Addn / Altn To Md Accn Of Aipt Under Ge ( Central ) Pune - 1 Demolition Of Reinforced Cement Concrete Of Any Description And In Anypositionnot Otherwise Specifically Provided For Incl Rubish Off Outside Of Md Land Complete All As Sp, pune-Maharashtra

Military Engineer Services-MES has published Addn / Altn To Md Accn Of Aipt Under Ge ( Central ) Pune - 1 Demolition Of Reinforced Cement Concrete Of Any Description And In Anypositionnot Otherwise Specifically Provided For Incl Rubish Off Outside Of Md Land Complete All As Sp. Submission Date for this Tender is 08-11-2022. Building Work Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

34058654
Corrigendum : Addn / Altn To Md Accn Of Aipt Under Ge ( Central ) Pune - 1 Demolition Of Reinforced Cement Concrete Of Any Description And In Anypositionnot Otherwise Specifically Provided For Incl Rubish Off Outside Of Md Land Complete All As Sp
Open Tender
Indian
Maharashtra
pune
08-11-2022

Tender Details

Addn / Altn To Md Accn Of Aipt Under Ge ( Central ) Pune - 1 Demolition Of Reinforced Cement Concrete Of Any Description And In Anypositionnot Otherwise Specifically Provided For Incl Rubish Off Outside Of Md Land Complete All As Specified & Directed By Engineer Incharge. 2 Demolition Of Cement Concrete In Ground Floor And Paving N.Exc 15 Cm Thickness ( Below Or Above Ground Level ) Incl Rubbish Off Outside Of Md Land Complete All Asas Specified & Directed By Engineer Incharge. 3 Demolition Ofstone Slab / Tilesof Any Description Or Thickness Laid, Bedded And Pointed In Cement Mortar / In Floor, Skirting, Hard Standingg, Apron Etcincl Rubbish Off Outside Of Md Land Complete All As Specified & Directed By Engineer Incharge. 4 M&L Pcc 1:4:8 Type D-2 ( 40Mm Graded Crushed Stone Aggregate ) For Sub Base 50 Mm Thick Complete All As Specified & Directed By Engineer Incharge. 5 M&L For 75Mm Thick Pcc ( 1:3:6 ) Type B2 ( Using 20Mm Graded Crushed Stone Aggregate ) As In Plinth Protection / Path Finishing Cementconcrete Surface Even And Smooth Without Using Extra Cement Complete All As Specified & Directed By Engineer Incharge. 6 M&L For Precast Coloured, Chequered Cement Concrete Tiles, Glossy Finish Of Size 300 X 300 X 20 Mm Thick, Conforming To Is-1237 ( 2006 ) Set Jointed And Pointed In Neat Cement Slurry In Floor Laid Over And Including 20Mm Thick Screed Bed In Cm ( 1:6 ) Complete All As Specified & Directed By Engineer Incharge. 7 M&L For Machine Cut Kota Stone Slab In Flooring 20-25Mm Thick And Jointed With Grey Cement Slurry Mix With Pigment To Match The Shade Of The Slab Incl Rubbing Andmirror Polishing Complete Incl 20 Mm Thick Screed Bed Incm 1:6 All As Specified & Directed By Engineer Incharge. 8 M&L For Machine Cut Kota Stone Slab In Skirting 20-25Mm Thick And Jointed With Grey Cement Slurry Mix With Pigment To Match The Shade Of The Slab Incl Rubbing Andmirror Polishing Complete Incl 10 Mm Thick Backing Coat In Cm 1:4 All As Specified & Directed By Engineer Incharge. 9 Dismantling Offloor, Hearth Or Wall Tilinng Incl Cement Mortar Bedding ( But Not Backing ) And Rubbish Off Outside Of Md Land Complete All As Specified & Directed By Engineer Incharge. 10 M&L For Non - Skid Ceramic Coloured Joint Free Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Eachtile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Incl 15Mm Thick Screed Bed In Cm 1:6 Complete All As Specified & Directed By Engineer Incharge. 11 M&L For Non - Skid Ceramic Coloured Joint Free Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Eachtile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Skirting / Verical Surface Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Incl 10 Mm Thick Backing Coatcm 1:4 Complete All As Specified & Directed By Engineer Incharge. 12 M&L For Non - Skid Ceramic Coloured Joint Free Tiles 7 To 8 Mm Thick Area Of Eachtile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 15 Mm Thick Screed Bed In Cm 1:6 Complete All As Specified & Directed By Engineer Incharge. 13 M&L For Non - Skid Ceramic Joint Free Tiles 7 To 8 Mm Thick Colour Tile ( Square / Rectangular ) Area Of Eachtile Exceeding 0.18 Sqm But Not Exceeding 0.36 Sqm, In Skirting / Verical Surface Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Incl 10 Mm Thick Backing Coatcm 1:4 Complete All As Specified & Directed By Engineer Incharge. 14 M / L For Non Skid Ceramic Coloured Joint Free Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding0.06 Sqm But Not Exceeding 0.11 Sqm In Floor Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, With 15 Mm Thick Cement Screed Bed In Cm 1:6 Complete All As Specified & Directed By Engineer Incharge. 15 M&L For Glazed Ceramic Coloured Joint Free Tiles In Verticle Surfaces Of Approved Pattern Of Size 450X300x7mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Including10mm Thick Plaster In Cm 1:4As A Backing Coat Complete All As Specified & Directed By Engineer Incharge. 16 Taking Down Cementplaster On Brick Of Stone Walls Of Concrete Surfaces Etc Incl Racking Out Joints, Hacking For Key, Scrubbing Down With Water Etc. Incl Rubish Off Outside Md Land Complete All As Specified & Directed By Engineer Incharge. 17 Dubbing Out Average 10Mm Thick On Irregular Face Of Walls In Cm ( 1:4 ) ( When Specifically Ordered In Writing ) Complete All As Specified & Directed By Engineer Incharge. 18 M&L Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick-Work Or On Concrete Surfaces Finished With Sponge Finish Complete All As Specified & Directed By Engineer Incharge. 19 M&L Rendering 5 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Ceilling In Cm 1:3 Complete All As Specified & Directed By Engineer Incharge. 20 M&L Rendering 15 Mm Thick On Stone Masonry Surfaces Other Than Fair Faces Of Brick Work Or Stone Surfaces In Cm 1:6 Complete All As Specified & Directed By Engineer Incharge. 21 M&L Preparation Of Surfaces Of Plaster Fornewly Plaster Surface And Applying A Coat Of 1 Mm Thickness Putty To Obtain The True Line To Achieve Smooth Surface And Applying Two Coats Of Oil Bound Distemper On Wall All As Specified & Directed By Engineer Incharge. 22 Preparation Of Newly Plastered Surface Of Wall And Apply Three Coat Of White Wash On Ceilling Complete All As Specified & Directed By Engineer Incharge. 23 M&L For Preparation Of Newly Plaster Surface Of Wall And Apply Two Coat Of Cement Base Paint Including Alkali Resistance Primer Complete All As Specified & Directed By Engineer Incharge. 24 M & L Preparation Of Existingtreatment &Applying Thin Layer Of Wall Care Putty Andapplying Two Coatsof Oil Bound Distemper On Walls All Asspecified And Directed Over A Coat Of Primer Complete All As Specified & Directed By Engineer Incharge. 25 Preparation Of Old Plastered Surface Of Wall And Apply Three Coat Of White Wash On Ceilling Complete All As Specified & Directed By Engineer Incharge. 26 M & L Preparation Of Old Surfacesof Wall And Apply Two Coat Of Cement Base Paint Complete All As Specified & Directed By Engineer Incharge. 27 S&F Stainless Steel Plate Rack Made Of 1.00 Mm Thick Sheet Grade Ss- 304 Of Standard Size 36X36X8 And Of Approved Quality Of Finish All As Specified And Directed And Of Isi Mark. Make : Blue Star Or Equivalent Complete All As Specified & Directed By Engineer Incharge. 28 S & F In Repairs Stainless Steel Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick With Plugs Washers And Waste Including Bedding In Cement Mortor Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915 Mmx 460 Mm Bowl Size 410 Mm X 330Mm X 160 Mm Complete All As Specified & Directed By Engineer Incharge. 29 S&Fin Repair Chromium Plated 15Mm Dia Bib Taps, Cast Copper Alloy With Crutchhandle, Screwed Down, Screwed For Iron Pipes Complete All As Specified & Directed By Engineer Incharge. 30 S&F In Repairfor Chromium Plated Angular Stop Valves Cast Copper Alloy Screwed Down High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Bore Of Size 15Mm Complete All As Specified & Directed By Engineer Incharge. 31 S & F In Repairvitreous China Washhand Basin Whiteflat Back Size 550X 400 Excluding Taps Waste Chain And Plug And Porcelain Stopper But Incl Necessary Brackets Cp Brass Wastes Coupling And Other Fittings All As Specified & Directed By Engineer Incharge. 32 S&F In Repair Pvc Flushing Cistern Low Level 10 Ltrs Capacity Including Brackets For Flush Tank, Pvc Flush Pipe And All Necessary Fittings Etc Complete All As Specified & Directed By Engineer Incharge. 33 S&F In Repair Chromium Plated 15Mm Dia Pillar Taps , Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, High Pressure Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts Screwed For Iron Pipescomplete All As Specified & Directed By Engineer Incharge. 34 S&F In Repairs Mirror Of Size 600 X 450 Thick Bevelled Edge Mirror Of Selected Quality Glass Mounted On 6 Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified & Directed By Engineer Incharge. 35 S&F In Repairs Soap Dish, Any Type, Fixed To Plugs With Chromium Plated Brass Screws Complete All As Specified & Directed By Engineer Incharge. 36 S&F In Repairs Towel Rail 600 Mm Long Of Ptmt Any Colour For Fixed With And Including Chromium Plated Brass Screws And Wooden / Plastic Cleats ( Minimum Weght 190 Gms ) All As Specified & Directed By Engineer Incharge. 37 S&F In Repairs Cp Shower Roses With Or Without Swivel Joints 125Mm Size, Including Fixing To Steel Pipe Or Union Complete All As Specified & Directed By Engineer Incharge. 38 M&L Pvc ( Swr ) Floor Trap With Steel Grating 75 Mm Dia Including Jointing To Waste Pipe Including Removing Old Traps All As Specified & Directed By Engineer Incharge. 39 Demolition And Breaking Of Drain Pipes Ac / Ci / Pvc Set In Cement Mortar Or Adhensive All As Directed Of Dia 100 Mm Dia All As Specified & Directed By Engineer Incharge. 40 S&F For 110 Mm Dia Pvc Swr Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Floor Including Clamp Etc All As Specified & Directed By Engineer Incharge.. 41 S&F For 75 Mm Diaswr Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall Including Clamp Etc All As Specified & Directed By Engineer Incharge.. 42 S&F For 75 Mm Diaswr Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Floor Including Clamp Etc Complete All As Specified & Directed By Engineer Incharge. 43 S&F Pvc ( Swr ) Single T 75 Mm Dia With Access Door All As Specified & Directed By Engineer Incharge. 44 S&F Pvc ( Swr ) Bend 75 Mm Dia All As Specified & Directed By Engineer Incharge. 45 S&F Pvc ( Swr ) 75 Mm Dia Vent Cowl All As Specified & Directed By Engineer Incharge. 46 S&F In Repair Pvc 32 Mm Dia Flush Pipe Suitable For Low Level Cistern All As Specified & Directed By Engineer Incharge. 47 S&Fpvc Connection15 Mm Size With Ptmt Nuts Of Length 600 Mm All As Specified & Directed By Engineer Incharge. 48 Supply And Fix In Repairs Vitreous China Squatting Pan Orissa Pattern Wash Down Water Closet Of Size 580X440 Mm, White, With Integral Foot Rests Complete Fixed In Repairs With P Or S Trap, And All Necessary Fittings Etc Complete All As Specified & Directed By Engineer Incharge.. 49 S&F In Repair Vitreous China Pedestal Pattern, White With Including Cast Iron P Or S Trap Andconnection To Trap Includintg Cement Concrete, Seat Cover And Jet Spray Etc. Including Making Good To Floor, Complete All As Specified & Directed By Engineer Incharge. 50 S & F In Repairs 15 Mm Chromium Plated 2 Way Bib Cock With Wall Flange Confirming To Cat No. F2002161 Of Cera Or Of Equivalent Make Specified All As Specified & Directed By Engineer Incharge. 51 S & F In Repairs Cp Toilet Paper Holder Conforming To Cat No. Acn-1151 N Of Jaquar Specified Here In After All As Specified & Directed By Engineer Incharge. 52 S & F In Repairs Health Faucet Conforming To Cat No. Ald-573 As Mentioned Of Make Jaquar Or Of Equivalent All As Specified & Directed By Engineer Incharge. 53 S&F15mm Bore Gi Water Tubing Medium Grade Fixed Including Taking Down Gi Tubing & Connection 15Mm Dia Laid In Floor / Trenches Or Fixed To Walls Complete To Wall Or Ceiling As Specified & Directed By Engineer Incharge. 54 S&F 20 Mm Bore Gi Water Tubing Medium Grade Fixed Complete To Wall Or Ceiling Including Taking Down Gi Tubing & Connection 20Mm Dia Laid In Floor / Trenches Or Fixed To Walls As Specified & Directed By Engineer Incharge. 55 M&L 20Mm Thick Granite ( Of Any Type ) Work Table Rubbed And Pre Polished As In Cooking Platforms , Window Cill, Steps, Wall Cladding And Like In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixtures Of Pigment To Match With Shade Of Granite Complete And Ensure Best Adhesion To Surface Including Screed Bed Of 15Mm Thick In Cm ( 1:6 ) For Laying Floor Finishes Complete All As Specified & Directed By Engineer Incharge. 56 M&Lmachine Cut Cudappah Stone Slab 20-25Mm Thick Over Cement Screed Base In 10Mm Thick Cm ( 1:4 ) , Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete Including Screed Bed Of 15Mm Thick In Cm ( 1:6 ) For Laying Floor Finishes All As Specified & Directed By Engineer Incharge. 57 Rounding To Edges Of Stone Slabsone Edge, Such As In Steps, Cooking Platform, And Other Similar Situations All As Specified & Directed By Engineer Incharge. 58 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frame ) Area Exc. 1.50 Sqm And Not. Exc. 4Sqm. Each All As Specified & Directed By Engineer Incharge. 59 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frame ) Area N Exc. 1.50 Sqm Each All As Specified & Directed By Engineer Incharge. 60 Taking Down Shutters Of Any Description Exc 1.0Sqm And N Exc 2.00 Sqmeachetc Complete All As Specified & Directed By Engineer Incharge. 61 Taking Down Shutters Of Any Description And Refixing In Same Opening Exc 1.0Sqm And N Exc 2.00 Sqm Eachetc Complete All As Specified & Directed By Engineer Incharge. 62 M & Lfor 2 Nd Class Hardwoodplain, Solid, Straightchowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinnedat Joints, Suppliedandfixed All As Specified & Directed By Engineer Incharge. 63 S&F Aluminium Powder Coated Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc Complete All As Specified & Directed By Engineer Incharge. 64 S&F Three Track Sliding Window With Two Or More Shutter With 4Mm Thick Tinted Glass One Shutter Using Stainless Steel Wire Cloth 0.36Mm Nominal Dia & 1.18Mm Width Aperture For Mosquito Proofing With Good Quality Bearing Handle, Lock, Rubber Beading And Glazing Clips Etc Using Following Aluminium Powder Coated Sections Conforming To Catalogue Of Jindal Or Of Equivalent Make Complete All As Specified And Directed By Engr-In-Charge. ( A ) Bottom Frame - 20620 ( B ) Top Frame & Vertical - 20621 ( C ) Handle ( Side ) - 20606 ( D ) Shutter Inter Lock - 20724 ( E ) Shutter Top & Bottom - 20844 ( F ) Glazing Clips - 19352 All As Specified & Directed By Engineer Incharge. 65 S&F Fixed Glass Louvered Ventilators Using 5Mm Thick Pin Headed Glass And Following Aluminium Powder Coated Sections Conforming To Catalogue Of Jindal Or Of Equivalent Make And Rubber Beading Etc All As Directed. ( A ) Sp - 20048 ( B ) Glazing Clips - 19352. Complete All As Specified And Directed By Engineer-In-Charge. 66 S&F In Repair 18 Mm Thickmdf Boardprelaminated Both Side With Decorative Choice Lamination As In Office Cabinet, Pelmate Box, Drawer, Cb Shutter Etcfixed With Screw Including 6Mm Thick, 1St Class Hw ( Tw ) Beading All Around On Edging To Timber Frame Work All As Specified And Directed By Engr-In-Charge . 67 S&F 35 Mm Thick Glazed And Skeleton Shutter Open Rebated And Prepared To Receive Glass, Iind Class Hardwood Gauge Etc Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Stile As Per Beads For Securing Glass Etc, The Size Of Therail And Site As Per Is 1003 ( Part -I ) , Kiln Seasoned And Chemically Presure Treated As Specified And Directed By Engr In Charge. 68 Supply And Fixing 4Mm Thick Sheet Glass Ordinary Quality Andglazing Fixed To Aluminium Window / Ventilator Shutters / Steel Windows Etc All As Specified & Directed By Engineer Incharge. 69 S&F Stainless Steel Wire Cloth, 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples .Including Fillet All As Specified & Directed By Engineer Incharge. 70 S&F 35Mm Thick Flush Shutters, Solid Core Onstruction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides, One Face Is Covered With Decorative Face Veneer With Lipping / Frame To Match Complete All As Specified & Directed By Engineer Incharge. 71 S&F Butt Hinges 100Mm, Medium Weight Complete All As Specified & Directed By Engineer Incharge. 72 S&F 150 Mm Extruded Aluminium Alloy Powder Coated Handles , Fabricated Type Isi Marked All As Specified & Directed By Engineer Incharge. 73 S & F Aluminium Anodised Powder Coated Barrel Tower Bolt Of Extruded Section 150Mm Long Isi Marked All As Specified And Directed By Engineer Incharge. 74 Supply & Fixingaluminium Alloy Anodisedsliding Door Bolts With Hasp And Stapple ( Bolt Type And Fxing Clips Of Sheet, Cast Or Extruded Section And Fixing Bolts And Sliding Bolts Of Extruded Sectionof 250Mm Long Isi Marked All As Specified & Directed By Engineer Incharge. 75 M & L 75 Mm Hasp And Staple, Safety Type, Brass With Mild Steel Hinge Pin Including Bolt To Hinge Plate And Fixed With Screwsall As Specified & Directed By Engineer Incharge. 76 Preparation Of New Or Previously Untreated Wood And Wood Based Surfaces Of Any Description, Not Otherwise Described, Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint ( Ordinary Tint ) Over A Coat Of Pink Primer All As Specified & Directed By Engineer Incharge. 77 Preparation Of Old Or Previously Untreated Wood And Wood Based Surfaces Of Any Description, Not Otherwise Described, Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint ( Ordinary Tint ) All As Specified & Directed By Engineer Incharge. 78 M&Lpreparation Old Paintedsteel Surface Of Any Description Over 10 Cm Width Or Girth Not Other Wise Described And Appying One Coat Of Syntheticenamel Paint All As Specified & Directed By Engineer Incharge. 79 S&F Curtain Rod 20 Mm Dia Decorative Type Powder Coated Aluminium Section All As Specified & Directed By Engineer Incharge. 80 S& F Decarative Type Funnel / Bracket To Suit The Curtain Rod Of 20 Mm Dia Powder Coated All As Specified & Directed By Engineer Incharge. 81 S&F Factory Madewood Grain Printed ( Prelaminated ) Solid Pvc Single Door Frame Of Size 50 X 47 Mm With A Wall Thickness Of 5Mmprelaminated Colour Sheet Reinforced With 19 Mm X 19Mm Ms Square Tube Having Wall Thickness 19 Guge Complete All As Shown In Sketch On Page 180 Of Ssr 2020 Part Ii Complete All As Specified & Directed By Engineer Incharge. 82 S&F Factory Made Wood Grain Printed ( Prelaminated ) Solid Panel Pvc Door Shutter 30Mm Thick ( Style ) Consisting Of Frame Made Out Of Ms Tubes 19 Mm X 19 Mm Having Wall Thickness 19 Gauge For Stiles.Ms Tube 15Mmx 15Mm Having Wall Thickness 19 Mm Gauge For Top And Bottom Rails.Ms Frame Shall Be Covered With 5Mm Thick Heat Moulded Prelaminated Colour Pvc C Channel Having 5Mm Thick Pvc Sheet Strip 20Mm Wide Struck Inside With Solvent Cement For Stiles And 5Mm Thick Pvc Sheet For Top Rail, Lock Rail And Bottom Rail On Either Side And 10Mm ( 5Mm X 2Mm ) Thick, 20Mm Wide Cross Pvc Sheet As Gap Insert For Top And Bottom Rail. Paneling Of 5Mm Thickprelaminated Colour Pvc Sheet To Be Fixed In Ms Frame Welded / Sealed To The Stiles And Rails With 5Mm X 30 Mm Pvc Sheet Beading And Jointed Together With Solventcement Complete All As Shown In Drg Give On Page 177 Of Ssr 2020 Part Ii.The Width Of Stiles And Rails Shall Be As Specified In Para 8B.2.1 On Page 145 Of Ssr 2020 Part Ii.Each Pvc Door Shutter Leaf Consist Of 4 Nos 100 Mm Long Msbutt Hinges All As Specified & Directed By Engineer Incharge. 83 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided All As Specified & Directed By Engineer Incharge. 84 S&F Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings ( Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides ) And Hanging; Also Fastening And Fixing Complete Fe 410 -W ( Gdee- 250 ) All As Specified & Directed By Engineer Incharge. 85 S&F Mild Steel Framed Work Such As Grills, Gratings, Etc., With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes, Framed Guard Bars, Barred Iron Doors, Door Chowkats Of Angle Or Other Section And Similar Works Complete Of Fe-290 Gde E-165 Including Welding Etc All As Specified & Directed By Engineer Incharge. 86 Dismantling Of Single Layer Manglore Pattern Tiles And Ridge In Roofing / Ac Sheet / Gi Sheet Roofing All As Specified & Directed By Engineer Incharge. 87 Dismantling Of Fillets, Rails, Posts, Rafters, Purlins, Etc.Unframed Workunder 40 Sq. Cm In Section All As Specified & Directed By Engineer Incharge. 88 Dismantling Boarding, Framing Any Description, And Any Size Of Framingfixed In Any Position With Nails All As Specified & Directed By Engineer Incharge. 89 Dismantling Timber Scantling Of Size 40 Sqcm And Over In Section As In Unframed Work All As Specified & Directed By Engineer Incharge. 90 M&L Roof Tiles, Mangalore Pattern, Interlocking At Side Joints, Laid Dry All As Specified & Directed By Engineer Incharge. 91 M&L Ridge Or Hip Tiles To Suit Mangalore Pattern Of Roofing Tiles, Bedded And Jointed In Lime Mortar 1:3 Or Cement Mortar 1:6All As Specified & Directed By Engineer Incharge. 92 M & Liind Class Softwood Clean Sawn Batttens At 30 Cm Centres To Centre Of Section Area 15 & Nexc 25 Sqm All As Specified & Directed By Engineer Incharge. 93 Fixing Onlyroof Tiles, Mangalore Pattern, Interlocking At Side Joints, Laid Dry All As Specified & Directed By Engineer Incharge. 94 S& F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.5Mm Thick Of An Colourhaving Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws All As Specified & Directed By Engineer Incharge. 95 S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Clading To Wallfixed Withself Taping Screws All As Specified & Directed By Engineer Incharge. 96 M&L Rooftrusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc, Wind Ties Etc Grade Fe-410-W Quality A ( Grade-250 ) All As Specified & Directed By Engineer Incharge. 97 S&F Megnetic Catcher For Cabinets All As Specified & Directed By Engineer Incharge. 98 S&F In Repair For Stainless Steel Peg Set Of Sixall As Specified & Directed By Engineer Incharge. 99 M&Lpreparation New Paintedsteel Surface Of Any Description Over 10 Cm Width Or Girth Not Other Wise Described And Appying Two Coat Of Syntheticenamel Paint Over A Coat Of Primer Complete All As Specified & Directed By Engineer Incharge. 100 Dismantaling Wallandceilingboards ( Fibre, Pulp, Insulation, Etc. ) Or Insulationboards / Slabs / Blankets, Any Thickness, Including Cover Filletetc Complete All As Specified & Directed By Engineer Incharge. 101 M&L For 8 Mm Thick One Side Laminated Gypsum Ceiling Board For False Ceiling Of Size 600 X600x Mmonaluminium Powder Coated Grid Work 60 Cm X 60 Cm With Using 36.5 Mm X 23.5 Mm X1.5 Mm Thick Main Tee, 23.5 X 23.5 Mm X 1.28 Cross Tee And 25 X 25X 1.5 Mm Angles Fixed To Perimeter Of Wall For False Ceiling Including Necessary Supporting Hanger With 4.0 Mm Dia Gi Wire And J Bolts Washer Nuts For Securing Frame Work To Ceiling Suspended @ 120 Cm C / C Both Ways, Size Of Grid Shall Be 605 X 605 Mm, All As Specified & Directed By Engineer Incharge. 102 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar All As Specified & Directed By Engineer Incharge. 103 M&L For Precast Cement Concrete Block Masonry Exceeding 10Cm In Width With Solid Blocks Of Pcc ( 1:5:8 ) Gde D-5 And Setting In Cm 1:6 All As Specified & Directed By Engineer Incharge. 104 Supply And Fixedrotational Moulded Polyetylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Of 500 Litres Capacityhoisted And Fixed In Position And Connecting Up Pipes And Ball Valve Complete Set Of Ptmt, Securing Access Covers All As Specified And Directed Including Disconnecting Existing Water Tank Complete All As Specified & Directed By Engineer Incharge. 105 Removing Of Existing Old Bitumenous Tarfelt Including Cement Screed Bed And Clean The Surface With Wire Brush And Washing With Water To Achieve The Original Surface Of Slab All As Specified And Directed.Incl Rubbish Off Outside Of Md Land All As Specified & Directed By Engineer Incharge. 106 M & L Water Proofing Treatment To Rcc Roof Slab, Walls, Chhajjas Etc, Shall Be Carried Out As Specified Below And As Directed By Engineer-In-Charge Including Floowing . ( A ) M&L For 10Mm Thick Plaster Screed Bed Layer In Cm 1:3 On Concrete Surfaces. ( B ) Preparing Plastered Surfaces Of Roof Slab, Walls, Chhajjas Etc, By Brooming With Broom Sweeping Free From Dirt Dust Etc & Evenly Applying A Coat Of Approved Bitumnous Primer @ 0.20Kg / Sqm Of Area Complete All As Specified. ( C ) Laying App Polymer Modified Approved Membrane, Non Woven, Polyester, Weighingnot Less Than 3.5 Kg / Sqm And 3Mm Thick With Laps & Overlaps As Specified & Joints Sealed And Applied Complete By Torch Application Method All As Specified & Directed By Engineer Incharge.Carrying Out Test By Flooding Water For 24 Hrs For Leakagge & Seepages And Rectifyingthe Same To The Entire Satisfaction Of Ge. ( D ) Finally Applying A Coat Of Solar Reflective Bituminous Aluminiumpaint @ 0.15 Ltr / Sqm On The Top Of Membranesurfaces Complete All As Specifed & As Directed By Engr In Charge. 107 M&L Forpcc 1:2:4 Type Bo ( Using 12.5 Mm Graded Crushed Stone Aggregate ) As In Pcc Padding In Roof Kerbs Or Mud Stops, Rounded And Chamfered On Edgesand On Chajjas Laid Over Rcc Surface Fineshed Even And Smooth Without Using Extra Cement Including Necessary Water Proofing Chemicals All As Specified And Directed By The Engr-In-Charge. ( Note: Wpc Shall Be Measured And Paid Separately ) 108 Spply Only Integral Water Proofing Compound All As Specified & Directed By Engineer Incharge. 109 Taking Down Old U / S Point Wiring ( Light / Fan / Socket / Power ) Complete, Including Fixtures And Fittings Such As Switches, Sockets, Ceiling Roses, Pendants, Regulators, Light Fittings Etc. Removing Materials For Taking Credit And Making Good The Disturbed Surfaces Of Walls / Floors / Ceiling Etc.Complete All As Specified & Directed By Engineer Incharge. 110 Taking Downmain Switches / Dbs Of Any Make And Type Including Teakwood Board, Mcbs / Mccbs Etc. Complete And Making Good The Disturbed Surfaces Including Colour Wash Complete All As Specified & Directed By Engineer Incharge. 111 Taking Down Old Unserviceable / Worn Out Sub Main Wiring Of Any Type And Size Complete All As Specified & Directed By Engineer Incharge. 112 Taking Down Fans, Removing To Workshop For Servicing, Cleaning, Lubricating, Spray Painting One Coat With Synthetic Enamel Paint, Writing Mes No. Replacement Of Split Pin, Rubber Bush And Other Spare Required If Any Including Fixing Pvc Cable With Stranded Copper Conductor Of Size 0.75 Sqmm And Refixing The Fans At The Same Locations Complete For The Following Sizes. 113 M&L For Point Wiring Of Any Length Using Approved Colour Coding As Per Is With Stranded Copper Conductor 1.5 Sq.Mm ( Nominal Area ) Single Core, Pvc Insulated And Unsheathed Stranded Frlscable 1100 Volts Grade, Is - 694 Marked In Pvc Casing Caping Heavy Duty Isi Marked Including All Accessorieswith Pvc Modular Boxes, Modular Frame / Cover Plate Suitable For Mounting Switches / Sockets Etc. And Pvc Insulated Stranded Copper Conductor 1.5 Sqmm Single Core Cable As Earth And Connecting To Common Earth Dolly Complete All As Specified For The Following:- 114 ( A ) One Light Point Controlled By One, One Way Switch 115 ( B ) One Ceiling / Exhaust Fan Point Controlled By One, One Way Switch Andregulator. 116 ( C ) One Three Pin 5 Amps Socket Outlet Point Controlled By One No One Way Switch On Same Board 117 ( D ) One Three Pin 5 Amps Socket Outlet Point Controlled By One No One Way Switch On Independent Board 118 ( E ) One Bell Point Controlled By One Switch 119 All As Per Item No. 5 Above But With Stranded Copper Conductor 2.5 Sq. Mm ( Nominal Area ) , Single Core, Pvc Insulated And Unsheathed Multistranded Frls Cable 1100 Volt Grade Isi-694 Markedfor 3 Pin, 15 Amp Socket Outlet, Independent, Including Pvc Insulated Multistranded Frls Copper Conductor 2.5 Sqmm ( Nominal Area ) Single Core As Earth Continuity Conductor To Common Earth And Connecting To Earth Dolly All As Specified & Directed By Engineer Incharge.. 120 S & F For Modular Switch One Way 6 A, 1 Module Complete All As Specified & Directed By Engineer Incharge. 121 S & F For Modular Switch One Way 16 A, 1 Module, With Neon Indicator Complete All As Specified & Directed By Engineer Incharge. 122 S & F For Modular Socket, 6A - 2 / 3 Pin Combined 2 Module Complete All As Specified & Directed By Engineer Incharge. 123 S & F For Modular Socket, 6A / 16A - 2 / 3 Pin Combined 2 Module Complete All As Specified & Directed By Engineer Incharge. 124 S & F For Celling Rose 2 / 3 Terminals, Pvc / Polycarbonate, Isolated Body Isi Marked Complete All As Specified & Directed By Engineer Incharge. 125 S & F For Modular Stepped Type Fan Regulator, 2 Module Complete All As Specified & Directed By Engineer Incharge. 126 S & F For Bell, Multi Music Complete All As Specified & Directed By Engineer Incharge. 127 S & F For Modular Bell Push 6 Amp, 1 Module Complete All As Specified & Directed By Engineer Incharge. 128 S&F Vertical 4 Way Tpn Double Door, Recess Mounted / Wall Mounted, Mccb As Incomer And Outgoing Mcb Sp / Tpis 3 Pole V-Tec Of 100A Rating & 16Ka Breaking Capacity, Mccb Is Pre-Fitted At Factory & Including Price Of Mccb, All As Specified & Directed By Engineer Incharge. ( Note : Empty Space Shall Be Covered By Blanking Plate And Connect With Lugs Withoutany Extra Cost ) 129 S & F Db4 Way Tpn Double Door, Recessed Mounted / Wall Mounted, Mcb As Incomer Is 3 Pole And Neutral Of 63 A Rated Capacity And 16Ka Breaking Capacity All As Specified & Directed By Engineer Incharge. 130 S & Fmcb Four Pole Rated Capacity 63 Amps, 430 / 440 V Breaking Capacity 10 Ka , C- Curve Complete All As Specified & Directed By Engineer Incharge. 131 S & F For Mcb Db Spn Sheet Metal Enclosure, 8 Way With 200 Amps Rated Bus Bar Double Door, Fixed On Wallgood To Disturbed Surfaces, And Connecting With Existing Cable Complete All As Specified & Directed By Engineer Incharge. 132 S & F For Mcb Double Pole Ofrated Capacity 32 Amps, 240 Volts Breaking Capacity 10 Ka, C-Curve Complete All As Specified & Directed By Engineer Incharge. 133 S & Ffor Mcb Single Pole Rated Capacity 6 To 32 Amps, 240 V Breaking Capacity 10 Ka , C- Curve Complete All As Specified & Directed By Engineer Incharge. 134 M & Lfor Sub Main Wiring With 2 Runs Of Single Core 4 Sqmm Pvc Insulated Unsheathed Multistranded 1100 Volts Grade With Copper Conductor Drawn Through And Including Non-Metallic Rigid 20 Mm Pvc Rigid , Isi Marked And Itsaccessories Duly Pvc Conduit In Wall / Roof / Floor Including One Run Of Single Core 4 Sqmm Pvc Insulatedunsheathed Multistranded 1100 Volts Grade With Copper Conductor Cable As Earth Continuity Conductor Along With The Wiring And Connected From Db To Db / Main Board Complete All As Specified & Directed By Engineer Incharge. 135 S & F Lamp Holder ( Angle / Bracket ) Insulated Body, With Back Plate For Batten Fittings Including Led Bulb Of Cap8w 2 Pin Type Complete For 230 V 50Hz Ac Supply Complete All As Specified & Directed By Engineer Incharge. 136 S&F In Replacement Of Led Light Fitting Surface And Wall Mounted Led Batten With Aluminium Housing & Integrated Electronic Driver Complete In All Respect Of 10W Cap. Cat Part No Bclsb 10 Whof Make - Bajaj Or Equivalent In Other Approved Makes All As Specified & Directed By Engineer Incharge. 137 S&F Led Security Light In Replacement Ofluminaries 30 Watt Complete With All Accessories Andwall Mounting Bracket Of Suitable Size Including Clamps, Nut Bolts Etc. Prewired Conforming To Havells Cat Part No. Bclst 30W Led Ior Equivalent In Other Approved Makes All As Specified & Directed By Engineer Incharge. 138 Supply And Fix Led Tube Light Fittings Surface And Wall Mounted Led Batten, Extruded Aluminium Housing Provided For Efficient Heat Dissipation With Polycarbonate Diffuser & Integrated Electronic Driver With Industrial Grade Heavy Duty Driver 20 W Led Complete Including All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable Ofsuitable Size From Ceiling Rose To Connector. Conforming To Cat Part No.Enduralinearneobs20wled865spcwh All As Specified & Directed By Engineer Incharge. 139 M&L For Earthing With Galvanised Steel Earth Plate Electrode 60 Cm X 60 Cm X 6 Mm Buried Directly In Ground Earth Pit Not Less Than 2.25 M Deep Below Normal Ground Level, With Top Edge Of The Plate Vertically To Depth Of Not Less Than 1.5 M Below Ground Level Connected To And Incl Gi Wire 4 Mm Dia And Gi Pipe 15 Mm Dia Light Grade For Protection To The Extent Of 7.5 M As Earthing Lead By Means Of Gi Bolts And Nuts Etc Connecting To Equipment With Provn Of Charcoal And Salt Etc All As Per Electrical Plate No 3 Of Ssr Part-I Incl Rcc Cover And Ms Angle Iron Frame, Watering Arrangement With Gi Pipe 20 Mm Dia And Ms Funnel, Concrete Pit Incl Excavation And Earth Work In Any Type Of Soil And Testing On Completion Etc Complete ( Note:-Gi Earth Strip And Protection Pipe Beyond 7.5M Will Be Measured And Paid Separately ) All As Specified & Directed By Engineer Incharge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Oct-2022 DATE CHANGE Date 27-10-2022
2 17-Oct-2022 AMENDMENT NO 2 BOQ 27-10-2022
3 17-Oct-2022 AMENDMENT NO 2 BOQ 27-10-2022
4 19-Oct-2022 AMENDMENT nO 3 Date 01-11-2022
5 21-Oct-2022 AMENDMENT No 3 Terms and Conditions 01-11-2022
6 01-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-11-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 223000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:ADDN/ALTN TO MD ACCN OF AIPT UNDER GE (CENTRAL) PUNE
Sl. No. Item Description
1Demolition of Reinforced cement Concrete of any description and in anypositionnot otherwise specifically provided for incl rubish off outside of MD land complete all as specified & directed by Engineer Incharge.
2Demolition of Cement concrete in ground floor and paving n.exc 15 cm thickness (below or above ground level) incl rubbish off outside of MD land complete all asas specified & directed by Engineer Incharge.
3Demolition ofstone slab/tilesof any description or thickness laid, bedded and pointed in cement mortar/in floor, skirting, hard standingg, Apron etcincl rubbish off outside of MD land complete all as specified & directed by Engineer Incharge.
4M&L PCC 1:4:8 type D-2 (40mm graded crushed stone aggregate ) for sub base 50 mm thick complete all as specified & directed by Engineer Incharge.
5M&L for 75mm thick PCC (1:3:6) type B2 (using 20mm graded crushed stone aggregate) as in plinth protection/Path finishing cementconcrete surface even and smooth without using extra cement complete all as specified & directed by Engineer Incharge.
6M&L for precast coloured, chequered cement concrete tiles, glossy finish of size 300 x 300 x 20 mm thick, conforming to IS-1237 (2006) set jointed and pointed in neat cement slurry in floor laid over and including 20mm thick screed bed in CM (1:6) complete all as specified & directed by Engineer Incharge.
7M&L for machine cut Kota stone slab in flooring 20-25mm thick and jointed with grey cement slurry mix with pigment to match the shade of the slab incl rubbing andmirror polishing complete incl 20 mm thick screed bed inCM 1:6 all as specified & directed by Engineer Incharge.
8M&L for machine cut Kota stone slab in skirting 20-25mm thick and jointed with grey cement slurry mix with pigment to match the shade of the slab incl rubbing andmirror polishing complete incl 10 mm thick backing coat in CM 1:4 all as specified & directed by Engineer Incharge.
9Dismantling offloor, hearth or wall tilinng incl cement mortar bedding (but not backing) and rubbish off outside of MD land complete all as specified & directed by Engineer Incharge.
10M&L for Non - skid Ceramic coloured joint free tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 complete all as specified & directed by Engineer Incharge.
11M&L for Non - skid Ceramic coloured joint free tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting/Verical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10 mm thick backing coatCM 1:4 complete all as specified & directed by Engineer Incharge.
12M&L for Non - skid Ceramic coloured joint free tiles 7 to 8 mm thick area of eachtile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified & directed by Engineer Incharge.
13M&L for Non - skid Ceramic joint free tiles 7 to 8 mm thick colour tile (square/ rectangular) area of eachtile exceeding 0.18 sqm but not exceeding 0.36 sqm, in skirting/Verical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10 mm thick backing coatCM 1:4 complete all as specified & directed by Engineer Incharge.
14M/L for non skid ceramic coloured joint free tiles 7 to 8 mm thick (square/rectangular)area of each tile exceeding0.06 sqm but not exceeding 0.11 sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in CM 1:6 complete all as specified & directed by Engineer Incharge.
15M&L for glazed ceramic coloured joint free tiles in verticle surfaces of approved pattern of size 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including10mm thick plaster in CM 1:4as a backing coat complete all as specified & directed by Engineer Incharge.
16Taking down cementplaster on brick of stone walls of concrete surfaces etc incl racking out joints, hacking for key, scrubbing down with water etc. incl rubish off outside MD land complete all as specified & directed by Engineer Incharge.
17Dubbing out average 10mm thick on irregular face of walls in CM (1:4) (when specifically ordered in writing) complete all as specified & directed by Engineer Incharge.
18M&L rendering 10 mm thick in cement mortar 1:6 on fair faces of brick-work or on concrete surfaces finished with sponge finish complete all as specified & directed by Engineer Incharge.
19M&L Rendering 5 mm thick on fair faces of brick work or concrete surfaces in ceilling in CM 1:3 complete all as specified & directed by Engineer Incharge.
20M&L rendering 15 mm thick on stone masonry surfaces other than fair faces of brick work or stone surfaces in CM 1:6 complete all as specified & directed by Engineer Incharge.
21M&L preparation of surfaces of plaster fornewly plaster surface and applying a coat of 1 mm thickness putty to obtain the true line to achieve smooth surface and applying two coats of oil bound distemper on wall all as specified & directed by Engineer Incharge.
22Preparation of newly plastered surface of wall and apply three coat of white wash on ceilling complete all as specified & directed by Engineer Incharge.
23M&L for preparation of newly plaster surface of wall and apply two coat of cement base paint including alkali resistance primer complete all as specified & directed by Engineer Incharge.
24M & L Preparation of existingtreatment &applying thin layer of wall care putty andapplying two coatsof oil bound distemper on walls all asspecified and directed over a coat of primer complete all as specified & directed by Engineer Incharge.
25Preparation of old plastered surface of wall and apply three coat of white wash on ceilling complete all as specified & directed by Engineer Incharge.
26M & L Preparation of old surfacesof wall and apply two coat of cement base paint complete all as specified & directed by Engineer Incharge.
27S&F stainless steel plate rack made of 1.00 mm thick sheet grade SS- 304 of standard size 36"x36"x8" and of approved quality of finish all as specified and directed and of ISI mark. Make : Blue Star or equivalent complete all as specified & directed by Engineer Incharge.
28S & F in repairs stainless steel sink with drainage board made of stainless steel 1 mm thick with plugs washers and waste including bedding in cement mortor or including fixing cantilever brackets and connecting union to pipe overall size 915 mmx 460 mm bowl size 410 mm X 330mm X 160 mm complete all as specified & directed by Engineer Incharge.
29S&Fin repair chromium plated 15mm dia bib taps, cast copper alloy with crutchhandle, screwed down, screwed for iron pipes complete all as specified & directed by Engineer Incharge.
30S&F in repairfor chromium plated angular stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore of size 15mm complete all as specified & directed by Engineer Incharge.
31S & F in repairvitreous china washhand basin whiteflat back size 550x 400 excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP brass wastes coupling and other fittings all as specified & directed by Engineer Incharge.
32S&F in repair PVC flushing cistern low level 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc complete all as specified & directed by Engineer Incharge.
33S&F in repair chromium plated 15mm dia pillar taps , cast copper alloy with crutch or butterfly handle, screwed down, high pressure or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipescomplete all as specified & directed by Engineer Incharge.
34S&F in repairs mirror of size 600 x 450 thick bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified & directed by Engineer Incharge.
35S&F in repairs soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified & directed by Engineer Incharge.
36S&F in repairs towel rail 600 mm long of PTMT any colour for fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weght 190 gms) all as specified & directed by Engineer Incharge.
37S&F in repairs CP shower roses with or without swivel joints 125mm size, including fixing to steel pipe or union complete all as specified & directed by Engineer Incharge.
38M&L PVC (SWR) floor trap with steel grating 75 mm dia including jointing to waste pipe including removing old traps all as specified & directed by Engineer Incharge.
39Demolition and breaking of drain pipes AC/CI/PVC set in cement mortar or adhensive all as directed of dia 100 mm dia all as specified & directed by Engineer Incharge.
40S&F for 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints fixed to floor including clamp etc all as specified & directed by Engineer Incharge..
41S&F for 75 mm diaSWR pipes single socketed in any length with rubber ring joints fixed to wall including clamp etc all as specified & directed by Engineer Incharge..
42S&F for 75 mm diaSWR pipes single socketed in any length with rubber ring joints fixed to floor including clamp etc complete all as specified & directed by Engineer Incharge.
43S&F PVC (SWR) single T 75 mm dia with access door all as specified & directed by Engineer Incharge.
44S&F PVC (SWR) bend 75 mm dia all as specified & directed by Engineer Incharge.
45S&F PVC (SWR) 75 mm dia vent cowl all as specified & directed by Engineer Incharge.
46S&F in repair PVC 32 mm dia flush pipe suitable for low level cistern all as specified & directed by Engineer Incharge.
47S&FPVC Connection15 mm size with PTMT nuts of length 600 mm all as specified & directed by Engineer Incharge.
48Supply and fix in repairs vitreous china squatting pan Orissa pattern wash down water closet of size 580x440 mm, white, with integral foot rests complete fixed in repairs with P or S trap, and all necessary fittings etc complete all as specified & directed by Engineer Incharge..
49S&F in repair vitreous china pedestal pattern, white with including cast iron "P" or "S" trap andconnection to trap includintg cement concrete, seat cover and jet spray etc. including making good to floor, complete all as specified & directed by Engineer Incharge.
50S & F in repairs 15 mm chromium plated 2 way bib cock with wall flange confirming to CAT No. F2002161 of " Cera" or of equivalent make specified all as specified & directed by Engineer Incharge.
51S & F in repairs CP toilet paper holder conforming to CAT No. ACN-1151 N of "Jaquar" specified here in after all as specified & directed by Engineer Incharge.
52S & F in repairs Health faucet conforming to CAT No. ALD-573 as mentioned of make "Jaquar" or of equivalent all as specified & directed by Engineer Incharge.
53S&F15mm bore GI water tubing medium grade fixed including Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete to wall or ceiling as specified & directed by Engineer Incharge.
54S&F 20 mm bore GI water tubing medium grade fixed complete to wall or ceiling including Taking down GI tubing & connection 20mm dia laid in floor / trenches or fixed to walls as specified & directed by Engineer Incharge.
55M&L 20mm thick granite (of any type) work table rubbed and pre polished as in cooking platforms ,window cill,steps,wall cladding and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixtures of pigment to match with shade of granite complete and ensure best adhesion to surface including screed bed of 15mm thick in CM (1:6) for laying floor finishes complete all as specified & directed by Engineer Incharge.
56M&LMachine cut cudappah stone slab 20-25mm thick over cement screed base in 10mm thick CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including screed bed of 15mm thick in CM (1:6) for laying floor finishes all as specified & directed by Engineer Incharge.
57Rounding to edges of stone slabsone edge, such as in steps, cooking platform, and other similar situations all as specified & directed by Engineer Incharge.
58Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc. 1.50 Sqm and not. exc. 4Sqm. each all as specified & directed by Engineer Incharge.
59Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n exc. 1.50 Sqm each all as specified & directed by Engineer Incharge.
60Taking down Shutters of any description exc 1.0sqm and n exc 2.00 Sqmeachetc complete all as specified & directed by Engineer Incharge.
61Taking down Shutters of any description and refixing in same opening exc 1.0sqm and n exc 2.00 Sqm eachetc complete all as specified & directed by Engineer Incharge.
62M & Lfor 2 nd class hardwoodPlain, solid, straightchowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints,suppliedandfixed all as specified & directed by Engineer Incharge.
63S&F aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified & directed by Engineer Incharge.
64S&F three track sliding window with two or more shutter with 4mm thick tinted glass one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of "JINDAL" or of equivalent make complete all as specified and directed by Engr-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352 all as specified & directed by Engineer Incharge.
65S&F fixed glass louvered ventilators using 5mm thick pin headed glass and following aluminium powder coated sections conforming to catalogue of "JINDAL" or of equivalent make and rubber beading etc all as directed. (a) SP - 20048 (b) Glazing clips - 19352. complete all as specified and directed by Engineer-in-Charge.
66S&F in repair 18 mm thickMDF boardprelaminated both side with decorative choice lamination as in Office Cabinet, pelmate box,drawer, CB shutter etcfixed with screw including 6mm thick, 1st Class HW (TW) beading all around on edging to timber frame work all as specified and directed by Engr-in-Charge .
67S&F 35 mm thick glazed and skeleton shutter open rebated and prepared to receive glass, IInd class hardwood gauge etc edges of framing plain, chamfered or rounded fitted with cut and mitred stile as per beads for securing glass etc, The size of therail and site as per IS 1003 (part -I), Kiln seasoned and chemically presure treated as specified and directed by Engr in charge.
68Supply and fixing 4mm thick sheet glass ordinary quality andglazing fixed to aluminium window / ventilator shutters / steel windows etc all as specified & directed by Engineer Incharge.
69S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples .including fillet all as specified & directed by Engineer Incharge.
70S&F 35mm thick flush shutters, solid core onstruction, with block board core and plywood face panels, commercial type on both sides, one face is covered with decorative face veneer with lipping/frame to match complete all as specified & directed by Engineer Incharge.
71S&F butt hinges 100mm, medium weight complete all as specified & directed by Engineer Incharge.
72S&F 150 mm extruded aluminium alloy powder coated handles ,fabricated type ISI marked all as specified & directed by Engineer Incharge.
73S & F Aluminium anodised powder coated barrel tower bolt of extruded section 150mm long ISI marked all as specified and directed by Engineer Incharge.
74Supply & fixingaluminium alloy anodisedsliding door bolts with hasp and stapple (bolt type and fxing clips of sheet,cast or extruded section and fixing bolts and sliding bolts of extruded sectionof 250mm long ISI marked all as specified & directed by Engineer Incharge.
75M & L 75 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screwsall as specified & directed by Engineer Incharge.
76Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer all as specified & directed by Engineer Incharge.
77Preparation of Old or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint)all as specified & directed by Engineer Incharge.
78M&Lpreparation old paintedsteel surface of any description over 10 cm width or girth not other wise described and appying one coat of syntheticenamel paint all as specified & directed by Engineer Incharge.
79S&F curtain rod 20 mm dia decorative type powder coated aluminium section all as specified & directed by Engineer Incharge.
80S& F decarative type funnel/bracket to suit the curtain rod of 20 mm dia powder coated all as specified & directed by Engineer Incharge.
81S&F Factory madewood grain printed (Prelaminated) solid PVC single door frame of size 50 x 47 mm with a wall thickness of 5mmprelaminated colour sheet reinforced with 19 mm x 19mm MS square tube having wall thickness 19 guge complete all as shown in sketch on page 180 of SSR 2020 Part II complete all as specified & directed by Engineer Incharge.
82S&F factory made wood grain printed (Prelaminated) solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes 19 mm x 19 mm having wall thickness 19 gauge for stiles.MS tube 15mmx 15mm having wall thickness 19 mm gauge for top and bottom rails.MS frame shall be covered with 5mm thick heat moulded prelaminated colour PVC "C" channel having 5mm thick PVC sheet strip 20mm wide struck inside with solvent cement for stiles and 5mm thick PVC sheet for top rail, lock rail and bottom rail on either side and 10mm (5mm x 2mm) thick, 20mm wide cross PVC sheet as gap insert for top and bottom rail. Paneling of 5mm thickprelaminated colour PVC sheet to be fixed in MS frame welded/sealed to the stiles and rails with 5mm x 30 mm PVC sheet beading and jointed together with solventcement complete all as shown in drg give on page 177 of SSR 2020 part II.The width of stiles and rails shall be as specified in para 8B.2.1 on page 145 of SSR 2020 part II.Each PVC door shutter leaf consist of 4 Nos 100 mm long MSbutt hinges all as specified & directed by Engineer Incharge.
83Dismantling wrought iron or mild steel work of any description not otherwise provided all as specified & directed by Engineer Incharge.
84S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410 -W (GdeE- 250)all as specified & directed by Engineer Incharge.
85S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, door chowkats of angle or other section and similar works complete of Fe-290 Gde E-165 including welding etc all as specified & directed by Engineer Incharge.
86Dismantling of single layer manglore pattern tiles and ridge in roofing /AC sheet/GI Sheet roofing all as specified & directed by Engineer Incharge.
87Dismantling of fillets, rails, posts, rafters, purlins, etc.unframed workunder 40 sq. cm in section all as specified & directed by Engineer Incharge.
88Dismantling boarding,framing any description,and any size of framingfixed in any position with nails all as specified & directed by Engineer Incharge.
89Dismantling timber scantling of size 40 Sqcm and over in section as in unframed work all as specified & directed by Engineer Incharge.
90M&L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified & directed by Engineer Incharge.
91M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6all as specified & directed by Engineer Incharge.
92M & LIInd class softwood clean sawn batttens at 30 cm centres to centre of section area 15 & nexc 25 Sqm all as specified & directed by Engineer Incharge.
93Fixing onlyRoof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified & directed by Engineer Incharge.
94S& F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of an colourhaving tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified & directed by Engineer Incharge.
95S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /clading to wallfixed withself taping screws all as specified & directed by Engineer Incharge.
96M&L Rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Wind ties etc grade Fe-410-W Quality A (Grade-250) all as specified & directed by Engineer Incharge.
97S&F Megnetic catcher for cabinets all as specified & directed by Engineer Incharge.
98S&F in repair for stainless steel peg set of sixall as specified & directed by Engineer Incharge.
99M&Lpreparation new paintedsteel surface of any description over 10 cm width or girth not other wise described and appying two coat of syntheticenamel paint over a coat of primer complete all as specified & directed by Engineer Incharge.
100Dismantaling Wallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover filletetc complete all as specified & directed by Engineer Incharge.
101M&L for 8 mm thick one side laminated gypsum ceiling board for false ceiling of size 600 x600x mmonaluminium powder coated grid work 60 cm x 60 cm with using 36.5 mm x 23.5 mm x1.5 mm thick main tee, 23.5 x 23.5 mm x 1.28 cross tee and 25 x 25x 1.5 mm angles fixed to perimeter of wall for false ceiling including necessary supporting hanger with 4.0 mm dia GI wire and "J" bolts washer nuts for securing frame work to ceiling suspended @ 120 cm C/C both ways, size of grid shall be 605 x 605 mm, all as specified & directed by Engineer Incharge.
102Demolition of brick work or stone/boulder masonry,built in cement mortar all as specified & directed by Engineer Incharge.
103M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-5 and setting in CM 1:6 all as specified & directed by Engineer Incharge.
104Supply and fixedrotational moulded polyetylene water storage tanks (cylindrical vertical with closed top) of 500 Litres capacityhoisted and fixed in position and connecting up pipes and ball valve complete set of PTMT, securing access covers all as specified and directed including disconnecting existing water tank complete all as specified & directed by Engineer Incharge.
105Removing of existing old bitumenous tarfelt including cement screed bed and clean the surface with wire brush and washing with water to achieve the original surface of slab all as specified and directed.incl rubbish off outside of MD land all as specified & directed by Engineer Incharge.
106M & L water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge including floowing . (a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumnous primer @ 0.20kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyester, weighingnot less than 3.5 kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engineer Incharge.Carrying out test by flooding water for 24 hrs for leakagge & seepages and rectifyingthe same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminiumpaint @ 0.15 ltr/Sqm on the top of membranesurfaces complete all as specifed & as directed by Engr in Charge.
107M&L forPCC 1:2:4 type BO (using 12.5 mm graded crushed stone aggregate) as in PCC padding in roof kerbs or mud stops, rounded and chamfered on edgesand on chajjas laid over RCC surface fineshed even and smooth without using extra cement including necessary water proofing chemicals all as specified and directed by the Engr-in-charge. (Note: WPC shall be measured and paid separately)
108Spply only integral water proofing compound all as specified & directed by Engineer Incharge.
109Taking down old u/s point wiring( light/fan/socket/power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, pendants, regulators, light fittings etc. removing materials for taking credit and making good the disturbed surfaces of walls/floors/ceiling etc.complete all as specified & directed by Engineer Incharge.
110Taking downMain switches/DBs of any make and type including teakwood board, MCBs/MCCBs etc. complete and making good the disturbed surfaces including colour wash complete all as specified & directed by Engineer Incharge.
111Taking down old unserviceable/worn out sub main wiring of any type and size complete all as specified & directed by Engineer Incharge.
112Taking down fans, removing to workshop for servicing, cleaning, lubricating, spray painting one coat with synthetic enamel paint, writing MES No. replacement of split pin, rubber bush and other spare required if any including fixing PVC cable with stranded copper conductor of size 0.75 Sqmm and refixing the fans at the same locations complete for the following sizes.
113M&L for point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.5 Sq.mm (Nominal area) single core, PVC insulated and unsheathed stranded FRLScable 1100 volts grade, IS - 694 marked in PVC casing caping heavy duty ISI marked including all accessorieswith PVC modular boxes, modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-
114(a) One light point controlled by one, one way switch
115(b) One ceiling/Exhaust fan point controlled by one, one way switch andregulator.
116(c)One three pin 5 Amps socket outlet point controlled by one No one way switch on same board
117(d)One three pin 5 Amps socket outlet point controlled by one No one way switch on independent board
118(e) One bell point controlled by one switch
119All as per Item No. 5 above but with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 markedfor 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded FRLS copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly all as specified & directed by Engineer Incharge..
120S & F for Modular switch one way 6 A, 1 module complete all as specified & directed by Engineer Incharge.
121S & F for Modular switch one way 16 A, 1 module, with neon indicator complete all as specified & directed by Engineer Incharge.
122S & F for Modular socket, 6A - 2/3 pin combined 2 module complete all as specified & directed by Engineer Incharge.
123S & F for Modular socket, 6A/16A - 2/3 pin combined 2 module complete all as specified & directed by Engineer Incharge.
124S & F for celling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked complete all as specified & directed by Engineer Incharge.
125S & F for Modular stepped type fan regulator, 2 module complete all as specified & directed by Engineer Incharge.
126S & F for Bell,Multi Music complete all as specified & directed by Engineer Incharge.
127S & F for Modular Bell push 6 Amp, 1 module complete all as specified & directed by Engineer Incharge.
128S&F vertical 4 way TPN double door,recess mounted/wall mounted, MCCB as incomer and outgoing MCB SP/TPis 3 pole V-Tec of 100A rating & 16KA breaking capacity, MCCB is pre-fitted at factory & including price of MCCB, all as specified & directed by Engineer Incharge. ( Note : Empty space shall be covered by blanking plate and connect with lugs withoutany extra cost )
129S & F DB4 way TPN double door, recessed mounted/ wall mounted, MCB as incomer is 3 pole and neutral of 63 A rated capacity and 16KA breaking capacity all as specified & directed by Engineer Incharge.
130S & FMCB Four Pole rated capacity 63 amps, 430/440 V breaking capacity 10 KA ,C- curve complete all as specified & directed by Engineer Incharge.
131S & F for MCB DB SPN sheet metal enclosure, 8 way with 200 amps rated bus bar double door, fixed on wallgood to disturbed surfaces, and connecting with existing cable complete all as specified & directed by Engineer Incharge.
132S & F for MCB double pole ofrated capacity 32 amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified & directed by Engineer Incharge.
133S & Ffor MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified & directed by Engineer Incharge.
134M & Lfor Sub main wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid 20 mm PVC rigid , ISI marked and itsaccessories duly PVC conduit in wall/ roof / floor including one run of single core 4 sqmm PVC insulatedunsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/ main board complete all as specified & directed by Engineer Incharge.
135S & F lamp holder (angle/bracket) insulated body, with back plate for batten fittings including LED bulb of Cap8W 2 pin type complete for 230 V 50Hz AC supply complete all as specified & directed by Engineer Incharge.
136S&F in replacement of LED light fitting surface and wall mounted LED batten with Aluminium housing & integrated electronic driver complete in all respect of 10W cap. Cat Part No BCLSB 10 WHof make - Bajaj or equivalent in other approved makes all as specified & directed by Engineer Incharge.
137S&F LED security light in replacement ofluminaries 30 watt complete with all accessories andwall mounting bracket of suitable size including clamps, nut bolts etc. prewired Conforming to Havells Cat Part No. BCLST 30W LED Ior equivalent in other approved makes all as specified & directed by Engineer Incharge.
138Supply and fix LED Tube light fittings Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver 20 W LED complete including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable ofsuitable size from ceiling rose to connector. Conforming to Cat Part No.ENDURALINEARNEOBS20WLED865SPCWH all as specified & directed by Engineer Incharge.
139M&L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete (Note:-GI earth strip and protection pipe beyond 7.5m will be measured and paid separately) all as specified & directed by Engineer Incharge.