Military Engineer Services-MES has published Tender For Certain Repari Maint To Em Installation Of Repairs To Central Ac Plant Split Acs Certain Ref And Ac Items At 167 Mh Under Ge South Pathankot. Submission Date for this Tender is 25-11-2022. HVAC Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

34548069
Corrigendum : Tender For Certain Repari Maint To Em Installation Of Repairs To Central Ac Plant Split Acs Certain Ref And Ac Items At 167 Mh Under Ge South Pathankot
Open Tender
Indian
Punjab
pathankot
25-11-2022

Tender Details

Certain Repair Maintenance To Em Installation Of Repairs To Central Ac Plant Split Acs Certain Ref And Ac Items At 167 Mh Under Ge South Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Nov-2022 BOQ REVISED BOQ 18-11-2022
2 18-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: CERTAIN REPARI/ MAINT TO E/M INSTALLATION OF REPAIRS TO CENTRAL AC PLANT, SPLIT ACS, CERTAIN REF AND AC ITEMS AT 167 MH UNDER GE(SOUTH) PATHANKOT.
Sl. No. Item Description
1M&L for taking down the defective split/Window unit of 1.5 TR Capacity, shifting to work shop, taking out the defective unserviceable hermetically sealed compressor from the unit, replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumissing, charging of Refrigerant gas, testing at work shop.Shifting to the location reinstalling the same in its Original position connecting up all etestion electrical, connection and Testing & Commissioning. All as specified as directed.
2All as per Item No 1 above but for 2 TR CapacityNote : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
3M&L for taking down the damage condenser fan blade of 1.5TR split/Window type AC’s of any make and supply & fixing suitable new fan blade and testing & commissioning the unit.
4All as per Item No 3 above but for 2 TR Split AC
5M&L for taking down the damaged blower unit of any make split/ Window AC and supply and fixing of new blower unit of suitable type and testing & commissioning the unit.
6M&L for complete scraping out the crusting painting of the complete body of out door unit metallic surface, cleaning the surface thoroughly, apply putty / metal paste, prepare the surface, apply 2 coat of synthetic enamel paint over a coat of red oxide primer for 1.5 / 2TR capacity split type AC’s.
7M&L for 1.5 TR Capacity cleaning flushing the refrigeration system thoroughly with CTC, and Nitrogen gas, leak testing and locating the leaks, rectifying the leaks, by brazing the joints, replacing the damaged copper pipes, silver rod/ copper.Pressure testing, dehydrating, vaccumissing, gas charging testing & commissioning the system the work includes required strainer, N2 gas, Refrigeration gas and transportions Handling the unit. All as specified as directed by Engineer-in-Charge.
8All as per Srl Item No 7 above but for 2 TR Capacity
9M&L for taking down the unserviceable temperature sensor probes and supply & fixing new sensor probe suitable for any type, make split/Window type AC’s and testing & commissioning.
10M&L for taking down the defective unserviceable printed circuit Board and S/F of new printed circuit board for any make split/window type AC unit.
11M&L for taking down the defective unserviceable sealed fan motor & S&F new fan motor ofthe same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site
12M&L for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity.
13M&L for taking down the defective unserviceable starting/running capacitors 80/100 MFD 230V / 50Hz and supply and Fixing the new starting capacitor of the same capacity to split / window type AC’s and testing.
14M&L for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing.
15M&L for taking down the defective unserviceable Thermostatic switch and S/F new thermostatic suitable for window type AC’s and Testing.
16M&L for taking down the damaged drain pipe and S/F of new insulated drain pipe suitable for split type AC’s.
17Material and Labour for taking down the defective capillary tube set and supply & Fixing new suitable capillary set for split type AC’s.
18M&L for taking down the rusted out door unit stand and supply & fixing the stand with required anchor fastner and nut & bolts and rubber bushes for 1.5 / 2 TR Split unit.
19M&L for taking down the burned out door unit fan motor and rewinding, overhauling renewal of worn out shaft & bushes, and fixing to the unit, of 1.5 / 2 TR Split units.
20M&L for taking down the defective remote control unit and S/F of new remote control unit for split/window type AC of 1.5 / 2 TR of any make and testing.
21M&L for taking down the defective definite purpose magnetic contactor of the split/window AC’s of any make, and supply & fixing of new contactor of 240 VAC.30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing.
22M&L for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 1.5/2 TR capacity and S/F new fan motor suitable for Split type AC’s.
23M&L for taking down the defective starting capacitor of split / window type AC’s and supply & fixing the new starting capacitor of 80/100 MFD 230V, 275SV-50Hz and Testing for 1.5/2TR AC Unit.
24M&L for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2TR split and window type Ac unit.
25M&L for taking down by disconnecting water connections and shifting elective for 40/60/80 Ltrs. capacity water cooler to work shop, taking down the defective sealed compressor and replacing with new compressor, the work includes flushing the complete system condenser, cooling coil with Nitrogen, removal all carbon, oil & dirt, brazing & inter connecting the refrigeration lines, de-hydrating, purging with refrigerant, vaccumissing and charging of R22 / 134a Refrigerant and testing & commissioning and shifting to original location and connecting up the electrical & water connection.All as specified as directed.
26All as per Srl Item No 25 above but for 120/150 Ltrs. capacity water cooler
27M&L for complete tinkering the corroded sheet metal parts, side panel, door, with existing gauge M.S. Sheet and renewal of the bottom base plate, mounting lets, fan motor base plate, and condenser should cover etc., with existing size gauge G.I. sheet, with required Angle Iron, Nut & Bolts all as per the existing size and shape including cutting, bending, welding and completing fixing all other components, complete scraping with old paint, prepare the surface, painting 2 coat of enamel paint over a coat of primer and complete cleaning the water tank and shifting to the location and testing any capacity of water coolers, Complete All as specified as directed.
28M&L for charging the water cooler of 40/60/80 Ltrs. capacity including taking down, transporting to workshop flushing out the cooling coil, condenser, brazing the refrigerant lines, replacing of liquid line copper strainer, leak testing, purging with refrigerant, vaccumissing and charging of R22/R 134a gas, testing & commissioning and shifting to the location and connecting up the electrical & water connection.All as specified as directed.
29All as per Srl Item No 28 above but for 120/150 Ltrs. capacity water cooler
30M&L for painting the water cooler including scraping out the old paint prepare the surface, painting 2 coat of enamel paint over a coat of primer, the work including necessary putty, metal paste etc., and disconnecting from the position and refixing after painting for any capacity of the water coolers.
31M&L for to the water cooler tank and cooling coil by dismantling the water cooler and carried out the lead soldering to cooling coil to the tank outer surface where ever the detached portion and rectify the leaks portion and re-assembly the water cooler of any capacity.
32M&L for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers.
33M&L for taking down the defective starting relay and S/F of new starting relay for any capacity water cooler.
34M&L for taking down the defective overload relay and S/F of new over load relay suitable for any capacity water cooler.
35M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler.
36M&L for taking down the defective starting capacitor and Supply & Fixing new starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs. Capacity.
37M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor of 25/36 MFD, 440 VAC, 50/60 Hz suitable for 150 Ltrs. Capacity water cooler.
38M&L for taking down the defective thermostatic switch and Supply and Fixing of new thermostatic switch for water coolers.
39S&F of Left/Punch cook for water cooler of any capacity.
40S&F float valve for water cooler of any capacity
41M&L for taking down the damaged drain connections and drain pipe and S/F of new drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler.
42M&L for taking down the defective unserviceable sealed fan motor and S/F new fan motor with suitable capacitor for water cooler upto 40/80, 60/120 ltrs. Capacity.
43M&L for taking down the damaged condenser fan blade and supply and fixing of new fan blade suitable for 40/60/80 water coolers.
44M&L for taking down the corroded air cooler condenser and supply and fixing of new air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80 Ltrs. Capacity.
45M&L for taking down the complete corroded sheet metal body of out door unit of split unit and supply and fixing of new out door unit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
46M&L for taking down the complete corroded sheet metal body of indoor unit of split unit and supply and fixing of new indoorunit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
47M&L for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 1.5 TR Split Ac
48M&L for taking down complete old corroded, unserviceable window AC of 1.5 Ton capacity and depositing to MES Store and supply and fixing a new window AC of 1.5 Cpacity
49M&L sub-main wiring with 4.0 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt grade single core cable drawn through and including rigid PVC conduit medium grade minimum 20mm size and its accessories complete along with 4.0 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface,in walls/ ceiling/ roofs all as directed and specified including dismantling old one Note : Three runs of PVC copper cable and one run of PVC conduit will be measured as one Rm.
