Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-09-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-09-2022 |
| 2 | 06-09-2022 | TENDER VALUE | Other | 20-09-2022 |
| Sl. No. | Item Description |
| 1 | Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 2 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 3 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 4 | M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 5 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 7 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 8 | M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed. |
| 9 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 10 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 11 | M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 12 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 13 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 14 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed. |
| 15 | M & L for RCC M25 (Design Mix) using 12.5 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 16 | M & L for RCC M25 (Design Mix) using 12.5 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. |
| 17 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 18 | M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed |
| 19 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair complete all as specified and directed. |
| 20 | M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 40 mm thick as in floor/damp proof courseor as levelling course of roof padding complete all as specified and as directed. |
| 21 | M and L for Bitumen Blown any grade, applied hot, two coats, to concrete surface at the rate of 1.5 kg per sqm per coat and complete all as spcified and directed. |
| 22 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 23 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 24 | Providing and fixing inter locking metal grid (anodised aluminium snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge. |
| 25 | M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, fixed to timber/GI /Aluminium framework with screw complete all as specified as directed by the Engineer-in-Charge. |
| 26 | M & L for preparation of new or previously untreated plastered/gypsum/any other ceiling surfaces and applying one coat of oil bound distemper over a coat of suitable primer complete all as specified and as directed. |
| 27 | M & L for 12 mm thick (7 ply) decorative plywood with ornamental veneers on one face, boiling water resistance(BWR) Grade and Type 1 as per IS 303: 1989, IS 1328: 1996 and IS 848: 2006; fixed with screws to timber frame work complete all as specified and as directed. |
| 28 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. |
| 29 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. |
| 30 | Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and fair complete all as specified and as directed. |
| 31 | Preparation of newly plastered surfaces/boards on ceilings and applying three coats of white wash complete all as specified and as directed. |
| 32 | Supply only integral water proofing compound. |
| 33 | Preparation of newly plastered surfaces on walls and applying one coat of white wash complete all as specified and as directed. |
| 34 | M & L for preparation of new plaster surface of wall and applying two coats of cement base paint complete all as specified and as directed. |
| 35 | M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed. |
| 36 | Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed. |
| 37 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 38 | M & L for polythene film, 150 micron thick, laid on a coat of bitumen primer @ 0.50 kg per sqm complete all as specified and as directed. |
| 39 | M & L for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, length 340 mm to 460 mm, 7- 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed. |
| 40 | M & L for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, length460 mm to 650 mm, 7-8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed. |
| 41 | M & L for glazed, colour ceramic wall tiles (group B III), 300 mm X 450 mm X 7-8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed. |
| 42 | S & F Fibre Glass reinforced plastic (FRP) door frames conforming to IS: 14856:2000, of cross section 90 mm X 45 mm, having single rebate of 32mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fireresistant grade unsaturated polyester resin and chopped mat. Door frame shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all the sides. MS stay shall be provided at the bottom to steady the frame, complete all as specified and directed |
| 43 | S & F to existing door frames 30mm thick Fibre Glass reinforced plastic (FRP) panelled door shutter of required colour made with fire retardant grade unsaturated polyester resin, moulded to 3mm thk FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thk FRP laminate for panels conforming to IS:14856, including fixing to frames,complete as per manufacture instructions and all as specified and directed |
| 44 | S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed. |
| 45 | S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed. |
| 46 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 47 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 48 | S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. |
| 49 | S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed. |
| 50 | Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 51 | S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. |
| 52 | M & L for forming 12 mm thick expansion joints in 30mm thick slab filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and as directed. |
| 53 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge |
| 54 | S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed. Note- PCC filling of hollow section shall be measured and paid seperately. |
| 55 | M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in pole coping including necessary formworks for fair finish surface complete all as specified and directed by Engineer- in-charge. |
| 56 | S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 57 | S & F 1.25 mm thick mild steel, plain, black sheet in hearths; covering to door shutters; covering to door chowkhats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed. |
| 58 | S & F 200 mm size, mild steel barrel tower bolts with mild steel barrel and mild steel bolt, dia of bolt 10 mm, bolt finished bright, other parts finished stove enamelled black complete all as specified and as directed. |
| 59 | S & F mild steel sliding door bolts, type I (plate type), size 300 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed. |
| 60 | S & F 125 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 61 | S & F mild steel, pressed oval type handle, 150 mm size, stove enamelled black finish complete all as specified and as directed. |
| 62 | S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. |
| 63 | M & L for vitreous china urinal partition white of size 675 mm X 325 X 85 mm fixing to wall by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete M15(Nominal Mix) using 20 nominal size crushed stone coarse aggregate and finished smooth complete all as specified and as directed. |
| 64 | S & F wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed. |
| 65 | S & F 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 66 | Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge. |
| 67 | Providing and fixing 30 mm thick factory made solid panel PVC door shutter as per IS 15931: 2012 with 19 gauge thickness mild steel tube and tapering 20 mm in 45° angle on both sides forming styles and on the inner side to form top and bottom rail and on both sides to form lock rail complete all as specified and as directed. |
| 68 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 69 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 70 | S & F 100mm butt hinges, extruded aluminium alloy with brass wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 100C22 as per IS 205: 1992 complete all as specified and as directed. |
| 71 | S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 72 | S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 73 | S & F vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 74 | S & F vitreous china squatting pan, \"Orissa\" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S\" trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 75 | S & F 10 litres cap PVC, valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with 32mm dia PVC pipe 600 mm long complete all as specified and directed |
| 76 | S & F health faucet (ABS body) with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower rose and mounting device attached to wall complete all as specified and as directed by Engineer-in-Charge. |
| 77 | M & L for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. |
| 78 | S & F sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed. |
| 79 | Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge. |
| 80 | S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge. |
| 81 | S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge. |
| 82 | S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. |
| 83 | S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge. |
| 84 | S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge. |
| 85 | S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. |
| 86 | S & F 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed. |
| 87 | S & F 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 88 | S & F 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, nickel-chromium plated finished complete all as specified and as directed. |
| 89 | S & F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 90 | S & F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 91 | S & F low density polyethylene pipe (LDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 32 mm including all fittings and fixtures fixed to walls ceiling or in floors complete all as specified and as directed. |
| 92 | S & F 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 93 | Supplying & laying in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 94 | S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 95 | S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge. |
| 96 | S & F 32 mm nominal size, waste coupling of PTMT (half or full threaded), minimum weight 45 grams with including silicone sealant complete all as specified and as directed. |
| 97 | S & F brass, chromium plated toilet paper holder complete all as specified and as directed by Engineer-in-Charge. |
| 98 | M & L for structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn in scantlings and timber fixed complete all as specified and as directed. |
| 99 | M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 -25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed. |
| 100 | S & F sheet glass shelf assembly consisting of 5.50 mm thick glass sheet shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed. |
| 101 | Supplying and laying reinforced concrete pipes with collars, 150 mm internal diameter, class NP3, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed. |
| 102 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 103 | S and F on site LLDPE septic tankconventional typedesigned to carry sewage and sullage water, excavation in any type of soil, PCC(1:4:8) below foundation, vent shaft, connection etc complete for 20 no of user, complete all as specified and directed. |
| 104 | S and F 52 mm thick PVC Partition consisting of 12mm thick both side PVC plastic ply sheet reinforced with frame work made from 40mmX20mm MS tubes. In between two MS tubes, 5mm thick prelam heat moulded \"C\" channel of size 75mmX50mm with feathered edges shall be fixed on the floor, wall and ceiling. Plastic ply opanel shall be inserted in the PVC \"c channel. The first & last MS tube should be errected such that it is inside a PVC \"C channel, in between adjoining plastic panel, 5mm thisk X 75mm width prelam PVC sheet feathered at edges shall be stick on the front & back face using solvent cement complete. |
| 105 | M and L for Construction of Soakage well, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M25 concrete including intercepting chamber, and screen chamber made of brickwork in CM 1:4, RCC cover slab in M-25 /SFRC cover, interconnecting pipes of RRC/DWC complete filled with brick bats of size 1.80 M dia X 3.00 M deep complete all as specified and directed |
| 106 | M & L for capping casing point wiring for one light or one fan or one exhaust fan or bell point controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 107 | M & L for capping casing point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 108 | M & L for capping casing point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 109 | S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed. |
| 110 | S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed. |
| 111 | S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. |
| 112 | S & F modular switch, 1 way, 6 A, 1 module complete all as specified and as directed. |
| 113 | S & F modular bell push, 6A, 1 module, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 114 | S & F (3 pin and 2 pin) combined modular socket outlets (ISI Marked), 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. |
| 115 | S & F modular switch, 1 way, 16 A, 1 module complete all as specified and as directed. |
| 116 | S & F (3 pin and 3 pin) with common earthing pins, combined modular socket outlets, 6A & 16A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. |
| 117 | S and F single pole and neutral enclosures with two pinand earth plug and socket including 1 Nos MCB 20 Amp complete all as spcified and directed. |
| 118 | S & F batten for LED tube light made of CRCA sheet with epoxy powder coated treatment after phosphochromate treatment suitable for 250 V, G 13 Bi pin lamp holder, suitable for 1 X 22 W LED T8 lamp with internal wirings as per catalogue No. LHFYBYPNIA1W022 of Havells or equivalent of Make mentioned under Appendix \"B\" complete all as specified and as directed. |
| 119 | S & F batten including tube light 18 W, Polycarbonate co-extrusion tube housing, wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 140 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1800, lumen efficacy of minimum 100 lumens per watt, low loss constant current driver (>85% efficiencies with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, THD less than 20%, CW available CCT of 5700K, power factor of minimum 0.95, life span of minimum 50000 working hours of Make mentioned under Appendix \"B\" complete all as specified and as directed. |
| 120 | S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. |
| 121 | S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A-63A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. |
| 122 | S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 16 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 123 | S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 4 m³ per minute per watt, maximum power input 50 watt, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, insulation class A for temperature rise, with BLDC motor, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency complete all as specified and directed by Engineer-in-charge. |
| 124 | Supply and fix Heavy duty Exhaust fans 300 mm sweep complete with motor & blades and all required accessories for fixing/hanging Make - Havells Cat Pt No/Model TurboFORCE SP or Equivalent in CG/ORIENT complete all as specified and as directed. |
| 125 | Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. |
| 126 | Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. |
| 127 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. |
| 128 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 129 | M & L for laying of bricks locally available sub class \"B\" bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed. |
| 130 | Supplying & laying in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 131 | S & F hot rolled medium and high tensile structural steel of grade Fe 290 Gde E165 as per IS 15911: 2010 as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles where straps, etc. have screwed, end including keys, cotters, wedges, etc. for timber trusses and similar works complete all as specified and as directed. |
| 132 | M & L for treating the bottom and sides of excavation or soil under plinth protection at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface area complete all as specified and as directed. |
| 133 | M & L for Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., not exceeding 1.5 m high from base complete all as specified and as directed. |
| 134 | Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including cost or royality if any, transportation, taxes etc. for filling including raising earth.Note :(i). Earth required for the item, shall be supplied by contractor, from out side MOD land at his own arrangment. (ii). All cost of procurment of earth including cost of transportation, roualties, taxes etc. shall be deemed to be included in the unit rate quoted by the contractor.(iii). With referance to clause 3.6 of MES schdule Part-II on serial page No. 18 it is clarified that measurement of the above item shall be of finished embarkment/treverse of filled earth after consolidation and 10% deduction shall be made from measured and calculated volume to allow for increase in bulk. |
| 135 | M & L for Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., exceeding 1.5 m but not exceeding 3 m high from base complete all as specified and as directed. |
| 136 | M & L for 3- layer PP-R (Polypropylene random copolymer) pipes 25 mm dia outer dia ,SDR 7.5 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 137 | M & L for 3- layer PP-R (Polypropylene random copolymer) pipes 16 mm dia outer dia ,SDR 7.5 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 138 | M & L for 150 mm internal dia salt glazed stoneware pipes, class SP1 as per IS 651: 2007 laid in trenches and jointed with cement slurry and yarn complete all as specified and as directed. |
| 139 | M & L for concrete bed to glazed stoneware pipes of internal diameter 150 mm, class SP1, laid in trenches of depth upto 1.2 m in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including forming cradles complete all as specified and as directed. |
| 140 | M&L for Vitrified coloured ceramic tiles 8 to 10 mm thick (square/ rectangular) polished,area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc over and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 141 | Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail