| 1 | Earth work in surface excavations not exceeding 30 cm. in depth but exceeding 1.5 metre in width as well as 10 sqm on plan including disposal of excavated earth upto 50 Mtr. And lift upto 1.5 Mtr. Disposed soil to be leveled and neatly dressed: All kinds of soil. |
| 2 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. All kinds of soil. |
| 3 | Providing and laying in position cement concrete including curing compaction etc . Completein specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate,1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Random rubble dry stone kharanja under floor |
| 5 | Random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm thick wall in:Cement mortar 1:6( 1 Cement : 6 Sand ) |
| 6 | Brick masonary in foundation and plinthwith bricks of class designation 75 in Cement mortar 1:6 ( 1 cement : 6 coarse sand ) |
| 7 | Half brick masonry in superstructure up to third storey including cost of nominal hoopreinforcement ( 2 Nos. 6 mm dia M.S. bar at every forth course )using bricks of designation 75 Cement mortar 1:4 ( 1 cement : 4 coarse sand ) |
| 8 | Providing and fixing precast cement concrete coping 1:2:4 mix 50 mm thick complete as per specification: |
| 9 | Add Extra over item for brick work in Square or Rectangular Pillars Up to 45 cm length and two corners are free |
| 10 | Providing and fixing welded mesh/expanded metalmesh in frame work, flat iron beading 20x3 mm including top cross laps inside and out sides welding, iron bolts, screws, clips etc. complete (excluding frame work) of size. Welded mesh 50x50mmx16 gauge. |
| 11 | Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr heightIn flates, tees, angles & Channals |
| 12 | Providing corrugated G.I. sheet roofing fixed with G.I. J or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete (upto a pitch of 60 degree) & excluding the cost of purlins rafters and truses, for class of sheets. 0.60mm thick |
| 13 | Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar 1:4:Up to 15 cm thick |
| 14 | Plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish: 20mm thick |
| 15 | Finishing with neat cement (punning) |
| 16 | Providing and laying in position cement concrete including curing compaction etc . Completein specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate M20 grade Nominal Mix (with graded stone aggregate 20mm nominal size) |
| 17 | Providing and fixing 30 to 40 mm thick stone chajjas in cement sand mortar 1:4including making gola at junction with wall in cement concrete M-15 grade (1:2:4 nominal mix) drip course.20 mm thick plastering in CM 1:6 on both faces |
| 18 | Polished Blue Kota stone flooring skirting laid over 20mm thick base of CM 1:4 and jointed with gray cement slurry to match the shade of the slab including rubbing and polishing complete For area of each slab From2001Sq.cm to 5000 sq.cm |
| 19 | Making grooves as per design in plaster 10mm to 20mm wide |
| 20 | Providing and fixing Ist quality standard White/ ivory,grey, fuma red brown, light green, light blue and other light shades Glazed Tiles of (confirming to IS : 13753 & IS 13622) of size 300 mm x 200 mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls & pillars ). |
| 21 | Providing and fixing T-iron frames for doors windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs, 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 22 | Providing and fixing M.S. sheet single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally bracked with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engineer-in-charge but excluding cost of chowkhats: including two coats of anti-corrosive red oxide primer paint. |
| 23 | Add extra for double leaf shutters. |
| 24 | Filling available excavated earth (excluding rock) in trenches plinth side of foundation etc. in layers not exceeding 20 cm in depth consolidation each deposited layer by ramming and watering including lead up to 50 mtr and with all lift. |
| 25 | White washing with whiting to give an even shade including all scaffolding New work (three or more coats) |
| 26 | P & F GI pipes ( Internal works ) with GI fittings excluding Union(IS:1239 mark) and MS clamps, including cutting and making good the wall and floors.15mm dia Nominal Bore \"\"B\" Class |
| 27 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore. |
| 28 | Painting with enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |