Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-11-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-11-2022 |
| 2 | 03-11-2022 | Amendment | Other | 16-11-2022 |
| Sl. No. | Item Description |
| 1 | AIR CONDITIONER WINDOW TYPE1.5/2 TONM&L Removing the burnt/defective sealed compressor unit of any make from Windowtype of air conditioner capacity 1.5 Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Tecumseh Kirloskar, Model RNB 5521of rotary compressorby tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site. |
| 2 | All as per item No 1 here-in-before above but Air conditioner of 2 ton capacity and sealed compressor unit Make -Tecumseh Kirloskar, Model RNB 5529 complete all as directed at site. |
| 3 | Testing and Repairing leakage in systemAir conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete. |
| 4 | All as per item No03here-in-before above but Air conditioner of 2 ton capacitycomplete all as specified and direct ed at site. gas F-22 (approx 2.30 Kg) complete. |
| 5 | S&F in replacement of electric blower motor capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site. |
| 6 | S&F in replacement of electric blower motor capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and directed at site. |
| 7 | Supply & fixing in replacement thermostat for window type AC, working on SP, 230V,AC Make : Indfos/ Ranutrol, complete all as directed at site. |
| 8 | Supply & fixing inreplacement of PCB circuit with remote control for air conditionerof any Make and capacity complete all as specified and direct ed at site.Make : Voltas/Carrier/Ranutrol/LG/Blue star |
| 9 | Supply & fixing in replacement air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and direct ed at site. Make : Marcon |
| 10 | Supply & fixing in replacement starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and direct ed at site.Make : Asian/Empire |
| 11 | Supply & fixing in replacement running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and direct ed at site. Make : Asian /Empire |
| 12 | Supply & fixing in replacement capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and directed at site. Make : Asian /Empire |
| 13 | Supply & fixing in replacement relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas |
| 14 | Supply and fixing of copper filter pencil type to any make and capacity of air conditionercomplete Make : VaishaliMetal complete all as specified and directed. |
| 15 | S&F in repair front grill of PVC for window type AC of any make complete all as specified and directed at site. all as per existing grill |
| 16 | Supply & fixing in replacement of selector switch for window type AC complete all as specified and directed at site. Make- Blue star/Voltas |
| 17 | Supply and fixing relay over load protector complete set suitable for AC complete all as specified and directed at site. |
| 18 | Supply & fixing in replacement relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas |
| 19 | Supply & fixing in replacement cable PVC flexible copper conductor 3 core heavy duty 4.0 Sqmm complete all as specified and direct ed at site. Make : Plaza/Finolex/ ISI mark |
| 20 | Supply and charging of gas Freon - 22 in AC plant of any capacity Note:-Gas will be accepted in sealed and tested cylender having weight of gas 13.6 Kg in each cylender. |
| 21 | S&F in repairs Sheet metal inclosure with earth plug andsocket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make:- HAVELL\"sor equivalent in Legrand/Standard. |
| 22 | S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete. |
| 23 | S&F in repairs Metal clad socket, 2 pole with earth terminal capacity 20 Amp, fixed in existing single pole and neutral enclosure complete. |
| 24 | S&F in repairs MCB SP, 240 volts, 5-32 Amps, 10KA breaking capacity, \"C\" type including connection with suitable size almuminium /copper lugs complete all as directed |
| 25 | M&L Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete. |
| 26 | DESERT COOLERS Supply & fixing in replacement fan motor assembly of 1/7HP, 230V SP, AC complete clamps=04 Nos and water fan 18\" sweep Make GE Motors/Auc/Crompton/ISI Mark complete all as specified and directed at site. |
| 27 | Supply & fixing in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC Make : Crompton/cool- Home/GE Motors/ISI Marked complete all as specified and directed at site. |
| 28 | Supply & fixing inreplacement wood-wool pad complete heavy size (set of three pads) Approx wt400 Gms complete all as specified and directed at site. |
| 29 | Supply & fixing in replacement capacitor 6 MFD, 440V, Make - Empire/ EPCOS/ Capro/ Asian or ISI Mark complete all as specified and directed at site. |
| 30 | M&L Scrapping down the complete existing paint inside and out side of desert cooler cleaning the surface and applying two coat of synthetic enamel paint over and including one coat of red oxide primer with sprayer and writing SM/MES No with white black enamel paint complete all as specified and directed at site. |
| 31 | WATER COOLERS Supply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5\" dia complete etc Make : GE Motor/AUE complete all as specified and directed |
| 32 | All as per item No-31 but 1/20 HP 1350 RPM with fan of 13\" diacomplete all as specified and directed. |
| 33 | All as per item No-31 but 1/35 HP,1350 RPM withfan of 10\" dia complete all as specified and directed. |
| 34 | All as per item -31 above but 1/83 HP 1350 RPM and fan of 9\" dia complete all as specified and directed. |
| 35 | Supply & fixing in replacement starting capacitor 40 to 60 MFD, 275 volts Make- Sharda/Empire/Bhel etc complete all as specified and directed. |
| 36 | All as per item No-35 above but of 60 to 80 MFD complete all as specified and directed. |
| 37 | Supply & fixing in repairs running capacitor 10 MFD 440 volts AC Make: EPCOS/ Capro /Asian etc complete all as specified and directed. |
| 38 | All as per item No 37 but of 15 MFD complete all as specified and directed. |
| 39 | All as per item No 37 but of25/30 MFD complete all as specified and directed. |
| 40 | Supply & fixing in replacement thermostat for water cooler up to 150 ltr capacity. Make : Ranutrol/Danfoss/Indfos etc complete all as specified and directed. |
| 41 | Supply & fixing inreplacement push cock heavy duty brass Chromium plated 15mm bore (to match with existing defective push cock) Make King or Equivalent ISI marked as approved by GE. complete all as specified and directed. |
| 42 | Supply and fixing of float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or Equivalent as approved by GE. complete all as specified and directed. |
| 43 | M&L Scrapping downthe existing paint of water cooler of any make& capacity cleaning and preparing the surface with necessary putty work and painting the complete body of Water cooler with foundation frame of compressor, condenser etc with one coat of synthetic enamel paint over and including a coat of red oxide primer withspray painting and writing SM/MES No with white/black paint all as directed. |
| 44 | Supply and fixing starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind |
| 45 | Supply and fixing in repairs of over load protector for compressor of water cooler complete all as specified and directed. |
| 46 | Supply and fixing of copper filter pencil type to any make and capacity of water cooler etc complete Make : VaishaliMetal complete all as specified and directed. |
| 47 | Supply and fixing in replacement of capillary tubing having 0.050/0.055 bore complete Make : Vaishali Metal complete all as specified and directed. |
| 48 | Supply & fixing inreplacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5Mtr long complete all as specified and directed at site. |
| 49 | M&L Removing the burnt/defective sealed compressor unit of any make from water cooler cap 60 ltr/hrBy cutting of suction and discharge lines and un-screwing the foundation nuts supply and fixing of new sealed compressorunit make : Kirloskar/Emmersonmodel : AE 444M or KCE 444 HAA/CAJ34 etc by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete. |
| 50 | All as per item No 49 above but water cooler capacity 80 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model : CAJ 2612M/AE451E/KCE 461etc complete. |
| 51 | All as per item No 49 but water cooler capacity 150-150 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model AHR-13/KCJ 513 complete all as specified and directed at site. |
| 52 | Supply & fixing in replacement cable PVC 3 core flexible heavy duty copper 2.5 Sqmm complete Make : Plaza/Finolex or ISI Mark complete all as specified and directed. |
| 53 | Repairing Testing the leakage in system by charging of Nitrogen Gas up to 300 PSI.Repairing of leakagespots/Joints with gas welding work, cleaning and flushing the completewater cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler 40/60/120 ltr capacity. |
| 54 | M&L Dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc. |
| 55 | M&L Replacement of water cooler inner tank made of stainless steel as per existing capacity (80 Ltrs) & size with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and directed at site. |
| 56 | All as per item No 55 but 150 but, Ltrs. complete all as specified and directed at site. |
| 57 | M&L Replacement of glass wool in 40/60/80/120 ltrs capacity water coolers by taking out inner outer tank and reassembling in same position including testing complete all as specified and directed at site. |
| 58 | Repairing of bottom base and legs of water cooler by suitable welding work complete all as specified and directed. |
| 59 | DEEP FREEZERM&L Testing the leakage in system by charging Nitrogen Gas up to 300 PSI.Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing complete. |
| 60 | Supply & fixing inreplacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 complete all as specified and directed at site. |
| 61 | Supply & fixing inreplacement of thermostat Auto defrost type complete for Deep freezer (Refrigeration of)any make & capacity Make : Ranutrol/Indfos etc complete all as specified and directed at site. |
| 62 | M&L Removing burnt/defective sealed compressorunit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts.Supply and replacing of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415incl necessary gas welding making the system leak proof, testing andtightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete. |
| 63 | All as per item No 62 but compressor Make-Tecumseh Model TSK-1350 complete all as specified and directed at site. |
| 64 | Supply and fixing relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and directed at site. |
| 65 | Supply & fixing in replacement of drier filter complete set suitable for deep freezer 215 / 386 ltrs complete all as specified and directed at site. |
| 66 | Supply, fixing & testing of blower motor for Deep frizerSP 230V20 watts complete with fancomplete all as specified and directed. |
| 67 | REFRIGERATOR S&F Relay current type and overload protector complete suitable for compressor model KCE 336, KCE 345 fixed in repairs complete all as specified and direct ed at site.MAKE : Ranutrol/ Voltas /LG. |
| 68 | S&F Thermostat auto defrost type, fixed in repairs for refrigerators any make & capacity 165/310 Ltr Rerfrigerator complete all as specified and directed at site. MAKE : Danfos/Ind foss/Ranutrol. |
| 69 | Vegitable tray as per sample and suitable for refrigerator MakeGodrej, Voltas or whirlpool , LG of capacity 300 Ltr. |
| 70 | S&F Evaporator suitable for Voltas/Godrej refrigerators capacityfixed in repairs 286/300 ltr complete all as specified and directed at site . |
| 71 | M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity(165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG,including necessary gas welding, making the system leak proof, including Repair to leakage in system by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and testing, the system for smooth functioning complete and charging of refrigerent gas 134a complete all as specified and directed at site. |
| 72 | Supply and charging of gas Freon- 134-A complete all as specified and directed.Note:- Gas will be accepted in sealed and tested cylinder having capacity 10 Kg each. |
| 73 | Taking down old/burnt cable of any size and Supply and fixingAerial bunched cable (AB) LT of size 3 core- x70sqmm+1-core x 50 sqmmwith three power cores stranded compacted circular aluminium conductor screened with black extruded semiconducting compound, natural coloured XLPE insulated core screenedwith black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC( core identification by colour tape marking red, yellow and blue with colour tape placed longitudinally under the copper tape) and one bare messenger wire shall be stranded non compacted circular aluminium alloy conductor .all as specified and directed. Make KEI, Gloster,PolycabNote:- The following hardware fittings and accessories shall be used to install,erect and join the AB cable(i) Suspension clamp with eye hook(ii) Suspension fittings and corresponding eye hook(iii) Dead eye fittinngs(iv) Nylon Tie(v) connectors |
| 74 | Taking down or out existing cable of sizes 2/3.5/4 core 10 sqmm to 70 sqmmfrom the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub stationincluding segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and removing unserviceable cable for further disposal complete all as specified and as directed. |
| 75 | Laying only serviceable cable obtained from item No 02 above in same or new location of size 2/3.5/4 core 10 to 70 sqmm in trenches / ducts/ along walls / poles /under roads etc. including necessarycable lugs, gland etc complete all as specified and as directed. Note:- Earth work , Bricks , sand Lugs and glands will be measured and paid seperately under respective items. |
| 76 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 6 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Finolex/ Gloster/ Polycab |
| 77 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 78 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 79 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 80 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 81 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 82 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 83 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 84 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 70 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 85 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 86 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 120 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 87 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 185 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.Make:- Havells, KEI, Gloster, Polycab. |
| 88 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 400 Sqmm UG Cable including complete connection and crimping. Make:- Havells, KEI, Gloster, Polycab. |
| 89 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 300 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 90 | Replacement of alluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 240 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 91 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 185 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 92 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 150 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 93 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 120 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 94 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 95 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 95 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 50 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 96 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 35 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 97 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 25 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 98 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 16 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 99 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 10 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 100 | Cutting/trimming/Choppingof tree branches along the over head lines of LTupto 5 mtr from elect line on both sides of the span and disposing off the cut trees/branches to a distance of n.exc 50m and clearing the site as directed by Engr-in-Charge. |
| 101 | Scraping of old paint from two pole structure without removing accessories and preparationof surfaces for repainting.M&L for painting the poles with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamel paint also painting the remaining Iron parts i.e. cross arms, supporting angles, XPM jali, clamps, GI bkt etc and steel pole above 1.5 mtr height by applying one coat of alumn paintor PCC pole with snowcem of approved color all as required at site and as directed. |
| 102 | Restringing of over head line ACSR of any size and upto 5 wires in a span with GI earth wire of 4 mm dia of span length 30 to 60 m to permissiable sag inclPVC line spacer ,winding with Aluminium conductor and triming of branches of tree beside the span all as directed. Note Cost forLine spacer in between span shall be included in quoted rates |
| 103 | M&L for fixing in replacement ofACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre to centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers, etc complete all as specified and directed by Engr-in-Charge. |
| 104 | Taking down unsv PCC poles and M&L for steel tubular swaged pole type 410 SP-31 (9 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping, complete all as specified and directed. Make : Quality steel, Surjit steel industries, Sohan Lal & Sons, Anil Engg Corporation, Zain Industries Srinagar, Advance Tube Jammu, Jindal Steel Products. |
| 105 | Excavation in tranches not exceeding1.5 m wideand not exceeding 1.5 m deep for foundationof laying cable including gettingout in soft/loosesoil complete all as specified and directed. |
| 106 | Returning filling in including spreadingwateringand well ramming in layers not exc25cmcomplete all as specifed. |
| 107 | Removing surplus soilto distance not exceeding50 m and depositing where directed at a level notexceeding 1.5 m above the starting pointcomplete all asspecifiedand directed. |
| 108 | M & L for protection to cable with one layer of brick laid flat across the cable using all size sub class \"B\" Bricks. |
| 109 | Sand cushioning to under ground electric cables including watering and consolidation all as per clause 19.75 of SSR Part-I |
| 110 | M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified. |
| 111 | M&L PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in pole copingcomplete all as specified and directed including necessary from work. |
| 112 | Supply and fixing in replacement of shackle type insulators, porcelain, vitreous, brown or green insulator including galvanised mild steel straps, washers, insulators, bolts, washers and nuts, working pressure 1100 votls and size of 100 in height and 115 mm dia complete all as specified and directed by Engr-in-Charge. |
| 113 | Suplying and fixing in replacement of Pin type, porcelin, vitreour, white, brown or green insulator, size 100 mm height, 65 mm dia for 1100 volts grade,conforming to IS: 7321-1931, complete all as specified and as directed by Engr-in-Charge. |
| 114 | S&F PVC Spacer 2/4 way for LT over head line 1100 V complete all as specified and directed by Engr-in-Charge. |
| 115 | Supply and fixing in replacement of HT feeder pillar boxoutdoor type factory made weather and vermin proof made out from 3.15 mm sheet supported with legs all across the panel made of angle iron 50x50x5 mm of size 1.2 mtrx1 mtrx1 mtr with 3 Nos required lengthAluminium bus bar of size 40x10mm or 400 Amps for11 KV , 11 KV post Insulator 6 Nos duly drilled hole for HT Cable connection including front and rear side openable with locking arrangment suitable for 11 KV HT and provision for incoming and out going HT cable connection including painting with two coats of smoke grey synthetic enamels paint over a coat of red oxide primer complete and providing security fence XPM jally type of 2 mtr height from ground level square type all rounded 2.5 mtr length with 9nos angle iron of 25x25x5mm of hight 2.25mtr (2mtr above ground 0.25 mtr under ground) including necessary location gate of same XPM jally all as specified and directed . Note:- Feeder piller box shall be mounted on brick platform built in PCC not less then 60 cm above ground level with suitable PCC foundation rendering 15 mm in CM (1:6), applying two coats and cement base paints and XPM jally supported on 9 nos angle iron with concrete base. Make : DVEPL Electricfield or equivalent. |
| 116 | Taking out of deffective / burnt stablizer from verious locations ofverious capacity from 1 KVA to 5 KVA single phase and repair /replacement of the following defective parts as under and testing complete all as specified and directed. by Engr-in-charge.(a) Terminal Strip |
| 117 | (b) Push button switch |
| 118 | (c) Rocker switch |
| 119 | (d) Circuit card from 3 to 5 KVA |
| 120 | (e) Circuit card from 1 to 2 KVA |
| 121 | (f) Relay 24 Volts 250 Ohms for 3 to 5 KVA |
| 122 | (g) Volt meter 0-300 volts size as per sample |
| 123 | (h) Indicator lamp (red/green) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail