Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-11-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-11-2022 |
| Sl. No. | Item Description |
| 1 | M&L plantation of Pulmeria Alba 2-3\" height tree saplings including necessary excavation of earth pit, application of vermicompost, Neem compost, cow dung, C bone meat powder and Chloropyrophosdust including 3 months maintenance etc complete all as directed by Engr-in-charge. |
| 2 | M&L plantation of Delonix Regia 2-3\" height tree saplings including necessary excavation of earth pit, application of vermicompost, Neem compost, cow dung, C bone meat powder and Chloropyrophos dust including 3 months maintenance etc complete all as directed by Engr-in-charge |
| 3 | M&L plantation of Jacaranda Pink, Blue or Re 2-3\" height tree saplings including necessary excavation of earth pit, application of vermicompost, Neem compost, cow dung, C bone meat powder and Chloropyrophos dust including 3 months maintenance etc complete all as directed by Engr-in-charge |
| 4 | Supply and planting of flowering Curtain creeper, Vernonia Creeper parabel 2 to 5 ft long tree saplings including necessary excavation of earth pits, application of vermicompost, neem compost cow dung, bone meat powder and chloropyrophos dust including 3 months maintenance etc complete all asdirected by Engr-in-charge |
| 5 | Supply an fixing stainless steel bench grade 304 of 1350mm length, 860mm height and 460mm sitting (52 Kg each) etc complete all as approved by Engr-in-charge |
| 6 | M&L Granite 18-20 mm thick (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm screed bed CM 1:4 complete all as specified. |
| 7 | M&L Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4)ncluding pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 8 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations cpmplete all as specified. |
| 9 | M&L Cement concrete 25 mm thick type B- 0, 1:2:4 (12.50mm graded aggregate) as in floor complete all as specified. |
| 10 | M&L Cement concrete 75 mm thick type D-2, 1:4:8 (40 mm graded aggregate) in floor complete all as specified. |
| 11 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified. |
| 12 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering Complete all as specified. Note:- Measurements for items shall be those after consolidation |
| 13 | Material and labourVitrifiedpaver tiles10 mm thick (square/ rectangular) polishedarea of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to matchover and including15 mm thick screed bed in CM 1:4. (Sample as approved & Kept in GE\"s sample room) |
| 14 | Description all as item No 13 but as in vertical surfaces dado/skirting over and including a backing coat of CM 1:4, 10 mm thick complete. |
| 15 | Surface excavation n exc 30cm deep and averaging 15 deep and getting out in any type of soil and etc complete all as specified and as diercted |
| 16 | Excavation in trenches, n. exc. 15m wide and n.exc 1.5m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc exc 10 Sqm on plan and nxexc 1.5m in depth and getting out any type of soil etc complete and all as specified and as directed. |
| 17 | M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass-concrete etc complete and all as specified and as directed. |
| 18 | M&L for 50mm thick PCC type B1, 1:2:4 (20mm grade aggregate) as in floor etc complete. |
| 19 | M&L for 100mm thick PCC type B1, 1:2:4 (20mm grade aggregate) as in floor etc complete. |
| 20 | Material and labour glazed ceramic colouredDigital tiles in vertical surface300x200x7 mm thick, set and jointed in neat cement slurry and pointed white or colored cement to match the surface over and including 10 mm thick CM 1:4 all as specified. (Sample as approved & Kept in GE\"s sample room) |
| 21 | Material and labour for Chequered cement concrete tiles 30cm x30cm x 25mm thick, with greay cement and pigment, set, jointed and pointed in neat cement slurry in floors and laid over and including 20mm thick screed bed in CM 1:4 etc complete all as specified and as directed. |
| 22 | Material and labour for Providing, cement concrete 1:2:4type B-1 (using 20mm graded aggregate ), copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering,slightly rounded or chamfered angles and throating, all as specified and as directed. |
| 23 | Removing excavated material in exc 250m but n exc 500m and adepositing where directed at a level not exceeding 1.5m above the starting point etc complete all as specified. |
| 24 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 25 | M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410-W Gde E-250 quality A, complete all as specified and as directed by Engineer-in-charge |
| 26 | Dismantiling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. |
