Dr.B.R.Ambedkar Memorial Hospital Raipur ( C.G. ) Invites E-Tender For Supply Of Implant Cardiology Dept. Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained From Https: / / Eproc.Cgstate.Gov.In-6 Left Heart Catheterisation ( In Package ) 12 Renal Angioplasty ( In Package ) 18 Physiological Pacing ( Left Bundle Branch Pacing ) Kit With Vvir Mri / Ddr Mri ( In Package ) 20 Pericardiocentesis ( In Package ) 23 Mitra Clip Procedure ( In Package ) 25 Balloon Atrial Septostomy ( In Package ) 26 Transcatheter Aortic Valve Implantation ( Tavi ) ( In Package ) 37 Introducer Sheath Femoral Atraumatic Tapered Tip, Enhanced Pushability And Flexibility, Hemostatic Valve Maintains Uncompromised Haemostasis To Avoid Bleeding And Air Aspiration, Enlarged Inner Diameter For Ultra Smooth Transition Between Dilator And Sheath, Lubricant Coating, Metallic Puncture Needle With Mini J Tipped Ptfe Guide Wire. Length 23Cm. All Sizes. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturer Should Be Over 2 Crore. 55 Coronary Dignostic Catheter: Al 0.75 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 61 Coronary Dignostic Catheter: Ar 3 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 65 Coronary Dignostic Catheter: Nih Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 67 Coronary Dignostic Catheter: Sones With Side Holes Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 68 Coronary Dignostic Catheter: Cobra 1 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr.Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 69 Coronary Dignostic Catheter: Cobra 2 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr.Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 70 Coronary Dignostic Catheter: Cobra 3 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 71 Coronary Dignostic Catheter: Simmons 1 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 72 Coronary Dignostic Catheter: Simmons 2 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 73 Coronary Dignostic Catheter: Simmons 3 Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Coronary Dignostic Catheter: Headhunter 1 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr . Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. Coronary Dignostic Catheter: Headhunter 2 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. Coronary Dignostic Catheter: Headhunter 3 Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. Coronary Dignostic Catheter: Renal Double Curve Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. Coronary Dignostic Catheter: Vitek Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. Coronary Dignostic Catheter: Hockey Stick Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 80 Coronary Dignostic Catheter: Sidewinder Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 81 Coronary Dignostic Catheter: Cournand Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 82 Coronary Dignostic Catheter: Vertebral Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 85 Coronary Dignostic Catheter: Src Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 86 Coronary Dignostic Catheter: Renal Diagnostic Catheter Large Inner Lumen, Hub Catheter Joint Should Be Durable, Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Procedures. Detailed Data For Flexibilty, Kink Test, Coating Integrity, Torque Strength, Pyrogenicity And Shelf Life Should Be Provided. Annual Turnover Of Manufacturers Should Be Over 2 Crore. 96 Guiding Catheter Specifications: Jl 4.5 With Sidehole Distal Tip Radio Opaque Marker, Large Inner Lumen, Encapsulated Metallic Wire Braid Provides Better Lumen And Kink Resistance Properties, Flexible Primary Curve For Active Engagement And Strong Secondary Curve For Backup Support, Stiffer Shaft, Lubricious And Non Thrombogenic Coating Both Outside And Inside.., Catheter Length: 100 - 110 Cm, Sizes 4 / 5 / 6 / 7 / 8 Fr. Clinically Used For Minimum 10 Years For Minimal Invasive Diagnostic Or Therapeutic Etc