Electric Works Division has published Tender For Quotation Inviting Basic Rate Of Material For Energy Department Jharkhand.. Submission Date for this Tender is 27-10-2022. Bolts Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supplying and fixing Decorative wall lamp chrome finish brass cap type E14, 1x5 watt LED dimension 215x120x115 model- Stratum 8513 etc as reqd. |
2 | Supplying and fixing Decorative floor lamp carbon steel aluminium with ivory fabrics shade floor lamp E-27 LED 9 watt x 1LWDH 2840 etc as reqd. |
3 | S/F Decorative Lamp post of height 1 mtr made out of cast Iron with base plate etc as reqd. Model-NAAYAB |
4 | S/F 25W LED CCT 3000 K Model- BCF DRA 25W LED OP TM Make- Bajaj |
5 | S.I.T.C of 5 KVA Automatic Voltage stabilzier input 90-300v Model-EML 5090 Make-Microtek |
6 | 12V, 26Ah sealed maintenance free (SMF) battery IS:1652:1991 |
7 | 12V, 7Ah sealed maintenance free (SMF) Battery for Lift call button |
8 | Supplying outdoor type 500KVA copper wound transformer continuosuly rated for 3 PH, 50 Hz at full load and temp, rese not exceeding 45C by thermometer in oil and 50c by the resistance in winding after continuous run at full load rating. The transformer should have oil immersed winding having having vector group DY 11, HT side connected in delta and LT side connected in star with netural brought out connected to provide sperate earthign the transformer shall have power terminal arrangemetn, bushing/cable end box on HT side and cable end box on LT side 2 nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have followign standard fittings, transformer shall be lates manufacturing standerds as per amended is specifications and the load and no lods looses shall be limited to values given below as per IS:2026 or Norms issued by SEB which ever are lower. |
9 | Oil conservator with fdilling holee with cap and plain oil level gauge |
10 | silica gel dehydrating breather charged with silica gel |
11 | oil drain valve |
12 | Oil filter vale |
13 | Lifting eyes/ Hooks |
14 | Tow earthign terminals |
15 | Diagram and rating plate |
16 | Air vent |
17 | Explosion Vent |
18 | 100 mm dia thermo meter with thermometer pocket |
19 | four be diretional plain roller |
20 | Supplying outdoor type 750KVA copper wound transformer continuosuly rated for 3 PH, 50 Hz at full load and temp, rese not exceeding 45C by thermometer in oil and 50c by the resistance in winding after continuous run at full load rating. The transformer should have oil immersed winding having having vector group DY 11, HT side connected in delta and LT side connected in star with netural brought out connected to provide sperate earthign the transformer shall have power terminal arrangemetn, bushing/cable end box on HT side and cable end box on LT side 2 nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have followign standard fittings, transformer shall be lates manufacturing standerds as per amended is specifications and the load and no lods looses shall be limited to values given below as per IS:2026 or Norms issued by SEB which ever are lower. |
21 | Oil conservator with fdilling holee with cap and plain oil level gauge |
22 | silica gel dehydrating breather charged with silica gel |
23 | oil drain valve |
24 | Oil filter vale |
25 | Lifting eyes/ Hooks |
26 | Tow earthign terminals |
27 | Diagram and rating plate |
28 | Air vent |
29 | Explosion Vent |
30 | 100 mm dia thermo meter with thermometer pocket |
31 | Four bi diretional plain roller |
32 | Comprehensive annual maintenance contract of 600 TR Trane Make water cooled contrigugal chiller units |
33 | CAMC of 2400 USGPM condenser pump |
34 | CAMC of 1600 USGPM Primary Pump |
35 | CAMC of 1600 USGPM Secondary Pump |
36 | CAMC of 1.1 KW Pressurization Pump |
37 | CAMC of 2400 USGPM Cooling Tower |
38 | CAMC of Ceiling supspension/ Floor mounting Air Handling Unit |
39 | CAMC of VAV Valves |
40 | Comprehensive Annual maintenance contract of Moterised Valves |
41 | Comprehensive annual mainteannce contract of Moterised fire damper |
42 | Comprehensive Annual maintenance contract of MCC Panel with VFD for pumping |
43 | Comprehensive annual mainteannce contractd of Building Management sysmte of AC side includgin licence, software update, maintenance of controller etc |
44 | Design, supply, installation, testing and commissioning of 29.5M stadium mast in 4 sections includgin headframe, safety cage ladder suitable for wind speed 44m/sec. and suitable to install 24 nos of LED luminaties in asymmetrical arrangemetn, supply of foundation bolts with nuts, washers, anchor plates and template M39 x 1500mm x 20 nos, PCD:1140 (Note 1 nos Template provided for 4 nos Mast) Make- Transrail/Bajaj/Surya/Phillips |
45 | Erection of above stadium lighting mast with suitable tools & with sutiable weight of approx 250 tone crane machine and labour. |
46 | Supply of marider Unit (Suitable to Carry 300 KG) along with its accessories, necessary hardware & anitfall arrestor etc. |
47 | Construction of shallow foundation with M25 grade concerte for the hgiht mast considering safe soil bearing capacity of 10T/mtrs sq at 2.5 metre depth with all materials and labour |
48 | Supply, installatin, testing & commissioning of 940/1000w LED stadiumm light with IP66 and IK08 Protection, system efficary =125lm/W, LED efficary = 140 lm/W, Build-in surge protection = 4KV, External surge protection =10KV power factor = 0.95, Beam angle-Upt 30/30 to 45/45 to 60/60 ot 120 or any other ss reqd. Make- Transrail/Bajaj/Surya/Phillips |
49 | Supply |
50 | Erection |
51 | Supply, Installation, testing & commissioning of single dome LED aviation |
52 | Supply |
53 | Erection |
54 | Supply, installation, testing & Commissionign of HMLDB outdoor feeder pillar type with follwing componant 1 no 63A 4P MCCB 25KA outgoing 2 nos each comprsing 1 nos 32A TPN MCB 1 nos 32A TP Contractors & 12 Nos 10 A SP MCB, Shall be installed at a suitable location and shall be erected on cement concrete foundtion complete. |
55 | Supply |
56 | Erection |
57 | Fabrication, supplying, installation, testing & Commissioning of outdoor type Main lighting distribution board (MLDB) made out of CRCA sheet with powder coating (RAL 7032) of suitable size with canopy having IP 54 Protection for accomodating the following component. the MLDB shall be installed at a suitable location and shall be erected on cement concrete foundation complete with painting, interconnections, earthing complete as reqd includgin the detachable gland plate for incoming and outgoing cables entry. stadium Mast lighting panel outdoor type with 1 no 315A 4P 35 KA MCCB and 4 nos 100A FP MCCB outgoing for feeding HMLD, 1no-320A changover, LED indicator, Volt meter & amp meter CT coil and with 25mm x 5mm copper tape |
58 | Supply |
59 | Erection |