Establishment Of Advanced Virus And Other Pathogens Diagnostic …. Farmers And Entrepreneurs In West Bengal -Purchase , Particulars , Online Ups With Stabilizer: Uninterrupted Power Supply Through True Online Ups. O One 6Kva Power Bank Within Built I, mohanpur-West Bengal

Bidhan Chandra Krishi Viswavidyalaya has published Establishment Of Advanced Virus And Other Pathogens Diagnostic …. Farmers And Entrepreneurs In West Bengal -Purchase , Particulars , Online Ups With Stabilizer: Uninterrupted Power Supply Through True Online Ups. O One 6Kva Power Bank Within Built I. Submission Date for this Tender is 23-09-2022. Tape Supply Tenders in mohanpur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

33949520
Establishment Of Advanced Virus And Other Pathogens Diagnostic …. Farmers And Entrepreneurs In West Bengal -Purchase , Particulars , Online Ups With Stabilizer: Uninterrupted Power Supply Through True Online Ups. O One 6Kva Power Bank Within Built I
Open Tender
Indian
West Bengal
mohanpur
23-09-2022

Tender Details

Establishment Of Advanced Virus And Other Pathogens Diagnostic …. Farmers And Entrepreneurs In West Bengal -Purchase , Particulars , Online Ups With Stabilizer: Uninterrupted Power Supply Through True Online Ups. O One 6Kva Power Bank Within Built Isolation Transformer. O Double Conversion. O One Kva On-Line System O Power Backup Should Be 3Hrs+ For Both Units O Battery Bank Should Be Straight Warranty For 3 Years O Full Operation Of The System Should Be Warranted Also For Three Years. O Supply, Installation With Necessary Accessories Complete , Electrophoresis System : Mini Gel Electrophoresis • System Should Be Completely Self Contained System Designed For Quick Checks Of Samples. • Gel Casting, Running And Analysis All Should Be Performed In The Same Unit. • Should Have Uv Transparent Base To Allow Direct Viewing On A Uv Transilluminator. • Gel Dimensions Should Be 10X8cm. • Should Have In-Built Tray With Dual Comb Slots. • Two Combs Of 1.5Mm Thickness For 8 Samples Should Be Provided With The Unit. • Casting Dams Should Also Be Included For Tape Free Casting. • Buffer Volume Should Not Be More Than 50Ml. • Should Be Able To Run Maximum Of 40 Samples. • Option For Multichannel Compatible Combs. • The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) . Midi Gel Electrophoresis:The Horizontal Electrophoresis Unit Must Include 10X10cm Tray And 7X7 Cm Tray • Gel Trays Should Be Uv Transparent. • Lid And Cables Should Be Separate And Must Not Be Attached. • Bromophenol Blue Migration Should Be Approx 4-5Cm / H At 90V. • Run Time Should Be 45-60 Min At 90. • Should Include 1 Mm Thick 2 Combs Of 16 Sample Wells. • Buffer Volume Should Not Be More Than 300Ml. • Tank Of The System Should Be Single Moulded To Ensure Leak Proof Buffer Tank. Even The Parts Should Also Be Single Molded That Are Easy To Repair And Replace. • 16 Sample Combs Should Have 16 ?L Sample Capacity In Each Well. • The Electrodes Should Not Be Attached To The Tank And Should Be Cassette Type Electrodes For Easy Repair And Replacement. • Should Have Pure Platinum Wire And Gold Plated Corrosion Resistant Electrodes. • Should Include Casting Dams For Tape Free Casting Of Gels. • Should Include Loading Guides For Easy Identification Of Wells. • Should Have Color Coded Combs Option And Should Have Options For 0.75Mm, 1Mm, 1.5Mm And 2Mm Combs. • It Should Support Widest Range Of Combs To Run Up To 100 Samples. • The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) . Power Pack• The Power Pack Should Be From A Reputed Manufacturer. • It Must Have 5-300V, 1-700Ma And 150W With 1V / 1Ma Increment. • Should Be Capable Of Running At Constant Current Constant Voltage. • Power Supply Should Have 5 Pair Of Output To Connect 5 Units All Together In The Same Unit. • It Should Be Programmable To Set Different Programs. • Display Should Be 2.4” Lcd Display. •It Must Include Preset Programs And Must Have 6 Steps With 30 Programmable Files. • Should Have Timer To 999 Minutes And Timer Alarm Too After The End Of Run. • When Target Constant Mode Is Set, The System Automatically Adjusts The Two Other Parameters To Maximum To Allow For A Constant Run. • Safety Feature: No Load Detection, Leakage Detect, Over Load Detection, Over Temperature Protection, & Sudden Load Change Detection. • Operating Temperature 4?~ 40?. • The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) .

Key Value

Document Fees
Refer document
EMD
INR 6000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Establishment of Advanced virus and other pathogens diagnostic …. Farmers and Entrepreneurs in West Bengal
Sl. No. Item Description
1Particulars
2Online UPS with stabilizer: Uninterrupted power supply through true online UPS. o One 6KVA Power bank within built isolation transformer. o Double conversion. o One KVA on-line system o Power backup should be 3hrs+ for both units o Battery bank should be straight warranty for 3 years o Full operation of the system should be warranted also for three years. o Supply, installation with necessary accessories complete
3Electrophoresis system : Mini gel electrophoresis • System should be completely self contained system designed for quick checks of samples. • Gel casting, running and analysis all should be performed in the same unit. • Should have UV transparent base to allow direct viewing on a UV transilluminator. • Gel dimensions should be 10x8cm. • Should have in-built tray with dual comb slots. • Two combs of 1.5mm thickness for 8 samples should be provided with the unit. • Casting dams should also be included for tape free casting. • Buffer volume should not be more than 50ml. • Should be able to run maximum of 40 samples. • Option for multichannel compatible combs. • The unit must have Safety Requirements for Electrical Equipment for measurement, Control, and Laboratory Use – Part 1: EN61010-1: 2001, General requirements Following the provisions of Directives 73/23/EEC (Low Voltage) and 89/336/EEC (EMC) as amended by 93/68/EEC (CE Marking). Midi gel electrophoresis:The horizontal electrophoresis unit must include 10X10cm tray and 7X7 cm tray • Gel Trays should be UV transparent. • Lid and cables should be separate and must not be attached. • Bromophenol Blue migration should be approx 4-5cm/h at 90V. • Run time should be 45-60 min at 90. • Should include 1 mm thick 2 combs of 16 sample wells. • Buffer volume should not be more than 300ml. • Tank of the system should be single moulded to ensure leak proof buffer tank. Even the parts should also be single molded that are easy to repair and replace. • 16 sample combs should have 16 µl sample capacity in each well. • The electrodes should not be attached to the tank and should be cassette type electrodes for easy repair and replacement. • Should have pure platinum wire and gold plated corrosion resistant electrodes. • Should include casting dams for tape free casting of gels. • Should include loading guides for easy identification of wells. • Should have color coded combs option and should have options for 0.75mm, 1mm, 1.5mm and 2mm combs. • It should support widest range of combs to run up to 100 samples. • The unit must have Safety Requirements for Electrical Equipment for measurement, Control, and Laboratory Use – Part 1: EN61010-1: 2001, General requirements Following the provisions of Directives 73/23/EEC (Low Voltage) and 89/336/EEC (EMC) as amended by 93/68/EEC (CE Marking). POWER PACK• The power pack should be from a reputed manufacturer. • It must have 5-300V, 1-700mA and 150W with 1V/1mA increment. • Should be capable of running at constant current constant voltage. • Power supply should have 5 pair of output to connect 5 units all together in the same unit. • It should be programmable to set different programs. • Display should be 2.4” LCD display. •It must include preset programs and must have 6 steps with 30 programmable files. • Should have timer to 999 minutes and timer alarm too after the end of run. • When target constant mode is set, the system automatically adjusts the two other parameters to maximum to allow for a constant run. • Safety Feature: No Load detection, Leakage detect, Over load detection, Over temperature protection, & Sudden load change detection. • Operating temperature 4?~ 40?. • The unit must have Safety Requirements for Electrical Equipment for measurement, Control, and Laboratory Use – Part 1: EN61010-1: 2001, General requirements Following the provisions of Directives 73/23/EEC (Low Voltage) and 89/336/EEC (EMC) as amended by 93/68/EEC (CE Marking).