 36 W Led 6500 K. S.O.R Code; 19.3.3 32 Supply Co2 Type Fire Extinguisher Capacity 4.5 Kgs Completes In All Respect. Make: - Life Guard / Omex / Ceasefire / Isi Mark. 33 Supply Of Main Switch Box For Load Upto 100 Amp, 415 V For Isolating The Line. Three Pole With Kitkat Fuse Of Make: Havells / C&S Or Any Other Djb Approved Make.