| 27 | S&F Pre- painted galvalume aluminum zinc coating (AZ-150 Micron) GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 28 | S&F Pre-painted galvalume aluminum zinc coating (AZ-150 Micron) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 29 | Supply and fixing GI snap grid frame work (Grid size 605cm x 605cm) for false ceiling consisting of main runner \"T\" of size 24mm x 32mm and 0.3mm thick , Secondary runner \"T\" of size 4mmx25mm and 0.3mm thick,GI angle24mmx24mm and 0.4mm thick,Bottom exposed capping of width 24 mm of all T-sections shall be of 0.25mm thick PPGI, hot dipped galvanised steel with zink coating not less than 120gm / Sqm, ceiling grid system duly suspended by 4mm dia GI wire hanging from existing purlins /roof slab with butterfly clips including Gypsum ceiling tiles of size 595 x 595 x 7 mm laminated with 0.07 mm thick polyvinyl film on the face side and 10 micron metalized polyester film on the back side fixed on GI snap grid including taking down of old u/s material complete all as specified and directed by Engr-in- Charge. |
| 30 | Taking down cement plaster on brick or stone walls or stone walls etc, including raking out joints, hacking for key, scrubbing down with water, etc. |
| 31 | Material and labour for rendering 10 m thick on fair faces of brick or concrete surfaceceilings, in cement mortar 1:3, rendering is to be finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge. |
| 32 | Material and labour for rendering 15 m thick on fair faces of brick or concrete surface walls, in cement mortar 1:4 , rendering is to be finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge. |
| 33 | Material and labour rendering 15 m thick on other than fair faces of brick or concrete surface walls, in cement mortar 1:6, rendering is to be finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge. |
| 34 | M&L for repairing of concrete surfaces such as balconey, chajjas, upward or downward facias, column, Piller, ceiling and similar items with plain cement concret 1:2:4 type B-0 & rendering any thickiness in CM 1:3 without using extra cement finished even and fair andtaking down or dismantiling as required at site complete all as specified and directed. |
| 35 | Taking down chowkats or frames (without taking down shutter from the frame) not exceeding 1.5 Sqm each complete all as specified. |
| 36 | Taking down chowkhats or frames (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site complete all as specified. |
| 37 | Material & labourfactory made steel windows double shutter box type, outer frame made out of ERW TUBE \"P\" section(65x45x25mm) and shutters of ERW TUBE \"P\" section (50x35x20mm) operable shutters side hung includding pistol hinges with two Nos of MS Tower bolts 150mm size on each shutter steel handle and stopper of \"Z\" section as specified complete with sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitabel fittings/openning for cooler/AC where required .Steel windows will be double shutter external glazed and internal wire gauzed complete all as specifed and as per Drg No CEPZ/TD-324/07 1/3 to 3/3 all as specified and directed by Engr-in-Charge.NOTE: The quoted rate against the above item shall also include (i) for Provn of one shop coat of zinc chromate primer on all exposed steel surfaces and one coat of coal tar on the ends of steel frame in contact with brick/conc surface (ii) 04 Nos MS Steel lugs of 20x5mm MS flat 20cm long over all welded to frames (iii) PCC block for embedding lugs. |
| 38 | Material & labour for framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framedbalusters; walk ways, railings, framework of water tanksand similar work conforming to Fe.290.Gde-E-165 |
| 39 | Supply and fixing Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples. |
| 40 | Supply and fixing Sheet glass ordinary quality 4mm thick and glazed with oil putty or any types ofbeads in square n.exc 0.5 Sqm each pane in any type of frame of Iron/ Steel/ Wood/ Aluminium as requiredat site complete all as specified. |
| 41 | Demolition of brick work built in cement mortar including all quoin, arches pillars but excluding ashlar facing dressed stone work and precast concrete article complete all as directed. |
| 42 | Material and labour for brick work with subclass \"B\" bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified. |
| 43 | Material and labour for brick work with subclass \"B\" bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 but except bricks complete all as specified. |
| 44 | Material and labour for brick work with subclass \"B\" bricks, old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified. |
