| 1 | Dismantling the existing damaged cubical brick work clearing away and carefully taking material useful for reuse for any thickness of concrete including all cost etc. as per standard specification. |
| 2 | Dismantling the existing damaged reinforced cement concrete portion clearing away and carefully taking material useful for reuse for any thickness of concrete including all cost etc. as per standard specification. |
| 3 | Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc complete complying with SS20B. TNDSS No:23&24 |
| 4 | Cement concrete of mix 1:4:8 (one part of cement four part of sand and eight part of aggregates) using 40 mm gauge machine broken granite stone jelly for foundation including de watering if found necessary and laid in layers of not more than 15 cm thick well rammed and consolidated etc complying with standard specification. TNDSS No:28 |
| 5 | Random rubble masonry in cement mortar 1:5 mix (one part of cement and five part of sand) using new best rough and bond stones from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc complete complying with standard specifications. |
| 6 | Supplying and erecting centering to sides and soffits including supports and strutting with necessary centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86. |
| 7 | Supplying, fabricating and placing in position of Steel Reinforcement using Mild steel or ribbed tar steel rods, for all RCC works as per the design given by the departmental officers including cost of steel cutting, bending, placing in position and binding with binding wire and all labour charges for cutting, bending, tying and placing in position etc, complete. TNDSS No:97 |
| 8 | Brickworkin cementmortar1:5 (one part of cement five part of sand) mix using country bricks of size 8¾\"x4¼\"x2¾\" includingcuring, cost and conveyance of all materials to siteand all labour charges etccompleteas per standard specification. |
| 9 | Reinforcement Cement concrete 1:1½:3 (one part of cement one and a half part of sand and three part of aggregates) using machine broken granite jelly of 20 mm size for all reinforced cement concrete works excluding cost of centering shuttering strutting and also cost of reinforcement grill in position but including laying vibrating with mechanical vibrators using finishing etc complete, as directed by the departmental officers etc complete complying with standard specification. TNDSS No:30 |
| 10 | Solid PVC door shutters using 19 gauge 19 mm MS square tubes for styles and outer frames. 15 mm MS square tubes for top lock and bottom rails. The steel tubes shall be covered with 5 mm thick solid PVC sheets. Shutter using 5 mm thick solid PVC sheets for paneling shall rigidly fixed in position including necessary furniture and fittings. |
| 11 | Supply and fixing in position best quality of approved make Indian Water closetof size 580 x 440 mm with all accessories such as \"P\" trap or \"S\" trap confirming to IS 2556 part XII with sand cusion and forming flooring alround the closet using 40 mm leveling course 1:4:8 - 100 mm thick and finishing the top to the required slope and including necessary internal connection and outlet connection and making the disturbed potion to original condition without leakage etc including Labour charges for fixing etc complete. |
| 12 | Dadooing the walls with plain glazed tiles of 150 x 150 x 6 mm set in cement mortar 1:2 (one part of cement two part of sand) 12 mm and pointing white cement used 4kg/m2 neatly etc complete as directed. |
| 13 | Paving floor with vitrified tiles (marbonite) in all floors over the base layer of cement mortar 1:3 (one par of cement three part of sand) 20 mm thick pointed with white cement at 0/40 kg/m2 including finishing the joints etc complete, as directed by the departmental officers (The rate should be exclusive of cost of flooring concrete 1:5) special. |
| 14 | Supplying and delivery of following PVC / GI pipes and specials65 mm GI pipe |
| 15 | 25 mm U PVC pipe |
| 16 | 32 mm GM gate valve |
| 17 | 25 mm PVC bend |
| 18 | 25 mm PVC coupling |
| 19 | 110 mm PVC door elbow |
| 20 | 15 mm PVC screw down tap |
| 21 | 110 mm PVC pipe |
| 22 | 110 mm PVC elbow |
| 23 | 110 mm PVC bend |
| 24 | 110 mm PVC tee |
| 25 | 1000 Litre HDPE tank |
| 26 | Supplying and fixingof trusses using necessary \"L\" angles and \"I\" sections each according design approved by the departmental officers including cutting, welding, cost and conveyance of all materials to work site and all labour charges etc as per standard specifications. |
| 27 | Supplying and fixing of roofing with galvaline Sheet 0.60 mm thick of approved quality by drilling hole (and not by punching) with necessary J/U bold and nut of 8 mm Ø of suitable length providing one set of bitumen washer at 25 mm Ø and 1.60 mm thick for each bold and nut including protruding portion of bold and nut shall be covered with bitumen compound etc complete complying with standard specification and as directed by Engineer incharge. TNBP NO.49. |
| 28 | Plastering walls with cement mortar 1:4 (one part of cement four part of sand) 12 mm thick including all cost and conveyance of all materials and all labour charges etc. complete as per standard specification. |
| 29 | Painting the new walls two coats over one coat of priming with best cement paint of approved colour and quality including preparation of surface and finishing neatly etc., complete complying with standard specification and as directed by the department officers. |
| 30 | Cement concrete 1:2:4 (one part of cement two part of sand and four part of aggregates) using machine broken granite jelly of 20 mm size for all cement concrete works excluding cost of centering shuttering strutting and also cost of reinforcement grill in position but including laying vibrating with mechanical vibrators using finishing etc complete, as directed by the departmental officers etc complete complying with standard specification. |
| 31 | Supply and fixing of TNEB Meter Board suitable for 32A Three Phase service connection with 3 Nos. 32A Fuse unit (500V), 32A Neutral link and earth link (1inch x 1/8inch Copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1inch thick on either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and interconnection with 7/20 PVC insulated copper wire from EB meter to fuse unit.SD 127. |
| 32 | Supply and run of 4 of 4 Sq.mm (56/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade on 7/20 GI bearer wire for service connection mains SD 67. |
| 33 | Supply and run of 2 of 6 Sq.mm (84/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 25mm Ø GI pipe (Class \"B\") bent at both ends with necessary angle iron up right and end supports for mains SD 71. |
| 34 | Wiring with 2 x 1.5 Sq.mm (22/0.3) PVC insulated unsheathed single core copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch in flush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point for electronic regulator. (Assume 5 Points Per Coil) (SD-22) |
| 35 | Wiring with 2 x 4 Sq.mm (56/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 15A 3 pin non interlocking FT wall socket and 15A FT switch with painting of suitable colour with continuous earthwire connection of 14 SWG TC wire for open power plug point. (SD-13) |
| 36 | Wiring with 2x 1.5sq.mm (22/0.3) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mmx 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open plug point. (SD-10) |
| 37 | Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K. Lite) suitable for 11W CFL lamp with CFL SD 83. |
| 38 | Supply and fixing of TNEB Meter Board suitable for 32A Single Phase service connection with 32A Fuse unit (500V), 32A Neutral link and earth link (1inch x 1/8inch Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1inch thick on either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and interconnection with 7/20 PVC insulated copper wire from EB meter to fuse unit SD 125. |
| 39 | Supply and fixing of 32 Amps DP Switch of 500 V with Metal clad with fuse and neutral (Side Handle) on suitable TW Board , with earth connection only SD 144. |