| 1 | RATE SCHEDULE FOR UNIT#3&4 OF 2X210MW PTPP PARICHHA JHANSI |
| 2 | Provision of New Coils as per applicable scope of workfor Category- I Motors 340 – 375 |
| 3 | Provision of New Coils as per applicable scope of work for Category- II Motors 600 – 660. |
| 4 | Provision of New Coils as per applicable scope of work for Category- III Motors 1300-1600. |
| 5 | Provision of New Coils as per applicable scope of workfor Category- IV Motors 3600. |
| 6 | Re-insulation of old coils as per scope of work for Category- I Motors 340 – 375. |
| 7 | Re-insulation of old coils as per scope of work for Category- II Motors 600 – 660. |
| 8 | Re-insulation of old coils as per scope of work for Category- III Motors 1300-1600. |
| 9 | Re-insulation of old coils as per scope of work for Category- IV Motors 3600. |
| 10 | Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- I Motors 340 – 375. |
| 11 | Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- II Motors 600 – 660. |
| 12 | Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- III Motors 1300-1600. |
| 13 | Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- IV Motors 3600. |
| 14 | Replacement of damaged Motor Terminal Leads as per scopeof workfor Category- I Motors 340 – 375. |
| 15 | Replacement of damaged Motor Terminal Leads as per scopeof work for Category- II Motors 600 – 660. |
| 16 | Replacement of damaged Motor Terminal Leads as per scopeof workfor Category- III Motors 1300-1600. |
| 17 | Replacement of damaged Motor Terminal Leads as per scopeof work for Category- IV Motors 3600. |
| 18 | Complete Restaggering of Stator core as per scope of work for Category- I Motors 340 – 375. |
| 19 | Complete Restaggering of Stator core as per scope of work for Category- II Motors 600 – 660. |
| 20 | Complete Restaggering of Stator core as per scope of work for Category- III Motors 1300-1600. |
| 21 | Complete Restaggering of Stator core as per scope of workfor Category- IV Motors 3600. |
| 22 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per scope of work) Category-I Bowl Mill Motor 340KW. |
| 23 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per scope of work) Category-I TAC Motor 350KW. |
| 24 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-I ACW Pump Motor 375KW. |
| 25 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-II CEP Motor 600KW. |
| 26 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work Sl. No 4.1 to 4.22 (Charges for new bars/end rings shall be payable as per Sl. No. 2a& 2b) Category-II FD Fan Motor 660KW. |
| 27 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per scope of work) Category-III PA Fan Motor 1300KW. |
| 28 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per scope of work) Category-III ID Fan Motor 1550KW. |
| 29 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per) Category-III CW Pump Motor 1600KW. |
| 30 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per scope of work) Category-IV BFP Motor 3600KW. |
| 31 | Replacement of damaged rotor Bars/ End rings (without rotor core re-staggering) as per scope of work. |
| 32 | Cost of New bars for Category-I Bowl Mill Motor 340KW. |
| 33 | Cost of New bars for Category-I TAC Motor 350KW. |
| 34 | Cost of New bars for Category-I ACW Pump Motor 375KW. |
| 35 | Cost of New bars for Category-II CEP Motor 600KW. |
| 36 | Cost of New bars forCategory-II FD Fan Motor 660KW. |
| 37 | Cost of New bars for Category-III PA Fan Motor 1300KW. |
| 38 | Cost of New bars for Category-III ID Fan Motor 1550KW. |
| 39 | Cost of New bars for Category-III CW Pump Motor 1600KW. |
| 40 | Cost of New bars for Category-IV BFP Motor 3600KW. |
| 41 | Cost of New End Ring for Category-I Bowl Mill Motor 340KW. |
| 42 | Cost of New End Ring forCategory-I TAC Motor 350KW. |
| 43 | Cost of New End Ring for Category-I ACW Pump Motor 375KW. |
| 44 | Cost of New End Ring for Category-II CEP Motor 600KW. |
| 45 | Cost of New End Ring for Category-II FD Fan Motor 660KW. |
| 46 | Cost of New End Ring forCategory-III PA Fan Motor 1300KW. |
| 47 | Cost of New End Ring for Category-III ID Fan Motor 1550KW. |
| 48 | Cost of New End Ring for Category-III CW Pump Motor 1600KW. |
| 49 | Cost of New End Ring forCategory-IV BFP Motor 3600KW. |
| 50 | Brazing Charges Category-I Bowl Mill Motor 340KW. |
| 51 | Brazing Charges Category-I TAC Motor 350KW. |
| 52 | Brazing Charges Category-I ACW Pump Motor 375KW. |
| 53 | Brazing Charges Category-II CEP Motor 600KW. |
| 54 | Brazing Charges Category-II FD Fan Motor 660KW. |
| 55 | Brazing Charges Category-III PA Fan Motor 1300KW. |
| 56 | Brazing Charges Category-III ID Fan Motor 1550KW. |
| 57 | Brazing Charges Category-III CW Pump Motor 1600KW. |
| 58 | Brazing Charges Category-IV BFP Motor 3600KW. |
| 59 | Mechanical works on Rotor |
| 60 | Dynamic balancing of Rotor Category-I Bowl Mill Motor 340KW. |
| 61 | Dynamic balancing of Rotor Category-I TAC Motor 350KW. |
| 62 | Dynamic balancing of Rotor Category-I ACW Pump Motor 375KW. |
| 63 | Dynamic balancing of Rotor Category-II CEP Motor 600KW. |
| 64 | Dynamic balancing of Rotor Category-II FD Fan Motor 660KW. |
| 65 | Dynamic balancing of Rotor Category-III PA Fan Motor 1300KW. |
| 66 | Dynamic balancing of Rotor Category-III ID Fan Motor 1550KW. |
| 67 | Dynamic balancing of Rotor Category-III CW Pump Motor 1600KW. |
| 68 | Dynamic balancing of Rotor Category-IV BFP Motor 3600KW. |
| 69 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-I Bowl Mill Motor 340KW. |
| 70 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-I TAC Motor 350KW. |
| 71 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-I ACW Pump Motor 375KW. |
| 72 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-II CEP Motor 600KW. |
| 73 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-II FD Fan Motor 660KW. |
| 74 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-III PA Fan Motor 1300KW. |
| 75 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-III ID Fan Motor 1550KW. |
| 76 | Repair of rotor shaft at Bearing Seat. as per scope of workCategory-III CW Pump Motor 1600KW. |
| 77 | Repair of rotor shaft at Bearing Seat. as per scope of work Category-IV BFP Motor 3600KW. |
| 78 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-I Bowl Mill Motor 340KW. |
| 79 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-I TAC Motor 350KW. |
| 80 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-I ACW Pump Motor 375KW. |
| 81 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-II CEP Motor 600KW. |
| 82 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-II FD Fan Motor 660KW. |
| 83 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-III PA Fan Motor 1300KW. |
| 84 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-III ID Fan Motor 1550KW. |
| 85 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-III CW Pump Motor 1600KW. |
| 86 | Repair of rotor shaft at Coupling Seat. as per scope of work Category-IV BFP Motor 3600KW. |
| 87 | Removing rotor shaft bend/run out as per scope of work Category-I Bowl Mill Motor 340KW. |
| 88 | Removing rotor shaft bend/run out as per scope of work Category-I TAC Motor 350KW. |
| 89 | Removing rotor shaft bend/run out as per scope of work Category-I ACW Pump Motor 375KW. |
| 90 | Removing rotor shaft bend/run out as per scope of work Category-II CEP Motor 600KW. |
| 91 | Removing rotor shaft bend/run out as per scope of workCategory-II FD Fan Motor 660KW. |
| 92 | Removing rotor shaft bend/run out as per scope of workCategory-III PA Fan Motor 1300KW. |
| 93 | Removing rotor shaft bend/run out as per scope of work Category-III ID Fan Motor 1550KW. |
| 94 | Removing rotor shaft bend/run out as per scope of work Category-III CW Pump Motor 1600KW. |
| 95 | Removing rotor shaft bend/run out as per scope of work Category-IV BFP Motor 3600KW. |
| 96 | Re-shafting of rotoras per scope of work Category-I Bowl Mill Motor 340KW. |
| 97 | Re-shafting of rotoras per scope of work Category-I TAC Motor 350KW. |
| 98 | Re-shafting of rotoras per scope of work Category-I ACW Pump Motor 375KW. |
| 99 | Re-shafting of rotor as per scope of work Category-II CEP Motor 600KW. |
| 100 | Re-shafting of rotor as per scope of work Category-II FD Fan Motor 660KW. |
| 101 | Re-shafting of rotor as per scope of work Category-III PA Fan Motor 1300KW. |
| 102 | Re-shafting of rotor as per scope of work Category-III ID Fan Motor 1550KW. |
| 103 | Re-shafting of rotor as per scope of work Category-III CW Pump Motor 1600KW. |
| 104 | Re-shafting of rotor as per scope of work Category-IV BFP Motor 3600KW. |
| 105 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-I Bowl Mill Motor 340KW.. |
| 106 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-I TAC Motor 350KW. |
| 107 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-I ACW Pump Motor 375KW. |
| 108 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-II CEP Motor 600KW. |
| 109 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-II FD Fan Motor 660KW. |
| 110 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-III PA Fan Motor 1300KW. |
| 111 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-III ID Fan Motor 1550KW. |
| 112 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-III CW Pump Motor 1600KW. |
| 113 | To & Fro transportation charges for rotor if it is sent alone for balancing &/ or repair of bearing/coupling seat for Category-IV BFP Motor 3600KW. |
| 114 | RATE SCHEDULE FOR UNIT#5&6 OF 2X250MW PTPP PARICHHA JHANSI |
| 115 | Provision of New Coils as per applicable scope of workfor Category- I Motors 220 -325 KW. |
| 116 | Provision of New Coils as per applicable scope of workfor Category- II Motors 450 – 550 KW. |
| 117 | Provision of New Coils as per applicable scope of work for Category- III Motors 1500-1750 KW. |
| 118 | Provision of New Coils as per applicable scope of work for Category- IV Motors 4600. |
| 119 | Re-insulation of old coils as per applicable scope of workfor Category- I Motors 220 -325 KW. |
| 120 | Re-insulation of old coilsas per applicable scope of workfor Category- II Motors 450 – 550 KW. |
| 121 | Re-insulation of old coilsas per applicable scope of work for Category- III Motors 1500-1750 KW. |
| 122 | Re-insulation of old coilsas per applicable scope of work for Category- IV Motors 4600. |
| 123 | Complete rewinding of stator with new or old reinsulated coils as per applicable scope of workfor Category- I Motors 220 -325 KW. |
| 124 | Complete rewinding of stator with new or old reinsulated coils as per applicable scope of workfor Category- II Motors 450 – 550 KW. |
| 125 | Complete rewinding of stator with new or old reinsulated coils as per applicable scope of work for Category- III Motors 1500-1750 KW. |
| 126 | Complete rewinding of stator with new or old reinsulated coils as per applicable scope of work for Category- IV Motors 4600. |
| 127 | Replacement of damage motor terminal leads as per applicable scope of workfor Category- I Motors 220 -325 KW. |
| 128 | Replacement of damage motor terminal leadsas per applicable scope of workfor Category- II Motors 450 – 550 KW. |
| 129 | Replacement of damage motor terminal leadsas per applicable scope of work for Category- III Motors 1500-1750 KW. |
| 130 | Replacement of damage motor terminal leadsas per applicable scope of work for Category- IV Motors 4600. |
| 131 | Complete Re-staggering of stator core as per applicable scope of workfor Category- I Motors 220 -325 KW. |
| 132 | Complete Re-staggering of stator coreas per applicable scope of workfor Category- II Motors 450 – 550 KW. |
| 133 | Complete Re-staggering of stator coreas per applicable scope of work for Category- III Motors 1500-1750 KW. |
| 134 | Complete Re-staggering of stator coreas per applicable scope of work for Category- IV Motors 4600. |
| 135 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-I TAC Motor 220KW. |
| 136 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-I ACW Motor 250KW. |
| 137 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-I BAHP Motor 280 KW. |
| 138 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-I CEP Motor325 KW. |
| 139 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-II Mill Motor 450 KW. |
| 140 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per ) Category-II FD Fan Motor 550 KW. |
| 141 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-III CW Motor 1500KW. |
| 142 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-III PA fan Motor 1650KW. |
| 143 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per Scope of work) Category-III ID fan Motor 1750KW. |
| 144 | Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work(Charges for new bars/end rings shall be payable as per scope of work) Category-IV BFP Motor 4600KW. |
| 145 | Replacement of damaged rotor Bars/ End rings (without rotor core re-staggering) as per scope of work. |
| 146 | Cost of new bar for Category-I TAC Motor 220KW. |
| 147 | Cost of new bar for Category-I ACW Motor 250KW. |
| 148 | Cost of new bar for Category-I BAHP Motor 280 KW. |
| 149 | Cost of new bar forCategory-I CEP Motor325 KW. |
| 150 | Cost of new bar forCategory-II Mill Motor 450 KW. |
| 151 | Cost of new bar for Category-II FD Fan Motor 550 KW. |
| 152 | Cost of new bar for Category-III CW Motor 1500KW. |
| 153 | Cost of new bar for Category-III PA fan Motor 1650KW. |
| 154 | Cost of new bar forCategory-III ID fan Motor 1750KW. |
| 155 | Cost of new bar forCategory-IV BFP Motor 4600KW. |
| 156 | Cost of new end ring for Category-I TAC Motor 220KW. |
| 157 | Cost of new end ring for Category-I ACW Motor 250KW. |
| 158 | Cost of new end ring for Category-I BAHP Motor 280 KW. |
| 159 | Cost of new end ring forCategory-I CEP Motor325 KW. |
| 160 | Cost of new end ring forCategory-II Mill Motor 450 KW. |
| 161 | Cost of new end ring for Category-II FD Fan Motor 550 KW. |
| 162 | Cost of new end ring for Category-III CW Motor 1500KW. |
| 163 | Cost of new end ring for Category-III PA fan Motor 1650KW. |
| 164 | Cost of new end ring forCategory-III ID fan Motor 1750KW. |
| 165 | Cost of new end ring forCategory-IV BFP Motor 4600KW. |
| 166 | Brazing Charges for Category-I TAC Motor 220KW. |
| 167 | Brazing Charges for Category-I ACW Motor 250KW. |
| 168 | Brazing Charges for Category-I BAHP Motor 280 KW. |
| 169 | Brazing Charges forCategory-I CEP Motor325 KW. |
| 170 | Brazing Charges forCategory-II Mill Motor 450 KW. |
| 171 | Brazing Charges for Category-II FD Fan Motor 550 KW. |
| 172 | Brazing Charges for Category-III CW Motor 1500KW. |
| 173 | Brazing Charges for Category-III PA fan Motor 1650KW. |
| 174 | Brazing Charges forCategory-III ID fan Motor 1750KW. |
| 175 | Brazing Charges forCategory-IV BFP Motor 4600KW. |
| 176 | Mechanical works on Rotor |
| 177 | Dynamic balancing of rotor for Category-I TAC Motor 220KW. |
| 178 | Dynamic balancing of rotor for Category-I ACW Motor 250KW. |
| 179 | Dynamic balancing of rotor for Category-I BAHP Motor 280 KW. |
| 180 | Dynamic balancing of rotor forCategory-I CEP Motor325 KW. |
| 181 | Dynamic balancing of rotor forCategory-II Mill Motor 450 KW. |
| 182 | Dynamic balancing of rotor for Category-II FD Fan Motor 550 KW. |
| 183 | Dynamic balancing of rotor for Category-III CW Motor 1500KW. |
| 184 | Dynamic balancing of rotor for Category-III PA fan Motor 1650KW. |
| 185 | Dynamic balancing of rotor forCategory-III ID fan Motor 1750KW. |
| 186 | Dynamic balancing of rotor forCategory-IV BFP Motor 4600KW. |
| 187 | Repair of rotor shaft at bearing seat for Category-I TAC Motor 220KW. |
| 188 | Repair of rotor shaft at bearing seat for Category-I ACW Motor 250KW. |
| 189 | Repair of rotor shaft at bearing seat for Category-I BAHP Motor 280 KW. |
| 190 | Repair of rotor shaft at bearing seat forCategory-I CEP Motor325 KW. |
| 191 | Repair of rotor shaft at bearing seat forCategory-II Mill Motor 450 KW. |
| 192 | Repair of rotor shaft at bearing seat for Category-II FD Fan Motor 550 KW. |
| 193 | Repair of rotor shaft at bearing seat for Category-III CW Motor 1500KW. |
| 194 | Repair of rotor shaft at bearing seat for Category-III PA fan Motor 1650KW. |
| 195 | Repair of rotor shaft at bearing seat forCategory-III ID fan Motor 1750KW. |
| 196 | Repair of rotor shaft at bearing seat forCategory-IV BFP Motor 4600KW. |
| 197 | Repair of rotor shaft at coupling seat for Category-I TAC Motor 220KW. |
| 198 | Repair of rotor shaft at coupling seatfor Category-I ACW Motor 250KW. |
| 199 | Repair of rotor shaft at coupling seat for Category-I BAHP Motor 280 KW. |
| 200 | Repair of rotor shaft at coupling seatforCategory-I CEP Motor325 KW. |
| 201 | Repair of rotor shaft at coupling seatforCategory-II Mill Motor 450 KW. |
| 202 | Repair of rotor shaft at coupling seatfor Category-II FD Fan Motor 550 KW. |
| 203 | Repair of rotor shaft at coupling seatfor Category-III CW Motor 1500KW. |
| 204 | Repair of rotor shaft at coupling seatfor Category-III PA fan Motor 1650KW. |
| 205 | Repair of rotor shaft at coupling seatforCategory-III ID fan Motor 1750KW. |
| 206 | Repair of rotor shaft at coupling seatforCategory-IV BFP Motor 4600KW. |
| 207 | Removing rotor shaft bend/run out for Category-I TAC Motor 220KW. |
| 208 | Removing rotor shaft bend/run outfor Category-I ACW Motor 250KW. |
| 209 | Removing rotor shaft bend/run out for Category-I BAHP Motor 280 KW. |
| 210 | Removing rotor shaft bend/run out forCategory-I CEP Motor325 KW. |
| 211 | Removing rotor shaft bend/run out forCategory-II Mill Motor 450 KW. |
| 212 | Removing rotor shaft bend/run outfor Category-II FD Fan Motor 550 KW. |
| 213 | Removing rotor shaft bend/run outfor Category-III CW Motor 1500KW. |
| 214 | Removing rotor shaft bend/run outfor Category-III PA fan Motor 1650KW. |
| 215 | Removing rotor shaft bend/run outforCategory-III ID fan Motor 1750KW. |
| 216 | Removing rotor shaft bend/run outforCategory-IV BFP Motor 4600KW. |
| 217 | Re-shafting of rotor as per scope of work Category-I TAC Motor 220KW. |
| 218 | Re-shaftingof rotor as per scope of work Category-I ACW Motor 250KW. |
| 219 | Re-shafting of rotor as per scope of work Category-I BAHP Motor 280 KW. |
| 220 | Re-shafting of rotor as per scope of workCategory-I CEP Motor325 KW. |
| 221 | Re-shafting of rotor as per scope of workCategory-II Mill Motor 450 KW. |
| 222 | Re-shafting of rotor as per scope of work Category-II FD Fan Motor 550 KW. |
| 223 | Re-shafting of rotor as per scope of work Category-III CW Motor 1500KW. |
| 224 | Re-shafting of rotor as per scope of work Category-III PA fan Motor 1650KW. |
| 225 | Re-shafting of rotor as per scope of workCategory-III ID fan Motor 1750KW. |
| 226 | Re-shafting of rotor as per scope of workCategory-IV BFP Motor 4600KW. |
| 227 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seatfor Category-I TAC Motor 220KW. |
| 228 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seatfor Category-I ACW Motor 250KW. |
| 229 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seat for Category-I BAHP Motor 280 KW. |
| 230 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seat forCategory-I CEP Motor325 KW. |
| 231 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seat forCategory-II Mill Motor 450 KW. |
| 232 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seatfor Category-II FD Fan Motor 550 KW. |
| 233 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seatfor Category-III CW Motor 1500KW. |
| 234 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seatfor Category-III PA fan Motor 1650KW. |
| 235 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seat forCategory-III ID fan Motor 1750KW. |
| 236 | To & fro transportation charges for rotor if it sent alone for balancing & or repair of bearing/coupling seatforCategory-IV BFP Motor 4600KW. |
| 237 | VARIOUS WORKS OF LT (0.4 KV) MOTORS:- |
| 238 | LT (0.4 KV) Motor Rewinding Works as per scope of work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole) |
| 239 | Repair of Rotor Shaft at Bearing Seat as per Scope of work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole). |
| 240 | Repair of Rotor Shaft at Coupling Seat as per Scope of Work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole) |
| 241 | Removing rotor shaft bend/ run out as per scope of work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole) |
| 242 | Dynamic Balancing of Rotor for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole). |