Repair / Maintenance Of Exhaust System, Fire Detection System And Other Misc Repair Of Manekeshw Centre Under Ge Utility Plant And Machinery Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Repair / Maintenance Of Exhaust System, Fire Detection System And Other Misc Repair Of Manekeshw Centre Under Ge Utility Plant And Machinery Delhi Cantt-10. Submission Date for this Tender is 28-10-2022. Flame Detectors Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

34271484
Corrigendum : Repair / Maintenance Of Exhaust System, Fire Detection System And Other Misc Repair Of Manekeshw Centre Under Ge Utility Plant And Machinery Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
28-10-2022

Tender Details

Repair / Maintenance Of Exhaust System, Fire Detection System And Other Misc Repair Of Manekeshw Centre Under Ge Utility Plant And Machinery Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 98480.0 /-
Tender Value
INR 49.24 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINTENANCE OF EXHAUST SYSTEM, FIRE DETECTION SYSTEM AND OTHER MISC REPAIR OF MANEKSHAW CENTREUNDER GE(U) P&M, DELHI CANTT -10.
Sl. No. Item Description
1Material and labour for de-scaling of condensers of central AC plantcapacity 3X270 TR by opening side plate, flushing the condenser tubes using de-scaling solution, Roding the condenser tubes carefully removing all the deposited materials completely and raising the solution through condenser tubes till clear water starts to come out from the condensers as complete including re-fixing the side plates by replacing gaskets & testing complete for satisfactory working at complete at Manekshaw Centre all as specified and directed by Engr-in-Charge. Notes :- (i)Necessary T&Psuch as pump, tube, descaling solution etc shall be arranged by the contractor without any extra cost to Department.(ii) Descalling of all condensers in one AC plant shall be considered as one job.
2Material and labourfor servicing of AHU unit including cleaning of bottom tray and cleaning of cooling coil complete with high pressure and coil shine solutionsand jet ofwater pressure with pump without damaging cooling coils and fins and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed for following capacity AHU:-
318000 CFM AHU
47000 CFM AHU
54000 CFM AHU
68000 CFM AHU
714000 CFM AHU
822000 CFM AHU
96000 CFM AHU
1013000 CFM AHU
1113500 CFM AHU
1211000 CFM AHU
13Material and labourfor servicing of ceiling mounted AHU unit including cleaning of bottom tray and cleaning of cooling coil complete with high pressure vaccum cleaner without damaging cooling coils and fins and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed for following capacity AHU:-
146000 CFMceiling mounted AHU
158000 CFMceiling mounted AHU
165000 CFMceiling mounted AHU
173000 CFMceiling mounted AHU
182000 CFMceiling mounted AHU
192500 CFMceiling mounted AHU
20Supply and fixing in repair of AHU Shaft bearing (02 Nos in each) of size for following capacityAHU as per site requirement complete all as specified and directed by Engineer-in-Charge. (Make - MTM/SKS or equivalent as approved by Accepting Officer.)
2118000 CFM AHU
227000 CFM AHU
234000 CFM AHU
248000 CFM AHU
2514000 CFM AHU
2622000 CFM AHU
276000 CFM AHU
2813000 CFM AHU
2913500 CFM AHU
3011000 CFM AHU
313000 CFMceiling mounted AHU
322500 CFMceiling mounted AHU
332000 CFMceiling mounted AHU
34Supply and topping up Refrigerator Gas R-134A complete all as specified & directed by Engr-in-Charge.(Make:- Mefron/ Floron/ Refron.)
35M &L for disamtling the one side puff panel of AHU and then diconnecting the chiller pipe and cooling coil of AHU of required andthen Supply and fixing in replacement of bottom tray for fan and coil section of AHU of any size and any capacity made out of SS sheet tray of grade 304 and also including 25mm thick thermocol insulation covered with tarfelt for AHU bottom complete all as specified and directed.
36Supply and fixing in replacement of shock absorbing rubber pads at the bottom of the AHU unit for absorbing shocks and vibrations, heavy duty of suitable size as per ground requirement complete all as speicifed and directed by Engr-in-charge.
37Supply and fixing in replacement of Pre filter 10 micron of size 610mm x 610x 50mm made of out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the AC Plant air handling unit complete all as speicifed and directed by Engr-in-charge. (Make- Thermodyne/ AAF or equivalent as approved by Accepting Officer.)
38ditto- all as per item No. 8.00 above but size 610mm x 300mm x 50mm.
39ditto- all as per item No. 8.00 above but size 300mm x 300mm x 50mm.
40ditto- all as per item No. 8.00 above but size500mm x 450mm x 50mm.
41ditto- all as per item No. 8.00 above but size 500mm x 500mm x 50mm.
42ditto- all as per item No. 8.00 above but size 500mm x 400mm x 50mm.
43S&F in repair bimetallic thermaloverload relay,9 to 15 Ampscomplete as specified and directed.
44S&F in repair bimetallic thermaloverload relay,14 to 23 Ampscomplete as specified and directed.
45S&F in repair bimetallic thermaloverload relay,20 to 33 Ampscomplete as specified and directed.
46S&F in repair bimetallic thermaloverload relay,24 to 40 Ampscomplete as specified and directed.
47Supply and fixing in replacement of Rubber Tyre Coupling (TC-14) set for chiller / condensor pump motor complete all as specified and directed by Engr-in-charge. (Make:- Unique or equivalent make as approved by Accepting Officer)
48Supply and fixing in replacement of Rubber Tyre Coupling (TC-13) set for chiller / condensor pump motor complete all as specified and directed by Engr-in-charge. (Make:- Unique or equivalent make as approved by Accepting Officer)
49Supply and fixing in replacement of Rubber Tyre Coupling (TC-11) set for chiller / condensor pump motor complete all as specified and directed by Engr-in-charge. (Make:- Unique or equivalent make as approved by Accepting Officer)
50Supply and fixing in replacement of multifunction electronic timer( 0 to 60 Sec) type Series 525 complete all as specified and directed by Engr-in-charge. (Make:- Siemens/L&T// ABB)
51Material and Labour for frame work with angle ironfor frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and asdirected by Engr-In-charge.
52Supply and fixing in replacement fully automatic star delta starter suitable for 3 phase, 415V,containing Electric over current protection relay range of suitable range with external CT 960 Amp, AC-3, 25 Amp rating contractor and back up protection HRC fuse of suitable rating motors of upto 30 HP Capacity including it is to be mounted on existing LT Panels of AC plants andconnections with suitable size single core copper conductor wire & brass terminals of 6 way including taking down old unsv one complete all as specified and directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/Crompton.)
53M&L for repairing /servicing Condenser or Chillerpump (Centrifugal pump) of following capacities by disconnecting the pump from motor, opening for inspection, replacing the worn out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing and commissioning including loading/unloading and transportation to & from authorised workshopcomplete all as specified and directed: -
54Condenser or Chiller Pump of capacity 30 HP
55Hotwater generator Pump of capacity 25 HP
56Disconnecting from mains/taking out existing unserviceable/defectivemotor of following capacity of any size, type, and make including disconnecting all electrical connectionsremoving from foundation transporting to repair workshop disconnecting unserviceable burn out winding completely including insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, transporting back to site, re-installating, testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
57Condenser or Chiller Pump of capacity 30 HP
58Hotwater generator Pump of capacity 25 HP
59M&Lfor repairing/ servicingAHU Fan Motor/ exhaust AHU of following capacity, opening themotor, cutting & removing old burnt windingwire, rewinding the motor with new super enamelled copper winding wire of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate,reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed :-
602 HP Motor
613 HP Motor
625 HP Motor
637.5 HP Motor
6410 HP Motor
6515 Hp Motor
66Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-32 includingNO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/ ABB/ C & S.)
67Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-25 includingNO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/ ABB/ C & S.)
68Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-18 includingNO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/ ABB/ C & S.)
69Supply and fixing in replacement Rigid UPVC piping of following dia complete with fittings, supports as perspecifications and duly insulated with 6mm thick closed cell nitrile rubber insulation.
7040mm dia
7132mm dia
72Supply and fixing in replacement over load relay 30-50 Amps complete all as specified and directed by Engr-in-Charge (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
73Supply & fixing in replacementbrass terminals of follwing ways complete all as specified and directed by Engr-in-Charge.
743 way
754 way
766 way
7710 way
78M&L for control wiring with 6 coreX 1.5 sqmm sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694complete all as specified and directed Make : Finloex/Havells/Polycab
79Supply & fixing in replacement single phasing preventer type VSP2 complete all as specified and directed by Engr-in-Charge.(Make:- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S.)
