}

Works Maintenance Operation Of 01 No 50 Kwp Solar Plants Installed At Ar Bn At Kohima- Maint / Manning And Operation Of 01 Nos Of 50 Kwp Solar Power Plant Along With Its Connected Equipments I.E. Control Panels, Battery Banks And Pv Modules Etc In, kohima-Nagaland

Assam Rifles-AR has published Works Maintenance Operation Of 01 No 50 Kwp Solar Plants Installed At Ar Bn At Kohima- Maint / Manning And Operation Of 01 Nos Of 50 Kwp Solar Power Plant Along With Its Connected Equipments I.E. Control Panels, Battery Banks And Pv Modules Etc In. Submission Date for this Tender is 10-10-2022. Indicators and Reagents Tenders in kohima Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

34069041
Corrigendum : Works Maintenance Operation Of 01 No 50 Kwp Solar Plants Installed At Ar Bn At Kohima- Maint / Manning And Operation Of 01 Nos Of 50 Kwp Solar Power Plant Along With Its Connected Equipments I.E. Control Panels, Battery Banks And Pv Modules Etc In
Open Tender
Indian
Nagaland
kohima
10-10-2022

Tender Details

Works Maintenance Operation Of 01 No 50 Kwp Solar Plants Installed At Ar Bn At Kohima- Maint / Manning And Operation Of 01 Nos Of 50 Kwp Solar Power Plant Along With Its Connected Equipments I.E. Control Panels, Battery Banks And Pv Modules Etc In Shift Of 08 Hrs Per Day By Employing Qualified Or Experienced Technician Including Comprehensive Maintenance Of All Above Equipment Installed At Solar Distribution Network In Ar Bn Kohima Main Office & Sig Cente Area By Maintaining Attendance Register Of Staff Employed All As Specified And Directed By Engr-In-Charge. Contractor Shall Quote His Rates For Manning / Maint And Operation Of 01 No Solar Power Plant And All Other Eqpt Including Cleaning Of Plant Areas, Monitoring / Recording Of Energy Production / Distribution Details With Following Terms And Conditions :- ( A ) Contractor Will Produce Character Certificate Issued By Police Station, Education / Qualification Certificate And Experience Certificate Belonging Minimum 02 Years Of The Staff Employed And Contractor Shall Be Responsible For Any Disciplinary Case Of Staff Employed ( B ) Necessary Life Insurance Will Be Done As Per Prevailing Rules For Tradesman Employed Through The Job And The Original Policy Documents Will Be Produced For Verification And Record Of The Accepting Officer Immediately On After Approval Of Technician ( C ) All Expenditure For Necessary T&P, Dress, Safely Hardness Eqpt, Comn, Stationery, Insurance Of Tradesman Etc As Per Specified In This Job Are Deemed To Be Included In The Quote Rate ( D ) All Payments Of Labours Will Be Done Through Nationalized Banks And Produced The Bank Statement To Department Before Claiming Bills. ( E ) Penal Charges :- If Any Of The Activity Above Is Not Performed By The Contractor Than Recovery As Under Will Be Affected :- ( I ) Absent On Duty Of Technician – Rs 1000 Per Shift ( Ii ) Not Cleaning Of Pv Modules And Plant Areas- Rs. 2500 Per Plant Month Note :- The Spares Replaced Under Comprehensive Maintenance Shall Be Measured And Paid Separately. 3 Supply, Installing, Testing And Commissioning Of Array Junction Box ( Ajb ) As Per Existing Size / Capacity Complete All As Directed And Specified 4 Supply Installing, Testing And Commissioning Of Field Junction Box ( Fjb ) As Per Size / Capacity Complete All As Directed And Specified 5 Supply, Installing, Testing And Commissioning Of Main Junction Box ( Mjb ) As Per Existing Size / Capacity All As Directed And Specified 6 Supply, Installing, Testing And Commissioning Of Pv Modules ( Photo-Voltaic Cell ) As Per Existing Size / Capacity Complete All As Directed And Specified 7 Supply Installing, Testing And Commissioning Of Pv Circuit Breaker Pc Box Of 250 Amp Capacity Complete All As Directed And Specified 8 Supply, Installing, Testing And Commissioning Of Dc / Ac Voltage Meter As Per Existing Size / Capacity All As Directed And Specified 9 Supply, Installing, Testing And Commissioning Of Dc / Ac Ampere Meter As Per Existing Size / Capacity Complete All As Directed And Specified. 10 Supply, Installing, Testing And Commissioning Of Solar E / Fax As Per Existing Size / Capacity Complete All As Directed And Specified 11 Supply, Installing, Testing And Commissioning Of Solar Dc Cables Of 6.00 Sqmm Complete All As Directed And Specified 12 Repair & Maint Of Old Existing Inverter Of System Voltage 240 / 360 / 480 Volts By Inspecting, Repair Of Replacement Of Internal Part Complete Along With Dc Wiring Connectionpcbs, Indicators Volts & Amp Meters ( Digital / Analogue Type ) And Make The Inverter Functional By Connecting To Existing Battery Bank All As Specified And Directed. Note:- If The Inverter Is Non-Repairable Then The Same Shall Be Replaced With Hybrid Type Inverter Of Suitable Capacity Wrt Existing System Voltage@ Rs. 14, 50, 000 / - 13 Fixing Only Battery Bank Of Suitable Capacity ( 600 Ah ) From Store Room To Solarplant Site And Connecting In Existing System By Taking Down Old Unserviceable Battery Bank From System Complete & Make The Plant Functional In All Respection Including Connection Upto Inverter Complete All As Specified & Directed Note:- ( A ) The New Battery Bank ( 500 / 600 / 1000 Ah ) Will Be Supplied As Schedule ‘B’ Stores Free For Fixing Only. ( B ) The Old Battery Bank Is Issued As Scheduled Of Credit To The Contractor. ( C ) The Battery Bank Qty Is 180 Or 240 Nos

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Oct-2022 DATE CORRIGENDUM Date 06-10-2022
2 07-Oct-2022 DATE CORRI Date 10-10-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 15500.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail