Sl. No. | Item Description |
1 | Earth Work inexcavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I |
2 | Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B) |
3 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
4 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume) |
5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up tp plinth level 1:4:8 (1 cement :4 coarse sand (Zone -III) :8 graded stone aggregate 40 mm nominal size) |
6 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement:1½ coarse sand:3 graded stone aggregate 20 mm nominal size) |
7 | R C CWORK |
8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying butexcludingthecostofcentering,shuttering,finishingandreinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). |
9 | All works uptp plinth level |
10 | All works above plinth level upto floor V level |
11 | Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 (Only valid for sAlL & TATA Steel |
12 | Providing Tor steel reinforcement of 10mm. Dia. bars as per approved design and drawing -do- -do- |
13 | Providing Tor steel reinforcement of 12mm. Dia. bars as per approved design and drawing -do- -do- |
14 | Providing Tor steel reinforcement of 16mm. Dia. bars as per approved design and drawing -do- -do- |
15 | Providing Tor steel,reinforcement of 20mm, 25mm, 8mm, 32mm dia bars as per approved design and drawing -do- -do- 20125 mm dia TMT bar Fe 500 (Only valid for SAIL & TATA Steel) JSPL, and Vizag Steel) |
16 | Centering and shutteing including struting, propping etc and removal of form for |
17 | Foundations, footings, bases for columns, etc for mass concrete |
18 | Walls ( any thickness) including attached pilasters, butteresses, plinth and string course etc |
19 | Suspended floors, roof , landings , balconies and access platform |
20 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
21 | Columns, Pillars, Piers, abutments, Posts and struts |
22 | Stairs, ( excluding landings ) expept sprial staircase |
23 | Vertical and horizontal fins individuaaly or forming box louvers band, facies and eaves boards |
24 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).uspended floors, roofs, landing, beams and balconies (Plan area to be measured) All floors slabs:( floor to floorHt 3.6 m) |
25 | BRICK WORK |
26 | providing designation 75 B brickwork in C M ("1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l. |
27 | Providing Designation 100AB/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
28 | Providing designation 112 mm thick reinforced designation 100 A brick work vuith fly ash lirne brick (FLAG)confirming to lS 12894-1990 (9"x4"5"x3" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/|. |
29 | Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary |
30 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
31 | WOOD WORK |
32 | Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pebuilding specrfication and direction of E/l. |
33 | Supplying fitting and fixing 35mmthick soltd core type decorative double leaf flush door sltutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pebuilding specrfication and direction of E/l. |
34 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
35 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
36 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
37 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
38 | STEEL WORK |
39 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Weight @ 12 kg/sqm |
40 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges,jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
41 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately |
42 | Supplying,frtting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/1 Wt @ 15Kg / sqm |
43 | Supplying fitting and fixing glass panes including supplying putty, beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/1. |
44 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
45 | Providing and fixing ball bearing for rolling shutters. |
46 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area |
47 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured). |
48 | FLOORING WORK |
49 | providing and laying, Doublecharge vitrified floor tiles in differentsizes (thickness to bespecified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with whitecement and matching pigments etc., complete Size of tile 600x600 mm |
50 | Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
51 | Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
52 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
53 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
54 | FLOORING |
55 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
56 | Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
57 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
58 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
59 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
60 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge |
61 | Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
62 | Tremix Flooring Work |
63 | Extra for vaccum dewatering the concrete floors using TREMIX or equivalent over P.C.C layer i/c finishing the top surface to required level/ slope and grade with ugh / polish finish using power trowels (both fan & disc) of standard make including curing, cutting of groove of grid size 4m x 4mwith, mixing of nonmetallic hardening compound (3.0 Kg/Sqm of Fosroc or approved make ) ,cutting of VDF floor with Diamond Saw System (disposal of debris to be included in the quoted rate)as per specification etc. complete as per specification and drawing. (Maximum thickness of RCC flooring shall be of 300 mm) At all heights / depths and levels. |
64 | ROOFING & WATER PROOFING WORK |
65 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
66 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
67 | Roof/Terrace Water proofing: |
68 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
69 | Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
70 | Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
71 | After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
72 | Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
73 | The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
74 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
75 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
76 | Provrding and filling of Groove between 25 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent |
77 | FINISHING WORK |
78 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
79 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
80 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
81 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
82 | Finishing walls with Acrylic Smooth exterior paint of required shade,New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
83 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour. |
84 | ALUMINIUM WORK |
85 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) For fixed portion @ 6KG/SQM |
86 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) For opnable portion @ 6KG/SQM |
87 | MISCELLANEOUS WORK |
88 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
89 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
90 | Goods Lift ( Capicity 1 Ton) Speed in m/sec.0.5 |
91 | Providing and Laying epoxy flooring 2mm to 3mm thick acid resistant coating, chemical resistant coating, polyurethane flooring, anti bacteria polyurethane wall coating for sterilizing the environment of hospitals. |
92 | CARRAIGE OF MATERIALS |
93 | SAND(UPTO 36KM LEAD) |
94 | CHIPS(UPTO 22KM LEAD) |
95 | BRICKS (UPTO 8KM LEAD) |
96 | PLUMBING |
97 | SANITARY INSTALLATIONS |
98 | Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I. (ii) E.W.C. with "S" trap (b) 10 lit. low level PVC Cistem |
99 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
100 | Supplying fitting and fixing white glazed fire’s clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P.brass waste with C.P.brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/I. (i) Kitchen sink 600 mm x 450 mm x 250 mm |
101 | Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I. |
102 | Providing and fixing N.P/C.P. brass /P.V.C. porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of Engineer - in -Charge. (c) 150mm dia P.V.C shower |
103 | (b)Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. (i) 600mm x 450mm size |
104 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitionsby cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
105 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
106 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
107 | Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms |
108 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 |
109 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
110 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore |
111 | Providing and fixing toilet paper holder : C.P. Brass |
112 | INTERNAL DRAINAGE INSTALLATIONS |
113 | Supplying fitting and fixing H.C.I. pipes with ear of approved make confirming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars,lead and yarn for making lead caulked joints, cutting pipes to size including earth work or scaffolding where necessary etc. all complete as per specification and direction of E/I. |
114 | (a) 100 mm dia |
115 | (b) 75 mm dia |
116 | Supplying and fixing H.C.I. fittings of approved make confirming to I.S.S. 1729 including supplying nails and bobines lead and yarn from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I. |
117 | (A) H.C.I. single junction with door but without ear except socket |
118 | (i) 100 mm dia(wt. 10.5 Kg. app.) |
119 | (B) H.C.I Heal rest bend |
120 | (i) 100 mm dia(wt. 5.5 Kg. app.) |
121 | (C) 100 mm dia H.C.I. "P" Trap with |
122 | Anti Syphonage Horn (wt. 8.5 kg app.) |
123 | (D) H.C.I double junction with doorand ear |
124 | (i) 100 mm dia(wt. 15.5 Kg. app.) |
125 | (E) H.C.I. double inverted Jn. |
126 | (100 mm x 50 mm x 50 mm size) |
127 | (F) H. C. I. offsets with ear |
128 | (i) 100 mm dia (wt. 6 kg. app.) |
129 | (G) H.C.I. Bend with door and ear |
130 | (i) 100 mm dia (wt. 6.5 kg. app.) |
131 | (H) H.C.I. plain bend with ear |
132 | (i) 100 mm dia (wt. 5.5 kg. app.) |
133 | (J) Floor trap with grantings |
134 | (i) 100 mm dia |
135 | (K) Northon patent H.C.I. Cowel |
136 | (i) 100 mm dia (wt. 3.25 kg. app.) |
137 | (L) H.C.I. pass over |
138 | (i) 100 mm dia |
139 | Supplying all tools and labours and cutting chajja, Cornice, for laying H.C.I. pipes and making good the same as per specification and direction of E/I. |
140 | Cutting drain width wise above G.L. for laying H.C.I. pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction of E/I. |
141 | Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I. |
142 | (i) 125 mm dia |
143 | (ii) 250 mm dia |
144 | (v) R.C.C. Chajja |
145 | Supplying materials and labour for painting the exposed H.C.I. pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. |
146 | (c) 100 mm dia |
147 | (b) 75 mm dia |
148 | Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. |
149 | For 100mm dia. Pipe |
150 | For 75mm dia. Pipe |
151 | 100mm inlet and 100mm outlet |
152 | Providing and fixing G.I. Pipes completewith G.I. Fittings and clamps.includingcutting and making good the walls etc.required for waste connection from W.B. , A.S.P., Sump Rising main etc. Complete. |
153 | 32 mm nominal bore |
154 | 40 mm nominal bore |
155 | 50 mm nominal bore |
156 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved qaulity: |
157 | 32 mm nominal bore |
158 | 40 mm nominal bore |
159 | 50 mm nominal bore |
160 | Providing and fixing PTMT grating of approved quality and colour. |
161 | 125 mm nominal dia with 25 mm waste hole |
162 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size)alround 100mm dia. SW / CI / waste pipes including bed concrete as per standard design |
163 | Providing, fixing, testingand commissioningof UPVC SWR pipe type "B" conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, "Y", offset, cleaning pipe door, clamps etc. conforming to IS:14735-1999 and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type "B". The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint as required/applicable. |
164 | (a) 100 mm dia |
165 | (b) 75 mm dia |
166 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
167 | WATER SUPPLY INSTALLATIONS |
168 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work -Exposed on Wall |
169 | 15 mm nominal outer dia pipes |
170 | 20 mm nominal outer dia pipes |
171 | 25 mm nominal outer dia pipes |
172 | 32 mm nominal outer dia pipes |
173 | 40 mm nominal outer dia pipes |
174 | 50 mm nominal outer dia pipes |
175 | Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. |
176 | EXTERNAL WORK |
177 | Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks |
178 | Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. All kinds of soil (ii) For classification of soil item-B |
179 | Providing and fixing square mouth SW gully trap grade ‘A’ complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design.(COVER MIN. 4.5 KG & FRAME MIN.2.7 KG ) 150x100mm size P type With FPS bricks |
180 | Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. |
181 | 150 mm dia RCC pipe |
182 | 250 mm dia RCC pipe |
183 | 300 mm dia RCC pipe |
184 | Providing and laying in position cement concrete of grade excluding the cost of centering and shuttering - all work up to plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded ston aggregate 40 mm nominal size) |
185 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
186 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
187 | For pipes 100 to 250 mm diameter |
188 | Domestic Water lifting pumps : |
189 | Flow Rate/Capacity - 30 LPM |
190 | Pumping Head-35 m |
191 | 1 Set = 2 Nos. pump (1 working+1 standby) |
192 | Approx H.P.-2 HP or as per manufacturer recommendation. |
193 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
194 | FIRE FIGHTING WORKS |
195 | FIRE HYDRANT AND PIPING FOR FIRE FIGHTING SYSTEM |
196 | Supplyingandfixingsingleheadedinternalhydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheelISI marked conformingtoIS5290(Type-A)withblank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
197 | Supplying andfixing first-aidHoseReelwithMS constructionspraypaintedinpostofficered, conformingtoIS884completewiththefollowingas required. (INTERNAL FIRE FIGHTING) |
198 | 20mmnominalinternaldiawaterhosethermoplastic (Textile reinforced) type -2 as per IS: 12585 |
199 | 20mmnominalinternaldiagunmetalglobevalve& nozzle. |
200 | Drum and brackets for fixing the equipmets on wall. |
201 | Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
202 | 30 m |
203 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipewith63mmdiamaleandfemalecouplingsduly boundwithGIwire,rivetsetc.conformingtoIS636 (type-A) as required : Gun Metal |
204 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter sizenozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal |
205 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI markedcompletewithnuts,bolts,washers,gaskets conforming to IS 13095 of following sizes as required : |
206 | 100 nominal bore |
207 | 150 nominal bore |
208 | Providing,laying,testing&commissioningof "C"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
209 | Threaded joint upto 50mm diameter pipe. |
210 | Welded joint above 50mmdiameter pipe. |
211 | 25 mm nominal bore (class C) |
212 | 32 mm nominal bore (class C) |
213 | 40 mm nominal bore (class C) |
214 | 50 mm nominal bore (class C) |
215 | 65 mm nominal bore (class C) |
216 | 80 mm nominal bore (class C) |
217 | 100 mm nominal bore (class C) |
218 | 150 mm nominal bore (class C) |
219 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
220 | 50mm dia |
221 | 65mm dia |
222 | 80 mm dia |
223 | 100 mm dia |
224 | 150 mm dia |
225 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
226 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
227 | 65 mm dia |
228 | 80 mm dia |
229 | 100 mm dia |
230 | 150 mm dia |
231 | Providing,laying,testing&commissioningof"B"class heavydutyG.I.pipeconformingtoIS1239including welding,fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two ormorecoatsofsyntheticenamelpaintofrequired shade complete as required:80mm |
232 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
233 | 2 way-100 mm dia M.S. Pipe. |
234 | 4 way - 150 mm dia M.S. Pipe. |
235 | SPRINKLER SYSTEM |
236 | Providing and fixing testing and commissioning of 15 mm size quartzoid bulb type sprinklers. Set to operate at |
237 | Providing, fixing, testing & commissioning of 15mm diaquartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : |
238 | Pendent Sprinkler |
239 | side wall sprinkler |
240 | Providing and fixing flow switch in following sizes M.S pipe including connection etc as required. |
241 | 100mm dia |
242 | 150mm dia |
243 | FIRE EXTINGUSHER |
244 | Providing, storing, handling, shifting, installation, testing and commissioning of portable fire Extinguishers as described below: |
245 | 4.5 kg carbon dioxide extinguisher, IS marked, with high pressure discharge tube, horn, control valve, CCE approved cylinder |
246 | 6 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers |
247 | FIRE PUMPS |
248 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
249 | (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
250 | b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-"F" insulation, conforming to IS-325. |
251 | (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
252 | (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
253 | 450 lpm at 35 m Head |
254 | ELECTRICAL WORK |
255 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C |
256 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required. |
257 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
258 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
259 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required |
260 | CIRCUIT / SUBMAIN WIRING |
261 | 2x1.5sq mm + 1x1.5 sq mm earth wire |
262 | 2x2.5sq mm + 1x2.5 sq mm earth wire |
263 | 2x6 sq mm + 1x6 sq mm earth wire. |
264 | 4x2.5sq mm + 2x2.5 sq mm earth wire |
265 | 4x6 sq mm + 2x6 sq mm earth wire. |
266 | 4x10 sq mm + 2x6 sq mm earth wire. |
267 | 4x16 sq mm + 2x6 sq mm earth wire. |
268 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
269 | Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
270 | 20mm dia |
271 | 25mm dia |
272 | 32mm dia |
273 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
274 | 5/6 amps one way switch |
275 | 15/16 amp one way switch |
276 | 5/6 amp 3 pin socket outlet |
277 | 5/16 amp 6 pin socket outlet |
278 | TV anteena Socket Outlet |
279 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
280 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
281 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
282 | 1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet. |
283 | 4/5 Module (78mm x140mm x 50mm) |
284 | 6 Module (78mmX205mmx50mm) |
285 | Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required. |
286 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
287 | Supplying and fixing Dingdong sound call bell single phase, 230 volts, complete as required. |
288 | Installation, testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted. copper conductor single core cable and earthing etc. as required. |
289 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required. |
290 | Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as required. |
291 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
292 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 WayDouble Door |
293 | Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door Horizontal Type |
294 | Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA"C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. |
295 | 6 / 32 Amp Single Pole |
296 | 40 Amp DP |
297 | 40 Amp TPN |
298 | Supplying and fixingSingle pole blanking plate in the existing MCB DBcomplete etc. as required. |
299 | Supplying and fixing of following rating double pole ( Single pole & neutral),240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required. 40 Amps |
300 | Providing and fixing M.V. danger Notice plate of 200mm x 150 mmof made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird |
301 | Providing and fixing H.T. danger Notice plate of 250mm x 200 mmof made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird |
302 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
303 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
304 | Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. |
305 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
306 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
307 | Providing and fixing of lighting conductor finial made of 25 mm dia 300 mm long, GI tube having single prong at top with 85 mm dia 6mm thick G.I Base plate including hole etc. as required |
308 | Providing and fixingGI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. ( for Horizental Run) |
309 | Providing and fixingGI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. ( for Vertical Run) |
310 | Providing and fixing testing Jointing made of20mmx 3mm thick G.IStrip 125 mm Long. With 4 nos of G.I bolts. Nuts chuck nuts and spring washers etc. as required |
311 | Providing and LayingG.I tape 32mm x 6mmfrom earth electrode directoly in ground as required. |
312 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
313 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
314 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
315 | INSPECTION CHAMBER: |
316 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : |
317 | Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets. |
318 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
319 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
320 | 1 run of cable |
321 | 2 run of cable |
322 | 3 run of cable |
323 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
324 | Upto 35 sq. mm |
325 | Above 35 sq. mm and upto 95 sq. mm |
326 | Above 35 sq. mm and upto 95 sq. mm |
327 | Above 185 sq. mm and upto 400 sq. mm |
328 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
329 | Upto 35 sq. mm |
330 | Above 35 sq. mm and upto 95 sq. mm |
331 | Above 95 sq. mm and upto 185 sq. mm |
332 | Above 185 sq. mm and upto 400 sq. mm |
333 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
334 | Upto 35 sq. mm (clamped with cable tie) |
335 | Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie) |
336 | Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie) |
337 | Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie) |
338 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
339 | 2 x 6 sq. mm (19mm) |
340 | 3½ X 185 sq. mm (57mm) |
341 | 4 X 10 sq. mm (25mm) |
342 | 4 X 16 sq. mm (28mm) |
343 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm wide x 50 mm depth x 1.6 mm thickness. |
344 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm wide x 50 mm depth x 1.6 mm thickness. |
345 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm wide x 50 mm depth x 1.6 mm thickness. |
346 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm wide x 50 mm depth x 1.6 mm thickness. |
347 | 11 KV END TERMINATION: |
348 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 240 Sqmm, 11KV XLPE |
349 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm |
350 | FIRE ALARM SYSTEM (ADDRESSABLE TYPE) AND PA SYSTEM |
351 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
352 | Two Loop Panel. |
353 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
354 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required. |
355 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
356 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
357 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
358 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing) |
359 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
360 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
361 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
362 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
363 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. |
364 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
365 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
366 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm |
367 | SUBSTATION WORK |
368 | TRANSFORMER |
369 | TRANSFORMER Design, manufacture, supply, installation, testing and commissioning of 160 KVA, 11 KV /0.415 KV, 3 phase, 4.5 % impedance, 50 Hz delta/star-11 connected, outdoor type, copper wound transformer, oil immersed ONANcooled, completewithall fittings such as oil conservator, silica gel breather, thermometer, explosion vent with off Load Tap changingarrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-) 10% in steps of 2.5% each, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, weather proof Marshalling Box,lifting lugs, firstfilling of oil, weather proof H.T/L.T cable box etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. The Transformer losses should confirm to IS - 1180 Part-1 (2014) with energy efficiency level 2 [0.67 KW at 50% load & 1.95 KW at 100% load shall not exceeds by 5.0% (@ 11 KV) of the maximum total loss values. a) 160KVA |
370 | DIESEL GENERATING SET |
371 | Supply,Installation,testing and Commissioning ofSilent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 14 / 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. |
372 | Diesel Engine - |
373 | Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. |
374 | Instrument Panel - Engine mounted Instrument Panel fitted withand having digital display for followings : |
375 | Start stop switch with key |
376 | Water temperature indication |
377 | Lubrication oil pressure indication. |
378 | Lubrication oil temperature indication. |
379 | Battery charging indication |
380 | RPM indication |
381 | Over speed indication |
382 | Low Lube oil trip indication |
383 | Engine hours indication |
384 | Alternator- |
385 | Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required. |
386 | Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer. |
387 | Inbuilt Fuel tank ofstandard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete. |
388 | Daily service Fuel tank of990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system,level indicators and all standard accessories etc. as required. |
389 | Exhaust Silencer - Exhaust manifold with residential silencer. |
390 | The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system. |
391 | Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 24 Volts suitable nos. lead acid type batteries of suitable AH. |
392 | Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications. |
393 | 160 KVA |
394 | Supply, Fixing, testing and Commissioning of Exhaust gas piping system ofClass `B" MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with rock wool insulation of minimum 75mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil.The measurement shall be doneon the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will gowell above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) |
395 | (Note - Final size of exhaust pipe will beconfirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval)100 mm dia (wall thickness - 4.5 mm) |
396 | Supply & fixing of SSBellow of following diameter 100 mm dia |
397 | Supply & fabrication ofD G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MSangle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation. |
398 | ELECTRICAL PANELS |
399 | MAIN L.T. PANEL |
400 | Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioningof 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel with AMF, floor mounting, dust & vermin proof, front operatedconstruction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required. |
401 | All Incoming / bus coupler / Outgoings ACB"s shall have inbuiltmicroprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site. All ACB shall be supplied with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947 |
402 | All incoming & outgoing MCCB"s shall be microprocessor based withO/L & S/C and E/F protection. |
403 | All MCCB"s shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L &S/Ctrip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. |
404 | The breaking capacity specified for all ACB"s and MCCB"s breakers is Ics value (service rating). |
405 | The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, cast resin type CT"s & PT"s, etc. Separate CT"s shall be provided for protective and measuring system and for APFCR of capacitor bank with suitable VA. |
406 | Each section ofPanel shall have door opearted light of sufficent lux to illumunate that section & each section of capacitor, buscoupler, transformer and DG incomers shall have exhaust fans for ventilation purpose. |
407 | AllEnergy Analyser / TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication. |
408 | INCOMERS from 1 Nos. 160 KVA T/F |
409 | 1 No. 315 Amp FP Moulded Case Circuit Breaker & 1 No 315 Amp 4 Pole Contactor. |
410 | Protection releases / relays, Metering & Accessories for each Transformer incomers |
411 | Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA) |
412 | Over Voltage / Under Voltage relay / release (3 phase) with timer. |
413 | Trip Circuit Supervison relay. |
414 | TNC switch. |
415 | Auto manual selector switch. |
416 | 1 nos. 0-500 volt range digital type voltmeter with selector switch |
417 | 1 set of 3 CT"s of ratio 300/5A, Class 1.0 accuracy 15 VA burden for metering. |
418 | 1 set of 3 CT"s of ratio 300/5A, Class 1.0 accuracy 15 VA burden for APFCR. |
419 | 1 set - 415 / v3 / 110 / v3Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse. |
420 | 1 no. CT"s of ratio 300/5A, Class 5P10 for protection. |
421 | 1 no. 0-300 Amprange digital type ammeter with selector switch. |
422 | Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485communication port for communication / report generation. |
423 | Power factor meter. |
424 | Frequency meter. |
425 | 3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons. |
426 | 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB. |
427 | INCOMERS from 1Nos. 160 KVA D G sets |
428 | 1 No. 315 Amp FP Moulded Case Circuit Breaker & 1 No 315 Amp 4 Pole Contactor. |
429 | Protection releases / relays, Metering & Accessories for each D G set incomers |
430 | Reverse power relay. |
431 | TNC switch. |
432 | Auto / manual / test selector switch |
433 | 1 Set - 415/v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB. |
434 | 0-500 volt range digital type voltmeter with selector switch |
435 | 1 set - 3 CTs of ratio :300/5A , Class 1.0 accuracy 15 VA each burdenfor metering. |
436 | 1 set - 3 CTs of ratio :300/5A , Class 5P20 accuracy 20 VA each burdenfor protection. |
437 | 0-600 Amprange digital type ammeter with selector switch. |
438 | Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485communication port for communication / report generation. |
439 | Frequency meter. |
440 | Power Factor meter. |
441 | 1No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing. |
442 | 3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons. |
443 | 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB. |
444 | 12 window annunciator with accept / reset / test push buttonfor each DG set for following indications and alarm :set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares. |
445 | Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop. |
446 | Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps. |
447 | D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out. |
448 | 1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (160 KVA) |
449 | Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same. |
450 | The ACB shall be electrically and mechanically interlocked with the bus coupler and Transformer incomers. |
451 | 1 nos. 63 amp FP MCCB (25 KA) with KWH meter for Solar Incomer. |
452 | BUS BARS |
453 | 400 AMP, TPN busbars of aluminium alloy as per SLD. |
454 | A M F logic / Panel - |
455 | Automatic mains failure control including auto by-pass suitable for silent type DG set complete with relays, timers set of CTs for metering & proyection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH , KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: |
456 | Auto/Manual/Test/Off selector switch |
457 | D G Start / stop push button, emergency stop push button, |
458 | 2 Nos. over voltage relay , 2 Nos. reverse power relay and 2 Nos. under voltage relay. |
459 | 3 sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering |
460 | Energy analyser unit to indicate current voltage frequency power factor and KWH |
461 | Indicating lamps for Mains ON/OFF, DG supply ON/OFF, DG running, DG fails to start. |
462 | Fuse for instruments |
463 | Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. |
464 | Main supply failure monitor |
465 | Supply failure timer |
466 | Restoration timer |
467 | Control unit with three impulse automatic engine start/stop and failure to start lockout. |
468 | Impulse counter with locking and reset facility. |
469 | ON/OFF/Control circuit switch with indicator |
470 | Audio/Vedio annunciation for |
471 | (i) High water temperature |
472 | (ii) Low lubricating oil pressure |
473 | (iii) Engine over speed |
474 | (iv) Engine fails to start |
475 | (v) Full load/ maximum load warning |
476 | OUTGOINGS: |
477 | 01 Nos. 125 Amp TP MCCB (25 KA) |
478 | 07 Nos. 63 Amp TP MCCB (25 KA) |
479 | 06 Nos. 40 Amp TP MCCB (25 KA) |
480 | Main LT Panelas described above |
481 | AUTOMATICPOWERFACTORCORRECTIONPANEL(CAPACITOR PANEL) |
482 | Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type 60 KVAR A P F C Panel with consisting of 5 / 10 KVAR (at 415 Volts rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operatedconstruction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . |
483 | All out going MCCB"s shall be thermal-magnetic based with inbuiltO/L & S/C release. |
484 | All MCCB"s shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L &S/Ctrip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link.The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT"s, PT"s, etc. |
485 | AC3 duty contactors should be used for switching individual capacitor banks. |
486 | The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec. |
487 | Each section of capacitor panelshall have Verticle hood & exhaust fans for ventilation purpose. |
488 | INCOMING |
489 | Incomer circuit breaker has been included in the main panel. |
490 | 1 set-3 CTs , ratio 300 / 5A Class 1.0 accuracy 15 VA burden for metering. |
491 | 1Nos- (300 A)digitalAmmeter withselector switch |
492 | Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 9 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work. |
493 | Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit. |
494 | BUS BARS |
495 | 400 AMP,500 Volts, 3 phase 50 HZTPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints. |
496 | OUTGOINGS |
497 | 5 nos.of32AMPS TPN 35 KA MCCB and 40 amps AC3 duty contactor with 10 KVAR heavy duty MPP typeat 415 V capacitor bank(rated Voltage 440 Volts) ,auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. |
498 | 2 no.of16AMPS TPN 35 KA MCCB and 20 amps AC3 duty contactor with 5 KVAR heavy duty MPP typeat 415 V capacitor bank(rated Voltage 440 Volts) , auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. |
499 | Capacitor Panelas described above |
500 | EXTERNAL LIGHTING PANEL (OUTDOOR TYPE) |
501 | Design, Manufacturing, Supply, installation, Testing & Commissioning of Outdoor Type Panel with Front & Back double door, Top canopy, Mounting on Floor M.S. Stand etctotally enclosed free standing type water, moisture, dust and vermin proof Sub Distribution Board made out of 2.0 mm thick CRCA sheet complete with followingequipments, includingammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT"s, internal wiring with suitablesize wires/ cable, interconnection, painting etc as required. |
502 | INCOMING |
503 | 1 No 63 Amp FP Moulded Case Circuit Breaker (25 KA) with 63 Amp 4 Pole Contactor & Timer. |
504 | 1 No. Digital AVF Meter with inbuilt selector switch and CT" & SP MCB. |
505 | 1 Set of phase indicating lamps. |
506 | 1 Set of ON/OFF indicating lamps with SP MCB. |
507 | BUS BARS |
508 | 200 Amp FP aluminium busbar with coloured heat shrinkable sleeve. |
509 | OUTGOING |
510 | 08 Nos. 25 Amp DP MCB(10 KA) |
511 | 03 Nos. 40 Amp DP MCB(10 KA) |
512 | Panel described as above |
513 | Supply of following sizes of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable conforming toIS-7098. (Part-I) 1988. |
514 | 3.5 core,185 sq.mm. |
515 | 4 core,16 sq.mm. |
516 | 4 core,10 sq.mm. |
517 | 3 core,6 sq.mm. |
518 | Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 240 Sqmm, 11 KV XLPE |
519 | Supply Supply & Laying of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming torelevant IS. |
520 | 4 core,2.5 sq.mm. |
521 | 10 core,2.5 sq.mm. |
522 | 12 core,2.5 sq.mm. |
523 | Supply, erection, testing and commissioning of following sizes of TV splitter of aluminium die cast body in suitable size of G.I. Box. 4 way |
524 | Supply, erection, testing and commissioning of following co-axial cable in existing conduit.RG-11 |
525 | Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006. |
526 | Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd. |
527 | SUPPLY OFLIGHT FIXTURES & FANS |
528 | Supply,of 18 Watt LED Light Fixture surface mounted round (Philips Make cat no-SM251C LED20S- 6500 PSU WHLED Light or equivalent). |
529 | Supply of 40 watt LED Tube light fixture with electronic high efficiency electronic driver as complete as required. (Philips Make, Cat No--BN100C LED40S-6500 PSU L120 GR or equivalent). |
530 | Supply of 10W LED Bulk Head Light(Philips make cat no- WT140W LED7S CW PSU S1 PC or equivalent). |
531 | Supply of 10 watt LED Mirror light fixture wall mounted with electronic high efficiency electronic driver as complete as required. (Philips Make, Cat No- BN 021 LED12S 6500 PSU GR or equivalent). |
532 | Supplyof following sizes ofheavy dutyexhaust fan for single phase 230 volt, 50HZ AC supply complete withmotor, blades, frame, bracket, louver/ shutter etc as required. (HavellS Make, Cat No - Ventil Air - DX White or equivalent). 250 mm Exhaust Fan(1500 RPM). |
533 | Supply of following sizes ofceiling fan complete withdouble ball bearing, motor, blades, downrod, canopy, capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required. (Havells Make, Cat No-Efficiencia Neo (BLDC 26 W) or equivalent.) 1200 mm Ceiling Fan |
534 | Supply, Installation, Testing & Commissioningof6 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top70 mm A/F made up of 3 mm thick HT plate and 220x220x12mm base plate and 1000 mm long single arm bracket complete with 4 NosM20 x 700 mmlong " J type " foundation bolts, suitable RCC foundation etc as complete as required. (Make,- Philips / Bajaj / Lokozo). |
535 | Supply, Installation, Testing & commissioning of outdoor type (IP 65) Bollard Light 180 mm dia, 500 mm height made out of cast aluminium, 7 W LED Light with 100 lumen / watt,warm white, stainless steel screw, corrossion & UV resistant coat, including suitable size of CC foundation, grouting bolt, plastering etc as complete as required. (Philips Make, Cat No--BCP150 LED150/WW PSU 220-240V 7043 or equivalent). |
536 | Supply, Installation, Testing & Commissioning of60 Watt LED, Street Light Fitting(IP 66) , made from PDC housing with finless design and high impact resistance (IK08) Polycarbonate cover with integrated, lumen output of minimum 4500lumens and minimum efficacy of 100 Lumen / watt, Colour temperature- 5700K/6000K/6500K, CRI > 80 suitable for operation on 220 Volt, 50 HTZ A.C. supply complete with all accessories as per specifications,including connection- enter connection and earthingetc as required. (Philips Make, Cat No--BRP062 LED 68 CW SLC S1 PSU or equivalent). |
537 | UPS SYSTEM |
538 | Supply, Installation, Testing & Commissioing of 5 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transformer as per specification given in the document with following broad features. |
539 | THD(i) shall be less than 3% in the entire loading range. |
540 | UPS shall carry design output at 40 deg. |
541 | Shall have soft start and hold of for incoming supply. |
542 | Invertor capability to supply 150% load for 5 sec. |
543 | Three Phase Input and Three Phase Output. (Input - 180V - 260V, Single Phase, 2 wire. / Output - 200-220 Volt, Single Phase, 2 Wire.) |
544 | Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. |
545 | Battery shall be external type with rack and suitable for 30 minute backup on 100% load. |
546 | Suitable size of copper cable between UPS and battery bank shall be provided |
547 | UPS described as above |
548 | DATA, TELEPHONE SYSTEM INCLUDING ACTIVE COMPONENTS |
549 | Supply, Installation, Testing & Commissioning ofCat 6, 24 Port Patch Panel |
550 | Supply, Installation, Testing and Comissioning of Cat 6 patch cord 3 feet for rack and user end termination - 1Mtr |
551 | Supply, Installation, Testing and Comissioning of Cat 6 patch cord 7 feet for rack and user end termination - 2Mtr |
552 | Supply, Installation, Testing, Commissioning of Cat 6, Information Outlet (I/O) including G.I. Box and modular cover plate. |
553 | Supply, Installation, Testing and Comissioning of 24U floor mounted Rack with accessories. |
554 | Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module,L-2 Switch, POE. |
555 | Supply, Installation, Testing & Commissioning of EPABX SYSTEM Configuration as Below:- Analog Trunk Line6 Nos. Digital Line2 Nos Analog Extensions 20 Nos. |
556 | Supply, Installation, Testing & Commissioning of Digital Phone for Operator Console |
557 | Supply, Installation, Testing & Commissioning of TypeAnalog Phone with speaker phone, . |
558 | Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable as per technical specification. |
559 | IP CCTV SYSTEM |
560 | Supplying, installation, testing & commissioning of 1080p HD Indoor IP Dome camera with1/3-inch CMOS, Sensor pixels 1920 x 1080, Sensitivity-0.04 lx (color) , Dynamic range 75 dB Wide Dynamic Range (WDR), True day/night, Automatic Electronic Shutter, Video compression H.264 ; M-JPEG, White balance, BLC, H.264 quad-streaming, Motion/tamper/audio detection, Privacy Mask, Lens 3.6 mm lens, 3-axis adjustment (pan/tilt/ rotation), ONVIF Profile S, CE Certified. |
561 | Supplying, installation, testing & commissioning of 5MP 30 fps HD indoor / outdoor IR IP bullet camera with 1/3-inch CMOS, Sensor pixels 2612 (H) x 1980(V), Sensitivity-0.24 lx (color) 0.04 lx (mono) ,IR range 30 mtrs,Dynamic range 70 db, True day/night, Automatic Electronic Shutter, Video compression H.264 MP ; M-JPEG, White balance, BLC, Analog video output,Lens (zoom / focus) 3.6 mm lens, Two-way, full duplex Audio, Audio compression AAC, G.711, L16 ,ONVIF Profile S, CE Certified. |
562 | SITC of IP network recoder with following feature Processor - Dual-core embedded processor . Two-way Talk - 1 channel Input, 1 channel Output, RCA,Video Output - 1 HDMI, 1 VGA , IP Camera Input - 8/16/32Channel IP , Compression - H.264+/H.264/MJPEG,Video Resolution - 2560 × 1920, 2048 × 1536, 1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768 , Hard Disk - 4 SATA Ports, up to 8TB ,Motion Detection - MD Zones: 396 (22 × 18),Recording Mode - Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Camera Blank, Video Loss), Alarm, Stop, Backup Mode - USB Device /Network , Interface Ports - 1 HDMI, 1 VGA, 2 USB(1 USB 2.0 , 1 USB 3.0 ), 1 RS485, 1 RS232, 1 RJ45. |
563 | Supply, Installation, Testing and commissioning of Managable24 port Switch with Power on Ethernet (PoE) enabled, 10/100,RJ45 Access ports with PoE complete as required. |
564 | Supply, installation, testing and commissioning of of 6 TB HDD all accessories complete as required. |
565 | Supply installation and commissioning of 32 inch LED monitor for disply of camera. |
566 | HVAC |
567 | Air Cooled Normal/Inverter Ductable Unit |
568 | Supply, installation, testing & commissioning of Air Cooled Ductable Split Units.The evaporating unit shall be equipped with synthetic fibre filter s, insulated drain pan, safety controls, thermostat, suitable for refrigerant CFC free R 22/32/410A/407C all complete in a unit. The outdoor unit shall have condenser copper coil, fans with motor and drive, scroll compressor, panel, microprocessor with digital display,electronic expansion device etc.The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. Nothing extra shall be paid on any account i.e. refrigerant pipes, drain pipes etc. |
569 | Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness and cabling for all types ofAC units. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection. |
570 | Note: Providing and fixing of Powder coated M.S. angle iron frame work for outdoor unitis also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation. |
571 | 4.0 TR (1600 CFM) Ductable Split Unit |
572 | 5.5 TR (2200 CFM) Ductable Split Unit |
573 | 8.5 TR (3400 CFM) Ductable Split Unit |
574 | 11.0 TR (4400 CFM) Ductable Split Unit |
575 | AIR COOLED SPLIT TYPE SPLIT UNITS AIR-CONDITIONER |
576 | Supplying, installing, testing and commissioning of Air Cooled Invertor Split type wall mounted 5 Star Air conditioners with evaporating unit comprising of cooling coil, blower with motor and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. Nothing extra shall be paid on any account i.e. refrigerant pipes, drain pipes etc. |
577 | Capacity : 1.5 TR |
578 | DRAIN PIPING |
579 | Supply,installation,testing and commissioning of UPVC drain piping complete withfittings, supportsas perspecifications anddulyinsulatedwith6 mmthick closed cell expanded polythene. |
580 | 25 mm ID |
581 | 32 mm ID |
582 | 40 mm ID |
583 | VENTILATION SYSTEM |
584 | Smoke Extraction Fan |
585 | Supply, installation testing & commissioning of Fire Rateddirect drivenAxial flow fan. Each fan shall be complete with casing made from mild steel duly enamel painted, adjustable pitch die cast aluminum impeller (HUB & BLADES), mounting clits, structural frame with blank-off sheet, anchor fastener with vibration isolation pad, bird screen at one sides (entry for supply air and exit for exhaust air) and rated Motor with class-H insulation. Motor shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply. withstarter panel. |