80M & L in replacement of unserviceable 3 way modulating motorized valve with Teflon gland, with linear movement actuator 24 V AC input supply, 0-10 V input signal with modulating thermostat & transformerof following sizes completeall as specified and directed.
8132mm dia
8265mm dia
8350 mm dia
8440 mm dia
8580 mm dia
86100 mm dia
87Supply and fixing in replacement Water temperature sensor suitable chiller units of 270 TR as per existing model and makecomplete all as specified and directed by Engineer-in-Charge.
88Supply and fixing in replacement Air Vent valves made out of brass of size 15mm dai for chiller chiller pipe line complete all as specified and directed by Engineer-in-Charge.
89Dismantling the old broken fan hub assembly including blades of cooling tower and replacement with new fan hub assembly with dry cast aluminium blades heavy duty as per existing size including U-clamps, nuts, bolts & washers suitable for cooling tower for 3 x 270 TRcapacity AC Plant complete all as specified and directed by Engineer-in-Charge.
90Disconnecting the defective FRP cooling tower of Cap 270 TR and repair the same by replacing defective broken/unserviceable spare parts including repair to minor leakages & assembling, testing & comminssioning for satisfactory performance complete all as specified & directed by Engr-in-Charge. Note:- (i) Required Spare parts shall be measured and paid seperatly as "Supply only" under item No. 40.01 to 40.09 . (ii) Labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit quoted rate.
91Supply only of following spare parts for FRP cooling tower complete all as specified & directed by Engr-in-Charge:-
92Eliminator
93PVC fins of size 600mm x 300mm x 165mm
94PVC Pipe 63 mm dia 3 Mtr long
95PVC End Cap 63 mm
96PVC Separator 63 mm dia
97PVC Socket
98PVC End cap 100 mm
99Nut Bolt any size
100FRP Compound Note for item No 40.01 to 40.09 :- (i) Materials of item Nos.40.01 to 40.09 to be incorporated in item No 39 here-in-before. (ii)Labour charge of item Nos.40.01 to 40.09 are deemed to be included in the quoted rate in item Nos. 39 here-in-before. (iii) Make of item Nos.40.01 to 40.09 as approved by Accepting officer.
101Supply and fixing in replacement cast iron Y strainer flenged ends with SS perforated sheet screen of following size complete all as specified and directed by the Engr-in-Charge.(Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
102100mm dia
103150mm dia
104200mm dia
10532mm dia
10665mm dia
10750 mm dia
10880 mm dia
109Supply and fixing in replacement cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of following size dai complete all as specified and directed by the Engr-in-Charge.(Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
110300 mm dia.
111200 mm dia.
112150 mm dia.
113125 mm dia.
114100 mm dia.
11580 mm dia.
11650 mm dia.
11765 mm dai
118Supply, Laying, jointing and testing of under electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge for the following:-
1194 core 10 Sqmm
1204 core 16 Sqmm
1214 core 25 Sqmm
1223.5 core 35 Sqmm
1233.5 core 50 Sqmm
1243.5 core 70 Sqmm
1253.5 core 95 Sqmm
126Supply and fixing in replacementmotorized spring return actuator for device with control panel and temprature sensor complete all as specified and directed.
127Supply , installation, testing and commission in replacement of fire dampers complete with smoke detector/ thermister linkage etc and actuator as required for operation complete all as specified and directed.
128Supply and fixing in replecement Acoustic treatment/ lining of area of AHUroom with 22G, GI channels of 50x50 mm size fitted at 600x600mm girds. These girids will be fitted with 50mm thick 32 kg/cum fiber glass insulation covered be fiber glas tissue and 24 G Al perforated sheet and as required . The joint shall be minimium overlapping of 75mm with 30mmx 3mmaluminium strip covering. All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and directed.
129M&L for control wiring with 4 coreX 4 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed. Make : Finloex/Havells/Polycab
130M&L for control wiring with 4 coreX 6sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 40 mm dia as per IS 694complete all as specified and directed Make : Finloex/Havells/Polycab
131M&L for control wiring with 2 coreX 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed. Make : Finloex/Havells/Polycab
132M&L for control wiring with 2 coreX 2.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed Make : Finloex/Havells/Polycab
133M & L For Providing,fixing, testing and commissioning in replacement of Duct mounted inline fans ofG.I. construction, complete with centrifugal fan with motor,canvas connection at inlet & outletcomplete as specified and directed of following capacity:- Make : Otsberg, ZECO, EDGEtech.
134600 CFM, 15 mmwg static pressure.
1351200 CFM, 15 mmwg static pressure.
1362000 CFM, 15 mmwg static pressure.
137Supply and fixing in replacement bakelite terminal plate of 6 way including brass studs, bolts and nuts etc suitable to match any make of 3 phase electric motors and capacity up to 30 HP complete all as specified and directed by Engr-in-Charge.
138Supply and fixing in replacement thermometer suitable for condenser water line with suitable housing for mounting on pipe line 0-50°C complete including taking down old unsv thermometer all as specified and directed by Engr-in-Charge.( Make :- Indfoss/ Renutrol).
139Supply and fixing in replacement Compound pressure gauge (Discharge pressure) of size 100 mm dia suitable for 0 to 300 PSI complete including taking down old unsv pressure gauge all as specified and directed by Engr-in-Charge. Make: Adarsh/Febic/ H guru
140S&F in repair Exhaust AHU Fan complete section with DIDW centrifugal curved fan, Fan selected for follwing CFM, FC type ,suitableas per existingmm Fan dia, RPM speed, Fan outlet velocity,kw shaft absorbing powerwith completedrive set & V-belt installedas per existing exhaust AHU with base frame and connected nutbolts and accessories all as per specified & directed by Eng-in-charge. FAN Make:- Kruger/nicotra
141Upto 4000 CFM
142Upto 10000 CFM
143Supply and fixing in replacement indicator lamp assembly complete LED type suitable for the existing system supply voltage 230V / 440V ACcomplete all as specified and directed by Engr-in-Charge. (Make:- MIMIC CONTROL/ GE CONTROLS / RR MICRO / L&T / SIEMENS/ BCH/ SCHNEIDER)
144Supply and topping up Compressor Oil RL-170 H complete all as specified & directed by Engr-in-Charge. (Make:- HPCL(Seetal)/ HP (Seetal)/ Servo.)
145Material and labourfor servicing of Exhaust AHU of capacity up to 10000 CFM including cleaning of bottom tray and with air pressure to sweep up all the particles andchecking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed and specified by engineer in charge.
146Supply and fix in replacementGalvanised iron strip 32X6 mm as earth continuity conductor including fixing arrangement on suitable size insulator complete all as directed.
147M&L earthing complete with GI plate electrode of size 600 x 600 x 6 mm thick bured directly in ground vertically at a depth not less 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 1.5 cm thick packed layer of charcoal of dust and common salt filling in alternate layers and making electrode connection by using GI strip of size 32X6 (up to 7 meter GI strip included) mm by means of bolts nuts check nuts and washers made of brass and earth strip protected by light grade 40 mm dia GI Pipe upto test point and connected to main switch board are main controlled board with provision of GI pipe medium grade 20mm bore for watering including funnel wire mass RCC pit cover and PCC Chamber pit with 1:2: 4 type C2 (including excavation earth work) all as specified and shown on plate No 5 of SSR Part-1.
148Supply, install, testing and commissioning in replacementof Duct insulation with 25mm thick Nitrile Rubber insulation of class "o" fire retardantwithMechanicalprotection over insulation with fiber glass cloth & UV paint (for exposedduct) for Ducts installed outside, (exposed to sunlight) complete all as specified and directed by the Engineer-in-charge.
149Supply and fixing in repair MCB TP 63 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed by Engr-in-Charge (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
150Supply and fixing in repair MCB TP 40 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed by Engr-in-Charge (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
151M&L for preparation of surfaces of Cenral AC Plant of capacity 3 x 270 TR at Manekshaw Centre for painting of trap door, condensers,chillers,compresors, Induction motors, pumps, hot water boiler, C channels, all pipe lines, valves and outer body of cooling towers and AHU"s with different colors following the color code system as directed by the site-in-charge.Job includes removing the old paint by rubbing, brushing and applying one coat of red oxide zinc chrome primer and two coats of Synthetic Enamel Paint (1st grade quality) complete all as specified and directed by the Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
152Supply & fixing MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
153Supply & fixing MCCB 4 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
154Supply & fixing MCCB 3 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
155Supply & fixing MCCB 3 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
156Supply & fixing MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
157Supply & fixing MCCB 3 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
158Supply & fixing MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
159Supply & fixingMCCB 3 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
160Supply & fixing MCCB 3 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
161Supply & fixing MCCB 3 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
162Supply and fixing in replacement V-belt of size SPA-1120 complete all as specified and directed by Engr-in-Charge. (Make - Feener or equivalent as approved by Accepting Officer.)
163ditto- all as per item No. 75.00 above but size SPA-1750
164ditto- all as per item No. 75.00 above but size SPA-1850
165ditto- all as per item No. 75.00 above but size A-1610
166ditto- all as per item No. 75.00 above but size SPA-1800
167ditto- all as per item No. 75.00 above but size B-2350
168ditto- all as per item No. 75.00 above but size A-1630
169ditto- all as per item No. 75.00 above but size SPB-1320
170ditto- all as per item No. 75.00 above but size SPA-1550
171ditto- all as per item No. 75.00 above but size A-2270
172ditto- all as per item No. 75.00 above but size SPA-900
173M & L for replacement ofchilled water or refrigerent MS class "C" pipe insulation inside the building but excluding valves/strainers/pr gauges etc and adequately supported on rigid supports and duly insulated withclosed cell elastometric nitrile rubber of class "O" insulation and insulation applied by adhesive confirming to standard OEM specifications secured with 0.63 mmGI sheet cladding complete at the joints and repairing of damage to the buildings if any etc as per specifications and as required complete in all respects.The size of pipes and insulation shall be as shown below:-
17450 mm Pipe (32mm thick insulation)
17565 mm Pipe (32mm thick insulation)
17680 mm Pipe (40mm thick insulation)
177100 mm Pipe (40mm thick insulation)
178125 mm Pipe (40mm thick insulation)
179150 mm Pipe (40mm thick insulation)
180200 mm Pipe (40mm thick insulation)
181250 mm Pipe (40mm thick insulation)
182Supply and fixing in replacement 80 mm dia cast iron non return valves of pressure class PN 1.6 including nuts, bolts, washers, gaskets, etc for Central type AC plants complete all as specifed and directed by Engineer-in-Charge.(Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
183ditto- all as per item No. 87.00 above but 100mm dia
184ditto- all as per item No. 87.00 above but 150mm dia.
185Ditto- all as per item No. 87.00 above but 250mm dia.
186Supply, Installation , Testing and commissioning in repair of perfabricated type cable tray of size 45mm wide x 50mm x 1.6mm fabricated out of perforated hot dip galvanized sheet of minimum 1.6mm thick with 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed.
187All as per Item No.91.00 above but of size75mm wide x50mm x 1.6mm complete all as specified and as directed.
188All as per Item No.92.00 above but of size150mm wide x50mm x 1.6mm complete all as specified and as directed.
189S&F in replacement of outer body casing panels Factory made Double skin ofExhaust Air Handling unit as specifications as under:-.The front side of AHU panel dimension having casing panels shall be made of sandwich construction of at least 25 mm thick injected with CFC free R141b blended Poly Urethene foam insulation having density of 38-40 Kg/Cu.m and thermal conductivity of 0.02 W/m-deg K. The Casing panels(inside and outside) shall be constructed of 1.2 mm steel sheetcoated with 220 gm/Sq.m galvanized Zinc(Zn) and 3% Chromate.The outer skin shall be 0.6 mm and inner skin 0.6 mm . Material of frame shall beSelf supporting extruded aluminium with thermal break of AHU. The panels are removable type and are fixed to the frame with self tapping screws. Labyrinth type gasket sealing between panel and frame be provided to eliminate air leakages. The front side of AHU panel unit shall be supported on full perimeter base frame constructed from heavy duty galvanized steel sheetwith complete all fittings as per site required as directed and specified by Eng-in-Charge.
190All as per item no. 94.00 but frame work of filters (back side)all fittingsas per specified & directed by Eng-in charge
191All as per item no.94.00 but for side panel (left/ Right) (widthXheight).
192All as per item no.94.00 but for side panel (left/ Right) (widthXheight) with the AHU door opening shall be interlocked with micro switch ( AHU motor is trip when door is open)directed&specified by Eng-in-charge.
193All as per item no.94.00 but for panel (top side) (lengthXwidth) and all fittings with space for top duct as per existing, directed&specified by Eng-in-charge.
194All as per item no.94.00 but fforpanel (bottom side) (lengthXwidth) directed&specified by Eng-in-charge. NOTE:-The exhaust AHU shall be suitable for conventional floor Landing(with vibration pads)with all accessories and controls for AHU (Antivibration with spring mechanisim set of four)
195M&L for Supply, fixing of powder coated extruded aluminum rectangular diffusers complete with black anodized extruded aluminum VCD (wherever specified), nuts, bolts, screws etc.complete as required at site all as specified and directed by engineer-in-charge.
196(a) Supply air diffusers of required sizes with volume control damper.
197(b) Return air diffusers of required sizes without volume control damper
198M&L for Supply & Fixingofpowder coated extruded aluminum supply & return grilles complete with nuts, bolts, screws etc. to make the system complete, as required at site all as specified and directed by engineer-in-charge.
199M&L for Supply and installation in replacement of thermal insulation material for non-exposed Ducts with closed cell class o nitrile rubber elastomeric insulation of density 40-60 Kg/m3 thermal conductivity of 0.033-0.038 W/mk and µ>=7000 (k-flex st) to be applied on ducts using manufacturers recommended rubber based adhesive as per the approved specification the material shall be from global approved complete all as specified and directed by engineer-in-charge.
200(a) 19 mm thick
201(b) 25 mm thick
202M&L for Supply, installation, testing and commissioning in replacement of flexible fire retardant canvas connector cloth including flanged from both side with inspection chain in it removing of old one complete all as specified and directed by Engineer-in-charge.
203Supplyand fixing in replacementrubber mat LT 1.1KV volt grade 1mtrx 2mtr x 10mm
204Supply & fixing PVC insulated single core copper conductor cable of size 16 sqmm for connections in LT Panels including copper thimbles including taking down old unserviceable onecomplete all as specified and directed by Engineer-in-Charge.(Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.)
205Supply & fixing PVC insulated single core copper conductor cable of size 25 sqmm for connections in LT Panels including copper thimbles including taking down old unserviceable onecomplete all as specified and directed by Engineer-in-Charge.(Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.)
206Supply & fixing in replacement aluminium lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed by Engineer-in-charge.
207Supply & fixing in replacement aluminium lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed by Engineer-in-charge.
208Supply & fixing in replacement aluminium lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed by Engineer-in-charge.
209Supply & fixing in replacement aluminium lugs for cable of cross sectional area 35 Sqmm complete all as specified and directed by Engineer-in-charge.
210Supply & fixing in replacement aluminium lugs for cable of cross sectional area 75 Sqmm complete all as specified and directed by Engineer-in-charge.
211Supply & fixing in replacement aluminium lugs for cable of cross sectional area 95 Sqmm complete all as specified and directed by Engineer-in-charge.
212Supply & fixing in replacement aluminium lugs for cable of cross sectional area 120 Sqmm complete all as specified and directed by Engineer-in-charge.
213Supply & fixing in replacement copper lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed by Engineer-in-charge.
214Supply & fixing in replacement copper lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed by Engineer-in-charge.
215Supply & fixing in replacement copper lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed by Engineer-in-charge.
216Material and labour for maintenance of AHU supply panel / feeder pillar/LT panel indoor/outdoor type including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends fresh and supply and crimping new thimbles/lugs and fixing the cable on bus bar/MCCB/Main switch/MCB including providing new nut bolts and washer if required greasing the doors of feeder pillar/LT panel outdoor/indoor type complete all as specified & directed by Engr-in-Charge.
217Attending complaint of control panel wiring and making it fully serviceable with and including PVC tape, PVC tie, Nut bolt, and other items complete all as specified and directed. Notes: - After intimation ofbreakdownby Engineer in Charge/JE E&M through telephone or verbally, the contractor shall arrange theMechanic to attend the complaint within 2 hours and make the plant functional.If contractor failed to attend complaint with in time frame, a penalty of Rs 400/- per Hrs per complaint shall imposed on contractor and shall be recovered from contractor"s dues
218Cleaning of inside surface of supply ducts of HVAC (minimum open area of duct 1.00Sqm and maximum area 16.00Sqm) system of any area using high power vacuum air compressor robotic camera, air hammer, special nozzles, air sweep with other required accessories given/showing inspection of dust before and after cleaning of duct using colour video inspection complete all as specified & asdirected by Engineer-in-Charge.
219M & L for servicing of LT ACB 1600 Amps, 1200 Amps or 600 Amps draw out type 415 volts, 50 Hz, brushing, greasing and tightening of nuts and bolts fixed and movingcontacts for smooth functioning and replacing of minor accessories complete all as specified and directed by the Engr-in-Charge.
220M&L for disconnecting & opening of all parts of Package type Air Washer of capacity 7200 CFM installed at the roof top of Manekshaw Centre and servicing,repairing & Overhauling for satisfactory working condition complete including Motor , Blowers , Pumps Fill pad Aluminium chasing etc.And refixing the same after servicing and testing complete including replacement of the following parts:-
221Blower unit
222Motorof capacity 5 HP, 1440 RPM
223Pump 1/4 HP
224Fill Pad 200 mm thick
225Double Skin
226Aluminium Chasing
227Filter Wire Mesh
228Water Tank SS 304 Note for item No 121.01 to 121.08 :- (i) Materials of item Nos.121.01 to 121.08 to be incorporated in item No 121.00 here-in-before. (ii)Labour charge of item Nos.121.01 to 122.08 are deemed to be included in the quoted rate in item Nos. 121.00 here-in-before. (iii) Make of item Nos.121.01 to 121.08 as approved by Accepting officer.
229M & L in repair of site fabricated GSS Sheet metal, rectangular/round ducting complete with neoprene rubber gaskets,elbows,splitter damper vanes,hangars,supports as per approved drawings and specifications of following sheet thickness complete
2300.63 mm thickness sheet (24 gauge)
2310.80 mm thickness sheet(22 gauge)
232Inspection, checking, cleaning, testing and commissioning of fire alarm cum fire detection system complete including fire detectors, smoke detectors, heat detectors, response indicators, wiring etc. through trained/experianced technician of OEM, the system and carry out planned maintenance in systematic and controlled manner at Manekshaw centre building complete except new server room all as specified and directed by Engineer-in-charge.
233Notes for Serial item No. 123.00 (a) Fire Alarm control panel:- These shall be kept clean by checking for its controls, indicating equipment’s system and all operations/fault indicators including checking of panel circuits for its healthiness and including of healthy battery/UPS/battery charger system. (b) Smoke Detectors &Fire Detectors: - All smoke/fire detectors shall be removing dust/dirt accumulated on them due to local ambient conditions. These shall be tested & cleaned once in a quarterly and report shall be maintained as directed by Engineer-in-Charge duly signed by user and concerned JE/Engineer-in-charge. (c)Response Indicators, Manual Call Point and Hooter:All items which are installed inside a cabin, room or above ceiling shall be tested by actuating the particular detectors every quarterly so as to ensure proper functioning of indicator. (d) Wiring and cables:Complete wiring shall be inspected jointly by contractor, MES rep and users so that structure or occupancy changes doesn"t damage the cable/wiring/trigger device (Manual call points smoke heat ionization detector etc) (e)During attending complaint and quarterly maintenance check any spares/items required forreplacemnet will done by the technician of OEM (i.e detectors, panels, response indicators, hooters wiring, battery) (f) Quarterly maintenance schedule submit by the contracor to the Engineer-in-Charge for his approval before going to the quarterly check.
234(g) Deployed Technician/mechanic fully equiped with necessary tools and plants are deemed to be included in the quoted rate. (h) Arrangement of testing equipment provided by the contractor deemed to be included in quoted rates. (i) The mechanic shall also be in possesion of mobile and two wheeler for communication and mobility. (j) The contractor deemed to have visited the site and seen the scope of work before quoting the rates. (l) Quarterly inspection test report will be submitted to deptt duly signed by user/ Engr-in-Charge. (m) Mock drill will be conducted once in quarterlyin presence of user after completion of cleaning and testing. (n) Adequate manpower shall be deployed at site to carried out for quarterly maintenance check as per CA provision. (o) All the work mentioned in notes above are deemed to be included in the quoted rates. (p) The rates for making necessary arrangement of scaffaolding/ ladders is deemed to be included in the quoted rates. (q) Any damage to smoke and fire detection system during maintenance shall be repaired by the contractor at his own cost.
235Checking and attending day to day complaints by means of finding the faultsonlyrelated to fire alarm, detectors, hooters, response indicators, wiring and all other accessories and fixtures maintained by the department complete all as specified and directed. NOTE :- (i) The rate of this item are included for attending of complaints only. (ii) Taking down of unserviceable materials and fixing of new materials will be measured and paid seperately under relevent items as mentioned in Section-IV here-in-after. (iii) Complaints shall be attend any time from user/MES rep without fail, failing which recovery of rate Rs 1000/- per complaint shall be effected from the RARs/FB. (iv) Minor materials such as PVC wire of any size as per requirement upto 1.0 mtr length, thimble, electric tape, fixing accessories, etc shall be deemed to be included in the quoted rate of this itmes. (v) The complaints shall be attend and defects shall be rectified within 08 Hrs commencing from date and time of notifing the complaint, failing which a penauly Rs 1000/ per complaint shall be leived/imposed on the contractor and recovery shall be made from his dues. (vi) Contractor shall be arrange suitable T&P incl necessary ladder and scaffolding for approach and safety measures to make it functional complete all as specified and directed. The rates for which are deemed to be included in the quoted rate.
236Supply and fixing of Multi Detector, optical type low current draw, wide operating voltage 8 to 30 VDC, Bi-colour LED detector status indicator, Automatic drift compensation, tested and approved to EN54 - 7:2000 (Amendment 1)including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: APPOLO / EDWARD / SEIMENS/HONEYWELL).
237Supply and fixing of response indicators with MS Box 16 SWG and plastic coverincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: APPOLO / EDWARD / SEIMENS/AGNI).
238Supply and fixing of maintanance free battery 7 AH, 12 Volts with 8 Hours backup and 12 months warrantyincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make:- EXIDE/ AMARON/ STANDARD FURKKAVA)
239Supply and fixing of PVC conduit pipe medium grade size of 25mmincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make- Kalinga/ Polycab/Finolex/ Havells/ Anchor).
240Supply and fixing of multi-stranded copper conductor cable 1.5 Sq. mm nominal cross-sectional area, two core, PVC insulated and unsheathedFRLSH cable 1100 volts grade for sub main wiringincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make- Havells/Polycab/Finolex/ RR Kabel)
241Supply, fixing, commissioning and testing of Microprocessor based 6 loop capacity , Networkable analogue addressable type fire alarm control panel with 640 character LCD display. The panel shall be equipped with sufficient numbers of loop with 20% spare capacity with each loop shall have a capacity of minimum 159 detectors and 159 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as requiredincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge.(UL 9th Edition Approved) (Make - NOTIFIER/CPU2-3030D/WITH 6 LOOP/WITH NCM-W)
242Material and labour for rectification, maintenance of addressable zones, searching the faults, up/down loading software of main control panel at Manekshaw center and reprogramming entire system and testing by authorized Technical Engineer of OEM complete all as directed by Engr-in-charge. and including Inspection, testing and commissioning of complete fire alarm system installed done by authrized OEM of Honywell manufacturer only all as required complete all as specified and directed by Engineer-in-charge.
243Supply, fixing, commissioning and testing of automatic Floating Sensitivity type Analog addressable Acclimate Photo thermal smoke detector with mounting based LED, Address Switch from 01-159 , to programme the detectors, complete as required. (In Changing Environment Area) ul- 7th editionincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
244Supply, fixing, commissioning and testing of analog addressable Rate of Rise Cum Fixed temperature detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Ul- 7th editionincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
245Supply,fixing,testing and commissioning of addressable type fault for isolating module shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model)including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER GST/APPOLO/ EDWARD/HONYWELL).
246Supply and fixing of addressable control modules for Hooters / Sounders / Strobes etc. including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make : - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
247Supply and fixing of Strobe Lights Cum Hooter with 110 cd. The strobes shall be synchronized for better evacuationincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make:- NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
248Supply and fixing of manual call pointincluding taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
249Supply and fixing in replacement oflinear BEAM type smoke detectorconsistingof a combined transceiver unit and an accompanying reflector which is to be fitted with all technical specifications as under :-
Disclaimer :