}

Tender For Construction Of District Dairy Development Office Building Includes Water Supply And Sanitation And Internal Electrification At Tmss North Lakhimpur. Under Sopd-2022-23, lakhimpur-Assam

Animal Husbandry And Veterinary Department-AHAVD has published Tender For Construction Of District Dairy Development Office Building Includes Water Supply And Sanitation And Internal Electrification At Tmss North Lakhimpur. Under Sopd-2022-23. Submission Date for this Tender is 21-11-2022. Building Work Tenders in lakhimpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

34575309
Tender For Construction Of District Dairy Development Office Building Includes Water Supply And Sanitation And Internal Electrification At Tmss North Lakhimpur. Under Sopd-2022-23
Open Tender
Indian
Assam
lakhimpur
21-11-2022

Tender Details

Construction Of District Dairy Development Office Building Includes Water Supply And Sanitation And Internal Electrification At Tmss North Lakhimpur. Under Sopd-2022-23 Construction Of District Dairy Development Office Building Includes Water Supply And Sanitation And Internal Electrification At Tmss North Lakhimpur. Under Sopd-2022-23.

Key Value

Document Fees
INR 2000 /-
EMD
INR 107440.0 /-
Tender Value
INR 53.72 Lakhs /-

BOQ Items

Name of Work: Construction of District Dairy Development Office building including water supply & sanitation and internal electrification at North Lakhimpurunder SOPD-2022-23.
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 moutside the periphery of the area cleared.Junmgle clearance like cutting,felling and removing trees etc. as per directed
2Felling of tree
3Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 30 cm girth upto and including 60 cm girth
4Beyond 60 cm girth upto and including 120 cm girth
5Earth work in surface exca-vation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including gettingout and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
6Supplying chemical emulsion in sealed containers including delivery as specified. 1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
7Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti -termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the verticalsurface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration metre
8Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including With Chlorpyriphos/ Lindane E.C. 20% with 1%
9Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks
10Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.1 Mild steel and Medium Tensile steel bars
11Centering and shuttering
12Centering and shuttering including strutting, propping etc. and removal of form work. Upto plinth level
13Lintels, beams, plinth beams, girders, bressumers and cantilevers,
14Suspended floors, roofs, landings, balconies and access platform
15Laying in position ready mixedmixcement concrete
16Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland/Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works upto plinth level M 25 grade
17All works above plinth level upto floor V level5.33.2.1 Concrete of M25 grade
18Tile brick masonry with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in foundation and plinth in: 6.16.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
19Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
20Providing and laying damp-proof course 50mm thick withcement concrete 1:2:4 (1cement:2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
21Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.12.2 cement mortar 1:4 (1 cement : 4 coarse sand)
22Steel work in built up tubular (round, squareor rectangular hollow tube etc.) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
2315 mm cement plaster on the rough side of single or half brick wall of Mix: 13.2.1 1:4 (1 cement: 4 fine sand)
24Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
25Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
26Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.
27Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
28Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m²
29Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
30Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(Note:-Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood. 35mm thick.
31Providing fitting and fixing anodised aluminium slidingwindows and ventilatorsof standard sections without horizontal galzing bars joints mitred and welded and providing and fixing handles angles cleat rubber gasket roller botting device locking arran. Two track slidingwindow and vent with 6mm clear glass
32Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Grill for windows.
33Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level over first class kail wood strips 25x6 mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately):12.31.1 Flat surfaces
34Providing barge board of size 200mmx20mm with 1st class local hollock/ bonsum timber including fitting and fixing with necessary wood screws etc. complete.
35Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
36Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats.
37Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
38Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
39Alluminium fittings
40Supplying fitting and fixing anodised aluminium fittings of approved makes reasonably smooth free from sharp edges flaws and other defects and with counter shunk holes for screws including necessary aluminium screws etc complete. a) Sliding door bolt. 300x16mm
41b) Tower bolt. 300x12mm
42c) Door handle 150mm
43Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
44Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. W.C. pan with ISI marked white solid plastic seat and lid
45Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required
46Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require
47Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. Ladies
48Providing and fixing soil, waste and vent pipes :100mm dia Sand cast iron S&S pipe as per IS: 1729
49Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
50Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
51CPVC Pipe
52Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.15mm nominal outer dia pipes
5320mm nominal outer dia pipes
54Gunmetal Valve
55Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
5620 mm nominal bore
57Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
5818.16 Providing and fixing brass stop cock of approved quality :15 mm nominal bore
59Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.Bore hole = 300mm
60Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labourcharges, fittings & accessories etc. all complete, for all depths, asper direction of Engineer -in-charge.150 mm dia
61Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
62Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
63Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge.
64PVC high pressure pipes
65Supplying fitting and fixing supreme/ prince brand or other similer ISI approved PVC high pressure pipes of following sizes with all necessary approved PVC fitting such as bend, tee, etc completeat al levels including below GL as directed and specified 32mm
6625mm dia
6715mm
68Supplying fitting and fixing Gun metal check valve including necessary thread to pipes. 40mm
69Supplying, fitting and placing in position plastic cylindrical vertical closed top PCVC tank of Polycon make. (111 )2000 litre capacity
70Labour for erecting and placing plastic PCVC tank over the staging up to a height 5.00m complete as directed. 2000 Ltr Cap
71Single phase submersible motor pump set (Texmo/ Crompton/ Aquatic) suitable for 100mm dia bore well and above .1.5 HP STAGE 5 to 26 with control panel
72Electrical wiring
73Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
74Group B
75Group C
76Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earth-ing as required.
77Wiring for circuit/ submain wiring
78Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
792 X 2.5 sq. mm + 1 X21.5 sq. mm earth wire
802 X 4 sq. mm + 2 X 4 sq. mm earth wire
81Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
82Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
83Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
84Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 A TP&N
85Providing and fixing following rating and breaking capacity and pole MCCB with thermo-magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
86Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
87Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
88Supplying including fitting and fixing of following A.C. exhaust fan in the existing hole on the wall of following with making necessary connection as approved by the Deptt. as required complete . Power flow 225mm sweep
89Supplyingincluding installation, commissioning of vermin and dust proof totally enclosed phosph-atasied powder painted cubical ouit door floor mounting compart-mentalize panel board size 0.8Mx 0.8Mx0.4M made of 16SWG ..as specified and directedby the deptt. confirming to IP 65 potection comprising of the following electrical items:- 1. 40mmx5mm copper Bar 0.20M length 2. Digitel 3 Phase Voltmeter Accuracy class0.5-1No. 3. Digitel 3 Phase Ameter Accuracy class0.5-1No. 4.Pilot lamp with integral ckt LED 110-230V (Red, Yellow and Blue) 2 Nos 5. Voltmeter and Ameter selector switch 2 nos 2 A slide fuse unit -6 Nos.
90Supplying with installation ,testing and commissioning of Hi-wall 5star rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and out door unit copper pipe and electrical connection as approved by the Department upto 5 meter between the room unit and out door unit as directed by the Deptt. ECBC7.4 : 2 Ton capacity
91Executive/Chairman table Model MAESTRO MAIN DESK+ERU+JOINING TABLE+ MOBILE PEDESTAL+BACK UNIT(Specification as per Annexure C - C2.)
92Executive revolving high back chair hydraulic pushback type with best quality soft P.U.handle seat & back with heavy duty P.U. foam covered with best quality cloth comfort & stlyish.
93Godrej Table.Model 2ARC (Specification as per Annexure B - B2.)
94Revolving Mid back chair hydraulic pushback type with best quality soft P.U.handle seat & back with heavy duty P.U. foam covered with best quality cloth comfort & stlyish.
95Four shelves steel Almirah with five compartments with three way inside locking system having rigid unpickble six liver lock with stainless steel key. Enamel spray painted and anti rust treated nicely finished made of 0.8mm CR sheet. Size –(1980x915x480)mm.
96Steel tubular cushioned chair made of 25mm heavy MS pipe frame seat and back made of high density foam of block board with 1st class leatherite cloth with wooden arm rest
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail