Tender For Replacement Of Asbestos Sheet Roofing With Rcc Roof On Permanent Pucca Huts For Home Guard Personal Constructed At Different Rds Of Nangal Hydel Channel., nangal-Punjab

Bhakra Beas Management Board-BBMB has published Tender For Replacement Of Asbestos Sheet Roofing With Rcc Roof On Permanent Pucca Huts For Home Guard Personal Constructed At Different Rds Of Nangal Hydel Channel.. Submission Date for this Tender is 14-02-2023. Shed Construction Tenders in nangal Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

34428748
Corrigendum : Tender For Replacement Of Asbestos Sheet Roofing With Rcc Roof On Permanent Pucca Huts For Home Guard Personal Constructed At Different Rds Of Nangal Hydel Channel.
Open Tender
Indian
Punjab
nangal
14-02-2023

Tender Details

Replacement Of Asbestos Sheet Roofing With Rcc Roof On Permanent Pucca Huts For Home Guard Personal Constructed At Different Rds Of Nangal Hydel Channel.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Nov-2022 Corrigendum-II Date 15-12-2022
2 15-Dec-2022 Corrigendum-III Date 04-01-2023
3 04-Jan-2023 Corrigendum 4 Date 18-01-2023
4 18-Jan-2023 Corrigendum 5 Date 30-01-2023
5 30-Jan-2023 Corrigendum 6 Date 14-02-2023

Key Value

Document Fees
INR 2360 /-
EMD
INR 40370.0 /-
Tender Value
INR 20.18 Lakhs /-

BOQ Items

Name of Work: Replacement of Asbestos sheet roofing with RCC roof on Permanent Pucca huts for home guard personal constructed at different RD’s of Nangal Hydel Channel.
Sl. No. Item Description
1Civil Work
2Earth work in excavation in foundations, trenches etc.in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 meter. [ As per CSR-2020 item No. 6.6 ]
3Cement Concrete 1:5:10 with stone aggregate 40mm gauge mixing by mechanical meansusing concrete rate mixture volumetric type. [As per CSR-2020item No. 10.9 (b)-ii]
4Removing R S beams from structures or trusses.[As per CSR-2020 item No. 8.25]
5Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means). [As per CSR-2020 item No. 8.39]
6Scrapping bricks dismantled from brick work in lime or cement. [ As per CSR-2020 item No. 8.31-e ]
7First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. [As per CSR-2020 item No. 11.05]
8First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. [As per CSR-2020 Item No. 11.06 ]
9Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. [As per CSR-2020 item No. 10.21]
10115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in superstructure.[ As per CSR-2020 item No. 11.36]
11Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing inposition complete. [ As per CSR-2020 item No. 18.18 ]
12Bottom khurra on ground 1.2mm x 0.6 mm consisting of brick on-edge laid in cement mortar 1:3 over 7.5 cm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3. [As per CSR-2020 Item No. 13.51]
13Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. [ As per CSR-2020 item No. 9.8 ]
14Centering and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels. [ As per CSR-2020 item No. 9.6 ]
15Providing and fixing 110 mm dia. U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. [ As per CSR-2020 item No. 13.74 ]
16Providing and fixing 110 mm dia U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend. [As per CSR-2020 item No. 13.75-a ]
1712.5 mm thick cement plaster 1:5. [As per CSR-2020 item No. 15.10]
18Plastering on underside of ceiling 10 mm thick cement plaster 1:4. [As per CSR-2020 item No.15.44]
19Distempering with Acrylic washable oil bound distemper (of approved manufacture) one coat over one priming coat on old distempered surface. [As per CSR-2020 items No.16.11]
20Painting one coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. With ordinary quality Paint. [As per CSR-2020 item No. 16.19]
21Conglomerate floor 40mm thick cement concrete topping 1:2:4. (using mechanical mi x er for mi x ing the material). [As per CSR-2020 Item No. 14.6]
22White washing (Three coat) . [As per CSR-2020 item No.16.03]
23Water supply & Sanitary Installation -:
24Providing, laying, jointing, fixing & testing ISI marked GI pipe (as per IS:1239) B-class premium make such as ( JindalHisar) including cost of specials (such as tee, bends , sockets , elbows etc.) painting with anti-corrosive bit mastic paint,testing, cutting, threading in side building. Complete.15mm inner dia. [As perCSR-2020 item No.28.35-a ]
25Providing and fixing in position 15 mm inner diameter bib cock of approved make (to the approval of the engineer-in-charge) complete in all respect. Brass nozel bib cock 15 mmx250 gm. [As per CSR-2020 item No. 30.65 A-v)]
26Providing, fixing and jointing brass ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I Pipe lines including all carriage complete.15 mm i/d Brass ball valve. [As per CSR-2020 item No. 28.44-a]
27Providing, fixing and jointing GI union couplings ( of approved make with the approval of Engineer-in-charge ) as per IS:1879 in GI pipe lines complete in all respect.15 mm i/d G.I Union. [As per CSR-2020 item No. 28.40-a)
28Providing and laying, jointing fi x ing and testing ISI marked uPVC pipe lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respect. UPVC pipe 6 kgf/cm2 50 mm i/d [As per CSR-2020 item No. 28.12-B-b)
29Providing & Fixing in postion CP Brass bath tub spout with wall flange of approved make (to the approval of Engineer-in-charge) complete in all respect.[As per CSR-2020 item No. 30.52]
30ELECTRICAL WORKS
31RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:- Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (Without fan box) (As per CSR-2020 item No.34.02-i-a)
32RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:- Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring light point. (As per CSR-2020 item No.34.02-ii)
33RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:- Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring 6Amp. wall socket point (As per CSR-2020 item No.34.02-iv)
Disclaimer :