Delhi University has published Supply, Installation, Testing & Commissioning Of Multimode Microplate Reader System Scientific Equipment For Hansraj College, University Of Delhi - Multimode Microplate Reader System 2 Multimode Microplate Reader System Should Have Following Dete. Submission Date for this Tender is 22-09-2022. Chemical Supply Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Multimode Microplate Reader System |
2 | Multimode Microplate Reader system should have following Detection Chemistries UV-VIS Absorbance, Fluorescence Intensity and Luminescence. General Feature 1250000 • System should have Plate formats: 6, 12, 24, 48, 96, 384-well plates ANSI/SLAS • System should have light source: Two high-energy xenon flash lamps • System should have reading capabilities: Microplates, and cuvettes. • System should have Detectors: PMT for Fluorescence & Luminescence & Silicon Diode for Absorbance. Preferably Ultra cooled PMT for Fluorescence and Luminescence. • System should have shaking option: Linear, orbital, and double orbital • System should have temperature control: 4°C above ambient to 45°C and temperature uniformity ±1°C at 37°C. • System should have Spectral scanning for Absorbance. System should have endpoint reading, kinetic reading for Absorbance, Fluorescence and Luminescence. • System should have well scanning Over 20 by 20 or better. • System should have NFC-tagged filters for fluorescence, luminescence • System should have AutoPMT feature to allows a wide range of concentrations to be prepared and read on one plate, avoiding saturation (or the loss of signal). |
3 | Absorbance• Wavelength range: 200–1000 nm. • Wavelength selection: 1.0 nm increments • Wavelength bandwidth:= 5 nm or better • Wavelength accuracy: ± 2 nm across wavelength range • Wavelength precision (repeatability): ± 0.2 nm • Photometric range: 0–4.0 ODFluorescence intensity• Wavelength range: capability 250–850 nm • Wavelength selection: Filter • Dynamic range: > 6 decades • Sensitivity (fluorescein): 1 pM Luminescence • Wavelength range: 300–650 nm • Wavelength selection: Filter • Dynamic range:> 7 decades • Sensitivity (ATP) : 2 pM Fluorescence Filters System should be quoted with Coumarin derivative (AMC), Fluorescein/FITC, Alamar blue, Tryptophan, Nano orange, Quant IT protein assay, Alexa Fluor 594, and Texas Red filters as a standard. Optional ItemSystem should be quoted with Alexa Fluor 647/cy5 and Alexa Fluor 750/cy7 filters as an optional. CertificationSystem should be CE and ISO certified. Warranty System should be quoted with three years extended warranty. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail