| 1 | Outdoor O. F. Cable 6 Core SM |
| 2 | 24 Port Fully loaded LIU Rack mountable |
| 3 | 6 Port Fully loaded LIU Rack mountable |
| 4 | LC to SC Patch cord. SM |
| 5 | Cat6 4 Pair UTP Cable: 23 AWG |
| 6 | Cat 6 STP Out door Cable |
| 7 | Cat6 Information outlet |
| 8 | Face plate Singlex.- Cat6 |
| 9 | 3 x 3 Surface mount box for Cat6 Outlet |
| 10 | Cat6 patch cord,3 mtr |
| 11 | Cat6 patch cord, 1 mtr |
| 12 | Cat6 patch panel 24 port Fully Loaded |
| 13 | 27U Floormount Rack with Accessories |
| 14 | 6U Wallmount Rack with Accessories |
| 15 | Supply of Cable Route Marker with Angle Iron Leg 2 ft with painting |
| 16 | Supply of 25mm ISI PVC Conduit- Ivory |
| 17 | Supply of 32 mm HDPE Pipe |
| 18 | 100X50 DLP Trunking with accessories |
| 19 | 50X50 DLP Trunking with accessories |
| 20 | 1.5\"/ 2\" GI Pipe ISI Approved |
| 21 | 3\"/ 3.5\" GI Pipe ISI Approved |
| 22 | Router with 2x GE Enabled WAN (1000/100/10 Base T) with 2 RJ 45 with all acessories with 5 year 24X7 support |
| 23 | Fully Managed 24 Port Network Switch with minimum 4* 1/10G SFP+ Uplink with 5 year 24X7 support pack |
| 24 | Wireless-N Access Point with 5 year 24X7 support pack |
| 25 | Power Injector for AP |
| 26 | 1G SFP Module for Access Switches (SM) |
| 27 | Supply of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays /pipes/ etc. including supply and fixing of necessary clamping materials. 2 X 16 Sq.mm , 415 V |
| 28 | 4 X 16 Sq.mm , 415 V |
| 29 | Supply of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size,Al-Cu strip for termination of cables etc.2 X 16 Sq.mm , 415 V |
| 30 | 4 X 16 Sq.mm , 415 V |
| 31 | Supply of 63A Phase Selector |
| 32 | Supply of 4 way double door TPN VDB |
| 33 | Supply of 3 Pole Enclosure |
| 34 | Supply of 2 Pole Enclosure |
| 35 | Supply of 12 way SP DB |
| 36 | Supply of 8 way SP DB |
| 37 | Supply of 4 way SP DB |
| 38 | Supply of 2 PoleIsolator40A |
| 39 | Supply of 2 Pole ELCB 40A 100ma Leakage |
| 40 | Supply of 4 Pole 63A MCCB |
| 41 | Supply of 4 Pole 40A MCCB |
| 42 | Supply of 4 Pole 63A MCB |
| 43 | Supply of 3 Pole 63A MCB |
| 44 | Supply of 4 Pole 40A MCB |
| 45 | Supply of 3 Pole 40A MCB |
| 46 | Supply of 2 Pole MCB 40A |
| 47 | Supply of 1 Pole MCB 40A |
| 48 | Supply of 1 Pole MCB 16A |
| 49 | Supply of 1 Pole MCB 6A |
| 50 | Supply of 1 nos of 6sq mmPVC insulated Copper Wire |
| 51 | Supply of 2 nos of 4 sq mm and 1 nos of 2.5 sq mm PVC insulated Copper Wire |
| 52 | Supply of 2 nos of 2.5 sq mm and 1 nos of 1.5 sq mm PVC insulated Copper Wire |
| 53 | Supply of 2 X 10 SWG Bare Copper |
| 54 | Supply of 3 nos 6Asocket controlled by 2 switch |
| 55 | Supply of 2 nos of 6A socket controlled by 1switch |
| 56 | Supply of 1 nos of 6A socket controlled by 1switch |
| 57 | Supply of 1 nos of 16A socket controlled by 1switch |
| 58 | Supply of 20 mm PVC Conduit accessories |
| 59 | Supply of Exhaust Fan - 12\" |
| 60 | Supply of All materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987 |
| 61 | Supply of GI/Cu earthing conductors inclusive of providing earthing terminations and bracing of the terminations using necessary clamps, screws and bolts, PVC sleeves, etc. 25x6 Cu strip |
| 62 | Laying of OF Cable through PVC Conduit/ HDPE Pipe |
| 63 | Laying of OF Cable through GI Pole using stay wire |
| 64 | Splicing of OFC |
| 65 | Termination of LIU |
| 66 | Laying of 4 Pair UTP Cable Cat6 /STP |
| 67 | Fixing and termination of Information outlet with SMB- Cat6 |
| 68 | Fixing and port termination of patch panel- Cat 6 |
| 69 | Fixing & Dressing of Floormount Rack |
| 70 | Fixing & Dressing of wallmount Rack |
| 71 | Laying of 100X50 DLP trunking |
| 72 | Laying of 50X50 DLP trunking |
| 73 | Laying of 25 MM PVC Conduit |
| 74 | Laying charge for GI Pipe |
| 75 | Fixing of Access point |
| 76 | Digging, Laying of HDPE/Water Pipe in Hard Soil / Tar-Road / Concrete Excavation/Trenching, Baked-Brick- Layering, Refilling & Restoration/Resurfacing, upto 600mm depth.(For laying of UTP/OFC) |
| 77 | Fixing of Cable Route Marker |
| 78 | Laying of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays /pipes/ etc. including supply and fixing of necessary clamping materials. 2 X 16 Sq.mm , 415 V |
| 79 | 4 X 16 Sq.mm , 415 V |
| 80 | Termination of all materials and termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size,Al-Cu strip for termination of cables etc. 2 X 16 Sq.mm , 415 V |
| 81 | 4 X 16 Sq.mm , 415 V |
| 82 | Fixing of 4 way double door TPNVDB |
| 83 | Fixing of 3 Pole Enclosure |
| 84 | Fixing of 2 Pole Enclosure |
| 85 | Fixing of 12 way SP DB |
| 86 | Fixing of 8 way SP DB |
| 87 | Fixing of 4 way SP DB |
| 88 | Fixing of 2 PoleIsolator40A |
| 89 | Fixing of 2 Pole ELCB 40A 100ma Leakage |
| 90 | Fixing of 4 Pole MCCB 63A |
| 91 | Fixing of 4 Pole MCB 40A |
| 92 | Fixing of 4 Pole MCB 63A |
| 93 | Fixing of 3 Pole MCB 63A |
| 94 | Fixing of 4 Pole MCB 40A |
| 95 | Fixing of 3 Pole MCB 40A |
| 96 | Supply of 2 Pole MCB 40A |
| 97 | Fixing of 1 Pole MCB 40A |
| 98 | Fixing of 1 Pole MCB 16A |
| 99 | Fixing of 1 Pole MCB 6A |
| 100 | Laying of 1 nos of 6sq mmPVC insulated Copper Wire |
| 101 | Laying of 2 nos of 4 sq mm and 1 nos of 2.5 sq mm PVC insulated Copper Wire |
| 102 | Laying of 2 nos of 2.5 sq mm and 1 nos of 1.5 sq mm PVC insulated Copper Wire |
| 103 | Laying of 2 X 10 SWG Bare Copper |
| 104 | Fixing of 3 nos 6Asocket controlled by 3 switch |
| 105 | Fixing of 2 nos 6Asocket controlled by 2 switch |
| 106 | Fixing of 1 nos of 6A socket controlled by 1switch |
| 107 | Fixing of 1 nos of 16A socket controlled by 1switch |
| 108 | Laying of 20 MM PVC Conduit accessories |
| 109 | Fixing of Exhaust Fan - 12\" |
| 110 | Fixing of All materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987 |