| 1 | Demolition of cement concretein ground floors including tile, terrazo tile and paving not exc 15 cmthickness(below or above ground level)unreinforced concrete complete all as directed. |
| 2 | Removing of salvage material / soil not exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as directed. |
| 3 | Demolition of cementconcrete of any description and in any position including plastering and leeping (whether full thickness including textile coverings, bitumen felt on roofs removed or only a part thereof) complete all as directed. |
| 4 | Roughening surfaces of old concrete roof / floorsurfaces by picking, sweeping clean and washing down with water to remove dust,etc complete all as directed. |
| 5 | M & L for Brushing neat cement slurry @ 3.0 kg of cement per square metre on old concrete surfaces complete all as specified and as directed. |
| 6 | M&L for40 mm averagethick PCC nominal mix 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) for roof treatment etc complete all as specified and as directed. |
| 7 | M&L forrendering 15 mm thick on fair faces of brick work / concrete surfaces in CM 1:3and rendering is to be finished even and smooth without using extra cement and mixing with liquidWPC as per manufacturers instructions complete all as specified and as directed.Note :- WPC will be measured and paid separately. |
| 8 | Supply OnlyLiquid water proofing compound to incorporate in above item complete all as specified and as directed. |
| 9 | M&L for Applying evenly a priming / tack coat of industrial bitumen 85 / 25 grade at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and as directed. |
| 10 | M&L for APP based polymeric membrane minimum weighing 3.0 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight. not less than 150 gms / sqm) laid on primed surfaces by forced application complete all as specified and as directed. |
| 11 | M&L for applying two coats of aluminium paint @ 0.1 ltr/Sqm per each coat complete all as specified and as directed. |
| 12 | M &L for30 mm thick PCC(1:2:4 )type B-0 mixusing 12.5 mm graded stone aggregate as in floors complete all as specified and as directed. |
| 13 | M&L for 20 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finishes complete all as specified and as directed. |
| 14 | M & L forMachine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and as directed. |
| 15 | M&L for rendering to stone masonry surfaces or surfaces other than fair faces of brick surfaces, 10 mm thick in cement mortar 1:4, scoured for fixing tiles / stone slabs in skirting / dados etc complete all as specified and as directed. |
| 16 | M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillars laid over cement screed and jointed in neat cement slurry complete all as specified and as directed. |
| 17 | Taking down chowkats or frames exc 1.5 Sq mtr and notexc 4 sqm each with shutters without taking off shutters from the frames complete all as specified and as directed. |
| 18 | M & L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring,eaning but built in cement mortarand stacking bricks, removing surplus serviceable bricks, hard core, etcto store and rubbish of the premises not exc50 mtr complete all as specified and as directed. |
| 19 | S & F 1.25 mm thick Mild steel, plain, black sheet in hearths; covering to door shutters including weldingetc complete all as specified and as directed. |
| 20 | S&F MS Angle/ flate iron/chanel framed work such as iron gate, ladder, SWTframe, grills, gratings, framed guard bars, hold fast ,incl necessary locking arrengement etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 21 | M & L for Cement concrete 1;2:4 type B-0 mix using 12.5 mm graded stone aggregate as in bed blocks for hold fast includingnecessary formwork complete all as specified and as directed. |
| 22 | M&L for preparing steel and iron surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide / zinc chrome primer complete all as specified and as directed. |
| 23 | S&F stainless steel wire mesh of size 20 mm and 1.4 mm diaincludingnecessary welding and anchoraging with iron frame for ventilator etc complete all as specified and as directed. |
| 24 | M&Lforhard core of broken stone of gauge n.exc 63 mm deposited spread and leveled in layers ,water and rammed true surfacein plinth protection / hard standing complete all as specified and as directed. |
| 25 | M&L for 100 mm thick PCC1:4:8 type D-2 mix(using 40 mm graded stone aggregate) laid in floor sub base and finished cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 26 | M&L for 40 mm thick cement concrete 1 : 2 : 4 type B-1 mix (using 20 mm graded crushed stone aggregate) laid in base, floors and finished cement concrete surface even and smooth with out using extra cement complete all as specified and as directed. |
| 27 | M&L for glass dividing strips 3 mm thck and 38 mm width inserted in position and confirming to design complete all as specified and as directed. |
| 28 | M&L for sand fillingincluding levellingand consolidationcomplete all as specified and as directed |
| 29 | Taking down cement plaster on brickor stone walls / ceilings etc including raking out joints , hacking for key andscrubbing down with water etc complete all as specified and as directed. |
| 30 | Complete removal of existing treatment from walls including scrapping and removing the entire scales of existing treatment complete all as specified and as directed. |
| 31 | Description all as per Seritem No 30 above but on ceilings complete all as specified and as directed. |
| 32 | M &Lforrendering 10 mm thick in CM 1:3 oncelling surfaces and rendering is to befinished even and smooth with out using extra cementcomplete all as specified and as directed. |
| 33 | M &L forrendering 15 mm thick in CM 1:6 onbrick massonry surfaces of walls and rendering is to be finished even and smooth with out using extra cementcomplete all as specified and as directed. |
| 34 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of brickwork or concrete surfaces andfinished fair and even complete all as specified and as directed. |
| 35 | M&L for Applying 3 mm thick wall care putty on wall surfaces complete smooth finishing, rubbing with paper in two layers each not exc 2 mm thick complete all as specified and as directed |
| 36 | M&L for preparation of surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces of ceilings complete all as specified and as directed. |
| 37 | M&L for applying two coats of oil bound distemper on surfaces of walls over a coat of chalk whiting primer including preparation of surfaces complete all as specified and as directed. |
| 38 | M & L for preparing old surfaces, including cornices and applying two coat of white wash on cellings complete all as specified and as directed. |
| 39 | M&L for applying one coat of oil bound distemper on surfaces of walls including preparation of old surfaces complete all as specified and as directed. |
| 40 | M & L forpreparing new surfaces, including cornices and applying three coats of white wash on celling surfaces complete all as specified and as directed. |
| 41 | M&L for providing cement concrete PCC 1:3:6 as in roof kerbs or mudstops and plinth protection rounded or chamfered on edges (type C-1 mixusing 20 mm graded stone aggregate) complete all as specified and as directed. |
| 42 | M&L for applyingtwo coats of cement based painton surfaces of walls including preparation of surfaces complete all as specified and as directed. |
| 43 | M&L for preparation of old wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coatof synthetic enamel paint (Ordinary tint) complete all as specified and as directed. |
| 44 | M&L for preparing old steel and iron surfaces of any description over 10 cm widthor girth and applying one coatof synthetic enamel paintcomplete all as specified and as directed. |