| 45 | Preparation of new or previously untreated steel surfaces of any description not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat ofzink chromeprimer including necessary rubbing with sand paper or grinded by hand grinder to achieve smooth and even surface. |
| 46 | Material and labour for applying two coat of synthetic enamel paint to old painted steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth and apply putty and primer where required complete all as specified. |
| 47 | M&L for preparation of old decorated concrete/ plastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applying two coat of oil bound distemper on old decorated wall surface including two coats of wall care putty of 1 to 2 mm thick on uneven surface as and where required. |
| 48 | Material ad labour for preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over two coat of wall care putty of 1 to 2 mm thick and one coat of primer complete all as specified. |
| 49 | Material and labour for applying three coats ofwhite wash on newsurfaces of ceiling including preparation of surfaces etc complete all as specified and directed. |
| 50 | Material and labour for applying two coats ofwhite wash onold surfaces of ceiling including preparation of surfaces etc complete all as specified and directed. |
| 51 | Preparationof newplastered/ concrete surfaces of walls to achieve smooth and even surfaceandapplying two coats of cementpaint over and including one coat of primer complete all as specified and directed. |
| 52 | Preparation of old plastered surfaces of wall and applying two coats of cement base paint complete all as specified. |
| 53 | M&L for preparation of old decorative plastered/concreat surface of wall, chajja, facia, face of columns, beam ect by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applyingone coat of weather proof exterior emulsion (APEX) with necessary scaffoding up to 4th storey, including necessary filling of wall care putty on uneven surface as and where required all as specified. |
| 54 | Demolition of cement concrete (unreinforced) ground floor to 4th floors and pavings n exc 15 cm thickness (below or above ground level ) and removingthe rubbish from the work site out side defence premises complete all as specified. |
| 55 | M&L for plain cement concrete(1:2:4) type B-1 (using 20mm graded crushed stone aggregate ), nominal mix as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified. |
| 56 | M&L for40 mm thick plain cement concrete 1:2:4 mix, Type B1 (using 20mm graded stone aggregate) as in floors finished even and smooth without using extra cement complete all as specified and directed. |
| 57 | Supply only glass dividing strips 38 mm width & 3 mm thick, inserted in position, conform to design. |
| 58 | Demolition of Reinforced cement concrete of any description and in any position and removing the rubbish from the work site out side defence permises. |
| 59 | Material and labour for Reinforced cement concrete, 1:2:4 (Nominal Mix ) as in slabssupportedon walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the likeall as specified and directed. |
| 60 | Material and labour for form work to soffits of suspened slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 61 | Material and labour for TMT steel bars 10mm dia and above as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia), all as specified and directed. |
| 62 | M&L for welding in repairs n. exc 2.5cm in length, thickness of metal to be welded exc 6mm but n exc 9mm, complete all as specified and direcetd by Engineer-in-charge. |
| 63 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushingsurface with neat cement slurry with 3.0 kg of cement per sq. metre, removing serviceable tiles to store and rubbish off the cantt area complete all as directed. |
| 64 | Material and labour Non - skid Digital Ceramic joint less coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match the surface over and including 15 mm thick screed bed in CM 1:4. (sample as approved & kept in GE\"s sample room) |
| 65 | Description all as item No 64 but as in vertical surfaces dado/skirting over and including a backing coat of CM 1:4, 10 mm thick complete. |
| 66 | Material and labour machine cut kota stone slab (Minimum size shallbe 550x550 mm) flooring18 - 20mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirrorpolishing complete,laid over and including screed bed or bedding layer of 20 mm thick in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge. |
| 67 | Material and labour machine cut kota stone 10-12 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishing set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/colour of tiles over and including 10 mm thick rendering in cement mortar 1:4, as in vertical surfaces complete all as specified and as directed by Engineer-in-charge. |
| 68 | M&L for 75mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement, laid in bays and including filling of joints with bitumen mastic comprising one part of bitumen 85/25 mixed with three parts of coarse sand by weight complete all as directed. |
| 69 | M&L framed work such as Gates / doors section with gusset plates, rails braces etc complete drilling welding for fixing hanging or sliding with and including either hooks and hinges(Tee ,Angle MS tube Flat iron channel,) shouldered, riveted, or welded conformingto-Fe-290 (Gde-E-165) |
| 70 | S&F joist channel angle or tee section, fixed in purlin rafter cleat, support etc incl welding, riveting etc conformingto Fe-410-W Gde E-250 quality A, all as directed by Engr-in-charge |
| 71 | M& L 1.25 mm thick mild steel plain black sheet covering door shutters / gates welded /riveted including bending turning up stopped ends outlet etc. |
| 72 | Supply and fixing aluminium powder coatedframe of hollow section 63.5 mmx38.1 mm thickness not less than 1.53 mm fixed type partition with glazing clips rubber gasket/rubber beading and screws for fixing of glass/ACP inserts complete all as directed by Engr-in-charge and as approved by GE. Note : Glass/ACP sheet inserts shall be measured and seperately under respective items. Note :-All aluminium doors//windows/ventilators/fixed glazing/partition section, grills and builder’s hardware (except hinges) shall be powder coated in approved colour. Thickness of coating shall not be less than 50 micron. |
| 73 | Supply and fixing Sheet glass ordinary quality 5.5mm thick andin square n.exc 0.5 Sqm each pane in any type of frame of Iron/ Steel/ Wood/ Aluminium as requiredat site complete all as specified. |
| 74 | Supply and fixing Aluminium powder coated door with shutter & Chowkat frame of hollow section 63.5 mm x 38.1 mm thickness not less than 1.53 mm including aluminium anodised powder coated of hollow section glazed shutter of stiles size 85mm x 44.5mm thickness not less than 1.53 mm having grooves for aluminium beading and top rail of hollow section 83.5mm x44.45 mm thickness not less than 1.5 mm, lock rail of hollow section 83.5x44.45 mm thickness not less than 1.5 mm and bottom rail of hollow section 114.3mm x 44.45 mm thickness not less than 1.5 mm, one derived handle 300mm long, 100 mm long butt hinges or aluminium floor spring, tower bolt 150 mm, aluminium mortice lock rail 65 mm 4 levers of godrej make and glazing with selected quality tinted glass 5.5 mm thick or panelling with ACP sheet and cleat, rubber packing, aluminium beading including aluminium harware fitting complete all as specified and as directed by Engr-in-Charge and approved by GE.Note :-All aluminium doors//windows/ventilators/fixed glazing/partition section, grills and builder’s hardware (except hinges) shall be powder coated in approved colour. Thickness of coating shall not be less than 50 micron. |
| 75 | M&L for 75 mm thick PCC(1:3:6) type C-2 , using 40 mm graded crushed stone aggregate as in sub base of floor. |
| 76 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. |
| 77 | Dismantling timber scantlings 40 sq. cm and over in section, in any position (unframed work). |
| 78 | Dismantling timber scantlingsin fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section.(unframed work). |
| 79 | M&L Cement concrete 1:3:6 (Using 40 mm graded crushed stone aggregate) type C-2 in foundations, filling and mass concrete |
| 80 | S&F Galvanised steel tubes, 15 mm bore, medium grade with all fittings including bitumen coating complete all as specified. |
| 81 | S&F Galvanised steel tubes, 20 mm bore, medium grade with all fittings including bitumen coating complete all as specified. |
| 82 | Supply and fixing Rotational moulded polyethylene water storage tanks of1000 litres capacity, (cylindrical vertical with closed top) triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specified. |
| 83 | M&L mild steel Framed work as in door or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Dorrs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging dooe fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of Fe 410-W (Gde E- 250) quality complete all as specified. |
| 84 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed. |
| 85 | S&F steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and thickness of laths 1.25 mm and one shop coat of primer, erected in position as indicated, push pull or manual type complete all as specified and as directed by Engr-In-Charge. |
| 86 | S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed. |
| 87 | S&F ball bearing for rolling shutters complete all as specified and as directed. |
| 88 | Taking down carefully aluminium conductor point wiring (light, fan, socket, power socket) complete fitting such as swithes, sockets, lamp holder, utility light fitting, fan regulator etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed. |
| 89 | Taking down ofunsvMCB DB SPN /TPN along with MCB\"s |
| 90 | Taking down ofunsvSub main wiring of any size |
| 91 | M & L for complete point wiringwith 1.5 Sqmm single core multi stranded copper conductor FRLSHinsulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn in and including concealed PVC rigid conduit medium gradeISI marked after cutting chases in wall , plastering after concealing conduit , including modular galvanisedflush boxes of suitable size and white cover plate with frame as per relevant ISfor mounting modular switches, sockets, fan regulators etc complete all as specified and as directed for the following :-(a) One Light / Fan point controlled by one, one way switch 6 Amp complete |
| 92 | (b) One 3 pin socket outlet 6 amp independent |
| 93 | (c) One 3 pin socket outlet 6 amp same board |
| 94 | All as per srl item No 91 above but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire. |
| 95 | Supply and fix modular type switch, one way 6 Amps , 1 module complete all as specified and directed. |
| 96 | Supply and fixmodular type socket 5 pin, 6 Amps 2 module complete all as specified and directed. |
| 97 | Supply and fix modular type switch, one way 16 Amps, 1 module complete all as specified and directed. |
| 98 | Supply and fixmodular type socket 5 pin, 6 A/16 Amps2 module complete all as specified and directed. |
| 99 | Supply and fix ceiling rose surface, backelite,three terminal, 240 volts complete all as specified and directed. |
| 100 | Supply and fix LED lightfitting 1 x 18Watt, 220V, AC decorative box type with driver, holder including LED Tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing arrengenment all as directed by Engr in chage.Note:- The LED batten and LED tube rod shall be of same make. |
| 101 | Supply and fix of lamp holder,PVC /Polycarbonate type with back plate for batten fitting . |
| 102 | Supply and fix LED lamp suitable for B22 holder of capacity 7 Watt. |
| 103 | Supply and fix energy saving new generation 10W LED IP65 bulk head luminaire with opal diffuser complete all as specified and directed. |
| 104 | Supply and fixDistribution Board (SPN)double door 12 Way and should be IP 43protected with Copper Bus bar 100 Amp rated, Earth Bar, neutral Bar Door Earthing. |
| 105 | Supply and fix MCB SPN complete 32 Amp with rupturing capacity 10 KA \"C\" series, complete all as specified and directed. |
| 106 | Supply and fix MCB Single pole 6 to 32 Amp with rupturing capacity 10 KA \"C\" series, complete all as specified and directed |
| 107 | Supply and fix sub main wiring with single core cable 2x 6 sq mm FRLSHinsulated Unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed)medium grade alongwith 1 x 6 Sq mm FRLSHinsulated unsheathed copper conductor cable as earth wire connected with main earth dolly including chesing, cutting & making good to match with the existing surface complete all as specified and directed. |
| 108 | Supply and fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and fixing by clamp and anchor fasner all as directed. |
| 109 | Supply and fix sheet metal enclosure MCCB DB VTPN double door 4 way suitable for 415 V with 200 amps rated bus bar including flushed on walls and making good disturbed surfaces including taking down the old DB suitable for MCCB 4 Pole as incomer all as specified and as directed. |
| 110 | Supply and fix 4 Pole MCCB 100 Amp, 415 Volts with rupturing capacity 16 KA , complete all as specified and directed |
| 111 | M & L for complete earthingwith galvanised mild steel earth plate electrode of size600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron orearth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion. |
| 112 | Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 25 sq mm 4 core cable confirming to IS-7098 Part-I (1988) with latest ammendments of sizes. |
| 113 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specifieds and directed. |
| 114 | Removal of excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specifieds and directed. |
| 115 | Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trench complete all as specifieds and directed. |
| 116 | Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sub class \"B\" bricks complete all as specifieds and directed. |
| 117 | Material and labourfor GI pipe light grade for road crossing / on wall / on pole with fixed clamps, nuts, boltsfor cableprotection of size40 mm dia complete all as specifieds and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail