Military Engineer Services-MES has published Repair Maintenance Of Extrnl Water Supply Distbn System Upto And Incl Water Meter In Kadmbavanam Core Area Inclu Fire Hydrant System In Patanjali Nsry Little Binaga Kamath Bay Baithkol Cmplx Including Fire Alarm System At Core Area At Naval Base Karwar. Submission Date for this Tender is 19-10-2022. Alarm Systems Tenders in South Goa Goa. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SCH "A" PART-II (ROUTINE MAINTENANCE OF WATER SUPPLY DISTRIBUTIONSYSTEM AND FIRE HYDRANT) |
2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/loose soil for laying/taking out GI pipe line complete all as specified and as directed. |
3 | Returning, filling in including spreading,levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed. |
4 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
5 | Taking out old unserviceable GI tubing with all fittings from trenches, walls, floors etc of following sizes complete all as specified and as directed:- Note : Excavation & earth work will be measured & paid seperately under respective item of sch"A" |
6 | a) 100 mm bore |
7 | b) 80 mm bore |
8 | c) 50 mm bore |
9 | d) 40 mm bore |
10 | e) 25 mm bore |
11 | Laying only in new or old position in walls and floors GI tubing obtained from item No 4 (c) to 4 (e) here-in-before including cleaning of pipe including replacement of unserviceable fittings such as bends, elbwos, tees, sockets etc complete all as specified and as directed of following size:- Note:-Fittings required shall be provided by the contractor. Unit rate quoted shall be deemed to include for the same |
12 | (a) 50 mm bore |
13 | (b) 40 mm bore |
14 | (c) 25 mm bore |
15 | Laying only in new or old position in trenches GI tubing obtained from item No 4 (a) to 4 (d) here-in-before including cleaning of pipe including replacement of unserviceable fittings such as bends, elbwos, tees, sockets etc complete all as specified and as directed of following size:- Note :-1. Fittings required shall be provided by the contractor. Unit rate quoted shall be deemed to include for the same 2. Excavation & earth work will be measured & paid seperately under respective item of sch"A"). |
16 | a) 100 mm bore |
17 | b) 80 mm dia bore |
18 | c) 50 mm bore |
19 | d) 40 mm bore |
20 | Supply and fix GI tubing medium grade galvanized with all fittings and laid in walls, roof, ceiling or laid in floors etc. complete all as specified and as directed for the following sizes:- |
21 | a) 50 mm bore |
22 | b) 40 mm bore |
23 | c) 25 mm bore |
24 | Supply and fix GI tubing medium grade galvanized with all fittings and laid in complete all as specified and as directed for the following sizes :- Note : Excavation & earth work will be measured & paid seperately under respective item of sch"A". |
25 | a) 100 mm bore |
26 | b) 80 mm dia bore |
27 | c) 50 mm bore |
28 | d) 40 mm bore |
29 | Taking out old unserviceable PVC/UPVC/CPVC pipe with all fittings from ceiling/walls/floors etc of following sizes complete all as specified and as directed:- |
30 | (a) 50 mm bore |
31 | (b) 40 mm bore |
32 | (c) 25 mm bore |
33 | Supply and laying of CPVC pipe SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trench complete all as specified and as directed for the following sizes :- |
34 | (a) 50 mm bore |
35 | (b) 40 mm bore |
36 | (c) 25 mm bore |
37 | Supply and fix in repairs gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipe of the following sizes complete all as specified and as directed:- |
38 | (a) 50 mm bore |
39 | (b) 40 mm bore |
40 | (c) 25 mm bore |
41 | Supply and fix in repairs ball valve high pressure of PTMT with epoxy coated aluminium/stainless steel rod & high density plastic ball screwed for iron pipe of 25 mm bore (Minimum weight- 455 gms) complete all as specified and as directed. |
42 | M&L for removing all scale and dirt etc from RCC tanks and from mouths of circulating pipes etc and cleaning tank by using sodium hyphochloride gel to remove bacteria etc including cost of writing letters as "Tank cleaned on (____ Date)" using synthetic enamel paint out side the wall of RCC water tanks 1000 litres capacity complete all as specified and as directed. |
43 | M&L for removing all scale and dirt etcfrom PVC tanks and from mouths of circulating pipes etc and cleaning tank by using sodium hyphochloride gelto remove bacteria etc including cost of writing letters "Tank cleaned on (____ Date)" using synthetic enamel paint out side the tank of PVC water tanks 500 litres capacity complete all as specified and as directed. |
44 | All as per Item No 14 here-in-before but of capacity 1000 ltr complete. |
45 | S&F in repairs rotational moulded polythyne water storage tank, tripple layered, dust proof with ISI marked black/white colour (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 500 ltrs including dismantling the existing one all as directed. |
46 | All as per Item No 16 here-in-before but capacity 1000 litres complete all as specified and as directed. |
47 | S&F in repairs PVC water tank cover of existing make suitable for 1000 ltrs capacity with fixing PVC hinges, bolts & locking arrangement etc complete all as specified and as directed. |
48 | Disconnecting over head PVC service tank connections of any capacity such as inlet pipe/outlet/overflow pipe connections of any size 25 to 50 mm, repairs to leakage of tank through inlet/outlet connections by cutting the over size hole and material and labour for GI pipe fittings such as GI nipple, unions, sockets, reducers, check nuts etc. of size 25 to 50 mm including rubber/fiber packing reconnecting, positioned the tank in its positions complete all as specified and as directed. |
49 | M&L for repair to fire hydrant valves of size 63/80/100 mm dia and shifting at civil workshop by transport, opening up the defective valves and taking out spindle and gate from sluice valve and removing the old threads by grinding and making a new threads by brass welding, turning & polishing to the spindle at civil workshop on grinding machine as per original threads and refixing the same at position and testing complete all as specified and as directed. |
50 | Taking out old unserviceable HDPE pipe with all fittings from trenches or above ground level of following sizes complete all as specified and as directed:- Note : Excavation & earth work will be measured & paid seperately under respective item of sch"A". |
51 | a) 75/80 mm dia bore |
52 | b)100/110 mm dia bore |
53 | c)150 mm dia bore |
54 | Laying only HDPE pipe in new or old position, including jointing materials as per site requirement obtained from item No 29 (a) to 29 (c) including cleaning of following sizes complete all as specified and as directed :- Note : Excavation & earth work will be measured & paid seperately under respective item of sch"A". |
55 | a) 75/80 mm dia bore |
56 | b)100/110 mm dia bore |
57 | c)150 mm dia bore |
58 | Supply, laying, fixing and testing HDPE pipes PN-10 including jointing materials in trenches complete all as specified and as directed for the following sizes :- Note : Excavation & earth work will be measured & paid seperately under respective item of sch"A". |
59 | a)75/80 mm dia bore |
60 | b) 100/110 mm bore |
61 | c) 150 mm bore |
62 | Taking out old unserviceable DI/CI pipe with all fittings from trenches or above ground level of following sizes complete all as specified and as directed:- |
63 | a)100 mm dia bore |
64 | b)150 mm dia bore |
65 | c)200 mm dia bore |
66 | d) 250 mm dia bore. |
67 | e) 300 mm dia bore. |
68 | Laying only DI/CI pipe new or old position obtained from item No 33 (a) to (d) including cleaning of following sizes complete all as specified and as directed :- |
69 | a)100 mm dia bore |
70 | b)150 mm dia bore. |
71 | c)200 mm dia bore. |
72 | d) 250 mm dia bore. |
73 | e) 300 mm dia bore. |
74 | Supply, laying and testing ductile iron tubing class K-7 with all fittings in trenches all as specified and directed for the following sizes complete all as specified and as directed :- |
75 | a)100 mm dia bore |
76 | b) 150 mm dia bore. |
77 | c) 200 mm dia bore. |
78 | d) 250 mm dia bore. |
79 | e) 300 mm dia bore. |
80 | M&L for bends any type (radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces single branch, "Y" junction, double branch, cross, collars, caps and plugs all ends flanged/sockets or socket and spigot upto 300 mm dia bore complete all as specified and as directed. |
81 | M&L for rubber gasket joints with all jointing materials complete all as specified and as directed for the following sizes:- |
82 | (a)80 mm bore. |
83 | (b) 100 mm bore. |
84 | (c) 150 mm bore. |
85 | (d) 200 mm dia bore. |
86 | (e) 250 mm dia bore. |
87 | (f)300 mm dia bore. |
88 | M&L for lead wool joints with all jointing materials like lead wool & spun yarn complete all as specified and as directed for the following sizes:- |
89 | (a)80 mm bore. |
90 | (b) 100 mm bore. |
91 | (c) 150 mm bore. |
92 | (d) 200 mm dia bore. |
93 | (e) 250 mm dia bore. |
94 | (f)300 mm dia bore. |
95 | Labour only for breaking reinforced cement concrete chajja or conopy or similar items like cement water storage tank etc not exceeding 12 cm thickness for removing rusted GI pipe of any size and making good etc complete all as specified and as directed. |
96 | S&F in repairs mild steel nuts & bolts, washer flange etc complete all as specified and as directed. |
97 | Supply only lubricating oil of grade 220 complete all as specified and as directed. |
98 | Supply only grease for pump bearings complete all as specified and as directed. |
99 | M&L for preparation of existing painted surfaces of fire hydrentat any area includingfilling of cavities etc and applying one coat of synthetic enamel paint using spray gun/machine as per colour code including writing hydrent No on fire hydrent etc complete all as specified and as directed. |
100 | M&L for preparation of existing painted surfaces of motor, pump, water pipe lines etc at Baithkol pump houseand filling of cavities etc and applying one coat of synthetic enamel paint using spray gun/machine as per colour code including writing SM & MES No on pump & motor, indication marking etc complete all as specified and as directed. |
101 | Supply and fixing in repair canvas hose of lenght of 15 Mtr with SS Male and female coupling of size 63/80/100mm dia with GI Binding complete all as specified and as directed. |
102 | S&F in repairs battery charging system meant for charging 12 Volts, 65/180 AHcomplete all as specified and as directed. |
103 | S&F in repairs bearing No : 6310 2Zcomplete all as specified and as directed. |
104 | S&F in repairs bearing No : 6210 2Zcomplete all as specified and as directed. |
105 | S&F in repairs gland packing for pump of size 3 HP to 150 HP as per site requirement complete all as specified and as directed. |
106 | Dismantingand taking out carefully defective spindle from sluice valve of size 80 mm dia and removing the old gatestud by grinding and making it to a shape by brass welding and turning & polishing, greasing, servicing as per original gate stud and refixing the same at position and testing complete all as specified and as directed. |
107 | All as per Item No 41 here-in-before but of size 100 mm dia complete all as specified and as directed. |
108 | All as per Item No 41 here-in-before but of size 150 mm dia complete all as specified and as directed. |
109 | All as per item No 41 here-in-before but size 200 mm dia complete all as specified and as directed |
110 | All as per item No 41 here-in-before but size 250 mm dia complete all as specified and as directed |
111 | All as per item No 41 here-in-before but size 300 mm dia complete all as specified and as directed |
112 | M&L dismantling old unserviceable sump pump set 0.5 HP any type, Supply, installation, testing and commissioning sump pump set, electric driven of capacity 0.5 HP, Single Phase 230 Volts, 50 Hz, Head 23 Mtr, Suction size - 25 mm and delivery size - 25 mm, self primping, CI impeller and CI body complete all as specified and as directed. Note : Old pump to be deposited to MES store. |
113 | Supply and fix in repairs contactor 38 Amps, 3 Pole suitable for switching electrical power circuit as per site requirement complete all as specified and as directed.. |
114 | S&F in repairs cast iron sluice valve of size 80 mm flanged PN-1.6ISI conforming to IS :14846 hand wheel operated, stainless steel stem with gun metal parts flanged driller to IS: 1538 non rising stem PN-1.6 complete all as specified and as directed. |
115 | All as per Item No 49 here-in-before but of size 100 mm dia complete all as specified and as directed. |
116 | All as per Item No 49 here-in-before but of size 150 mm dia complete all as specified and as directed. |
117 | All as per Item No 49 here-in-before but of size 200 mm dia complete all as specified and as directed. |
118 | All as per Item No 48 here-in-before but of size 250 mm dia complete all as specified and as directed. |
119 | All as per Item No 49 here-in-before but of size 300 mm dia complete all as specified and as directed. |
120 | S&F in repairs water pressure gauge dial type of range 0-12 Kg/Sqcm complete all as specified and as directed. |
121 | S&F in repairs water pressure gauge dial type of range 0-16 Kg/Sqcm complete all as specified and as directed. |
122 | Dismantling electric motor from the centrifugal pumpset/compressor of any make, 3 phase 415V of following capacities, opening the motor for rewinding using super enamelled copper wire of suitable gauge to match with the existing winding including varnishing & drying and re-assemblingthe motor, connecting with pumpset with proper alignment and testing complete through authorised service engineer complete all as specified and as directed of following capacity :- |
123 | (a)1.5 HP |
124 | (b) 3 HP |
125 | (c)5 HP |
126 | (d) 7.5 HP |
127 | (e) 15 HP |
128 | (f)30 HP |
129 | (g) 60 HP |
130 | (h) 75 HP |
131 | (j) 150 HP |
132 | M&L for overhauling of centrifugal pump sets / vertical turbine pumps 3 phase 415 volts of following capacities byopening up the pumpset, cleaning inside & out side thoroughly,including replacement of gland packing, rubber insertion,replacement of bearings - 2 Nos (DE/NDE) and testing complete all as specified and as directed of following capacity :- |
133 | (a)1.5 HP |
134 | (b) 3 HP |
135 | (c)5 HP |
136 | (d) 7.5 HP |
137 | (e) 15 HP |
138 | (f)30 HP |
139 | (g) 60 HP |
140 | (h) 75 HP |
141 | (j) 150 HP |
142 | Supply only chemical resistant rubber pipe of size 15 mm dia complete all as specified and as directed. |
143 | S&F in repairs MCB TPN,40 to 100Amps, ""C"" series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and as directed. |
144 | S&F in repairs MCB SPN, 6 to 32 Amps, ""C"" series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and as directed. |
145 | S&F in repair MCCB 400 Amps 3 Pole 50 KA breaking capacity, 415 volts AC with adjustable thermal magnetic release complete all as specified and as directed. |
146 | S&F in repair MCCB 250 Amps 3 Pole 36 KA breaking capacity, 415 volts AC with adjustable thermal magnetic release complete all as specified and as directed. |
147 | S&F in repairs HRC fuse links 250 Amps, DIN type, 80 KA, 500V, AC, 50 Hz, Size 1 complete all as specified and as directed. |
148 | S&F in repairs HRC fuse links 125 Amps, DIN type, 80 KA, 500V, AC, 50 Hz, Size 00 complete all as specified and as directed. |
149 | S&F in repairs HRC fuse links 100 Amps, DIN type, 80 KA, 500V, AC, 50 Hz, Size 00 complete all as specified and as directed. |
150 | S&F in repairs HRC fuse links 2 Amps to 16 Amps, 80 KA, 500V, AC, 50 Hz, FGN complete all as specified and as directed. |
151 | S&F in repairs cast iron wafer type butterfly valve size 200 mm without lugs, gear operated, stainless steel grade 304 disc, Nitrile/EPDMrubber lining test pressure PN-10/PN16 complete all as specified and as directed. |
152 | All as per item No 68 here-in-before but size 150 mm dia complete all as specified and as directed. |
153 | All as per item No 68 here-in-before but size 100 mm dia complete all as specified and as directed. |
154 | All as per item No 68 here-in-before but size 80 mm dia complete all as specified and as directed. |
155 | S&F in repairs of oil filter suitable for Diesel Engine 72 HP complete all as specified and as directed. |
156 | S&F in repairs of fuel filter suitable for Diesel Engine 72 HP complete all as specified and as directed. |
157 | S&F in repairs following spare partes suitable for Diesel Engine 72 HPcomplete all as specified and as directed. |
158 | (a) V-belt |
159 | (b) Hose clamp |
160 | S&F in repairs of heating element suitable for solar water heater of capacity 500 LPD, electric power backup including minor repairs like replacement of gasket, checking of electric connection and minor leakage of water etc as per site requirement complete all as specified and as directed. |
161 | S&F in repair 80 mm dia water meter CI body flanged and drilled both ends confirming to IS 2373/81 mechanical driven straight reading incl 80 mm dia CI stainer complete all as specified and as directed. |
162 | M&L dismantling old unserviceable 200 mm dia water meter CI body flanged and drilled both ends with stainer,supply and fixing newwater meter 200 mm dia CI body flanged and drilled both ends confirming to IS 2373/81 mechanical driven straight reading incl 200 mm dia CI stainer and testing complete all as specified and as directed. |
163 | M&L for cleaning the pressure sand filters following capacity installed at various pump house at Naval Base Karwar by opening up the inspection covers, removing the existing filter media, cleaning thoroughly and refilling the same and toping up the deficient filter media of required quantity and fixing back the covers including replacement of existing unserviceable rubber gasket complete all as specified and as directed. |
164 | (a) 30 Cum/Hr |
165 | (b) 300 Cum/Hr |
166 | Supply only granular fine pebbles suitable for filter media of pressure sand water filters installed at various pump house at Naval Base Karwar, granular fine pebbles should be free from all types of salts, alkaline materials, minerals, silts, impurities etc complete all as specified and as directed. |
