Construction Of Girls Hostel Funded By Aicte Under Cafes Ner Scheme 2021-22 At Gauhati University, Kamrup Metro-Assam

University Gauhati University-UGU has published Construction Of Girls Hostel Funded By Aicte Under Cafes Ner Scheme 2021-22 At Gauhati University. Submission Date for this Tender is 20-10-2022. Building Work Tenders in Kamrup Metro Assam. Bidders can get complete Tender details and download the document.




Tender Notice

34178569
Construction Of Girls Hostel Funded By Aicte Under Cafes Ner Scheme 2021-22 At Gauhati University
Open Tender
Indian
Assam
Kamrup Metro
20-10-2022

Tender Details

Construction Of Girls Hostel Funded By Aicte Under Cafes Ner Scheme 2021-22 At Gauhati University

Key Value

Document Fees
INR 6000 /-
EMD
INR 598476.0 /-
Tender Value
INR 2.99 Crore /-

BOQ Items

Name of Work: Construction of Girls’ Hostel funded by AICTE under CAFES(NER) Scheme-2021-22 at Gauhati University
Sl. No. Item Description
1CIVIL WORK
2EARTH WORK Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
3Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sq.m. on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto1.5m, as directed by Engineer-in-charge. All kinds of soil.
4Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m.
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
6ANTI-TERMITE TREATMENT Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos / Lindane emulsifiable concentrate of 20%
7Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
8CONCRETE WORK CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size).
91:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20mm nominal size).
101:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
11DAMP-PROOF COURSE Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
12Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
13MISCELLANEOUS Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling, dressing & finishing the top smooth.
14REINFORCED CEMENT CONCRETE CAST IN SITU Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
15FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
16Walls (any thickness) including attached pilasters, butteressess, plinth and string courses etc.
17Suspended floors, roofs, landings, balconies and access platform
18Lintels, beams, plinth beams, girders, bressumers and cantilevers.
19Columns, pillars, piers, abutments, posts and struts.
20Stairs, (excluding landings) except spiral-staircases
21Extra for shuttering in circular work (20% of respective centering and shuttering items)
22Weather shade, Chajjas, corbels etc., including edges
23STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
24Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
25DESIGN MIX CONCRETE Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admoxtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. "(Note :- Cement content considered in this item is @330 kg/cum. "Excess/ less cement used as per design mix is payable/ recoverable separately). All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum
26All works above plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum
27BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:4 (1 cement : 4 coarse sand).
28Cement Mortar 1:6 (1 cement : 6 coarse sand).
29Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
30Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand).
31Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. (a). Brick on flat soling.
32CLADDING WORK Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm
33Granite of any colour and shade Area of slab over 0.50 sqm.
34Providing edge moulding to 18mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Marble work
35Granite Work
36Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
37WOOD AND P.V.C. WORK Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 12 mm thick
3818 mm thick
39Providing and fixing ISI marked flush door shutters conforming to IS:2202(Part-I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35mm thick including ISI marked Stainless Steel butt hinges with necessary screw.
40Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete : 25 mm dia
41M.S. GRILL Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flates, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
42BRASS FITTINGS Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm
43Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 40 mm
44Providing and fixing bright finished brass handles with screws etc. complete: 125 mm
4575 mm
46ALUMINIUM FITTINGS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
47Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type)
48Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
49Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
50Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
51STEEL WORK Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge Profile B Fixing with adjustable lugs with split end tail to each jamb.
52Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
53Providing and fixing circular/ hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140mm, 73mm height, top lid of 1,5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M,S, sheet box by means of 3.3mm dia round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standared drawing.
54SS RAILING Providing and fixing stainless steel (Grade304) railing made of hollow tubes, channels, plated etc., including welding, grinding, buffing, polishing and making curvature (whereever required) and fitting the same with necessary stainless steel nuts and bolts complets, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
55FLOORING Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement
56Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt / Antiskid finish of size Size of Tile 600x600 mm
57Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm
58ROOFING Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm center to centre, one flange fixed to the ceilling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200mm center to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 459mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm dia x 230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mmc/c, including jointing and finishing to a flush finish of tapered (Contd....)
59and square edge of the board with recomended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-in-charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
60ROOFING SHEET & ACCESSORIES Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
61Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
62Barge board (Upto 300 mm)
63FINISHING CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
6415 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 fine sand)
65CEMENT PLASTER (IN COARSE SAND) 15mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement : 4 coarse sand)
66Neat cement punning.
67PLAIN CEMENT MORTAR BANDS 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand): Raised Band
68POINTING ON BRICK WORK Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing
69FINISHING EXTERIOR FINISHING Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
70WALL PUTTY Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
71INTERIOR FINISHING Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
72Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
73Applying priming coat: STEEL & WOODEN SURFACE With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
74With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
75Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
76DRAINAGE Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
77ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, buttoms and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
78For shutters of doors, windows & ventilators including providing and fixing hings/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
79Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
80WATER PROOFING Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
81Providing and applying intehral crystalline slurry of hydrophillic in nature for water proofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducingpermeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat.
82For horizontal surface one coat @ 1.10 kg per sqm.
83PLUMBING & SANITARY WORKS
84INTERNAL PLUMBING WORKS : SANITARY FIXTURES INDIAN TYPE WATER CLOSET (WC) Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
85EUROPEAN TYPE WATER CLOSET (WC) Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
86WASH BASIN Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
87KITCHEN SINK (STAINLESS STEEL) Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mm
88FITTINGS & ACCESSORIES MIRROR Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
89SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER ANDLIQUID SOAP CONTAINER Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
90Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
91TOWEL RAIL,TOWEL RACK & TOWEL RING Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm,78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
92ROBE HOOK Providing and fixing bright finished brass hard drawn hooks and eyes 300 mm
93TOILET PAPER HOLDER Providing and fixing toilet paper holder : C.P. brass
94Providing and fixing P.V.C. WC connector (straight or bend type) with rubberlip ring. Including 110 mmdiaPVC pipe / bend of requiredlengthandproper connection with M seal to C.I. pipe complete as required
95WASTE COUPLING Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
96BOTTLE TRAP Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
97BIB COCK Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
98Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
99STOP COCK / ANGULAR VALVE Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
100HEALTH FAUCET Providing, fixing, testing and commissioning of CP Brass Health Faucet with nuts, washers of approved brand including cutting and making good the walls wherever required. Rate of flow should be 4 LPM
101Providing and fixing Floor trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
102Providing and fixing medium duty CP Floor grating with frame of approved design brand including setting in floor with cement motor to match with floor finish as per architect requirement including cutting and making good floor or wall wherever required. a) 110mm dia
103Providing and fixing medium dutyCI grating (for RWP) with frame of approved design brand including setting in floor with cement motor to match with floor finish as per architect requirement including cutting and making good floor or wall wherever required. a) 110mm dia
104PILLAR COCK & SINK COCK Providing & fixing, testing and commissioning of counter mounted C.P. brass pillar cock with aerator for wash basins of approved brand.
105Providing & fixing, testing and commissioning of wall mounted C.P. brass Sink cock of approved brand including cutting and making good the wall/floor wherever required.
106SHOWER Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. a) 15 mm nominal dia
107Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
108Providing and fixing C.P. brass stop cock (concealed) of standard 15 mm nominal bore
109SOIL, WASTE & VENT PIPES Providing, fixing, testing and commissioning of uPVC SWR pipe confirming to IS-13592, Type-B cut to required lengths including all necessary fittings and special such as bends, junctions offset, access pieces (plain or door), Tees, bends, reducers, flanges, plugs unions and clamps Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly epoxy coated including chasing, cutting and making good the walls / floor etc. whereverrequired a)110 mmO.D type "B"
110Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
11140 mm dia
112Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming ro IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diameter.
113Providing and fixing wall faced unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving10mm gap for thermal expansion. Bend 87.5° 110mm bend.
114Shoe (Plain) 110mm Shoe.
115Providing and fixing unplasticised PVC pipe clip of approved design to unplasticised PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required lingth, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm.
116Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams.
117Providing and fixing uPVC cowl complete including cutting and making good the walls and floors wherever required. a) 110 OD
118Providing & fixing M.S. structural work fabricated from standard section e.g. M.S rounds, angles, channels, plates including cutting to size,drilling,welding fixing and welding to insert plates in RCC structural members as directed by engineer-in-charge including cutting and making good the walls, ceilings and floors (for pipe supports, clamps etc.)
119WATER SUPPLY PIPING Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK , Including cutting chases and making good the walls 15 mm dia Pipes
12020 mm dia Pipes
12125 mm dia Pipes
12232 mm dia Pipes
123ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Domestic & Flushing water supply pipes from OHT, in shaft,terrace, internal pipes in ceiling and concealed in wall, etc) EXTERNAL WORK 40 mm dia Pipes
12450 mm dia Pipes
12565 mm dia Pipes
126Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore.
12740 mm nominal bore.
12850 mm nominal bore.
129OVERHEAD WATER TANK Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
130EXTERNAL PLUMBING WORKS : Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
131Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
132ELECTRICAL WORK
133SUB HEAD : A - WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
134Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
135Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
136Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1372 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1382 X 6 sq. mm + 1 X 6 sq. mm earth wire
1394x6 sq.mm + 2x6 sq.mm earth wire
1404x10 sq.mm + 2x6 sq.mm earth wire
141Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 2 pair
142Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
143Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
144Bell push
145Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
146Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
147Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
1483 Module (100mmX75mm)
149Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
150Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
151Installation, tesitng and commissioning of pre-wired fluorescent fitting/compact fluorescent fitting of all types , complete with all accessories and tube etc. directly on ceiling/wall, including connection witn 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
152Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
153Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
154Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
155Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel / PVC conduit as required. 1 run of cable
156Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
157Supplying and fixing of Krone telephone tag blocks, of the following capacities including termination of paired wires, in 2mm thick M.S. box with hinged metal cover duly painted and labelled as required. 10 pair Tag Box (with 1no 10 pair tag block)
158Supplying and fixing certified Cat6 RJ45 data outlet onto existing faceplate with specified colour coding including termination of the Cat6 UTP cable at BOTH ends
159Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 6 way (4 + 18), Double door
160Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
161Triple pole and neutra
162Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25 A
16340 A
164Supplying of heavy duty XLPE insulated and PVC sheathed 1.1 kV grade conforming to IS:7098 Part-1/ IS:1554 Part-1 for aluminium/ copper conductor unarmoured/ armoured cable of the following sizes including fastening with nylon ties (internal), or galvanised MS saddles (external) as required. Cable to be drawn through existing trenches or laid on existing cable trays/ ladders. 3.5c50 sqmm aluminium armoured cable.
165Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
166Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 50 sq. mm (35 mm)
167Providing and laying of the following types & sizes of pipes including excavation and backfilling of trenches with proper base levelling and preparation with PCC where required in external spaces (excluding the cost of making suitably sized manholes) as specifed with brick plastered with water-proof compound and all required accessories for coupling, fixing and supports where required for internal use: 180/160 mm HDPE Double wall corrugated (DWC) pipe (laid underground in external spaces)
168125 mm HDPE Double wall corrugated (DWC) pipe (laid underground in external spaces)
169Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 300 mm width X 50 mm depth X 1.6 mm thickness
170Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 300 mm width X 50 mm depth X 1.6 mm thickness
171Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
172Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
173Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
174Supply the following lighting fixtures including, sampling, preparing inventory, storing, assembling, testing and fixing with all required supports and complete with supplying and fixing suitable lamps, ballasts (all fluorescent fixtures to have lowTHD electronic ballasts), condensors, ignitors, transformer, starters, with all necessary accessories for fixing or mounting fixtures in location viz down rods, suspension cables or chains, dash fasteners of suitable strength etc. as required. 20W Surface, Wall mounted or suspended type LED fixture with 2500 Lumen output, Philips Cat no.smart bright extra batten,BN 308C LED 20S L120 PSU or approved equivalent..
17512W,Surface mounted LEDDownlight fixture with 1200 Lumen output, Philips Cat no. SM250C LED12S.or approved equivalent..
176Supplying of high speed A.C. ceiling fan, 5 star ratingcomplete with all accessories down rod, canopy etc. of following sweeps with making necessary connections atc.as required complete and as directed by the department (without regulator). 1200 mm sweep
177Supplying of enegy efficent A.C. Exhaust fan in the existing hole on the wall of following sweeps and making necessary connections etc., as required complete and as directed by the Department. Heavy duty for 900/ 960 rpm 300 mm sweep
178Supply, installation, unloading, storing, fixing in position, testing and commissioningthe following sheet steel cubicle type fully compartmentalized panels fabricated from 1.6mm thick CRCA sheet, dust and vermin proof, indoor type TPN Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz AC supply and cable alley should be suitable for cable entry from top or bottom and with segregated bus-bar chamber with bus bars as specified below and including supplying and fixing following switchgears, meters and accessories, inter-connections, bonding to earth, powder coated painting and marking as specified. Switch boards complete as per schematic diagram: Type of construction: Form 3 Indoor IP classification: 42 Colour: Siemens Gray Powder Coated, as per approved sample. The BOQ shall be read in conjuction with general notes, specification and single line diagram (attached for ref.) In case of any disrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/ Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered. (Contd..)
179All MCCB shall be with door interlocked rotary handle with ON/TRIP/OFF position indicator, continuous variable thermal magnetic O/C and S/C releases. The MCCB 250A and above 250A rating shall be provided with microprocessor based releases (settable at site). Incomer MCCB shall be provided with E/F release also. All feeder doors shall have pad locking arrangement. All TP Feeders shall have solid isolable neutral link. Cable entries provisions shall be from the TOP and BOTTOM. The internal control wiring shall be fuseless. All control wiring and metering protection shall be by MCB"s. Removable lifting hook shall be provided in all transportation section. All bus bar shall be insulated with coloured PVC sleeve i.e. Red, Yellow, Blue and Black as per colour code.internal wiring of panel shall be with size 2.5sqmm flexible copper conductor for Cast Resin Type CT circuit and control wiring with 1.5sqmm. All indicating light shall be LED type. The contractor shall prepare proper GA drawings and shall seek approval for these from the project manager / electrical consultant prior to construction of all panels and boards. All live accessible parts shall be shrouded with 3mm thick polycarbonate /FRP sheet and all equipment shall be finger touch proof . (Contd...)
180Light & Power MDB:- INCOMER 1no. 100A, 25kA TPN MCCB with rotary operating handle with door interlock withthermal-magnetic release for O/L, S/C setting of 80%-100%,and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current, Frequency, Power, Energy and power factor with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sizedthree phase& neutral aluminium conductors busbar suitably sized to carry 160A currenthaving a maximum current density of1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 6no 40A TPN MCBs, 10kA (C Curve) 6no 25A TPN MCBs, 10kA (C Curve) 1No. 25x6 mm Aluminium Earth Bus stripacross the width of the Panel . Light & Power MDB completed as above
Disclaimer :