50M&L for complete carryout the servicing to Split/Window type AC’s/water cooler/deep freezer/ including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carryout the chemical cleaning to chocked cooling coil & condenser coil, by spray the dilated chemical cleaning agent, till remove complete chocking, flushing across the coils, cleaning all the sheet metal parts, filter, grill and fixing all the dismantled parts with sheet metal screws, lubricating the fan motor bush / bearing, checking all the electrical connections, renew any burned legs / clip and fixing back to position and testing.(Note: Gas Charging if required will be measured and paid seperately).
51Supply and charging refrigerant R-22 complete one time for topping up or making full qty including plugging the leakage complete and as directed.
52Supply and charging the refrigerator gas R-134A / R-34A /R-407/any environmental friendly refrigerant gascomplete all as specified and as directed.
53Supply and charging compressor oil suitable for AC"s, water cooler ,Refrigerator and deep freezer complete including testing etc, complete all as specified and as directed.
54Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray paintingcomplete all as specified and directed.
55S&F in replacementRefrigirator of capacity 310 Ltrs complete
56S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 165 to 185 Ltrs including Gas charging.
57S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 285 to 320 Ltrs including Gas charging.
58S&F in replacement of existing UNSV cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity.
59Supply, install, testing and commissioning of voltage stabilizer copper wound of capacity 4 KVA, automatic operation, single phase naturally air cooled indoor type, wall mounted triple boost type & designed for input variation between 170 volt to 270 volt AC with output voltage stabilised at 230 volt AC 50 Hz with accuracy +/- 2.5% and with inbuilt digital display for showing Voltage/ Amps of incoming and outgoing with selector switch with TDR of 2 to 3 minutes and high and low voltage cutoff complete all as specified and as directed.
60M&L for Diconnecting unsv deep freezer of any size and depositing to MES Store Yard and Supply, installation, commis-sioning of ne Metal Top Deep Freezer singlephase 240 volt, 50 Hzof capacity 300/320 Ltrs.
61M&L for Diconnecting unsv water cooler of any size and depositing to MES Store Yard and Supply, installation, commis-sioning of Water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity 60/120 Ltr
62PCC (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for mass concretes or in any indicated positions etc complete all as specified
63PCC (1:3:6) type C-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay complete all as specified
64PCC (1:2:4) type B-2 (Using 20 mm graded stone aggregate) for foundation coping complete all as specified
65M&L for replacement of existing UNSV schematic diagram with LED laminated display with openable transparent glass covered of main incoming and outgoing elect supply/water supplyto various destination and generator supply destination all as directed and specified size of display not less than 1.5x3.0 mtr with all decoration as specified.
66M&L for replacement of acrylic sheet diagram of main incoming and outgoing elect supply/water supplyto various destination and generator supply destination all as directed and specified size of display not less than 1.0x2.0 mtr with all decoration as specified.
67M&L for replacement ofacrylic sheet DO and DON"T instructions in Hindi/Punjabi and English launguage for elect supply installations and water supply installatllations all as specifiedsize of display not less than 2.0x1.0 ft with all decoration as specified.
68M&L for replacement ofacrylic sheet instructions for pump operation in Hindi/ Punjabiall as specifiedsize of display not less than 2.0x1.0 ft with all decoration as specified.
69M&L for fire point comprising of the following. (a) CO2 fire extinguisher 4.5 Kg (02 Nos), b) Dry carbon powder (ABC)-05 Kg (02 Nos) ,ceiling Hook,fire beater,sand buckets 9 mtrs capacity-02 Nos ,Showel complete with angle iron stand duly painted with two coats of synthetic enamel paint of approval colour over a coat of red oxide primer incl dismentling old unsv one.
70M&L for replacement ofelectric shock and its management with picture in Hindi/Punjabiall as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
71M&L for replacement ofMaintenance schedule of Sub stations instructions board on acrylic sheet in Hindi/Punjabiall as specifiedsize of display not less than 3.0x1.5 ft with all decoration as specified.
72M&L for replacement ofYearly periodical maint f HT Circuit Breakers on acrylic sheet in Hindi/Punjabiall as specifiedsize of display not less than 3.0x1.5 ft with all decoration as specified.
73M&L for replacement ofDO"s & DON’T"s for HT circuit breakers on acrylic sheet in Hindi/Punjabiall as specifiedsize of display not less than 3.0x1.5 ft with all decoration as specified.
74M&L for laying stone graded coarse aggregate of size 40 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by engr-in charge.
75M&L for laying stone graded coarse aggregate of size 20 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed.
76S&Fin replacement existing UNSV tube light fitting with LED 20W inverter batten type fitting 4 feet long aluminium extruded housing,IP-20 ,rated voltage 230 V, 50 hz, charing time 10-12 hours and backup time 04 hours system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewiredand connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
77S&F bldg security light fittings with LED security light fittings 60 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 mtr long of 25 mm dia and fixing with bldg for fixing of street light fitting all as directed. Note: (i) Driver Efficacy – more than 85% ( constrant current driver).(ii)Driver Type – Potted (iii) THD- < 10% (iv)Led Driver Current – less than 750 mA(v) Efficacy of Led Fixtrue –100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 5KV (vii) Working Humidity -10% to 90% RH (ix) Led Make – Nichia/Philips Lumiled/ Cree /Osram/ Seoul (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Castwith company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from Third Party ( instead of company in house lab) NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut boltsand GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
78M&L for insulation mat 3.3 KV ISI suitable LT panelcomplete all as specified and as directed.
79Supply, installing, testing and commissioning of LT feeder pillar box factory madecubicle indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron base frame made of 40 x 40 x 6mm , 45 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-66 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs groutedin PCC complete including paintingwith two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect for Bay work station and includingprovn of the following:-Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately. i)Aluminium Bus bar 400 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos)with PVC sleeve insulationii) MCCB 4 pole 415 V 3 phase 250 Amp, 36 KA (Thermal magnetic release) Ics=100%Icu, All MCCB"s should have Company Made Spreaders Links.- 01 Nos (incoming)iii) MCCB 3 pole 415 V 3 phase 160 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu, All MCCB"s should have Company Made Spreaders Links.- 02 Nos (outgoing)iv) MCCB 3 pole 415 V 3 phase 100 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu, All MCCB"s should have Company Made Spreaders Links. - 02 Nos (outgoing) v) Digital Voltmeter of size 96x96mm 0-500 volts with selector switch - 01 Nos
80S&F in repairs ofMCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as directed .
81320-400 Amps, 3P, Adjustable type,415V MCCB, 35KA rating , All MCCB"s should have Company Made Spreaders Links.
82200-250 Amps, 3P,Adjustable type, 415 V MCCB, 25KA rating All MCCB"s should have Company Made Spreaders Links.
83160-200Amps, 3P,Adjustable type, 415 V MCCB, 25KA rating, All MCCB"s should have Company Made Spreaders Links.
84125-160Amps, 3P,Adjustable type, 415 V MCCB, 25KA rating, All MCCB"s should have Company Made Spreaders Links.
8532 to 80 Amps, 3P, 415 V MCCB, 16KA rating, All MCCB"s should have Company Made Spreaders Links.
864 Pole MCCB, 415 V, Adjustable type with breaking capacity 35 KA, 320-400 A rated,All MCCB"s should have Company Made Spreaders Links.
874 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200-250 A rated, All MCCB"s should have Company Made Spreaders Links.
884 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160-200 A rated, All MCCB"s should have Company Made Spreaders Links.
894 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 125A to 160 A rated, All MCCB"s should have Company Made Spreaders Links.
90S&F for replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
91Dismentling old feeder pillar &Supply, installing, testing and commissioning of LT feeder pillar box factory madecubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheetfloor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs groutedin PCC complete including paintingwith two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (b) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
92Dismantling, repairing & refixing of the following damaged/ burnt components with new components of 48 V DC 75 Amps SMPS power plant including testing complete all as specified and directed.(a) SMPS controller with its daughter cards -01 Sets (b) 48 V SMPS modules -03 Nos (c) Control supply -01 Each (d) Surge protection cartridges-04 Each
93Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.