Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-11-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-12-2022 |
| 2 | 16-11-2022 | Corrigendum3 | Date | 26-11-2022 |
| 3 | 15-11-2022 | Corrigendum2 | Other | 21-11-2022 |
| 4 | 07-11-2022 | Corrigendum1 | Other | 21-11-2022 |
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting outin soft / loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m depth and getting out in soft /loose soil etc complete all as specified and directed |
| 3 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L for RCC (design mix) M-25 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed .Note - Reinforcement and form work shall be measured and paid separately. |
| 5 | M&L for RCC (design mix) M-25 using 20 mm graded stone aggregatesas in columns, pillars, piers, posts and struts and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 6 | M&L for RCC(design mix) M-25 using 20 mm graded stone aggregatesas in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 7 | M&L for RCC (design mix) M-25 using 20 mm graded stone aggregatesas in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and inshelves and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 8 | M&L for RCC(design mix) M-25 using 20 mm graded stone aggregates as in chajjas and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 9 | Mild SteelTMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 10 | Mild Steel TMT bar 5 mm dia and over up to and including 10 mm dia as in stirrups, spacers & binderscut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 11 | Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams etc and similar work, vertical or to batter for fair finished flat concrete surfaces complete all as specified and directed. |
| 12 | Form work to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal for fair finished concrete surface complete all as specified and directed. |
| 13 | Form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers,lintels, cantilevers, shelves,for flatfair finished concrete surfaces complete all as specified and directed. |
| 14 | Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for fair finished flat surface of concrete complete all as specified and directed |
| 15 | Form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofand sides of bands in walls, horizontal or sloping and similar work for fair finished concrete surface exc 10 cm but not exc 20 cm wide complete all as specified and directed. |
| 16 | Returning, filing in, including spreading, levelling, watering and well rammingin layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed. |
| 17 | Removal of excavated materials exceeding 1.5 Km but not exceeding 5 Km and depositing where directed complete all as specified and directed. |
| 18 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 19 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 20 | M&L for treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of perimeter wall complete all as specified and directed. |
| 21 | M&L for brick work using old size fly ash bricks built in cement mortar 1:4 , straight or curved on plan exc 6 m mean radius complete all as specified and directed. |
| 22 | M&L for brick work using old size fly ash bricks built in cement mortar 1:4 , straight or curved on planto any radiusin half brick thick wall complete all as specified and directed. |
| 23 | M&L for rendering on fair faces of brick workor concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 24 | M&L for preparation of new plastered surfaces of walls andfinishing new wall surface with acrylic smooth exterior paint of required shade(twocoat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over and including providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 25 | M&L for rendering 15 mm thick on other than fair face of brick works in CM 1:6 and to be finishedeven and smooth with out using extra cement complete all as specified and directed. |
| 26 | M&L for preparation of new plastered surfaces of walls and distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification (two coats on new work) over and including providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 27 | M&L for rendering 10 mm thickin CM 1:3 on fair faces of brick work or on concrete surface after dubbing out average 10 mm thick in CM 1:4 on ceiling (irregular face)finishing the surface even and smooth without using extra cement complete all as specified anddirected. |
| 28 | M&L for preparation of newly plastered surfaces of ceilings and apply three coat of white wash complete all as specified and directed. |
| 29 | M&L moorum/red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 30 | M&L Broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 31 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete/sub base of paving complete all as specified and directed. |
| 32 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in sub base flooring 75 mm thick complete all as specified and directed. |
| 33 | M & L for 38 mm wide plastic dividing strips, 1.5 mm thick inserted in position, conform to design complete all as specified and directed |
| 34 | S&F steel windows or ventilators fixed type with glazing bars complete all as specified and directed. |
| 35 | S&F 5.50 mm thicksheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 36 | M&L for 15 mm thick screed bed or bedding layer in CM 1:4 using WPC @ 3% by weight of cement or as per manufacturer instruction surface finished fair and even in roof complete all as specified and directed.Note: -WPC shall be measured and paid separately under respective items. |
| 37 | Supply only water proofing compound. |
| 38 | M&L for cleaning surfaces and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/Sqm including cleaning surface complete all as specified & directed. |
| 39 | M & L for applying cold bituminous primer @0.30 litre / Sqm conforming to IS-3384, laying APP polymeric modified membrane 3.5 to 4.00 kg /Sqm in weight with non woven polyester reinforcement and sealing all the overlap of 100mm in length and 100mm in width of membrane by torching the same as per manufacturer\"s instructions with gradual finish including applying two coats ofaluminimum paint etc, complete all specified and as directed. |
| 40 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate, 75 mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. |
| 41 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in floor, roof and walls of 160 mm bore of pipe etc complete all as specified and directed. |
| 42 | S&FPVC SWR bend any radius of size 160 mm bore complete all as specified and directed. |
| 43 | S&F stack clamps made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nut and securing ends of stays to wall or roof for 160 mm bore of pipe complete all as specified and directed. |
| 44 | S&F 1.25 mm thick of steel rolling shutters without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated,gear operated type with chain wheel and hand chain complete all as specified and directed. |
| 45 | S&F safety lever locks mild steel with four levers for rolling shutters complete all as specified and directed. |
| 46 | S&F ball bearing for rolling shutters complete all as specified and directed. |
| 47 | M&L for preparationof new or previously untreated surfaces of steel of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 48 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as incoping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 49 | M&L for Precast cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc),chullah hoods, chajjas, water troughs,mangers, shelves and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. |
| 50 | M&L for 20-25 mm thick machine cut and polished kota stone over and including 20 mm thick backing coat in CM 1:6 as in shelves, platform or similar works laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting grove in thewalls or laids on any supportincluding griding, rubbing and mirror polishing complete all as specified and directed. |
| 51 | M & L forglazed ceramic coloured tiles in vertical surfaces 300x200x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including backing coat of 10 mm thick in CM (1:4) complete all as specified and directed. |
| 52 | M&L for Vitrified ceramic tiles 9 to10 mm thick (Square / rectangular) light shade polished area of each tiles not exceeding 0.36 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified & directed. |
| 53 | M&L for Vitrified ceramic tiles 9 to10 mm thick (Square / rectangular) light shade polished area of each tile not exceeding 0.36 sqm as in skirting etc laid over and including backing coat or bedding layer of 10mm thick 1:4 cement mortar for laying wall/vertical tile, jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified & directed . |
| 54 | Preparation of dry concrete surface using mild scarification/ grinding equipment and remove any loose material, contaminations and laitance to provide a sound, fine gripping surface including cut 6 mm groove with 1 meter interval in both direction and clean the entire floor area using an powerful industrial vaccum cleaner complete all as specified and directed. |
| 55 | M&L for 5 mm (minimum thickness) polyurethane Flooring with applying medium to heavy duty, solid colour three component, water dispersed polyurethane based self smoothening floor 5 mm thickness (scratch coat +body coat) having scratch coat 1 mm thick and body coat 4 mm thick of M/s Fosroc Chemicals or other equivalent make ofM/s Apurva India limited Mumbai, M/s Sika India Pvt Ltd , M/s STP Ltd, M/s Choksey Chemicals Pvt Ltd,M/s Bostic India Pvt Ltd Complete all as specified and directed.Note :- All work to done by authorized OEM applicator only. |
| 56 | S & F GI Powder coated snap grid frame work of size 605x605 mm with main runner (32x24x6.5mm), cross tee (27x24x2.4mm) and moulding (19x19mm) for false ceiling including fixing arrangement with roofcomplete all as specified and directed. |
| 57 | M&L for 4 mm thick non asbestos fibre cement building boards in ceiling of size 600x600 mm fixed or laid/ inserted toGI/Aluminium framework with screwscomplete all as specified and directed. |
| 58 | M&L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 59 | S&F powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2 No) ,suitable handle (1 No) complete all as specified and directed. Note-Glass and other filling material in panels shall be measured and paid seperately |
| 60 | S&F Aluminium Sliding door single leaf with powder coated (minimum thickness of powder coating 50 micron) aluminium frame of section 62.5x37x1.5mm thick, shutter with bottom & top rail of section 112.50x 43x1.5mm thick and styles & middle rail of section 83x43x1.5mm thick with centrally locking arrangement with lock make of ‘GODREJ’ or ‘LINK’ 7 lever and self closing device with rebate includingjointingcleats, rubber beading andsupply & fixing of necessary builders hardware fittings such as200 mm stainless steel handles -02 Nos, 150 mm long aluminium anodized tower bolt - 02 Nos, rubber bushes etcin each shutter complete all as specified and directed. Note-Glass and other filling material in panels shall be measured and paid seperately |
| 61 | S&F pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including one shop coat of priming complete all as specified and directed. |
| 62 | S&F 30 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 63 | S&F 3.5 mm thicksheet glass, ordinary qualityfor aluminium frames fixed with aluminium cleat and rubber beading in square exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 64 | M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 65 | M&L Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 66 | M&L Brick work using old size sub class \"B\" bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 67 | Removal of excavated materials exceeding 250 m but not exceeding 500 m and depositing where directed complete all as specified and directed |
| 68 | Excavation in soft/loose soil for post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed. |
| 69 | M & L for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 70 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5cm long and5 to 10 mm dia of shank complete all as specified and directed. |
| 71 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming toFe -290 Gde E-165 complete all as specified and directed. |
| 72 | Supply only chain link MS galvanised fencing conform to IS:2721-2003, any mesh, size and type etc complete all as specified and directed |
| 73 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provision of binding wire complete all as specified and directed. |
| 74 | Mild SteelFe-410-W Gde E-250 quality-A or Fe-290 Gde E-165 round bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 75 | M&L for preparationof new or previously untreated surfaces of steel of any description, not exc 10cm in width or girth when unconnected with other painting and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 76 | Supply, install, testing and commissioning of factory made floor mounted LT Panel Out doortype CPRI approved (double door) made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilation, dust and vermin proof with ingress protection class IP-55 with front and rear opening and locking arrangement 415Volts, 3 phase, 50 Hz having aluminium bus bar & suitable cable gland of capacity 400 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit currentwith stand minimum 85 KA for one second complete connection from bus bar to breakers with size of bus bar links , panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS angle for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc.The panel board shall be powder coated and red oxided primed with including following accessories:-a)MCCB 250Amps, 25KA , 4 pole with thermal magnetic adjustable type 70-100%(Incommer)-01 Nob)MCCB 100 Amps, 16 KA , 4 pole with thermal magnetic adjustable type 70-100% (oot going)-01 Noc)MCCB 40 Amps,16 KA , 4 pole with thermal magnetic adjustable type 70-100% (outgoing)-04 Nos d) Spare for housing MCCB 63 Amp 4 Pole-01 No e)Cable Glands-6 Nos for incoming and outgoing cables of any size.f)Indicator Lamp RYB-1setg)LT Panel with busbar & inter connection-1 Job h) Multifunction meter with inbuilt selector switch- 01 No |
| 77 | Removal of excavated materials (soils) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. |
| 78 | M&L for laying of bricks locally available sub class \"B\" bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable prependicular to the direction of cablecomplete all as specified and directed. |
| 79 | M&L for local sand coushioning with dry and clean sand over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as specified and directed. |
| 80 | Supply, laying, testing ofcable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. |
| 81 | M&L for earthing complete with galvanised steel plate electrode of size 600mmx600mmx6 mm thick buried directly in ground (earth pit not less than 2.25 Meter deep below from ground level with top edge of the plate not less than 1.5 Meter below from ground level connected to glavanised iron strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steelconnected to earthing test point including excavation and earth work and disposal of surplus soil to a distance as directed including 40 mm GI tubing light grade and necessary fitting for protection of galvanised strip incl laying of charcoal dust and common salt ,15 mm thick plastering with CM (1:6) internally and upto 150 mm below ground level externally, PGI funnel with 20 mm dia GI pipe medium grade for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test including testing complete all as specified and directed. |
| 82 | M&L for point wiring complete withmulti stranded copper conductor 1.5 Sqmm sizePVC insulated unsheathed cable FR in and includingPVC conduit concealed type ISI marked not less than 20mm dia including 1.5 sqmm multi stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and 1.6 mm thick sunken pressed steelgalvanised terminal boxes with top cover 2.80 mm thick ISI marked plastic laminated hylam sheet of required colour for housing/ fixingswitches etc complete all as specified and directed for the following- |
| 83 | One light/fan/exhaust fan/wall mounted fan point controlled by one way 5 Amp switch. |
| 84 | One 3 pin/5 pin socket out let 5 Amp on independent board |
| 85 | All as per serial item no.82 above but for 3/5 pin socket outlet for 15 Amps on independent board with 2.5 sqmm PVC insulated unsheathed cable FR,in and includingPVC conduit ISI marked not less 20mm dia,including unsheathed single core multistranded copper conductor cable 1100 volts grade2.50 sqmm PVC insulated unsheathed multistranded copper conductor cable as earth continuity conductor complete all as specified and directed. |
| 86 | S&Fswitch piano,flush type 15Amp complete all as specified and directed. |
| 87 | S&Fsocket outlet 2 in 1, 3 pin, 5 and 15 Ampflush type complete all as specified and directed. |
| 88 | S&Fswitch piano, flush type 5 Amp single pole one way complete all as specified and directed. |
| 89 | S&F Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed. |
| 90 | S&F ceiling rose surface bakelite ISI Marked three terminal complete all as specified and directed. |
| 91 | Supply and fixing LED lights fitting 1x 20W, AC 220V, 50Hz with inbuilt driver of adequate capacity, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 92 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection GIbracket 40mm dia with clamps and nut bolts to fix on wall/pole of adequate size, complete all as specified and directed. |
| 93 | Supply and fixing LED luminaire 600 mm x 600 mm, 34/36 watt, 220 V AC recess mountingtype with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Havells cat part No PLUTONEO2X2PLR34WLED857S/ Crompton-cat part No LCTLRNE-36-FO-NW |
| 94 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200 mm sweep, BEE, 5 star rated motor complete all as specified and directed. Make Havells/Orient/Crompton. |
| 95 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed. |
| 96 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 380mm sweep 900 rpm with, blades, and frame and louver complete all as specified and directed. |
| 97 | Supply and fix wall mounted fan, AC single Phase. 230V of size 450mm sweep with, blades, and frame complete all as specified and directed.Make Havells/Orient/Crompton. |
| 98 | M&L for wiring for circuit/submain wiring alongwith earth wire with size 2x6.0 sq. mm + 1x6.0 sq. mm earth wireof FRPVC insulated copper conductor, single core cable in concealed type with PVC conduit not less than 20 mm ISI marked complete all as specified and directed. |
| 99 | M&L for wiring for circuit/submain wiring alongwith earth wire with size 2x4.0 sq. mm + 1x4.0 sq. mm earth wireof FR PVC insulated copper conductor, single core cable in concealed type with PVC conduit not less than 20 mm ISI marked complete all as specified and directed. |
| 100 | S&F MCCB TPN DB,4 way vertical type,440V,3 phase with rated busbar 250 Amps, double door type suitable for MCCB as a incomer and MCBs as out going grouted in walls complete all as specified and directed. |
| 101 | S&F MCCB 100 Amps, 415 V 16 KA 4 pole with suitable size of copper extension terminals complete all as specified and directed. |
| 102 | S&F sheet metal enclosure factory made double door for DB 240 volts with 100 Amps rated bus bar SPN 8 Way IP-43 IK-09 with acrylic door complete all as specified and directed. |
| 103 | S&F MCB SP 6-32 Amps, 240V \"C\" Series 10 KA complete all as specified and directed. |
| 104 | S & FMCB DP 40 Amp 240 Volts \"B\" series 10 KA complete all as specified and directed. |
| 105 | S & FMCB FP 63 Amp 240 Volts 10 KA complete all as specified and directed. |
| 106 | M&L for earthing complete with galvanised steel plate electrode of size 600mmx600mmx6 mm thick buried directly in ground (earth pit not less than 2.25 Meter deep below from ground level with top edge of the plate not less than 1.5 Meter below from ground level connected to GI wire of size 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steelconnected to earthing test point incl excavation and earth work and disposal of surplus soil to a distance as directed incl 20 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt, 15mm thick plastering with CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia GI pipe medium grade for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part-I (2020) and connected to earth test incl testing complete all as specified and directed. |
| 107 | Supply and install testing and commissioning hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality minimum 4 star rating inverter type and EER 3.2.of capacity 2.0 TR complete with and including wall mounting bracket alongwith all connecting accessories as specified and directed.Make :- OGeneral/Hitachi /Daikin |
| 108 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volt complete all as specified and directed. |
| 109 | M&L for earthing complete with galvanised steel plate electrode of size 600mmx600mmx6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below from ground level with top edge of the plate not less than 1.5 Mtrs below from ground level connected to glavanised iron strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steelconnected to earthing test point incl excavation and earth work and disposal of surplus soil to a distance as directed incl 40 mm GI tubing light grade and necessary fitting for protection of galvanised strip incl laying of charcoal dust and common salt 15mm thick plastering with CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test incl testing complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy