Indian Oil Corporation Limited-IOCL has published Development Of New A Site Ro Between K Lalnghakliana Filling Station And Silaimual Zampuimanga, Dist Aizawl, Mizoram. => Limited. Submission Date for this Tender is 20-09-2022. Land Development Tenders in aizawl Mizoram. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | TANK INSTALLATION UNDERDRIVEWAY-2NO.S |
2 | Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor) |
3 | iii) 15/20 KL Tank with fittings : 0 - 30 Km |
4 | iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km |
5 | Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20 |
6 | iv) In brick masonry pit with RCC matt under driveway including RCC top slab as per standard Drg. ENG/318. Manhole cover plates and frame to be paid separately . |
7 | Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications |
8 | iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting |
9 | Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping |
10 | ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping |
11 | iv) S/L Welded U/G HD MS Pipes of 40mm dia with fittings,doping |
12 | Supplying and installation of the following threaded |
13 | i) 80 mm dia Aluminium camlock coupling - Male only |
14 | Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazingwire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. |
15 | iii) Supply & installation of U type CS bend on vent pipe of 40 mm dia |
16 | Providing stainless steel wire mesh 32 SWG, 11 mesh per linear cm of of non corrosive metal in two layers on existing vent hoods ‘U’ type (on both ends) including brazing, etc. complete |
17 | iii) 32SWG SS wire mesh both sides of existing U vent hood 40mm dia |
18 | Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loadedtype or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Coverand adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. |
19 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil & disposal of surplus excavated soil as directed, within or outside the site at an unobjectionable place. |
20 | i) All kinds of Soil |
21 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
22 | ii) Retaining/return wall, wall (any Thickness) including attached pilaster buttresses, plinth & string courses, fillets, kerbs&steps etc |
23 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
24 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH |
25 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
26 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
27 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
28 | Providing Neat cement punning |
29 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
30 | vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm) |
31 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
32 | ii) 32 x 6 mm G.I.strip |
33 | i) 50 x 10mm G.I. Strip |
34 | Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) |
35 | PROVISION OF EARTHING |
36 | Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long |
37 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
38 | INSTALLATION OF MPDs & STPs WITH ISLAND |
39 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH2CN00600 |
40 | i) All kinds of Soil |
41 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
42 | i) Local Fine Sand within grading zone IV |
43 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
44 | iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm) |
45 | viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) |
46 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
47 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH |
48 | Centering and shuttering including strutting, propping etc. and removal of form for : |
49 | i) Foundations,footings,bases of columns, etc. for mass concrete |
50 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
51 | iii) Granite of any colour and shade having Area of slab upto 0.50 sqm |
52 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
53 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
54 | Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor) |
55 | xii) MPD/MPP pumps upto 2 nos., 0-30 Km |
56 | xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km |
57 | viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km |
58 | ix) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km |
59 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
60 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
61 | iii) 3 Core x 1.5 sq. mm. (copper) |
62 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
63 | vii) 3 Core x 2.5 sq. mm |
64 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
65 | vii) 3 Core x 2.5 sq. mm |
66 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
67 | iv) 25 x 6 mm GI strip |
68 | MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive ofMCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) |
69 | ii) S/E 6 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1No. & 6 to 16A SP as outgoing - 6 Nos. for each phase. |
70 | CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protectionincluding all accessories complete (for displays) for the following VA ratings. |
71 | iii) 500VA CVT |
72 | SINGLE SERVO VOLTAGE STABILISER Supply and fixing of 230V, Single phase, AC Servo voltage stabilizer ofapproved makes,(Range - 180 - 250 minimum) shall be provided for Individualdispensing pump as per IE Regulation and as per specification |
73 | iv) 5KVA stabilizer |
74 | Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen |
75 | MINIATURE CIRCUIT BREAKERS (MCB) Supplying & fixing of Miniature Circuit Breakers as per approved make of 10KA Breaking cpacity of following ratings |
76 | iii) 6A to 32A DP MCB |
77 | Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge |
78 | Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump |
79 | i) 2 product - 4 nozzle MPPs/MPDs |
80 | Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve |
81 | iii) S/I Screwed type GM Ball Valve of50 mm dia |
82 | Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. |
83 | LGSF SALES BUILDING |
84 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH2CN00600 |
85 | i) All kinds of Soil |
86 | Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete |
87 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
88 | i) Local Fine Sand within grading zone IV |
89 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil |
90 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
91 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
92 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
93 | Centering and shuttering including strutting, propping etc. and removal of form for : |
94 | i) Foundations,footings,bases of columns, etc. for mass concrete |
95 | iv) Lintels, beams plinth beams,girders bressumers and cantilevers |
96 | v) Columns, Pillars, Piers, Abutments, Posts and Struts. |
97 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
98 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
99 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
100 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
101 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
102 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement |
103 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
104 | YARD LIGHT & ELECTRIFICATION |
105 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. |
106 | Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL. |
107 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
108 | xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS |
109 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
110 | xviii) 3.5 Core x 50 sq. mm |
111 | Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen |
112 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
113 | x) 8 S.W.G. Cu. Wire |
114 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
115 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
116 | vii) 3 Core x 2.5 sq. mm |
117 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH2CN00600 |
118 | i) All kinds of Soil |
119 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
120 | vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) |
121 | Centering and shuttering including strutting, propping etc. and removal of form for : |
122 | i) Foundations,footings,bases of columns, etc. for mass concrete |
123 | Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
124 | Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing. |
125 | i) For cables 2.5 to 4 sqmm XLPE / AYFY |
126 | OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : |
127 | iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) |
128 | Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. |
129 | ii) "L" Pole |
130 | iii) 3 Core x 1.5 sq. mm. (copper) |
131 | AIR FACILITY |
132 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH2CN00600 |
133 | i) All kinds of Soil |
134 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
135 | Centering and shuttering including strutting, propping etc. and removal of form for : |
136 | i) Foundations,footings,bases of columns, etc. for mass concrete |
137 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
138 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
139 | ii) 1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of 20mm) |
140 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
141 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH |
142 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
143 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
144 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
145 | i) Local Fine Sand within grading zone IV |
146 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
147 | iii) Granite of any colour and shade having Area of slab upto 0.50 sqm |
148 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
149 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
150 | Providingandfixingmachinemouldedaluminiumcovering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. |
151 | ii) Powder coated aluminium sheet 2.5mm thick(minimum thickness of powder coating 50 micron) |
152 | Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: |
153 | ii) Horizontal air compressor Assembly of 3 HP (160-220 LITRES) including civil works |
154 | Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) |
155 | SEPTIC TANK |
156 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH2CN00600 |
157 | i) All kinds of Soil |
158 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
159 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
160 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
161 | iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm) |
162 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
163 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
164 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
165 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH |
166 | vii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:3 (1 cement : 3 coarse sand) IN FOUNDATION AND PLINTH |
167 | Providing and laying cement plaster on surfaces with Coarse sand including curing etc. |
168 | i) 12mm Cement plaster of mix 1:4 (1 cement: 4 coarse sand) |
169 | Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : |
170 | iii)150 mm dia. pipe |
171 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
172 | PAVER BLOCK DRIVEWAY |
173 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH2CN00600 |
174 | i) All kinds of Soil |
175 | Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. |
176 | i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired |
177 | Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer |
178 | Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications. |
179 | Providing & laying factory made Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih strong vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL"s specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881 maximum dimensional deviations of +/- 3mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. |
180 | ii) M40 grade 80 mm thick Plain finish |
181 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
182 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
183 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
184 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
185 | Centering and shuttering including strutting, propping etc. and removal of form for : |
186 | i) Foundations,footings,bases of columns, etc. for mass concrete |
187 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
188 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
189 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises |
190 | Providing and laying non-pressure NP3 class (Medium class) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc.complete |
191 | ii) 900 mm dia. R.C.C. pipe |
192 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
193 | BUFFER STRIP |
194 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH2CN00600 |
195 | i) All kinds of Soil |
196 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
197 | vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) |
198 | Centering and shuttering including strutting, propping etc. and removal of form for : |
199 | i) Foundations,footings,bases of columns, etc. for mass concrete |
200 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
201 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH |
202 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
203 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
204 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
205 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
206 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
207 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
208 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
209 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
210 | CANOPY (14 X 8) |
211 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil & disposal of surplus excavated soil as directed, within or outside the site at an unobjectionable place. |
212 | i) All kinds of Soil |
213 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
214 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
215 | vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) |
216 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
217 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
218 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
219 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
220 | Centering and shuttering including strutting, propping etc. and removal of form for : |
221 | i) Foundations,footings,bases of columns, etc. for mass concrete |
222 | Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominalsize), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
223 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
224 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
225 | Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
226 | i) Profile Sheet for roofing |
227 | iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) |
228 | iv) Plain Sheet for Gutter (600 mm over all girth) |
229 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
230 | iii) 160 mm diameter PVC Rain water pipe |
231 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa & 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. |
232 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
233 | Providing valleys of 90cm wide overall in plain G.S. sheet 1.60mm thick with zinc coating not less than 350gm/m², fixed with polymer coated J or L hooks, bolts and nuts 8mm dia.. G.I. limpet : and bitumen washers complete OR G.S.Sheet on fascia of Canopy upto 1.0m width, fixing with rivets/screws etc in place of J/L hooks etc. |
234 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : |
235 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate |
236 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
237 | iii) 3 Core x 1.5 sq. mm. (copper) |
238 | Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing. |
239 | i) For cables 2.5 to 4 sqmm XLPE / AYFY |
240 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
241 | vi) 3 Core x 1.5 sq. mm. |
242 | vii) 3 Core x 2.5 sq. mm |
243 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
244 | iv) 25 x 6 mm GI strip |
245 | Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen |
246 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty |
247 | iv) 300 mm dia. R.C.C. pipe |
248 | MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive ofMCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) |
249 | iii) S/E 8 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1 No. & 6 to 16A SP as outgoing - 8 Nos. for each phase. |
250 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
251 | Linear LED |
252 | DISPLAY BOARD (INGRESS, EGRESS & YARD PO |
253 | STANDARD DISPLAY BOARD-EGRESS SIDE |
254 | i) All kinds of Soil |
255 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
256 | i) M-15 grade plain cement concrete (cement content considered @ 240 kg/cum |
257 | i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm |
258 | i) Foundations,footings,bases of columns, etc. for mass concrete |
259 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
260 | i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate |
261 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
262 | i) Hot finished welded type tubes |
263 | ii) Powder coated aluminium sheet 2.5mm thick(minimum thickness of powder coating 50 micron) |
264 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
265 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
266 | i) Pipes,cables etc. not exceeding 80mm dia |
267 | vii) 3 Core x 2.5 sq. mm |
268 | i) for 2.5 sq.mm. cable entry size with 9 terminals |
269 | ii) 2+8 way SPN |
270 | ii) Upto 32A DP MCB |
271 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
272 | STANDARD DISPLAY BOARD-INGRESS SIDE |
273 | i) All kinds of Soil |
274 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
275 | i) M-15 grade plain cement concrete (cement content considered @ 240 kg/cum |
276 | i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm |
277 | i) Foundations,footings,bases of columns, etc. for mass concrete |
278 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
279 | i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate |
280 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
281 | i) Hot finished welded type tubes |
282 | ii) Powder coated aluminium sheet 2.5mm thick(minimum thickness of powder coating 50 micron) |
283 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
284 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
285 | i) Pipes,cables etc. not exceeding 80mm dia |
286 | vii) 3 Core x 2.5 sq. mm |
287 | i) for 2.5 sq.mm. cable entry size with 9 terminals |
288 | ii) Upto 32A DP MCB |
289 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
290 | YARD LIGHTS ADVERTISEMENT BOARD |
291 | i) Hot finished welded type tubes |
292 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
293 | UNIPOLE FOUNDATION |
294 | i) All kinds of Soil |
295 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
296 | Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete |
297 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
298 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
299 | i) Foundations,footings,bases of columns, etc. for mass concrete |
300 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
301 | iii) Granite of any colour and shade having Area of slab upto 0.50 sqm |
302 | ii) 110 mm diameter |
303 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
304 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate |
305 | xxiv)3 Core x 2.5 sq. mm Copper Cable XLPE |
306 | vii) 3 Core x 2.5 sq. mm |
307 | Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen |
308 | Supply & fixing of weatherproof125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL makeincluding clamping arrangement, all complete as per specification & direction of Engineer In-charge. |
309 | ii) Upto 32A DP MCB |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy