North Central Railway-NCR has published Supply Of Smoke, Fire Detection, Alarm System.Smoke, Fire Detection, Alarm System.,Supply, Installation, Testing & Commissioning Of Microprocessor Based Networkable Addressable And Modular Type Of Fire Alarm Control Panel With Display. The Control Panel S. Submission Date for this Tender is 29-09-2022. Alarm Systems Tenders in allahabad Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Smoke, Fire Detection, Alarm System. |
2 | Supply, Installation, Testing & Commissioning of Microprocessor based Networkable addressable and modular type of fire Alarm Control Panel with display. The control panel shall be designed to work on power supply of110V/230V AC +10%-15% with DC battery back up of adequate capacity as per RDSO specification no. RDSO/SPN/217/2021 Ver 3.0 or latest. Including GSM module -01 No. for sending SMS to configured mobile number. The control panel should have provision to provide sufficient input ports for connecting various sensors/detectors along with their interfaces, if any, & shall have provision to provide sufficient output ports for controlling fire extinguishing system,operating/switching of electrical units & shall have provision for remote monitoring in network in single line circuit Without degraded mode for station less than 400 routes & non critical stations. |
3 | Supply, Installation, Testing & Commissioning of addressable heat & smoke multi sensor as per RDSO/SPN/217/2021 Ver 3 or latest. |
4 | Supply, installation, testing and commissioning of Linear Heat Sensing cable/LHD as per RDSO Specification No. RDSO/ SPN/ 217/2021 ver3.0 or latest. |
5 | Supply, Installation, Testing & Commissioning of Linear Heat Sensing Interface Module for Linear Heat Sensing cable/LHD interface module for LHD & all other associated fittings as per RDS0/SPN/217/2021 Ver.3 or latest. |
6 | Supply, Installation, Testing & Commissioning of Aspiration type smoke detector as per RDSO specification No. RDSO/SPN/217/2021 Ver 3.0 or latest. It includes all installation materials excluding CPVC pipe. |
7 | Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable Manual Call Point with inbuilt short circuit fault isolator (as per RDSO /SPN/217/2021 Ver 3.0 or latest) |
8 | Supply, Installation,Testing & Commissioning of Audio visual Alarm(Hooter and Strobe) including its control module As per RDSO specification No. RDS0/SPN/217/2021 Ver 3.0 or latest |
9 | Supply, Installation, Testing & Commissioning of Fire survival integrity cable 2C X 1.5 sqmm 1000V rated (Armoured) as per RDSO/SPN/217/2021 Ver 3.0.or latest. |
10 | Supply, Installation, Testing & Commissioning of CPVC pipe and all other associated fittings. As per RDSO specification No. RDS0/SPN/217/2021 Ver 3.0 or latest. |