| 1 | S & F Solid PVC Wall Lining consisting of 5mm thick wood grainprinted PVC sheet used instead of plaincolour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and as directed. |
| 2 | 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and as directed. |
| 3 | Demolition of cement concrete (unreinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 4 | M&L for Vitrified ceramic light shade tiles, 10 mm thick (square/ rectangular) polished ,area of each tile not exc. 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar 1:6complete all as specified and as directed. |
| 5 | M&L for 25mm thick Cement concrete 1:2:4 type B-O(using 12.5mm graded aggregate) as in flooring, finished surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 6 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 7 | Taking down complete removal of existing treatment, washing, rubbing down and stopping of distempred and painted surfaces on walls complete all as specified and as directed. |
| 8 | M&L for taking down cement plaster, any description, including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 9 | M&L for rendering 15mm thick in cement mortar 1:6 onsurfaces other than fair face of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed. |
| 10 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over 2mm thickplaster of paris putty over plastered surface to prepare surface even and smooth complete all as specified and as directed. |
| 11 | M & L for preparing old plastered surfaces and applying two coat of oil bound distemper on wall over 1mm thick birla white putty and making surface smooth having no sign of brush marks complete all as specified and as directed. |
| 12 | M&L for preparing old plastered surfaces of ceilings and applying two coat of white wash complete all as specified and as directed. |
| 13 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. |
| 14 | S&F5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. |
| 15 | S&F GI Powder coated GI Snap Grid Frame Work of size 605x605mm as in False Ceiling with supported hanging of Mild Steel Rod of\"J\" Bolt, complete all as specified and as directed. |
| 16 | S & F in repairs4 mm thick designer Fibre cement board ( E-board) Tile of size 595x595 mm of approved texture, blossom, fixture and primerfinished complete , complete all as specified and as directed. |
| 17 | M&L for Glazed ceramic colored tiles in vertical surface 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchoverand including 10mm screed bed of mortar of cement plaster (1:4) complete all as specified and as directed |
| 18 | Taking up or down cast iron water mains 80 mm dia bore (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 19 | Taking up or down cast iron water mains 100 mm dia bore (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 20 | Taking up or down cast iron water mains 150 mm dia bore (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 21 | Taking up or down steel tubing and connections, including fittings to store GI tubing 20 mm bore any type complete all as specified and as directed. |
| 22 | Taking up or down steel tubing and connections, including fittings to store GI tubing 25 mm bore any type complete all as specified and as directed. |
| 23 | Taking up or down steel tubing and connections, including fittings to store GI tubing 40 mm bore any type complete all as specified and as directed. |
| 24 | Taking up or down steel tubing and connections, including fittings to store GI tubing 50 mm bore any type complete all as specified and as directed. |
| 25 | Supply , laying , jointing of GI Pipe medium gradeof size 20 mm dia including jointing material/ ISI mark GI fittings in trenches complete all as directed. |
| 26 | Supply , laying , jointing of GI Pipe medium gradeof size 25 mm dia including jointing material/ISI mark GI fittings in trenches complete all as directed. |
| 27 | Supply , laying , jointing of GI Pipe medium gradeof size 40 mm dia including jointing material/ GI fittings in trenches complete all as directed. |
| 28 | Supply , laying , jointing of GI Pipe medium gradeof size 50 mm dia including jointing material/ GI fittings in trenches complete all as directed. |
| 29 | Supply , laying , jointing of GI Pipe medium gradeof size 80 mm dia including jointing material/ISI mark GI fittings in trenches complete all as directed. |
| 30 | M & L for ductile iron pipes of 150 mm dia with spigot and socket ends centrifugal cast K-7as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches complete all as specified and as directed by Engineer-in-charge. |
| 31 | M & L for ductile iron pipes of 100 mm dia with spigot and socket ends centrifugal cast K-7as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches complete all as specified and as directed by Engineer-in-charge. |
| 32 | Supply and fixing gun metal globe or gate valve with iron wheel head screwed both ends for GI pipe of size 20 mm diacomplete all as specified and as directed. |
| 33 | Supply and fixing gun metal globe or gate valve with iron wheel head screwed both ends for GI pipe of size 25 mm diacomplete all as specified and as directed. |
| 34 | Supply and fixing gun metal globe or gate valve with iron wheel head screwed both ends for GI pipe of size 40 mm diacomplete all as specified and as directed. |
| 35 | Supply and fixing gun metal globe or gate valve with iron wheel head screwed both ends for GI pipe of size 50 mm diacomplete all as specified and as directed. |
| 36 | Supply and fixing sluice valve both end flanged type of class PN 1.6including all fixing arrangement of size 150 mm dia bore pipe complete all as specified and as directed by Engr-in-Charge. |
| 37 | Supply and fixing sluice valve both end flanged type of class PN 1.6 including all fixing arrangement of size 100 mm dia bore pipe complete all as specified and as directedby Engr-in-Charge. |
| 38 | Supply and fixing sluice valve both end flanged type of class PN 1.6 including all fixing arrangement of size 80 mm dia bore pipe complete all as specified and as directedby Engr-in-Charge. |
| 39 | Supply and fix Valve, reflux, with by-pass Arrangement, 150 mm (6”) dia complete all as specified and as directed. |
| 40 | Supply and fix in replacement Cast Iron Bendsfor Spigot Socketed Pipes (anytype,radiusand angle) tapers any type,(straight,bend,increasing,decreasing or double socket etc.)Teepiecessinglebranch.\"Y\"junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc upto 150mm dia pipes complete all as specified and as directed. |
| 41 | Supply and fix in replacement Cast Iron Bends , Tapers,Teepieces (single & double branch) for Flanged Pipesanytypeandangle/radiusandstraight connecting pieces but all ends flanged upto 150mm dia pipes complete all as specified and as directed. |
| 42 | Supply and fix in repair Cast Iron Connecting pieces one end flanged and othersocketor spigot and bell mouth piecesone endflangedother end taperingas bell mouth upto 150mm dia pipes complete all as specified and as directed. |
| 43 | M&L for run lead joints for 150mm dia of cast iron Spun pipes/fittings including burning out old joints and recovering leadcomplete all as specified and as directed. |
| 44 | M&L for run lead joints for 100mm dia of cast iron Spun pipes/fittings including burning out old joints and recovering leadcomplete all as specified and as directed. |
| 45 | M&L for run lead joints for 80mm dia of cast iron Spun pipes/fittings including burning out old joints and recovering leadcomplete all as specified and directed.Note for ite nos 43 to 45 :-The Excavation in muddy soil including removing water by any means for supply and fixing Run lead joint after removing jointing material cocking the requiredmaterials properly complete will includein quoted rates in the item itself. |
| 46 | M&L for Drilling and tapping cast iron water mains for branch connection of the internal dia 20mm including clamp piece and nuts and bolts all as specified and as directed. |
| 47 | Taking out of sluice valves/ NRV/ Reflux valvefrom existing pipe linesupto 80/100/150 mm bore complete all as specified and as directed. |
| 48 | Taking out of Gate valve20 to 50 mm bore complete all as specified and as directed. |
| 49 | Excavation intrenches in soft loose soil not exceeding 1.5 mtr vidse and not exc 1.5 mtr in depth for poles stays,cable and getting out complete all as specified and directed by Engr-in-Charge. |
| 50 | Returning filling in approved earth incl spreading leveling watering and welln ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge. |
| 51 | Removing excavated materials (surplus soil) to a distance exc. 50m and depositing where directed at a level n.exc 1.5 m above the starting point all as specified and directed by Engr-in-Charge. |
| 52 | M&L for cutting existing CI/DI pipe 150mm bore and reducing to required length and making connection with new pipe line using requisite tee,reducer or fittings/joints complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L for cutting road/path for laying of DI pipe line upto 150mm and making good to the disturb area as existing complete all as specified and directed by Engr-in-Charge. |
| 54 | M&L for brick masonary valve pit (type B) of size 90 x 90x 90 cm cm (internal of chember ) MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm 6 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directedby Engr-in-Charge. |
| 55 | Taking down carefully old copper/alluminium point, wiring (light, fan, socket or power) complete, including fitting such as switches, ceiling roses, pendants, regulator socket tube light fitting of any type, Bulk head fittingetc segregation serviceable fitting/fixture and keep them safe custody for reuse and removing materials from the site and making good disturbed surface of walls&floors etc as per existing specification complete all as specified as directed. |
| 56 | Taking down old unserviceable sub main wiring any size/core/type of copper/alluminium conductor.including making good the disturbed surfaces and removing materials from the site of work complete all as specified as directed. |
| 57 | Taking down ofexisting old unserviceable distribution board including MCB/MCCBcomplete all as specified and as directed. |
| 58 | M & L for concealed point wiring complete with PVC insulated and unsheathed flame retardant ( FR ) cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia,with MS terminal boxes for modular boxes (not less than 1.6mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dollywithsutable Size of modular plate and modular frame for any nos of moduleof approved make and colour including 1.5 sqmm multistranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries complete all as specified anddirected for the followings :- |
| 59 | (a) One light/fan point controlled by one switch |
| 60 | (b)One 3 pin socket outlet 5 amps on the same board with other switches. |
| 61 | (c) One 3 pin socket outlet, 5amps, independent board with other switches. |
| 62 | All as per item No 58 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant low smoke ( FRLS ) cable for 1 5 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified andas directed. |
| 63 | M&L forsub main wiring with PVC insulated, fire retardant (FR), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4 sqmm (Nominal area) drawn into existing / newconduit of any size and type/ casing-caping with and including one run of2.5 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green coouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note: (i)Conduit andaccessories shall be deemed to be excluded in the quotedrateand it is separately measuredby contractor. |
| 64 | All as per item No 60 here in before but 4x4.0 sq. mm + 2x2.5 sq. mm earth wire complete all as specified and as directed. |
| 65 | M&L for Regid non-metallicPVCconduit25 mm(external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etccomplete all as specified andas directed |
| 66 | All as per item No 62 here in before but 20mm dia complete all as specified and as directed. |
| 67 | S&F modularswitch 1 Way6 Amp , combined 2 module complete all as specified and as directed. |
| 68 | S&F Modular socket 6A - 2/3 pin combined 2 module complete all as specified and asdirected. |
| 69 | S&F Modular socket 2 in 1, , 3 pin, 6/16Ampcombined 2 module complete all as specified and asdirected. |
| 70 | S&F modularswitch 1 Way16Amp ,combined 2 modulecomplete all as specified and as directed. |
| 71 | S&F modular electronic Fan step regulator, 120W - 2 module complete all as specified and as directed. |
| 72 | S&Fmodular metal Box & modular white cover plate with frame 3 modulecomplete all as specified and asdirected. |
| 73 | S&Fmodular metal Box & modular white cover plate with frame 6 modulecomplete all as specified and asdirected. |
| 74 | S&Fmodular metal Box & modular white cover plate with frame 8 modulecomplete all as specified and asdirected. |
| 75 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 76 | S&F sheet metal enclosure double door suitable for distribution boards when MCBs to be used having 200Amp rated bus bar 12ways singlepole and neutral 240 V complete all as specified and as directed. |
| 77 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of 4 poles and current carrying capacity 32A in the DB complete all as specified and as directed. |
| 78 | Supply and fixing 240V, 10 KA \"B\" curve miniaturecircuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 79 | S & Fmodular AC box with mini MCBa two pin and earth plug and socket complete with one single pole MCB 20A and 240V complete all as specified and as directed. |
| 80 | S&F telephonemodular socket with box complete all as specified and as directed. |
| 81 | Supply, installation and testing of Tripod maintenance free chemical earthing (3 set earthing inter connected to 1 test point with copper earth plate 90cm x 60 cm x 5mm each connected with common copper earth strip 50mm x 6mm brazed to all three down copper strip and connected to test point complete duly filled with highly conductive and anti corrosive compound fill upto height 1700mm anti corrosive component consist of require quantity having chemical composition Bentonite 40%, copper sulphate 10%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc shalphate 10%, Aluminium sulphate 10% duly surrounded by soil friendly backfill compound non soluble in water including connection with copper earth strip 50mm x 6mm, making PCC pit of size 30cm x 30cm x 30cm inner size in mix 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bar 4 Nos in both way with lifting hook made of 8mm dia bar and testing on completion to achieve value not less than 0.50 ohm complete all as specified as directed. Note Copper strip upto 7.5 mtr distance incusive in quoted rates. |
| 82 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 50mm x 6mm size copper strip complete all as specified and as directed. |