Supply Of Health Kit And Medical Equipments To Each 154 Grama Panchayaths In Kolar District , Bmi Chart & Itys Application Details Bmi Chart-1 Sun Board, Reecho Solvent Venial With Black Lamination , Mounted On Sun Board, Design & Digital Printing, Height3 X 2 Width, 5Mm, Blade Length:1.5Mts, Item Dimension:6X4x2cms ( Lxwxh ) Measurement Range: Upto 26.5Cm. Graduation: 1Mm. Color Coded: Red ( Sever ) 0-11.5Cm; Yellow ( Moderate ) 11.5-12.5Cm; Green ( Normal ) 13.5-26.5Cm, Digital Weighing Scale Measures Body Weight ≫Or Upto 150Kgs, Dimensions:27 X 2.2 X 29Cm, Weight:1.26Kg, Power:Ac Adapter Input, Display:Liquid Crystal Display With Backlight, Operating Temparature Range:100 C To 350C, Operating Temparfature Range:50C-400C / Relative Humidity Less Than 85%, Digital Bp Apparaturs Should Contain One Machine Operation Method: Auto Inflation, Auto- Measurement Display: Digital Display With Back Light Pressure Detection Range: 0.0Kpa-37.3Kpa ( 0Mmhg-280Mmhg ) Pulse Rate Detection: 40Beats / Min-199 Beats / Min Cuff Applicable Arm Circumference: 22Cm-42Cm Working Temperature: +50C To 40 C Working Humidity: 15% Rh-80% Rh Working Atmospheric Pressure: 86Kpa-106Kpa Transportation And Storage Temp & Humidity: 20 C- +55 C / 15% Rh-93% Rh Transportation And Storage Atmospheric Pressure: 86Kpa-106Kpa Adaptor Power: Usb 5V / 500Ma Or 4 Section Dry Cells Others: Speech Report, Irregular Hear Beat Detection With Change In Screen Color, 2Yrs, Warrantee, Dual User Profile, Glucometer Meter Testing Meters For Blood Glucose Assay Method ( Amperometry ) Weight ( 33-37 Gm ) Including Batteries Double Batteries ( Two Cr 2032 Lithium Batteries For Battery Life Up To 3000 Test And Memory Up To 1000 Test Blood Glucose Assay Range 20-500Mg / Dl Operating Relative Humidity ( 10%-90% ) ( Noncondensing ) Operating Temperature ( 10 To 50 Degree Celsius ) Storage Temperature ( -20 To 60 Degree Celsius ) Hematocrit Range 15-65%, Glucometer Strips:- Blood Sugar Strip Method For Diabetes Testing Blood Glucose Test Strips Glucostrips 1.The Assay Should Be Able To Detect Blood Glucose Level Of An Individual Using Blood Sample Type. ( Capiliary, Arterial, Venous And Neonatal ) The Assay Should Be A Room Temperature Stable Product. 2.The Assay Should Have 100% Sensitivity And 100% Specificity. 3.Blood Sample Size-0.6 Ml, Sample Reapplication Time 30 Sec 4.Testing Time-5 To 10 Sec 5.Tip Or Top Sample Application 6.Each Pack Contains 25 To 50 Strips, Calibration Bar To Provides Expiry Check And Test Strips Insert 7.Packed And Open Expiry Of Strips Are Same As Mentioned On The The Box Matching Iso 2013 And Ce Mark Approved, Hemoglobin Meter About Digital Haemoglobinometer:- 1. Display Screen:-Display Your Test Result, Date, Time, Etc. 2. Right, Left, Up, And Down Buttons:- To Move Among Display Items. 3. On / Off / Select Button: - To Turn The Meter On And Off, And To Select Displayed Items. 4. Test Strip Slot: - For Inserting The Strip. 5. Mini-Usb Charging Port:- For Charging The Battery. 6. Display Indicators :- Dd-Mm : Shows Date And Month 7. Batch Code : Indicates The Code Number Of Test Strips. 8. Battery Symbol :- Indicates The Battery Level 9. Strip Symbol: Indicates When To Insert Test Strip. 10. Blood Drop Symbol:-This Symbol Appears When The Meter Is Ready For You To Apply A Blood Drop. 11. Test Result Area : Displays The Hemoglobin Level. 12. Measurement Units : Indicates The Units For The Test Result ( G / Dl ) . 13. Light Indicator :When Ambient Light Intensity Is Higher Than Normal. 14. Temperature Symbol: Appears If Your Meter Is Out Of Operating Temperature Range. 15. Calibration Of Instruments To Be Done For Every 3000 Tests., Hemoglobin Meter Strips Hemoglobin Testing Strips 1. Should Accurately Detect Hemoglobin And Hematocrit 2. Quick And Easy To Use 3. Reliable And Portable 4. Each Pack Should Contain 25 Or 50 Wrapped Test Strips. 5. Expiry Date Should Be Mentioned. Accuracy: Haemoglobino Meter And Testing Strips Have To Be Validated. Certifications: Us Fda / Iso 13485:2016 / European Ce Certificate Storage Of Strips: Room Temperature Shelf Life: Minimum One Year From The Date Of Manufacture., Infrared Thermometer Accurate: Measure Flexibly & Accurately By Heimann Infrared Probe 2. Fast:Get The Data Within 1 Second 3. Alarm:Fever Alarm 4. Safe:Non Contact No Need Touch Your Body 5. Memory:Can Store 32 Sets Of Measurement Data 6. F To C:Free Transfer From Fahrenheit~ Centimeter Degree 7. Power Saving: Power Off Automatically 7 Seconds After Idle 8. Display:Display Temperature Clearly By Lcd, Pulseoximeter Patient Range. Adult And Pediatrics Patients. Spo2. Measurement Range. 35%~100% ... Pulse Rate. Measurement Range. 25 - 250 Bpm. ... Mechanical. Dimension 60Mm ( L ) * 34Mm ( W ) * 30Mm ( H ) ... Battery. Two Aaa 1.5V, 800Mah Alkaline Batteries About 30 Hours. Environmental. Operation Temperature 50C-400 C, Stadiometer : Stand Type Measuring Range:214Cm, Type:Folding, Application:Height Measuring, Accuracy:100%, Display:Manual, Folding: Fully Folding Strectcher, Material:Light Weight Abs, Graduation:Inmm, Weight:2.5Kg