167 | Supply only quartz coarse sand suitable for filter media of pressure sand water filters installed at various pump house at Naval Base Karwar, quartz coarse sand should be free from all types of salts, alkaline materials, minerals, silts, impurities etc complete all as specified and as directed. |
168 | M&L for taking sample of water from any pump house/selected area at Naval Base Karwar and send it to any govt approved lab for carryout the following test periodically or required basis and test report to be produce to Engr-in-Charge complete all as specified and as directed :- |
169 | (a)Appearance (b)Colour (c)Odour(d) pH(e) Turbidity (NTU) (f) Total Dissolved Solids(g)Total Hardness as CaCO3(h)Calcium as Ca++(j)Total Alkalinity as CaCO3 (Methyl Orange) (k)Chlorides as Cl- (l) Sulphateas SO4-- (m)Nitrates as NO3- (n)Nitrite as NO2-(p)Oxidability - 4 hrs(q) Iron as Fe++ (r)Manganese as Mn++(s) Magnesium as Mg++(t) E, Coil or thermo tolerant (Coil from bacteria) |
170 | Taking down old unserviceable chemical dosing pump 0.5 HP of any type from any pump house and supply, installation and testing of new heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 kg /cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembly with agitator in one motor , agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV complete all as specified and as directed. Model No:- SSAPS/CDSPT/25. Note : Old pump to be deposited to MES store. |
171 | S&F in repair 3 Phase DOL starter for Dosing Pump suitable for Model SSAPS/CDSPT/25 made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, single phase preventor, High voltage low voltage protection complete all as specified and as directed. |
172 | S&F in repairs Single Outlet Landing valve (Hydrant Valve) of size 63 mm dia of Straight/Right Angle/Turn Down type made out of gun metal, flanged type, conforming to IS : 5290 along woth cast iron hand wheel operated, female instantaneous outlet, ABS Blank cap and chaincomplete all as specified and as directed. |
173 | S&F in repairs hand wheel made out of cast iron , suitable for sluice valve of size 80 to 150 mm complete all as specified and as directed. |
174 | S&F in repairs hand wheel made out of cast iron, suitable for sluice valve of size 200 to 300 mm complete all as specified and as directed. |
175 | S&F in repairs 3 - way Inlet Breeching, gun metal body having 3 gun metal, 63 mm male instantaneous inlets, fitted with non- return valves with gun metal drain valves, 3 rubber blank caps and chain complete all as specified and as directed. |
176 | S&F in repairs 2 - way Inlet Breeching, gun metal body having 2 gun metal, 63 mm male instantaneous inlets, fitted with non- return valves with gun metal drain valves, 2 rubber blank caps and chain complete all as specified and as directed. |
177 | S&F in repairs water monitor 2.5"gun metal body, 63 mm male instantaneous inlets, rubber blank caps and chain complete all as specified and as directed. |
178 | S&F in repairs rubber seal, blank caps and chain for fire hydrant of any size complete all as specified and as directed. |
179 | S&F in repairs hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete complete all as specified and as directed. |
180 | S&F in repairs aluminium strip 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down onductors above ground complete all as specified and as directed. |
181 | Supply and fixing in repair PVC suction hose of size 50mm dia, with hose clamp complete all as specified and as directed. |
182 | Supply and fixing in repair PVC suction hose of size 80mm dia, with hose clamp complete all as specified and as directed. |
183 | S&F in repairs cast iron Non return valve of size 100 mm flanged PN-1.6ISI conforming to IS : 5312 swing type with nitrile rubber flap flanged end to IS: 1538complete all as specified and as directed. |
184 | All as per item No 95 here-in-before but size 150 mm dia complete all as specified and as directed. |
185 | All as per item No 95 here-in-before but size 200 mm dia complete all as specified and as directed. |
186 | All as per item No 95 here-in-before but size 300 mm dia complete all as specified and as directed. |
187 | S&F in repairs bearing No : 6311 ZZcomplete all as specified and as directed. |
188 | S&F in repairs bearing No : 6313 complete all as specified and as directed. |
189 | S&F in repairs bearing No : 6209-2RS complete all as specified and as directed. |
190 | S&F in repairs cast iron wafer type butterfly valve size 300 mm without lugs, gear operated, stainless steel grade 304 disc, Nitrile/EPDMrubber lining test pressure PN-1.0/PN1.6 complete all as specified and as directed. |
191 | Supply and fixing MS sheet of size 173cm x 127cm x 6mm including dismantling the old unsv MS sheet complete all as specified and as directed. |
192 | S&F in repairs of new battery of 12 volts 65 AH battery complete all as specified and as directed. |
193 | S&F in repairs bearing No : 6205-ZZ complete all as specified and as directed. |
194 | S&F in repairs of new battery of 12 volts 180 AH battery complete all as specified and as directed. |
195 | M&L for cleaning the strainerfilter of size of 0.18 CUM including replacement of strainerat any pump house complete all as specified and as directed. |
196 | Supply and fixing in repair float type level indicator, Range up to 9 Mtr complete all as specified and as directed. |
197 | M&L for preparation of existing painted surfaces offire hose boxes etc at any area includingfilling of cavities etc and applying one coat of synthetic enamel paint using spray gun/machine as per colour code including writing hydrent No on fire boxes etc complete all as specified and as directed. |
198 | M&L for preparation of existing painted surfaces of motor, pump, water pipe lines etc at RDS pump houseand filling of cavities etc and applying one coat of synthetic enamel paint using spray gun/machine as per colour code including writing SM & MES No on pump & motor, indication marking etc complete all as specified and as directed. |
199 | PART-III :ROUTINE MAINT OF FIRE ALARM SYSTEM |
200 | Supply , installation , testing & commissioning in repairsof single Loop card for EST-3 Fire Alarm Panel complete all as specified and as directed. |
201 | Supply & installation in repairs of Addressable Smoke detector along with required accessories complete all as specified and as directed. |
202 | Supply & installationin repairs of Addressable Heat detector along with required accessories complete all as specified and as directed. |
203 | Supply & installation in repiars of Addressable Multi Sensor detector along with required accessories complete all as specified and as directed. |
204 | Supply & installation in repairs of Addressable Isolator Module along with required accessories complete all as specified and as directed. |
205 | Supply & installationin repairs of Addressable Control Module along with required accessories complete all as specified and as directed. |
206 | Supply & installation in repairs of Addressable Sounder cum strobe along with required accessories complete all as specified and as directed. |
207 | Supply & installationin repairs of Addressable Manual Call Point along with required accessories complete all as specified and as directed. |
208 | Supply & Laying in repairs of 2 Core 1.5 Sq mm Copper Flexible Cable for control wiring with & including copper lugs, connectors etc complete all as specified and as directed. |
209 | Supply & Laying in repairs of 25 mm MS pipe along with required accessories complete all as specified and as directed. |
210 | Labour only for Non Comprehensive Routine maintenance checkup of Fire alarm system"s error and alarms, necessary inspection of the Fire alarm system and take necessary corrected actions,resolve any issues regarding the system and take corrective actions for the problems , check connectivity and communication at all terminations,check all power sources and outlets used in the system complete for 12 Nos panels of Fire alarm system by authorised service engineer of OEM and furnish the report complete all as specified and as directed. |
211 | Supply & Fix in repairs lead acid typebattery of 12 Volts 7 AH capacity complete all as specified and as directed. |
212 | Supply and installation in repair of network card of Fire Alarm control panel complete all as specified and as directed. |
213 | Supply and installation in repair of Power supply of Fire Alarm control panel complete all as specified and as directed. |
214 | Supply and installation inrepair of Display of Fire Alarm control panel complete all as specified and as directed. |
215 | Supply and installation in repair of loop card of Fire Alarm control panel complete all as specified and as directed. |
216 | Supply and installation inrepair of mother board of Fire Alarm control panel complete all as specified and as directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy