}

Special Repair To Bldg No T 41 Ors Barrack At Ib Hill At Chakabama Military Station Under Age I Zakhama., Zakhama-Nagaland

Military Engineer Services-MES has published Special Repair To Bldg No T 41 Ors Barrack At Ib Hill At Chakabama Military Station Under Age I Zakhama.. Submission Date for this Tender is 28-09-2022. Building Work Tenders in Zakhama Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

33805860
Corrigendum : Special Repair To Bldg No T 41 Ors Barrack At Ib Hill At Chakabama Military Station Under Age I Zakhama.
Open Tender
Indian
Nagaland
Zakhama
28-09-2022

Tender Details

Special Repair To Bldg No T 41 Ors Barrack At Ib Hill At Chakabama Military Station Under Age I Zakhama.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 18200.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : SPECIAL REPAIR TO BLDG NO T-41 (OR"S BARRACK) AT IB HILL AT CHAKABAMA MILITARYSTATION UNDER AGE(I) ZAKHAMA.
Sl. No. Item Description
1Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., completeall as specified and as directed.
2S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with "L" type or "J" type or cranked hook bolts and washers, in roof covering, walls cladding etc, with grade of zinc coating 275 complete all as specified and as directed.
3S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
4Refixing only galvanised corrugated mildsteel sheeting as obtained from dismantling of old sheets here in before with two corrugation side lap, fixed with & including "L" type or "J" type or cranked hook boltsin roof covering, wall cladding etccomplete all as specified and as directed.
5Refixing onlyplain, galvanised, mild steel sheeting, as obtained from dismantling of old sheets here in before in ridges, hips, valley gutters, drip, wall clading and straight flashings etc complete all as specified and as directed.
6M&L for Preparing new zinc (or galvanised) surfaces to recieve painting , by coating with mordant solution including washing and cleaning etc and applyingtwo coat of synthetic enamel paint over a coat of red oxided zinc chorome primer complete all as specified and as directed
7M & L for 4mm thick coloured designer non asbestos fiber cement building boardsfixed/laid to GI frame workincluding taking out old ceiling board of any description complete all as specified and as directed.
8M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and including ceiling section ( not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete includinghangers 4 mm dia G I (upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners12.5 mm dia 40 mm long complete all as specified and as directed.
9S&F4mm thick,plywood, grade BWR,type BB, fixed with nails to timber frame workfixed with nails to timber frame work on wallincluding taking out old plywood of any description complete all as specified and as directed.
10M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
11M&Lfor preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
12Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
13M & L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed.
14S&F mild steelHand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and as directed.
15M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
16M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
17Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cmthick ( Below or above ground)complete all as specified and directed.
18M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed.
19M&L for 40mm thick PCC 1:2:4,type B1 (using 20mm graded stone aggregate) as in floor, finished the surface even and smooth with using extra cement complete all as specified and as directed.
20S&F 3mm thick 38mm width glass dividing strip and inserted in position conform to design complete all as specified and as directed.
21Demolition of brick or stone masonry work built in cement mortarincluding all quoins, arches, pillars etc complete all as specified and as directed.
22M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
23M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed.
24Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
25M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
26M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound (@ 3% by weight of cement or as per manufacture"s instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundwill be measured and paid separately as "Supply only".
27Supply only integral water proofing compound complete all as specified and as directed.
28M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat ofprimer complete all as specified and as directed.
29M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
30Dismantling timber scantling 40Sqcm and over in section as in unframed workin any position complete all as specified and as directed.
31M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed work complete all as specified and as directed.
32M & Lfor preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and applying two coats of creosote complete all as specified and directed.
33M&L for 2nd class hardwoodplain fillets bullnosedsplayed, chamfered or rounded on one edge or face area exc 3cm and n exc 6 sqcmincluding dismantling of old fillet of any description complete all as specified and as directed.
34M & L for 2nd class hardwood, weather boarding, clean sawn, plain, 25 mm thick or feather edged15 mm to 20 mm thick and fixed with 30mm laps including taking out old boarding complete all as specified and as directed.
35Taking down shutter of any descriptionarea exc 1 sqm but n exc 2 Sqm each including builders hardwarecomplete all as specified and as directed.
36Taking down shutter of any descriptionarea n.exc 1 sqmeach including builders hardware complete all as specified and as directed.
37S&F 30mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
38S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etcwith plain, chamfered or rounded, mitred beads (with sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
39S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed.
40S & F 75 mm size stainless steel butt hinges, complete all as specified and as directed.
41S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
42S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
43S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
44S&F 100 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
45S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed.
46S & F floor door stopper of aluminium alloy body and tongue, overall length of cover plate 140 mm anodised with hard drawn steel spring, fixed in floors complete all as specified and as directed.
47S & F prelaminated particle board 18/19mm, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws as in pelmet box includind taking out old pelmet box of any description complete all as specified and as directed.
48S&F in repairs, harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
49S&F in repairs,175mm to 250mm long solid aluminium bodyHat and coat hooks complete all as specified and as directed.
50S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
51S&F in repair galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed.
52M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including25 mm thick PCC sub base in (1:2:4) type B0 (using 12.5mm graded stone aggregate) and screed bed of 15 mm thick in cement mortar (1:4) complete all as specified and as directed.
53M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular )area of each tiles exc 0.11 sqm but not exceeding 0.18 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with colouredtilesover and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
54M&L for writing letters & figures ( Building Nos) (Block, Roman, Italic or Indian) not exc 30cm high complete all as specified and as directed.
55Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
56M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
57Allas peritem serial No 56 here-in-before but for One 3 pin 5 Ampsocket outlet on same board with other switches.
58Allas per item serial No 56here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board.
59All as per item serial No 56 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
60S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
61S & F switch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed.
62S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush typecomplete all as specified and as directed.
63S & F socket, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed.
64S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
65S & F lamp holder, insulated, PVC / polycarbonate /bakelite bodyincluding 10W LED lampscomplete all as specified and as directed.
66S & Fstepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
67S&FLED box type fitting pre-wired including LED tube 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on PVC blockcomplete all as directed.Make:- Jaquar Model-LGLZ01X020XC/ LGLZ01X020XN/LGLZ01X020XW or Havells Model-LUMILINEPLUSBS20WLED865SPCSS or equivalent model of make Philips /GE/Crompton
68S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- HavellsModel HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips /Crompton /GE.
69S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and as directed.
70S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
71S&F MCBs, SPN 6 to 32 Amps, 10 KA,"C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
72S&F MCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
73M&L for Sub main wiring with 2 runs of 2.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.)
74S&F 1100 volts grade heavy duty flat cable ofsize 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed.
75Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, dismantling of blades and transporting from any location inside army area to MES E/M store yard and hanging the same carefully in hook and connecting up including provision of cable from ceiling rose or connector to ceiling fan complete all as specified and as directed.
76M&L forGI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 3.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
77M&L for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-Iincluding demolition of old earthing complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail