Military Engineer Services-MES has published Tender For Repairs To Flooring Roof Sheet Wooden Work Joinery Incl Misc Repairs And E/M Repairs At Alg Vijaynagar Under Ge (Af) Jorhat. Submission Date for this Tender is 22-11-2022. Shed Construction Tenders in vijaynagar Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34623233
Tender For Repairs To Flooring Roof Sheet Wooden Work Joinery Incl Misc Repairs And E/M Repairs At Alg Vijaynagar Under Ge (Af) Jorhat
Open Tender
Indian
Arunachal Pradesh
vijaynagar
22-11-2022

Tender Details

Repairs To Flooring Roof Sheet Wooden Work Joinery Incl Misc Repairs And E/M Repairs At Alg Vijaynagar Under Ge (Af) Jorhat

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: REPAIRS TO FLOORING, ROOF SHEET, WOODEN WORK, JOINERY INCL MISC REPAIRS AND E/M REPAIRS AT ALG VIJAYNAGAR UNDER GE (AF) JORHAT.
Sl. No. Item Description
1M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surface of any description, not otherwise described over 10cm width or girth after preparation of surface complete all as specified and directed.
2M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of old steel surfaces of any description exc. 10 cm in width or girth complete all as specified and directed .
3M&L for applying one coat of anti-corrosive synthetic enamel paint to old steel surfaces as on roof of any description exc. 10 cm in width or girth complete all as specified and directed .
4Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including "Nainital" or similar pattern roof covering complete all as specified and directed.
5S&F Pre- painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screw complete all as specified and as directed.
6S&F Pre- painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, ridge, facia etc. complete fixed with self tapping screw complete all as specified and as directed.
7S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, fixed with L-type or J-type or cranked hook bolts in lieu of screws complete all as specified and directed.
8Labour only for re-fixing of old galvanised corrugated mild steel sheeting as per item 4 here-in-before completeall as specified and as directed.
9S&F in repairs 15 mm dia Bib taps fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed .
10S&F in repairs 15 mm dia pillar taps, cast copper alloy, with capstan heads, "chromium plated", screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
11S&F in repairs 15mm dia stop valves, cast copper alloy, screwed down, high pressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed, all as specified.
12S&F in repairs vitreous china wash down water closet pan (pedestal pattern), size 580 x 440 mm white (excluding fixing bolts, flushing cistern and flush pipe), complete all as specified and directed.
13S & F in repairs 12.50 litres capacity PVC low level syphonic action type flushing cistern "white" with inlet, ball valve, float and handle including brackets and flushing pipe, complete all as specified and directed.
14S & F in repair PVC connection 15mm size with PTMT Nuts of length 450mm and fixed in repairs, complete all as specified and as directed.
15Dismantling of water storage tank exc 250 & not exceeding 500 ltr capacity and removing from site, complete all as specified and directed.
16Dismantling of water storage tank exc 500 & not exceeding1000 ltr capacity and removing from site, complete all as specified and directed.
17S&F 500 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) (ISI marked) hoisted and fixed in position all as specified in SSR part-Icomplete all as specified and directed.
18S&F 1000 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) (ISI marked) hoisted and fixed in position all as specified in SSR part-Icomplete all as specified and directed.
19S&F 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
20S&F 15mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
21S & F vitreous china wash hand basin size 580 x 450 mm (flat back or angle back type) "white" with 32mm dia brass chromium plated waste fitting, galvanised iron "light grade" 32 mm bore waste pipe, a pair of cast iron brackets duly painted / erecting stand including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 including taking down unserviceable wash hand basin and connected items, complete all as specified and directed.
22S & F in repairs 32 mm dia waste coupling of PTMT (half of full threaded) (min weight 32-45 gms) complete all as specified and as directed.
23Taking up or down steel water tubing 15 mm bore including connections and fitting complete all as specified and directed.
24Re-fixing of old steel tubing 15 mm dia and connections in new or old position (Walls, ceiling, floors, etc.) complete all asspecified and directed.
25S&F 15 mm dia steel tubing "Medium Grade", galvanized ISI marked, with all fittings, fixed to walls, ceiling or laid in floor complete all as specified and directed.
26Taking up or down steel water tubing 20 mm bore including connections and fitting complete all as specified and directed.
27S&F in repairs 20 mm dia steel tubing "Medium Grade", galvanized ISI marked, with all fittings, fixed to walls, ceiling or laid in floor complete all as specified and directed.
28Hacking out old broken glass (any thickness, size , quality or description) wooden frame or stone, concrete or brick surrounds, glazed with putty or fixedwith beads, complete all as specified and directed.
29S&F 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square of area not exceeding0.5 sq.m in each pane complete all as specified and directed.
30S&F in repairs 75mm bore PVC (SWR) soil, waste and ventilating pipe single socket in any length with rubber ring joint fixed to wall with CI clamps, including taking down / up unserviceable pipe, complete all as specified and as directed.
31S&F in repairs 110mm bore PVC (SWR) soil, waste and ventilating pipe single socket in any length with rubber ring joint fixed to wall with CI clamps, including taking down / up unserviceable pipe, complete all as specified and as directed.
32S & F in repairs 75 mm bore (dia) PVC (SWR) bends any radius, complete all as per specified and as directed.
33S & F in repairs 110mm bore (dia) PVC (SWR) bends any radius, complete all as per specified and as directed.
34S & F in repairs 75mm bore PVC (SWR)junction, single (Single T) equal or unequal fixed to existing pipe complete all as per specified and as directed.
35S & F in repairs 110mm bore PVC (SWR)junction, single (Single T) equal or unequal fixed to existing pipe complete all as per specified and as directed.
36Dismantling timber scantling, 40 sqcm and over in section, in any position, in unframed work, complete all as specified and directed.
37Dismantling timber fillets, Rails, posts, rafter purlings etc under 40 Sqcm in section in any position as in unframed work, complete all as specified and directed.
38Taking down chowkats or frame with shutter (without taking off shutters from the frame) of area not exceeding1.5 Sqm each complete all as specified and directed.
39Taking down shutter of any description of area not exceeding1 sqm each complete all as specified and directed.
40Taking down chowkats or frame with shutter (without taking off shutters from the frame) of area exceeding 1.5 sqm but not exceeding 4 Sqm each complete all as specified and directed.
41Taking down shutter of any description of area not exceeding 1 sqm but not exceeding 2 sqm each complete all as specified and directed.
42S&F 2nd class hard wood plain, solid, straight, chowkhat and framed, wrought, rebated on the solid, rounded or chamfered, put together with pinned at joints complete all as specified and directed
43S&F 35mm thick, 2nd class hard wood plain, Plain, framed, panelled shutters(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
44M&L for 2nd class hard wood 30 mm thick glazed and skeleton shutters open rebated and prepare to received glass, gauge etc divided into squares with plain chamfered or rounded mitred and sash bars any number edges of framing plain chamferedor rounded fitted with cut and mitredbeads for securing glass etc sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) and fitted to wooden chowkhat, complete all as per specified and directed.
45M&L for 2nd class hard wood 35 mm thick glazed and skeleton shutters open rebated and prepare to received glass, gauge etc divided into squares with plain chamfered or rounded mitred and sash bars any number edges of framing plain chamferedor rounded fitted with cut and mitredbeads for securing glass etc sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) and fitted to wooden chowkhat, complete all as per specified and directed.
46S & F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples to wooden shutters, complete all as specified and directed.
47S&F 100mm size MS butt hinges, medium weight, cold rolled and fixed complete all as specified and directed.
48S&F 75mm size MS butt hinges, medium weight, cold rolled and fixed complete all as specified and directed.
49S&F 150mm size, extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
50S&F 150mm long aluminium anodised tower bolt of extruded section complete all as specified and directed.
51S&F 125mm size, extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
52S&F 125mm long aluminium anodised tower bolt of extruded section complete all as specified and directed.
53S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
54M & L for preparation of old wooden surfaces of any description over 10cm width or girth applying two coats of synthetic enamel paintcomplete all as specified and directed.
55M&L for 2nd class hard wood in scantling, wrought timber fixed as in framed and fixed in any position complete all as specified and directed.
56M&L for 2nd class Hard wood plain fillets square rectangular or triangular in section clean sawn cross sectional area exceeding 6.0 sqcm & not exceeding 13sqcm screwed with nails complete all as specified and as directed.
57Dismantling wall and ceiling boards (Fibre, pulp, insulation etc.) of any thickness including cover fillets complete all as specified and directed.
58M&L for 6 mm thick plywood (6 Nos ply) grade BWR, type BB fixed to timber frame work with screws complete all as specified and directed.
59Dismantling boarding, any description, fixed in any position with nails/ screws complete all as specified and directed.
60M&L for 25mm thick, second class hardwood boarding, plained one side and tongued, grooved or rebated in floor and skirting and fixed with nails/ screws complete all as specified and directed.
61M&L for 25mm thick, second class hardwood boarding, as in weather oarding clan sawn thickness 20mm to 25m and rebated on thick edge to give 20mm laps and fixed plained one side and tongued, grooved or rebated in floor and skirting and fixed with nails/ screws complete all as specified and directed.
62S&F factory made reinforced PVC septic tank of capacity 2000 litres for 25 users, cleaning period 2 years and laying in existing position after demolition of old unserviceable septic tank as per manufacturers instructions complete all as specified and directed.
63Demolition of cement concrete (unreinforced) in ground floors or pavings not exc. 15 cm thickness (below or above GL), complete all as specified and directed.
64M & L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in floor complete all asspecified and directed
65M & L for 75mm thick plain cement concrete 1:2:4 type C-2 (using 20 mm graded stone aggregate) as in floor complete all asspecified and directed
66Taking down carefully point wiring (light, fan, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket etc and making good disturbed surface of wall / floor etc. complete all as specified and directed.
67Taking down / out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, etc. of any descriptions, laid in trenches and /or fixing with walls /poles including segregating of serviceable materials viz bricks, cables,etc. and kept in Safe custody for re-use, complete all as specified and directed. (NOTE : Earth Work shall be measured and paid separately under relevant Items here-in-before.)
68Supply, laying & testing of cable in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 16 sqmm 4 core, complete all as specified and directed.
69Excavation in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth,and getting out in Soft / Loose Soil, complete all as specified and directed.
70Returning, filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm. complete all as specified and directed.
71Removing excavated materials not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point, complete all as specified and directed.
72M&L for Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. (NOTE : For the purpose of payment, punning thickness of Sand cushioningshall only be measured and paid).
73Supply and laying un-reinforced precast concrete cable cover of size 250mm x 150mm x 40mm complete all as specified and directed.
74Relaying only old un-reinforced precast concrete cable cover in trenches for underground cable protection (serviceable materials obtained from item here-in-before) complete all as specified and directed.
75M & L for point wiring with 1.5 sqmm FRLS grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694drawn through and includingPVC cassing and capping (not less than 20 mm wide) complete with all accessoriesincluding PVC board/ box of suitable size for mounting of switches, sockets, regulators etc including 1.5 sq mmstranded copper conductor cable FRLS grade PVC insulated and unsheathed as earth continuity conductor for one lightpoint controlled by one way switch complete by maintaining the colour code complete all as specified and directed.
76All as per Ser item No 75 here-in-before but for 5 amps socket point on independent board complete all as specified and directed.
77All as per Ser item No 75 here-in-before but with 2.5 sqmm cable for 15 amps socket outlet on independent board, using 2.5 sqmm earth continuity conductor complete all as specified and directed.
78Supply and fixing switch piano flush type, 6 Amps 240 volts single pole one way complete all as specified and directed.
79Supply and fixing switch piano flush type, 15/16 Amps 240 volts single pole one way complete all as specified and directed.
80Supply and fixing socket outlet, 3 pin 6 Amps, flush type complete all as specified and directed.
81Supply and fixing socket outlet 15/16 Amps, 6 in 1, flush type complete all as specified and directed.
82Supply and fixing in repairs Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
83S & F 10W LED bulb complete all as specified and directed.
84Supply and fixing SP&N DBs, double door, 240 volt, 8 way complete all as specified and directed. MAKE:- Legrand Cat part No. 5076 11 or equivalent of make L&T/ Siemens as approved by GE.
85Supply and drawing submain wiring with two runs of single core 1.5 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unsheathed conductor drawn into PVC casing and caping and all necessary fittings including 2X4 sqmm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size & situation and making good disturbed surface complete all as specified and directed. NOTE:- (i)Extra length of cables/ wire required for connection to MCBs/DBs shall not be measured under this items. (ii) Cuttings / chasing of wall etc and making good the disturbed surface shall be measured and paid separately. (iii)Six runs of cable 4 Sqmm shall be measured as one RM of sub main wiring.
86Supply and drawing submain wiring with two runs of single core 2.5 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unsheathed conductor drawn into PVC casing and caping and all necessary fittings including 2X4 sqmm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size & situation and making good disturbed surface complete all as specified and directed. NOTE:- (i)Extra length of cables/ wire required for connection to MCBs/DBs shall not be measured under this items. (ii) Cuttings / chasing of wall etc and making good the disturbed surface shall be measured and paid separately. (iii)Six runs of cable 4 Sqmm shall be measured as one RM of sub main wiring.
87S&F MCB single pole, 240 volts, 5 - 32 Amps, 10 KA, C Curve complete all as specified and directed.
88S&F MCB single pole & neutral 240 volts 32Amps, C Curve complete all as specified and directed.
89S&F LED light fitting 20 watts, 4 feet long suitable for 230 volts 50 Hz AC supply complete with all accessories including connecting up with three core flexible copper conductor cable of size 0.5sqmm (nominal area) complete all as specified and directed.
90S&F LED light fitting 10 watts, 4 feet long suitable for 230 volts 50 Hz AC supply complete with all accessories including connecting up with three core flexible copper conductor cable of size 0.5sqmm (nominal area) complete all as specified and directed. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule "A"/BOQ.