Special Repair To Single Men Barrack ( Bldg No. P / 17 ) Damaged In Earthquake Of Hq 26 Sector Assam Rifles At Pallel., Pallel Mamang Leikai-Manipur

Assam Rifles-AR has published Special Repair To Single Men Barrack ( Bldg No. P / 17 ) Damaged In Earthquake Of Hq 26 Sector Assam Rifles At Pallel.. Submission Date for this Tender is 24-11-2022. Barrack Tenders in Pallel Mamang Leikai Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

34289904
Corrigendum : Special Repair To Single Men Barrack ( Bldg No. P / 17 ) Damaged In Earthquake Of Hq 26 Sector Assam Rifles At Pallel.
Open Tender
Indian
Manipur
Pallel Mamang Leikai
24-11-2022

Tender Details

Special Repair To Single Men Barrack ( Bldg No. P / 17 ) Damaged In Earthquake Of Hq 26 Sector Assam Rifles At Pallel.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Nov-2022 Extension of Bid Opening date Date 24-11-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 35700.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Special repair to Single Men Barrack (Bldg No. P/17) damaged in earthquake of HQ 26 Sector Assam Rifles at Pallel.
Sl. No. Item Description
1SCHEDULE ‘A’ PART - I (Repair of buildings)
2Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster incl disposal of rubbish to the dumping ground within 50 mtr lead.
3Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand).
4Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 m lead as per direction of Engineer - in- charge.
5Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
6Providing and laying 15 mm cement plaster on rough side of single or half brick wall ofcement of mix 1:4 (1 cement : 4 coarse sand)
7Reinforced cement concrete work in suspended floors, shelves, chajjas, lintels etc above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
8Providing and fixing in position of reinforcement (TMT bar), incl cutting to length, bent to shape required including cranking, bending etc complete.
9Centering and shuttering incl struting, propping etc and removal of form for slab.
10Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of CM 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Udaipur green marble.
11Pre finished nosing to treads of steps of marble stone
12Providing and laying Non skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
13Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, Shades except burgundy, bottle green, black of any size as approved by E-in -C, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
14Providing and laying vitrified floor tiles in 500x500mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
15Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 m lead for thickness of tiles 10 mm to 25 mm.
16Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coat applied @ 1.43 ltr/10 sqm over and incl priming coat of exterior primer applied @2.20 kg/10 sqm).
17Providing and finishing with two or more coats applied @ 1.43 ltr/10 Sqm over existing cement paint surface Premium Acrylic smooth exterior paint with silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
18Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete.
19Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two or more coats) over and incl water thinnable priming coat with cement primer.
20Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete.
21Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade,One or more coats on old work.
22Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 m lead nominal concrete 1:3:6 or richer mix in floor.
23Providing and laying PCC (1:3:6) in floor sub base with 20mm stone aggregates.
24Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
25Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand)
26Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain.
27Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
28Providing and laying APP modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/liter and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
29Painting with aluminium paint of approved brand and manufacture to give an even shade, one or more coats on old work .
30Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 m lead of area 3 Sqm and below.
31Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof 0.63mm dia wire and 1.4 aperture on both sides.
32Renewal of old putty of glass panes (length).
33Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with float glass panes of thickness 4 mm.
34Providing and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete.
35Dismantling doors shutters including chowkhats, holdfasts etc complete of area3 sqm and below.
36Providing and fixing of mosquito proof shutters using galvanized MS wire gauge of average width of aperature 1.4mm in both directions with wire of dia 0.63mm for door of 35mm with 2nd class teak wood.
37Providing and fixing to existing door frames, 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam.
38Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete
39Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete.
40Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm.
41Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type).
42SCHEDULE ‘A’ PART - II (Internal Electrifications)
43Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit incl dismantling as required (Group B)
44Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
45Supplying and fixing 5/6 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
46Supplying and fixing 15/16 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
47Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
48Supply and fixing brass batten/ angle holder including connection etc. as required.
49Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc.
50Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
51Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 16amp.
52Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 5amp.
53Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
54Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required.
55Supplying and drawing 2x2.5 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
56Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
57Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep.
58Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
59Switch fuse disconnector unit TPN, 62 Amps, 415 volts.
60Wiring for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required
61Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
62Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
63SCHEDULE ‘A’ PART - III (Repair of Plumbing and Sanitary fittings)
64Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead.
65Providing and fixing 10 ltr capacity (white) P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
66Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm.
67Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc.
68Providing and fixing 15 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc.
69Providing and fixing 25 mm dia nominal bore G.I. Pipes complete with G.I. Fittings including trenching and refilling etc.
70Providing and fixing of 15mm nominal bore CP bib cock of approved quality.
71Providing and fixing of 20 mm dia brass stop cock of approved quality etc. Complete.
72Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
73Providing and fixing of PTMT towel rail ring trapezoidal shape 215mm long, 200mm wide with minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality of 600mm long.
74Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
75Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, incl painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
76Providing and fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board backing fixed to wooden cleats with CP brass screws and washers complete.
77Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia.
78Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia.
79Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks.
80Providing and fixing of 15mm nominal bore CP angle cock of approved quality.
81Providing and fixing of 15mm nominal bore connection pipe of approved quality.
82Providing and fixing of 100mm dia CP brass shower rose with 15 or 20mm inlet of approved quality.
83Providing and fixing 25mm nominal bore gun metal gate valve with CI wheel of approved quality (screwed end)
Disclaimer :