586 | Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order thefans,(a) Noise level @ 3m from Fan shall be less than 78 dBA. with starter panel |
587 | Note:-These fans would be connected to the fire alarm system of the building and would start automatically in case of Fire |
588 | Each fan Capacity 8000 CFM,SP 20 mm wg |
589 | Each fan Capacity 9000 CFM,SP 20 mm wg |
590 | Supply, installation testing & commissioning of direct drivenAxial flow fan. Each fan shall be complete with casing made from mild steel duly enamel painted, adjustable pitch die cast aluminum impeller (HUB & BLADES), mounting clits, structural frame with blank-off sheet, anchor fastener with vibration isolation pad, bird screen at both sides and rated Motor with class-F insulation. Motor shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply. withstarter panel. |
591 | Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order thefans,(a) Noise level @ 3m from Fan shall be less than 78 dBA. with starter panel |
592 | Note:-These fans would be connected to the fire alarm system of the building and would start automatically in case of Fire |
593 | Each fan Capacity 8000 CFM,SP 20 mm wg |
594 | Each fan Capacity 9000 CFM,SP 20 mm wg |
595 | Supply, installation, testing, commissioning of Inline fan with vibration isolators & speed regulator, complete as per specification and drawing. The Motor shall be suitable to run on 1 phase/50 hz/ 220 v electrical power. |
596 | 300 cfm, 10 mm static pressure |
597 | Supply, installation, testing, commissioning of ceiling mounted fan with gravity louvers, vibration isolators & speed regulator, complete as per specification and drawing. |
598 | 300 CFM |
599 | Supply. Installation, testing and commissioning of factory fabricated G.I. Sheet metal ducts with flanges, inbuilt sealant, gasket, supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Duct shall be furnish at sitein "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications. |
600 | 0.63 MM (24 Gauge ) |
601 | 0.80 MM (22 Gauge ) |
602 | 1.00 MM (20 Gauge ) |
603 | 1.25 MM (18 Gauge) Plenum |
604 | Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil of mat finish closed cell nitrile rubber (Class "O" ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications. |
605 | 19 mm |
606 | 25 mm |
607 | Supply and fixing of acoustic lining of supply air duct and plenum withthick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer"s recommended Rubber based Adhesive in a blend of solvents. |
608 | 20 mm |
609 | 25 mm |
610 | Supply. Installation, testing and commissioning of G.I construction Duct/ Volume control Dampers for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification. |
611 | Supply. Installation, testing and commissioning of powder coated extruded aluminum sections grills as per specification. |
612 | Supply. Installation, testing and commissioning of powder coated extruded aluminum section grills with dampers for supply air terminal for air-conditioningas per specification. |
613 | Supply. Installation, testing and commissioning of powder coated extruded aluminum square diffusers with antismudge ring and removable core. |
614 | Supply air with dampers |
615 | Return air without damper |
616 | Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications. 200 mm |
617 | Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification. |
618 | 3-Slot Diffuser |
619 | 2-Slot Diffuser |
620 | Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille. |
621 | 100 mm |
622 | 150 mm |
623 | 200 mm |
624 | Supply. Installation, testing and commissioning of exhaust air/fresh air louvers of powder coated extruded aluminum construction with bird screen, minimum 80 mm deep. |
625 | Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure of suitablefor Duct type Outdoor Unit. |
626 | 40A 4P MCCB(16 KA) |
627 | 63A 4P MCCB(16 KA) |
628 | Supply, laying, testing and commissioningofpower andcontrolcablingasper specification given in the tender. |
629 | A) Power cabling (XLPE insulated Aluminum / Copper conductoras given below armoured / unarmoured cables of 1.1 KV Grade) includingcable end termination with brass compression glands & lugs etc. as per specification. |
630 | Note:- Power cable with earthing shall be made available near indoor / outdoor units. Only termination into HVAC equipment"s (Indoor & Outdoor) shall be done by HVAC Contractor. |
631 | 4C x 10 Sq. mm Copper Conductor (Armoured) For Ductable Unit |
632 | 4C x 6 Sq. mm Copper Conductor (Armoured) For Ductable Unit |
633 | Signage |
634 | Reception Back Wall Signgae Laser Cut 5 mm Acrylic Letters with Pasted over 5 mm Acrylic Sheet with 6 studs4 Feet by 3 Feet |
635 | ReceptionHanging Signge Double Sided Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required 4 Feet by 2 Feet |
636 | Toilet Male Door Signage Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back4 Inch18 Inch by |
637 | Staircase Door Signage Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back4 Inch18 Inch by |
638 | Medical Store Door Signage Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back 4 Inch18 Inch by |
639 | Electrical Room Door Signage Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back 4 Inch18 Inch by |
640 | Lift Lobby Directory Signage Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required 2 Feet by 4 Feet |
641 | Lift Lobby Lift Wall Signage Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required 1 Feet by 2 Feet |
642 | RampHanging Signge Double Sided Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required 4 Feet by 2 Feet |
643 | Medical Store Door Signage Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back4 Inch18 Inch by |
644 | Staircase Door Signage Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back4 Inch18 Inch by |
645 | Medical Store Door Signage Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back4 Inch18 Inch by |
646 | Lift Lobby Directory Signage Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required 2 Feet by 4 Feet |
647 | Lift Lobby Lift Wall Signage Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required 1 Feet by 2 Feet |
648 | Ultrasonic Advanced Rodent Repellent System |
649 | Supply, laying, testing and commissioningofMain Rodent Controller suitable to connect 20 Transducers, each Transducers covering @ 300sft at room area and @ 150sft at false ceiling and false flooring area. |
650 | Supply, laying, testing and commissioningof of Transducers |
651 | Supply, laying, testing and commissioningofWire Bundle - 92 mtr |
652 | Supply, laying, testing and commissioningofStand & Bracket |
653 | Packing & Shipping Ultrasonic Advanced Rodent Repellent all Matrerial. |
654 | Add 18% GST |
655 | Add 1% Labour cess 1% |