Repair To Joinery Roofing Leakage Seepage Flooring And Repair To Md Accn Of Offr And Pbor Accn At Dhangu And Nanavati Complex Area Under Ge South Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Repair To Joinery Roofing Leakage Seepage Flooring And Repair To Md Accn Of Offr And Pbor Accn At Dhangu And Nanavati Complex Area Under Ge South Pathankot. Submission Date for this Tender is 18-10-2022. Building Work Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

34007879
Corrigendum : Repair To Joinery Roofing Leakage Seepage Flooring And Repair To Md Accn Of Offr And Pbor Accn At Dhangu And Nanavati Complex Area Under Ge South Pathankot
Open Tender
Indian
Punjab
pathankot
18-10-2022

Tender Details

Repair To Joinery Roofing Leakage Seepage Flooring And Repair To Md Accn Of Offr And Pbor Accn At Dhangu And Nanavati Complex Area Under Ge South Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Sep-2022 BOQ REVISED BOQ 11-10-2022
2 11-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR TO JOINERY, ROOFING, LEAKAGE SEEPAGE, FLOORING AND REPAIR TO MD ACCN OF OFFR & PBOR ACCN AT DHANGU & NANAVATI COMPLEX AREAUNDER GE(SOUTH) PATHANKOT.
Sl. No. Item Description
1Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
2M&L for brick work in cement mortar 1:4 of old size sub class ‘B" bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed.
3All as per Item 2 above but except bricks complete all as specified and directed
4M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wallsbuilt in cement mortar 1:4 complete all as specified and directed.
5M&L for15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cementincludingtwo coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat complete all as specified and directed.complete all as specified and directed
6M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. all as specified.
7Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC complete all as specified and directed.
8Complete all as per item 7 abve but area exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed.
9Taking down shutters of any description exc 1.00 sqm and not exc 2.00 Sqm each complete all as specified and directed.
10Taking down shutters of any description not exc 1 sqm each and removingfrom site complete all as specified and directed.
11S&F pressed steel frame for door made out of MS sheet 1.25mm thick of size 105mmx60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etccomplete all as specified and directed.
12S&F pressed steel frame for doors made out of MS sheet 1.25mm thick of size 125mmx60mm for with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed.
13S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
14S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
15M & L for cement concrete type C-0, 1:3:6 using 12.5 mm graded crushed stone aggregate as in back filling ofhollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed.
16S&F steel window/ventilator with tubular frame factory made double shutters of size 79mm x 39mm, 16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl projecting type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 75 mm long and 10mm square bar grills complete, includingtwo coats of synthetic enamel paint over one coat of red oxide primer includingsufficient nos of PCC bed blocks in pcc 1:2:4 (using 12.5mm gradded aggregate) for fixing hold fast& as shown on drg No CEPZ/ID-245/01 and 246/02 sheet ½ & 2/2.
17S&F 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed.
18S&F 35mm thick 2nd class hard wood in glazed and Skelton factory made shutters open rebated and prepared to receive glass/wire gauge etc with sash bars edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass/wire mesh etc sizes of members as per clause 8.20(a) of SSR Part-I complete all as specified and directed.
19S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to matchwithprelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.Note :- Door frame shall be water proof, terite proof, elegant and should have excellent screw holdig strength to fix hinges abnd hold doors properly fora long life)
20S&FFactory Made Solid PVC Moulded Door Shutter with wood free EPS , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 5 mm thick Moulded Prelam PVC Sheet on the front face & 5 mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawingsuppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engr-in-Charge.
21S&F Factorymade single extruded WPC (wood polymer composite) solid plain flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (suspension grade) ,calcium carbonate and natural fiber (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawl strength of 1800 N (face) & 900 N (edge),minimum compressive strength 50N/MM2, modulus ofelasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required sizewithnecessary full threaded star headed countersunk s.s screws ,all as specifiedand directed by engr in charge.
22S&F 35mm thick single piece factory made wire gauge door shutter of (steel & aluminium XPM) manufacturing by PVC sheets printed 5mm thick on both side on frame made out of MS tube 19 SWG size 19 x 19mm complete in all respect with lock rail & beautified by PVC beading all around fixed with PVC solvent cement complete as per Drg No.CEPZ/TD-378/Sheet 1/1 dated 27/12/2011
23S&F Anodised aluminium powder coatedframeof any colour (Thickness or powder coating not less than 50 micron for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
24S&F Anodised aluminium powder coated door shutters of any colour (Thickness or powder coating not less than 50 micron aluminium section weighing not less than0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specifiedcomplete all as specified and directed.
25S&F Anodised aluminium powder coatedwindow of any colour (Thickness or powder coating not less than 50 micron and ventilator shutters, openable/side hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.including peg stays 150mm long (2 no minm .) minm 3 nos aluminium tower bolt 75 mm long ,aluminium handle 2nos 125 mm,hinges 100mm long (minm 2 nos.) complete all as specified and directed.
26Supply and fixing 4mm thick aluminium composite panel (coloured sheet) and in additional other accessories for fitting in aluminium partition / doors / windows / ventilators /sliding shutters etc complete all as specified and directed.
27Supplied and fixed powder coating not less than 50 micron anodised designer grill of 07mm diafixed with and including aluminium flat section of size 50 x 1.5 mm fixed to aluminium windows Complete all as specified and as directed.
28M&Lin repairs double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as directed.
29S & F in repairdoor closer hydraulically regulated, designation No. 3, universal type, Aluminium body suitable for door shutter of 851 to 1000mm in width & of weight between 61 to 81 kg & fixed Aluminium(Diecast) body
30S&F 5mm thick tinted glass in door/window shuters with aluminium beading/glazing clip of both side complete all as specified and directed.
31S&F in repair 5mm thick tinted glass in door/windowshuters with aluminium beading/glazing clip of both side complete all as specified and directed.
32S&F in repair 300mm ordinary rat rail, rod pattern mild steel springs ISI marked including roller and roller plate complete including all necessary welding if required complete all as specified and directed.
33S&F300mm ordinary rat rail, rod pattern mild steel springs ISI marked including roller and roller plate complete including all necessary welding if required complete all as specified and directed.
34S&F 150mm long aluminium, anodized barrel tower bolts of extruded section ISI marked complete all as specified and directed.
35S&F 150mm extruded aluminium alloy handle fabricated anodized ISI marked complete all as specified and directed.
36S&F 100mm long butt hinges medium weight cold rolled ISI marked mild steel complete all as specified and directed including necessary welding if required .
37S&F Aluminium alloy, anodised, sliding door bolt 300mm longwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
38S&F floor door stopper of overall length of cover plate 140mmalluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor, complete all as specified and directed.
39S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete all as specified and directed.
40S& Fin repairprelaminated 18 mm thick lead free factory made 100 % solid WPC (wood polymer composite) sheet having high natural fiber content 25 to 30 % wood colour sheets with densitynot less than 500 Kg/Cum and the weight of sheet of 1 sqm should be 11 Kg(+- 5%) manufactured by ISO 9001-2015 certified company.the sheet should be 100 % water proof,termite proof ,fire retardent, manufactured by singlelayer extrusion process with excellent screw holding capacityand shore D hardness.complete including all fittings like handle,piano hinges,nomal hinges,hydraulic stoper, beading etc as per direction of Engr-in-Charge.
41S&F glavinized mild steel wire cloths 0.56mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or glavinized wire staples complete all as specified and directed.
42S&F in repair glavinized mild steel wire cloths 0.56mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or glavinized wire staples complete all as specified and directed.
43Hacking outold broken glass (any thickness, size, quality or description) from wooden frames,glazed with putty or fixed with beads complete all as specified and directed.
44S&F sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square n.exc 0.50Sqm in each panes including glass pin complete all as specified and directed.
45S&F Acrylictransparent sheet 3.00mm thick ordinary quality and glazing with oil putty in square n.exc 0.50Sqm in each panes including glass pin complete all as specified and directed.
46S&F 160mm bore, PVC rainwater (SWR) drainage pipes 4kgf single socketed, in any length with rubber ring joints as in repair, fixed to walls/floors complete all as specified and directed.
47S&F 160 mm bore pipes,PVC (SWR) bends any radius fitting for PVC (SWR) pipes as in repair, complete all as specified and directed.
48Taking down old broken cast iron pipes from existing sewage line or along plumbing stack along the walls including necessary excavation in trenches where required, removal of surplus soil and returning filling in complete, supplying, laying in trenches or along the walls with MS clamps of standard specifications and jointing 75mm bore PVC 4Kgfwaste and vent pipe ISI marked in any lengthincluding sufficient nos of bendwith or without ears with cement joints laid in floor/walls as in repair, complete all as specified and directed.
49Taking down old broken cast iron pipes from existing sewage line or along plumbing stack along the walls including necessary excavation in trenches where required, removal of surplus soil and returning filling in complete, supplying, laying in trenches or along the walls with MS clamps of standard specifications and jointing 110mm bore PVC 4Kgfwaste and vent pipe including sufficient nos of bendISI marked in any length with or without ears with cement joints laid in floor/walls as in repair, complete all as specified and directed.
50S&F 75 mm bore pipes,PVC (SWR) bends any radius fitting for PVC (SWR) pipes as in repair, complete all as specified and directed.
51S&F PVC (SWR) 75 mm floor trap, plain with grating including jointing with solvent cement as in repair, complete all as specified and directed.
52Dismantling ofwall tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,including M&L for providing glazed ceramic colouredwall tiles of exterior quality of size 450mmx350mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
53Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,including M&L Non skid ceramic colour tiles 7 to 8 mm thick ( sq/ rect) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, infloor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
54Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises, includingM&LCeramic colouerd tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,in floors etc.set and jointed in neat cement slurry with and pointed in coloured cement match the colour of tiles over 15mm thick screed bed in cement mortar 1:4 all as spd.
55Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises, including M&Lvitrified ceramic tiles light shade 10 mm thick ( sq/ rect) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, infloor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
56Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,M&L vitrified ceramic tiles 10 mm thick ( sq/ rect) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in verticle surfaces like skirting/dado, steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
57Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc set in any type of mortar complete all as specified and directed.
58Machine cutkota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over 20 mm thick screed bed in CM 1:4 , complete all as specified. Note :- Rate included for all cutting ,waste including machine cutting to make it square or rectangular,cutting and polishing by machine & size of kota stone shall not be less than 550 mmx550mm .
59Machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement rendering 10 mm thick in cement mortar 1:4and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab including rubbing and polishing & complete aggregate all as specified & directed.
60M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillers, window-cills, cooking platforms and like fixed in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. Note:- The rate included for making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded.
61S&F in repairs 25mm dia stainless steel curtain rodfixed withstainless steel brackets & ornaments end capfixed with screws,gutties etcdesign/shapeapproved by Engr-in-charge complete all as specified and directed..
62S&F bevelledfancy plain mirror 450 mm X 600 mm x 5.5 mm thick glassof selected quality with required bracket , chromium plated brass screws comlpete design/shape willbeapproved by Engr-in-charge complete all as spcified and directed.
63S&F stainless steelpeg set consisting of 5 hook fixed with screws approved by Engr-in-charge complete all as spcified and directed.
64Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition,M&L for RCC type B-1, using 20mm graded crushed aggreage as in slab supported on walls, beams and columns in floors, roofs, landing, ballonies and in shelves and the like complete all as specified and directed.
65Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition,M&L for Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs and similar articles including necessary moulds/formwork set in cement mortar (1:6) complete all as specified and directed.
66M&L for form work to sides and soffits ofshelvesfor rough finished surfaces of concrete complete all as specified and directed.
67Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water,M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement mixed with and including water proofing coumpound including formwork upto 7M height withtwo coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat complete all as specified and directed.complete all as specified and directed.(Note:- The rate included for WPC )
68Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water,M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement includingPreparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
69Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water,including M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement includingPreparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer over 1-2 mm thick wall care putty complete all as specified and directed.
70Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water,M&L rendering 10mm thick on concrete in CM 1:3in facia or edging of chajjas,ceiling and roof projectionmaking the line in true shapefinished even & smooth without using extra cementincluding formwork upto 7M heightand applying three coats of white wash complete all as specified and directed.
71Taking down cement plaster on concrete surface of chajja or facia , any description at any height ,M&L rendering 10mm thick on concrete in CM 1:4in facia or edging of chajjas, (width/height not exceeding 45 cm ) to protect movement of water inside and act in place of damaged drip course including prepration of new surface and applying two coats of cement base paint all as specifiedand directed.
72M&L for preparation of old plastered or un-plastered surface of wall up to four storeys height ofbuildings including cornices etc by brooming or steel wire brushing,scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of cement base paint including curingof any shade complete all as specified and directed.
73Preparation of old plastered or unplastered surfaces of ceiling including cornices pilasters by brooming down with steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent salt and trading oil & greasy spots etc and applying one coat of oil bound distemper on ceiling complete all as specified & directed.
74Preparing wood or wood based new or untreated surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
75Preparing old wooden surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
76Preparation of old painted steel surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and directed by Engineer-in-Charge.
77Preparing the new steel surfaces of any description over 10cm width or girthpriming with red oxide zinc crome and applying two coats of synthetic enamel paint complete all as specified and directed.
78M&L welding in repair n exc 2 cm in length thickness of metal to be welded n exc 6mm,complete all as specified and directed.
79M & L welding in repairexc 2 cmbut n exc 5 cm in length thickness of metal to be welded n exc 6mm,complete all as specified and directed.
80Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
81Dismantling timber scantlings 40sq. cm and over in section, in any position as in wooden trusses in framed work of any description.
82M&L steel work in tublar trussed incl special shaped washers etc complete using ERW or induction butt welded tubes conferming toIS 1161-1979 gde St -240 inclpurlines complete all as specified and directed.
83M & L steel work in plates (plain or chequered) channels,square cut or notched (ordinary and counter sunk) Forming holes with riveted,bolted,or welded attachments complete all as spd and directed by eng.in.charge.
84M&L PCC 1:4:8 type D-2 using 40mm graded agg. as in foundation filling and mass concrete complete all as specified.
85Excavation in post holes not exceeding 0.50cum getting out in Hard/dense soil, returning,filling in layers not exceeding 50 mtr and making good surfaces all as soecified.
86Mild steel bolts,purpose made with hexagonal or square head one end and screwed the other end or screwed both ends ; Each screwed end to be fitted with washers and one hexagonal or square nut,exceeding 30 cms, diametre of neck not exceeding 12mm.
87Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings,M&L Prepainted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws complete all as specified and directed.
88Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings,M&L pre painted galvalume aluminum zinc coated GI based plain steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws complete all as specified and directed.
89Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings,M&L 0.63 mm thick corrugated galvanized steel sheeting with two corrugation side lap,fixed with self taping screws completeas in roof,walls etc all as specified.complete all as specified and directed.
90Demolition of RCC of any description and in any position and M & L for reinforced cement concrete (nominal mix) type B1, 1:2:4 using 20 mm aggregatein Columns, pillars, piers, posts and struts , beamscomplete all as specified.
91M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions - Rough finished surfaces of concrete - Square, rectangular or polygonal
92M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
93M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
94Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, Providing and fixing tiled flase ceiling of size 595x595 mm incl of ceiling tiles in true horizontal level suspended on inter locking matrix 32 mm matel grid of hot dipped galvanised steel sections (galvanised @120gms per sqm both side incl) consisting of 3600mm long main "T" of size 24x25mm and 0.30mm thick and PPGI sheet wall angle of size 24x24mm and 0.40mm thick. Bottom exposed capping of width 24mm of all T sections shell be 0.25mm thick. PPGI wall angle is fixed aling the perimeter of ceilings to walls, partition or columns etc with rawl plug and wooden secrews at 300mm denters. Main T runners are than suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12mm dia and 38mm long dash fatners, 6 mm threaded rod with bolt for hangers spaced at max 1200 mm center tocenter along main T and not more than 150mmwith slipped joints, the last hanger at the end of each main runner should not be greater than 600mm from adjecent wall. than 1200mm long cross T is interlocked between the main T at 600 mm center tocenter to form at grid 1200x600mm and than secondary cross of length 600mm is interlocked at middle of 1200x600mm grid to form grids of 600mmx600mm . cross T at the ends having length more than 600mm are tobe supported independently. Finally PVC laminated with aluminium foil back board tiles of size 600x600x8mm thick tiles having light refectors of >=75% are placed in the grid incl dismentling of wall and ceiling board (fiber, pulp, insulation, etc) or insulation boards/ slabs/ blanket, any thickness complete all as specified and directed.
95Ditto as persrl no 94 here in before but except false ceiling tiles of any size, shape and specifications all as directed by engr in charge.
96Ditto as persrl no 94 here in before but except grid of false ceilingof any size,shape,specifications all as directed by engr in charge.
97Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceable pipe,including S&F GI tube 20mm bore medium grade galvanized with all fitting and fixed to short length on floor/wall complete all as specified and directed.
98Taking up or down GI pipe 15mm bore and connections, including cleaning for refixing or removal unserviceable pipe,S&F 15mm bore GI tubing medium grade galvanized ISI marked with all fittings complete onfloor/wall complete all as specified and directed.
99S&FRotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mmBall valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
100All as per srl item No 99above but capacity of water tank 1000 ltr complete all as specified and directed
101S&F in repair 20mm ball valvs of PTMThigh pressure with epoxy coated aluminium rod & high density plastic ballscrewed for iron pipe and fixed complete all as specified
102S&F in repairs vitreous china wash down water closet (pedestal pattern)white coloure including fixing bolts and connecting to drain pipe, including seat cover plastic flat bottom and MS Chromium plated hinging device and connection to flush pipe, anti syphonic pipe etc complete all as specified and directed.
103S&F in repairs vitreous china squatting pan, Orissa pattern size 580mm x 440mm ivory with integral foot rest includingconnection to drain out pipe and to flush pipe, anti-syphonage pipe etc complete including making good the disturbed flooring of existing specifications complete all as specified and directed.
104S&F in repair plastic water closet seat cover, back closed pattern with flat bottom,and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
105S&Fin repairs Viterous China wash basin, white, flat back, size 550x400mmexcluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specfied and as directed.
106S&F in repair Vitreous china urinal half stall complete incl providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass secrews, pointing around urinal in back in cement;with brackts, flush pipe, waste pipe ,cp spreader, grating and union for discharge pipe.
107S&F in rpairs 10 litres PVC low level flushing cistern( white colour) syphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm diaflush pipe with coupling and fixed complete all as specified and directed.
108S&F waste pipe for wash basin/urinal/sink of required sizepproved by Engr-in-charge complete all as spcified and directed.
109S&Fin repair PVC connection 15mm bore size with two nuts and washers of length 450mm complete all as specified and directed.
110S&F grating round 140mm size of PTMT (minium weight 50gms) as in repair, complete all as specified and directed.
111S&F in repair 15 bib taps, long body fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipecomplete all as specified & directed.
112S&F in repairs 15mm boreAngle valve fancy type brass chromium plated ISI marked with crutch or butter fly handle high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
113S&F in repair stop valves (ISI marked),15mm dia, cast copper alloy,chromium plated fancy type with long shank and cup(concealed type) screwd down,high pressure with crutch or butter fly handle,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed.
114S&F in repair pillar tap brass chromium plated fancy type with capstan heads screwed down high pressure with or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed.
115S&F in repairs brass chromium plated shower rose 75mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
116S&F in repair brass Chromium plated Soap Dish fixed with and incl CP screws all as specified and directed.
117S&F in repair Toilet paper holder with flat recessed type stainless steel Completeincl CP screws all as specified and directed.
118S&F in repair Hand Shower (Health Faucet) with 8 mm dia,1.2 m longLongFlexible Tube Chrome Finish & Wall Hook for Water closet complete all as specified and directed.
119S&F in repairs Brass CP wash hand basin mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15mm bore complete all as specified and as directed
120S&F in repairs Brass CP foot operated Bib tap hot & cold water or as persite requirement including all acessories for proper functioning fixed for 15mm bore complete all as specified and as directed and approved by eng in charge.
121S &F in repair Brass CP wall mixer w/o pop up waste system for hot & cold water for 15mm borecomplete fixed to connectionsasall as spd & directed .
122S &F in repair 75 mm/100 mm longBrass spindle for concealedfittingcomplete fixed to connectionsasall as spd & directed .
123S &F in repair Brassdisc spindle (full/half turn) for bib tap/pillar tap/stop cock etcfittingcomplete fixed to connectionsasall as spd & directed .
124S&F in repair bib taps, standard of PTMT any colour high pressure screwed for iron pipe of 15mm bore complete all as specified and directed.
125S&F in repair stop valve, standard of PTMT any colour high pressure screwed for for iron pipe of 15mm bore complete all as specified and directed.
126S&F in repair angle stop valve, standard of PTMT any colour high pressure screwed for for iron pipe of 15mm bore complete all as specified and directed.
127S&F in repair pillar tapof PTMT any colourscrewed for iron pipe 15mm dia complete all as specified and directed.
128S&F in repair flushingcistern long bendpipe complete all as specified and directed.
129S&F in repair flushingcistern short bendpipe complete all as specified and directed.
130S&F in repair Stainless steel Plate rack 1mm thick of size900mm x 600 mm x 200mm deep with plate racks, spoon holders, shelves etc complete all as specified and directed.
131S&F in repair sinks with drainage boardmade of stainless steel 1mm thick kitchen or labortory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
132S&F in repairsinks made of stainless steel lmmthickkitchenorlaboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
133S&F in repair sinks couplingof required size 50/65/75/100 mm aproved by Engr-in-charge complete all as spcified and directed.
134Dismantling brick tiles or terracing tiles, single layer on roofs all as specified and directed.
135M & L 40mm thick brick tiles laid on 15mm thick cement mortar 1:6and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement.
136Roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc with and including taking out existing roof treatments, brushing neat cement slurry with3.0 Kg of cement per sqm and providing 10mm thick rendering in Cement mortar 1:4on fair faces of concrete, finished even and fair mixed with and including water proofing compound to receive treatment on roof Providing and laying of water proofing treatment of roof APP (Atactic Polyproplyllen) modified prefabricated five layer 3mm thick water proofing membrane,with non woven polyester mat reinforcement of 160 gsm, weight of membrane@ 3.6 Kg/Sqm over a solvent based bitumen primer,@ 0.3 Ltr Sqm by the same manufacturer conforming to IS:3384-1986 , The membrane shall be laid using bitmun torch.The end lap should be 100 mm and the side lap must be minimum 75 mmthe membrane shall befirst laid up to the parapet wall junction and then shallbe overlapped with another membrane (flashing) with an overlap covering up to a distance of 300mm. In case parapet height is less than/ up to 500 mm, membrane shall be terminated at the top of parapet.All rain water pipe opening shall be suitably sealed with the APP membrane including two coat of silver paint all as specified and directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster) (Note:- The rate included for WPC )
137Demolition of cement Concrete(unreinforced)in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
138M&L for Cement concrete in foundations, filling and mass concrete typeB-2, 1:4:8 using 40mm graded stone aggregate as in sub base of tiles/blocks complete.
139Cement concrete type B1 1:2:4 (using 20mm graded crushed stone agg) 75 mm thick as in floor,etc finished surface even and smooth without using extra cement complete all as specified and directed.
140S & F glass deviding strip 3mm thick and 38 mm wide fixed to design complete all as specified and directed by Engr-in-Charge.
141M&L 50mm thick PCC, type B-1, 1:2:4, ( using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement complete all as specified and directed.
142S & F in repair 12 mm thick toughned glass door shutter with patch fitting and including suitable nos of hydraulic door closer/floor spring,handle,Lock etc including necessary stainless steelfittingcomplete asper manufacturerspecificationand directed by Engr-in-charge/ GE.
143S&Fin repair12 mm thick toughned glasswith including sufficient nos ofpatch stainless steel fittingetcincluding necessary all fitting,beadings to hold straight in position complete all asper manufacturerinstructions and specificationand directed by Engr-in-charge/ GE.
144S&F snake guard aluminium/GI stripcompleteall asspecificationand directed.
145Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed
146S&F in repair PVC tank lid/cover for water storage tank of 500/1000 ltrs capacity with fixing arrangement complete all as specified and directed.
147M&L for replacing of GI fittings medium grade ISI marklike long screw Elbow, socket, nipple, socket, tee etc for 15mm bore pipe complete all as directed. Note: Cost of taking down GI tubing for replacement of worn out/defective GI fitting & refixing there after shall be deemed to be included in the rates quoted by the contractor
148M&L for replacing of GI fittings medium grade ISI marklike long screw elbow, socket, nipple, socket, tee,Tank nipple etc for 20mm bore pipe complete all as directed. Note: Cost of taking down GI tubing for replacement of worn out/defective GI fitting & refixing there after shall be deemed to be included in the rates quoted by the contractor.
149S&F in repairfor Extruded aluminium alloy handles, fabricated type,anodised 150mm size complete all as specified and directed.
150S&F in repair aluminum, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 200mm complete all as specified and directed
151S&F in repairfor Aluminum alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
152S&F in repair for 100 mm long butt hinges medium weight cold rolled mild steel and fixed or welding to steel chowkhats complete all as specified and directed.
153M&L for complete removal of existing treatment internally surface of wall and applying min 1.5 mmthick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
154S&F in repair Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;l adders; framed balusters; walk ways; railings; framework of water tanks, cattle trap and similar work conforming to Fe.290.Gde-E-165,ornamental and intricate design complete all as spd and directed.
155Demolition of cement concrete or lime concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing the debris outside from defence landcomplete all as specified and directed.
156M&L PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer’s instructions as in padding on roof, surface finished even and smooth without using extra cement all as specified and as directed.(Note:- The rate included for WPC)
157M&L for Providing cement concrete 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer’s instructions as in roof kerbs,bands etc or mud stops, rounded or chamfered on edges cement all as specified and as directed.(Note:-TheRate included for WPC )
158M&L for Plain Cement concrete 1:3:6 Type C-1 ,M-10 (Nominal mix) using 20mm graded crushed stone aggregate as in filling of sunken floorto receive floor top finished complete all as specified and directed.
159M&L for (a) 15mm thick plaster in cement sand mortar (1:4) mixed with water proofing compound (conform to IS 2645-Specifictions for integral cement water proofing compound) as approved as per manufacturer’s instructions shall be applied both on floor and wall. The surfaces then shall be cured and allowed to dry. All the joints of pipe shall be sealed properly as per the instruction of agency who is carrying out water proofing treatment. (b) Apply a coat of Moisture Cured High Tensile Elastomeric Modified Poly Urethane Based Liquid Membrane on floor as well as on wall as per manufacturer’s instructions of make/manufacturers as specified. After the treatment is over, sunken portion shall be kept full of water for atleast one week to check that no seepage is seen from the external surface. (c) Manufacturer/approved agencies for water proofing treatment to sunken slab/portion membrane shall be as per approved list (Note:-TheRate included for WPC )
160M & L 50 mm bore ‘medium grade’ galvanizedpipe as in spout including neccesary cutting to wall/beam etc and proper setting in cement moratr 1:3 , complete all as specified.
161Refixing of door shutters in same openingof any description exc 1 sqm but not exc 2 sqm eachcomplete all as specified and directed.
162Repair the leakage/ seepage/ hole/ crack of roof sheet of any description and in any position and upto 7.5 m height using Super flash Strip 100/150mm wide .
163Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.