Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling,ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I |
| 2 | Extra for earthwork in hard soil as per specification and directtonof E/l (Vide classification of soil item-B) |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches, within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of Measurement compacted volume.) |
| 4 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches, within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume.) |
| 5 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick wiih all leads and lifts including cost of all materials, labour, royaity and taxes all complete as per building specrfication and direction of E/l ( Mode of measurement compacted volume). |
| 6 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per bLrilding specification and direction of E/I |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level:1:3:6 (1 cement :3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level:1:2:4 (1 cement :2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- all work upto plinth level |
| 10 | Centering and shuttering including structting, Propping etc. and removal of form for Foundation, footings bases of columns , etc for masconcrete |
| 11 | reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding the cost of centering, shuttering, finishinng and reinforcement:1:1.5:3(1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size. |
| 12 | Centering and shuttering including structting, Propping etc. and removal of form for Columns, Pillars,Piers,Abutments, Posts and Strusts |
| 13 | reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajja, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishinng and reinforcement:1:1.5:3(1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size. |
| 14 | Centering and shuttering including structting, Propping etc. and removal of form for Lintels, Beam, Plinth Bemas, Girders, bressumers and Cantilivers |
| 15 | Centering and shuttering including structting, Propping etc. and removal of form for Suspended Floors, Roofs, Landings, Balconies and access platform |
| 16 | Centering and shuttering including structting, Propping etc. and removal of form for Stairs, (Excludings Landing) Excepts Spiral - staircases. |
| 17 | Providing designation 75 A brickwork in C M (1 :4 ) in foundation and ptinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/l. |
| 18 | Providing and laying damp-proof course 50mm thick with cement concrete 1:1.5:3(1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size. |
| 19 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:6) insuperstrure with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 20 | Providing designation 112 mm thick reinforced designation 100 A brick work with fly ash lirne brick (FLAG) confirming to lS 12894-1990 (9\"x4\"5\"x3\" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/|. |
| 21 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 22 | Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.Second Floor |
| 23 | Third Floor |
| 24 | Centering and shuttering including structting, Propping etc. and removal of form for weather Shade, Chajjas, corbels etc. including edgess |
| 25 | Providing Tor steel reinforcement of 8mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) |
| 26 | Providing Tor steel reinforcement of 10mm, 12mm & 16mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) |
| 27 | 10 mm (TMT Coil Fe 500) (Only Valid for SAIL & TATA Steel) |
| 28 | 12 mm (TMT Coil Fe 500) (Only Valid for SAIL & TATA Steel) |
| 29 | 16 mm (TMT Coil Fe 500) (Only Valid for SAIL & TATA Steel) |
| 30 | Providing Tor steel reinforcement of 10mm, 12mm & 16mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) |
| 31 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 32 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 33 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 34 | Providing and laying Doublecharge Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 35 | Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I. |
| 36 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 37 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 38 | Providing & laying 25 mm thick KOTAH STONE TILES FLOORING and skirting of approved size, texture and colour over 19 mm thick base of line mortar (1:1:1) Lime putty: Surkhi: Coarse sand) laid over and jointed with grey cement slurry mixed with pigment ot match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (600 X 600 MM) |
| 39 | Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: |
| 40 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade |
| 41 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade. |
| 42 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge.8.3.2 Granite work |
| 43 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/I. |
| 44 | Supplying fitting and fixing 250x20x6 mm L-type M.S.clamp properly fishtailed including making holes and setting the same in2 375 x 125 x 75 mm cement concrete block (1:2:4) with cost of all layout materials and taxes as per buiding specification and direction of E/I |
| 45 | Supplying, fitting & fixing 35mm, thick solid core type decorative double leaf flush door shutters with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminum fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 46 | Supplying, fitting & fixing 30mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminum fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 47 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 48 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete9.101.2 Twin rubber stopper |
| 49 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 50 | Providing and fixing factory made PVC door frame of size 50x47 mm witha wall thicknessof 5 mm, made out of extruded5 mm rigid PVC foam sheet, mitred at corners and jointed with 2 Nos.Of 150 mm long brackets of 15x 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mmM.S. square tube of 19 gauge, EPDMrubber gasket weather seal tobe provided through out of the frame. The door frame to be fixed to the wall using M.S. screwsof 65/ 100 mm size , complete as per manufacturer\"s specification and direction of E/I. |
| 51 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S tubes of 19 gauge thickness and size of 19 mm x19 mm for styles and 15 x15 mm for top & bottom rails M.S frame shall have a coat of steel primers of approved make and manifatureM.S frame covered with 5 mm thick heat mouldedPVC channel of size 30 mm thickness, 70 mm widthout of which 50 mmshallbe flatand 20 mmshall be tapperd in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVCsheet out of which 75 mm shall be flat and 20 mm shall tapperd in 45 degree on the inner sidetoformtop and bottom rail and 115 mm widePVC sheet out of which 75 mm shall be flat and 20 mm shall be tapperd on both sides toform lock rail.Top , bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x2 ) thick , 20 mm wide cross PVC sheet be provided as gapinsert for top rail & bottom rail, paneling of 5 mm thickboth side PVC sheet tobe fitted in the M.S. frame welded / sealed to the styles & rails with 7 mm (5mm +2 mm ) thickx 15 mmn wide PVC sheetbeading on inner side, and jointed together with solvent cement adhesive. An additional5 mm thick PVC strip of 20 mm width istobe stuck on the inner side ofthe \"C\"Channel usingPVC sovent adhesive etc. complete as per direction of E/I ,manufacturer\"s specification & drawing. |
| 52 | Providing and fixing factory made uPVC white colour sliding glazed windowupto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of equired size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 53 | Providing and fixing factory made uPVC white colour sliding/Panel glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion weldedat all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). |
| 54 | Providing and fixing glazing in aluminium / UPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm) |
| 55 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 56 | Supplying,frtting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I.(where materials is not supplied by the deptt.) |
| 57 | Supplying,fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20X\"10X2 mm. at 100mm. Centres and braced with M.S. flat diagonals 20 X 3mm, with top and bottom rails of T. iron 40x40x6mm with 38 mm dia steel pulleys complete with bolts, nuts, locking rrangements, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction E/I. |
| 58 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l.(Mode of measurement Area shall be multiplied by the co-efficient as indicated in bullding specification).Providing one coat of painting with ready |
| 59 | Providing Twocoat of Synthetic Enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I |
| 60 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 61 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plarsterecl sltrlace by rubbing smooth with pumice stone for fine sand paper, appiying putty wherever required, scaffolding washing of floor taxes all complete as per building specification and E/I |
| 62 | Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 63 | Providing and fixing fan hook of \"16 mm dia M.S. bar 1 metre long bent to required size and shape,placed in position and fixed in R.C.C slab/beam at the time of casting all complete as per building specification and direction of E/I. |
| 64 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200nmm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 65 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm Diameter |
| 66 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
| 67 | Single Pushfit Coupler - 110 mm |
| 68 | Bend 87.5 - 110mm bend |
| 69 | Shoe (Plain) - 110 mm Shoe |
| 70 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm Diameter |
| 71 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 72 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth. |
| 73 | Providing 250mm. wide brick drain in cement morta(1:6)with av.150mm. clear depth and 250mm. apron including cost of earthwork involved with 75mm. cement concrete (\"1:4:3) over one brick designation 75A,flat soling in proper grade and slope at the base,the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 74 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 75 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 76 | Waterproofing for Old and New RoofSlab :-Providingandlaying waterproofing treatment onroof slabby applyingtwo Component,factory designed, ready to use, acrylic modifiedflexible |
| 77 | Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3)maintaining slope inalternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm |
| 78 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium Composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approvedshop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 79 | CARRIAGE |
| 80 | Local Sand - 20 km |
| 81 | Stone Chips Lead - 22 km |
| 82 | Bricks - Lead -8 km (1k+7p) |
| 83 | Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 84 | Group C |
| 85 | Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVCInsuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required. |
| 86 | Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 87 | Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 88 | 2x2.5 sq mm+1x2.5 sq mm earth wire |
| 89 | 2x10 sq mm+2x6 sq mm earth wire |
| 90 | 4x10 sq mm+2x10 sq mm earth wire |
| 91 | 4x16 sq mm+2x16 sq mm earth wire |
| 92 | Teliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required |
| 93 | 2 Pair |
| 94 | S/F PVC conduit :-supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . |
| 95 | 25mm |
| 96 | S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 97 | 5/6 amps, one way switch |
| 98 | 5/6amps, 3 pin socket outlet |
| 99 | Teliphone socket with shutter outlet |
| 100 | S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 101 | S/F Modular boxes, base & cover plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 102 | 1 or 2 module(78mm x 78mm x 45mm) |
| 103 | S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 104 | S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 105 | S/F Batten holder:-Supplying and fixing batten/angle holder including connection etc, as required. |
| 106 | S/F Dingdong Call bell :-Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required. |
| 107 | ITC fluorescent fitting directly on surface:-Instaliation, testing and commissioning of prewired, fluorescent fitting of all types, complete with all accessosries and tube etc. directly on ceiling /wall including connection with 1.5 sq mm.FR PVC insulated, copper conductor. |
| 108 | ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 109 | ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 110 | S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required. |
| 111 | 100 amps, 16 KA fixed thermal seting |
| 112 | S/F Sheet metal ON/OFF-Load chenge over:-Providing and fixing following capacity 2 pole/ 4 pole ON/OFF-Load chenge over switches with side handle opreation, in sheet inclosure in existing panel board including drilling holes in metal board, making connection, earthing the body etc as required |
| 113 | 100 amps, 4 pole |
| 114 | S/F VERTICAL TYPE T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) Note:- Vertical type MCB TPDB is normally used where three phase outlets are required. |
| 115 | 4 way (4+24),Double door,Vertical type |
| 116 | S/F T.P.MCB DB:-Supplying and fixing following way Single pole and neutral,sheet Steel,MCB distribution board,240 volt,on surface/recess, complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 117 | 8way SPN MCB DB DOUBLE DOOR |
| 118 | S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 119 | 4 way (4+12),Double door, Horizontal type |
| 120 | S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 121 | 6/32 amps,single pole, \"B\" SERIES |
| 122 | S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 123 | 6/32 amps,single pole |
| 124 | 40 amp DP MCB |
| 125 | 40 amps,TPN (TO BE FIX IN VTPN DB) |
| 126 | P/F M.V. danger notice plate:-Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required. |
| 127 | G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 128 | salt/ Charcole for plate earth electrode |
| 129 | S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 130 | MV cable laying upto 25 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 25 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 131 | MV cable laying upto 95 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35sq.mm. but not exceeding 95 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 132 | S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1) |
| 133 | 50sq.mm. 3.5 core |
| 134 | 95 sq.mm. 3.5 core |
| 135 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 136 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 137 | Panel for ACs: Supplying, designing, manufacturing, installation, testing and commissioning of panel fabricated out of 2mm thick(14SWG) CRCA sheet steel, dust and vermin proofwith reinforcement of suitable size iron channel of suitable size with proper lifting arrangement effecting proper connection of all incomer and out going (IP-43) fully compartmentalized cubical type wallmounted, totally enclosed, switch board and suitable for use on 415V, 3 phase, AC Supply, 4 wire, 50 C/S, system having 25 kA fault capacity, housed with incoming and outgoing aluminum bus bars, interconnection, interlocking between feeders etc. with indicating lamps, push buttons, necessary accessories, all out goingfeeders protectionas required. |
| 138 | The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs |
| 139 | All openings shall be covered by soft rubber gasket, enclosure shall be galvanized. Panel shall have suitable cable entry from bottom and suitable arrangement for multi runs aluminum cables for all MCCB. Panel shall have individual compartment with name plate. |
| 140 | Panel Size - As per Drawing and shall be provided at the time of work order. |
| 141 | The Name Plate for each incoming & outgoing feeder must be in Anodized Aluminium Sheet. |
| 142 | BUS BARS SECTIONS |
| 143 | The panel includes 415V, 300A, 3Ph, 25kA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) Aluminium Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects.The current density of bus bar shall be minimum 0.8 A /sq.mm. Al. Bars up to 63A capacity. Otherinter connections shall be made with 2.5 and 4 Sq mm PVC Cu. wire. |
| 144 | Make of MCCB - L&T D-Sine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL/ ABB-T MAX/C&S |
| 145 | Make of MCB - (10kA-C-Series.) L&T/ Legrand/ Schneider / Siemens/ABB/ C&S |
| 146 | The above panel consisting of the following:- |
| 147 | Note:- All FP/MCCBshall be withthermomagnetic based release type andshall be with spreader links and front rotary handles. |
| 148 | Incomer |
| 149 | 1 no-250A ,415V, 4P/25kAMCCB with thermo-magnetic based released type with O/L, S/Cprotection with adjustable current with spreader links and extended rotary handle. |
| 150 | 1no-Rotary handle |
| 151 | 1 no-Spreader Link |
| 152 | Indicator |
| 153 | Digital Am-meter, three phase |
| 154 | Digital Volt-meter, three phase |
| 155 | CT 200/5VA -5 class one Epoxy resin cast CT(3 Nos.)=1 Set. Make:-Kappa / Matrix |
| 156 | Phase indicating light shall be protected by 2 Amps SP MCB\"s for incomer.Make-L& T./ AE/ Schneider. |
| 157 | Outgoings |
| 158 | 3 nos-40A FP/16kA, MCCBwith thermomagnetic release type andshall be with spreader links and front rotary handles. including suitable arrangementfor cable connection on one side and Bus bar connection on other side. |
| 159 | 32A DP/10kA MCB-\"C-series\"- 12 no |
| 160 | AL. bus bar of continious rating200A |
| 161 | Mechanicalitems:-Nuts, bolts, washers , doorlocks etc |
| 162 | Electrical Items: Cu wires of different sizes, cable lugs, sleeves, insulators, cable ties ,termianls etc+ labour charges |
| 163 | SITC ofBLDC Ceiling Fan: Supplying and fitting ofBLDC5 Star, 32W, 1200 mm Sweep AC ceiling fan ,including connection with 1.5 sq mm copper wire, down rodof standared length(upto 30cm) withall accessories as required. Make :- Polar/Bajaj/Crompton / Havells / GEC. |
| 164 | LED Bulb 9W/10W : Supplying and fixingofLED 9W /10W bulb and accessories as required. ( Make -Bajaj / Havells/ Philips/ Wipro) |
| 165 | SITCof Metal Exhaust Fan 12\"(300mm): Supply of12\"(300mm), 230V ACmetal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required( Make- Polar/Bajaj/ Havells/Crompton) |
| 166 | Providing of surface mounted 15 /16 WATT LED Round downlighter |
| 167 | LED Floodlights 120W :Environmental friendly, new generation,aesthetically designed, ultra modern LED floodlightluminaire with high diecast housingand IP66 protection.( make: Wipro /Havells/Bajaj/ Philips) |
| 168 | LED tube with Batten 20W/22W : Supplying and fixingof wall mountedLED 20W /22W tube + batten and electronic driverand accessories as required. ( Make -Wipro/Bajaj / Havells/ Philips) |
| 169 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \"p\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. |
| 170 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l . |
| 171 | Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \"p\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. |
| 172 | (B) With \"P\" trap (a)10 lit. low level P.V.C cistern |
| 173 | Special type of C.P. Bath room fittings for V.I.P. buildings (JAL, Jaquar, Marc or equivalent mark) |
| 174 | Long Body Bib Cock |
| 175 | Special type of C.P. Bath room fittings for V.I.P. buildings (JAL, Jaquar, Marc or equivalent mark) |
| 176 | Soap Dish |
| 177 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore |
| 178 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 gms |
| 179 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 180 | 25 mm nominal bore |
| 181 | 40 mm nominal bore |
| 182 | Supplying , fitting and fixing the following items complete with all materials as per specification and direction of E/I |
| 183 | mirror of 6 mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror |
| 184 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 185 | 125 mm nominal dia with 25 mm waste hole |
| 186 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length |
| 187 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 188 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 189 | Single tee with door |
| 190 | 110 mm |
| 191 | 110 mmbend |
| 192 | Coupler |
| 193 | 110mm Place trape |
| 194 | Providing and fixing on wall face unplasticised Rigid PVC waste water and soil pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (I) Single socketed pipes. 12.41.1 75 mm diameter |
| 195 | Single tee with door75 mm |
| 196 | Bend 87.5° 75 mm |
| 197 | Shoe (Plain) 75 mm |
| 198 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete75 mm |
| 199 | 110 mm |
| 200 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes |
| 201 | 20 mm nominal outer dia Pipes |
| 202 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 203 | 25 mm nominal outer dia Pipes |
| 204 | 32 mm nominal outer dia Pipes |
| 205 | 40 mm nominal outer dia Pipes |
| 206 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the wallswherever required : |
| 207 | Special type of C.P. Bath room fittings for V.I.P. buildings (JAL, Jaquar, Marc or equivalent mark) |
| 208 | Swan Neck Tap with left hand operating Knob |
| 209 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 210 | 150 mm dia. R.C.C. pipe (253+25.30+95.02) |
| 211 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of \"Hindustan\" \" Parry\" or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l. |
| 212 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 213 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation andrefilling all complete as per specification and direction of E/l. |
| 214 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 215 | Centering and shuttering including structting, Propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 216 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 217 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l. |
| 218 | Supplying & Fixing C.I. Cover without frame -do-do- all complete job455mm x 610 mm Rectangular |
| 219 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm Square Bar |
| 220 | Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm Dia |
| 221 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 222 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation andrefilling all complete as per specification and direction of E/l. |
| 223 | Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 224 | Providing tuck pointing [1:3] in cement on brick work clean coarse sand of F.M 1.5 FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all completeas per building specification and direction of E/I |
| 225 | Providing 12mmcement plaster(1:3) with clean course sand of F.M 1.5 with floatingcoat of neat cement in skirting including rounding of junctions with floor, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 226 | Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs, confirming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of engineer-in-charge.100 mm nominal size dia. - |
| 227 | Supplying,filling, spreading and levelling stone boulders of of size range 5cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. |
| 228 | Supplying,filling, spreading and levelling gravels of size range, 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders,in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. |
| 229 | Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. |
| 230 | 150 MM dia R.C.C. pipe |
| 231 | 250 MM dia R.C.C. pipe |
| 232 | HYDT:Cost of Drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in Rural) area for Installation of pump set with Hydraulic DTH Ring machine, all complete including supplying all materials, tools, drilling, rig, Air Compressor and Equipments, as well as fuel, lubricants and cost of Transportation of Rig Machine and other Vehicle up to site. |
| 233 | From 0.0M to 50.0 M |
| 234 | From 51 M to 125.00 M |
| 235 | Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6 mm wall thickness including welding charges, cost of Pipe etc. including all taxes, VAT, Excise duty, Fright charges with inspection charges etc. as applicable, etc. all complete Jobs. |
| 236 | Supplying all tools, Equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per direction E/I (Basic rate) |
| 237 | Supplying all materials, labours, tools & equipments for fitting & fixing 200 mm dia M.S.Cap over Casing Pipe including all taxes, VAT, Excise duty, Fright charges with inspection charges etc. as applicable, etc. all complite Jobs. |
| 238 | Supplying 100 mm dia Submersible Pump Set Conforming to IS : 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and Polypropylene / Noryl impeller. Motor suitable for working on 415V+10%, 3PH, 50Hz, A.C. Supply with cable guard, thurst carbon / fiber bearing to with stand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall be suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump. |
| 239 | Submersible Pump set 100 mm dia( with Polypropylene / Noryl impeller ) up to 20 stages. |
| 240 | 2 HP |
| 241 | D.O.L. starter with SS Enclosure with 380/415 volt coil as per IS: 391410.0 H.P. |
| 242 | 3.5 Core PVC insulated, PVC sheathed copper conductor flat submersible cable. |
| 243 | G.I.FITTINGS ( CONFORMING TO I.S. - 1979 (K) G.I. PIPES ( TATA MARK ) OR EQUIVALENT40 mm dia G.I. Pipe |
| 244 | Add 18% GST |
| 245 | Add 1% Labour cess 1% |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy