| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I |
| 3 | Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENT, EXCAVATION AND EARTH WORK as listed in Schedule \"A\" Part-II. |
| 4 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL Water Supplyas listed in Schedule \"A\" Part-III. |
| 5 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIFICATIONas listed in Schedule \"A\" Part-IV. |
| 6 | Lumpsum price worked out by the bidder/ tenderer for ROADS/CULVERT/ PATH & HARD STANDING as listed in Schedule \"A\" Part-V. |
| 7 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule \"A\" Part-VI. |
| 8 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule \"A\" Part-VII. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-VIII. |
| 10 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule \"A\" Part-IX. |
| 11 | Lumpsum price worked out by the bidder/ tenderer for SPECIAL REPAIR (B/R) ITEMS as listed in Schedule \"A\" Part-X. |
| 12 | Lumpsum price worked out by the bidder/ tenderer for SPECIAL REPAIR (E/M) ITEMS as listed in Schedule \"A\" Part-XI. |
| 13 | Lumpsum price worked out by the bidder/ tenderer for DEMOLITION/DISMANTLING /TAKING DOWN as listed in Schedule \"A\" Part-XII. |
| 14 | Sch \"A\" Sec-XI (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 signifies this fact only. |
| 15 | Taking down of CPVC pipe of 16 mm dia on wall /ceiling /floorsall as specified and directed by Engr-in-Charge |
| 16 | Taking down of CPVC pipe of 20 mm dia on wall /ceiling /floorsall as specified and directed by Engr-in-Charge |
| 17 | S&F 50mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls completeall as specified and directed by Engr-in-Charge |
| 18 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washerscompleteall as specified and directed by Engr-in-Charge |
| 19 | S&F in repairs CP Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed |
| 20 | S&F Aluminium handles 200 mm size, cast type, anodised complete all as specified and directed. |
| 21 | S&F of stainless steel railing Grade 304 as in railing vertical or horizontal all as specified and directed. |
| 22 | S&F of brass chromium plated health faucet with health faucet tube of 1.2 mtr long and standered accessories etc. suitable for 15mm bore pipe for WC all as specified and directed by Engr-in-Charge |
| 23 | M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one light/fan/bell point controlled byone, one way switch complete all as specified and directed by Engr-in-Charge |
| 24 | M & L for concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run ofFRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on Same board complete all as specified and directed by Engr-in-Charge |
| 25 | M & L for concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run ofFRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on independentboard complete all as specified and directed by Engr-in-Charge |
| 26 | M & L for concealed Point wiring with 2.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run ofFRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 5 pin 15 Amps socket out let on independent boardcomplete all as specified and directed by Engr-in-Charge |
| 27 | M & L for Concealed Point wiring with 4 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for for one 16 Amp socket outlet on independent board.all as specified and directed by Engr-in-Charge |
| 28 | Supply & fixing modular white cover plate with frame 12 module all as specified and directed by Engr-in-Charge |
| 29 | S & F blank speacer plate for single module all as specified and directed by Engr-in-Charge |
| 30 | Taking down/ dismantling copper/aluminium Sub main wiring of any size complete from site all as specified. |
| 31 | S&F inreplacement of sub main wiring (concealed type)single core FRLSH PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 4 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 4 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified &as directed by Engr-in-Charge.(Note -Two run single core cable, One run of earth conductor and one run of PVC conduit shall be measured as a unit length.) |
| 32 | S&F inreplacement of sub main wiring (concealed type)single core FRLSH PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 6 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 6 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified &as directed by Engr-in-Charge.(Note -Two run single core cable, One run of earth conductor and one run of PVC conduit shall be measured as a unit length.) |
| 33 | S&F inreplacement of sub main wiring (concealed type)single core FRLSH PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 10 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 10 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified &as directed by Engr-in-Charge.(Note -Two run single core cable, One run of earth conductor and one run of PVC conduit shall be measured as a unit length.) |
| 34 | Taking down / dismantling of DBs of any sizes complete all as specified andas directed by Engr-in-Charge. |
| 35 | Taking down / dismantling of ceiling fan 1200/1400 mm sweep from site & refixing the same after comletion of work including hook , nut bolt, washers alongwith electrical connection complete all as specified. |
| 36 | Supply and fixing LED bulb 9 Watts all as specified and directed. |
| 37 | Supply and fixing building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aliminium IP-66 high power LED light 20 wattcomplete with fixing arrangement including bracket etc all as specified and directed. |
| 38 | Supply and fixing PVC Board 30 x 25 x 5 Cm depthcomplete all as specified ad as directed by Engineer-in - charge. |
| 39 | Supply and fix in replacement factory made epoxy powder coated distribution baord TP&N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, Earth bar and cable management, top and bottom removable gland plastes with Knockout and including one FP-MCCB 160 Amps,35 KA as incomer and provision for 24 SP / 12 SPN MCBs or 6TPN MCBs (or any combination of SP/SPN/TP MCBs) outgoings complete all as specifiedand conforming to IS:8623 alongwith cable end box for above DBscomplete all as specified and directed |
| 40 | Supply and fix in replacement factory made epoxy powder coated distribution baord TP&N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, Earth bar and cable management, top and bottom removable gland plastes with Knockout and including one FP-MCCB 125 Amps,35 KA as incomer and provision for 24 SP / 12 SPN MCBs or 6TPN MCBs (or any combination of SP/SPN/TP MCBs) outgoings complete all as specifiedand conforming to IS:8623 alongwith cable end box for above DBs complete all as specified and as directed. |
| 41 | S & F service bracket for service cable including clamp, nut & bolt fixed on wall/ roof complete all as specified and directed |
| 42 | Material and labour for cuttingof road/ hard standingn exc 20cm widthandn exc 60cm in depth for laying of water pipe lines/cable protection including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1to match with existing surfacecomplete all as directed. |
| 43 | Material and labour for sand cushioning with dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed. Note-Punned thickness will be measured for payment |
| 44 | Supply & fixing bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed. |
| 45 | Supply, installation, testing and commisioning of CPRI approved LT Panel board outdoor type min IP54 protection fabricated with 3.15mm thick CRCA sheet steel front and rear openable vertical cubical type installed over properly supported legs suitablily grouted to PCCwith copper bus bar, phase indicator lamps & internal wiring including the following accessories (FPBA): -(a) INCOMING (i) MCCB 200A 4 Pole 415 V 35 KA- 01 No. (b) OUTGOING(i)MCCB 100A 3 Pole 415 V 25 KA -02 Nos (ii)MCCB 63 Amps, 3 pole, 415 V, 25 kA-02 Nos (iii) Digital ammeter of suitable range with 3 Nos CTs & selector switch - 1set (iv) Digital Voltmeter of suitable range with selector switch - 1 set. |
| 46 | Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead4 mm diaby means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm withreinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and20 mm bore galvanised iron pipe\"medium grade\" for watering with GI funnel and wire mess including charcoal and salt in alternate layersof 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion. |
| 47 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron 25 x 4 mm strip as earthing lead bymeans of galvanized steel bolts, nuts check nuts and washers and other end connected with to Transformer ,DG set,Panel Board etc as directed including funnel, 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1with 8mm dia cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No 5 of MES Schedule Part I and testing complete all as specified and as directed. |
| 48 | S&F new generation energy saving and environmental friendly long life 45W LED streetlight, 110lm/Watt, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP65 protection and impact resistance of IK07 LED and supply & fixing brackets made of 32mm bore galvanised iron light grade pipe made to shape having overall lenght 1.2 mtr, fixed over the vertical wall through two numbers mild steel clamp of 25 mm width, 3mm thick MS flat strip and four nos nuts, bolts & washers of 12mm dia 150mm long grouted into wall complete all as specified and directed. |
| 49 | S & F PVC junction box with MCB SP 20 Ampscomplete all as specified and directed. |
| 50 | M&L for constructing Septic tanks designed to carrry sewage and sullage water, exc in any type ofsoil,PCC 1:4:8 below foundation, Brick work in CM 1:4 in walls, Base slab, Baffle walls and roof slab (M-25 concrete) including beams etc with vent shaft manhole openings with cover connections etc complete for 50users complete all as specified and shown on drawings No TD/SZ/504 Sheet 1/1. |
| 51 | M & L forSoakage wells of size 1.8x3.0m, with all fittings and fixturescomplete all as specified and shown on drawing No. TD/SZ/502 sheet No 1/1 |
| 52 | M&L for constructing Septic tanks designed to carrry sewage and sullage water, exc in any type ofsoil,PCC 1:4:8 below foundation, Brick work in CM 1:4 in walls, Base slab, Baffle walls and roof slab (M-25 concrete) including beams etc with vent shaft manhole openings with cover connections etc completefor 100userscomplete all as specified and shown on drawings No TD/SZ/504 Sheet 1/1. |
| 53 | M & L forSoakage wells of size 2.4x3.0m, with all fittings and fixturescomplete all as specified and shown on drawing No. TD/SZ/502 sheet No 1/1 |
| 54 | M&L for constructing Septic tanks designed to carrry sewage and sullage water, exc in any type ofsoil,PCC 1:4:8 below foundation, Brick work in CM 1:4 in walls, Base slab, Baffle walls and roof slab (M-25 concrete) including beams etc with vent shaft manhole openings with cover connections etc completefor 150userscomplete all as specified and shown on drawingsNo TD/SZ/504 Sheet 1/1. |
| 55 | M & L forSoakage wells of size 3.0x3.0m, with all fittings and fixturescomplete all as specified and shown on drawing No. TD/SZ/502 sheet No 1/1 |
| 56 | M&L for 600 mm reinforced concrete pipes, class NP2, laid and jointed with collars incl cement concrete bed type C2 1:3:6 to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed |
| 57 | S&F Grating doom 100mm dia of chromium plated complete all as specified and directed. |
| 58 | S&F Grating doom 125 mm dia with waste hole of chromium plated complete all as specified and directed. |