Repairs Replacement Of Fire Alarm Panel, Detectors And Connected Works At Rci Technical Area Cpdc And Elsec Under Ge I Rnd Rci Hyderabad , hyderabad-Telangana

Military Engineer Services-MES has published Repairs Replacement Of Fire Alarm Panel, Detectors And Connected Works At Rci Technical Area Cpdc And Elsec Under Ge I Rnd Rci Hyderabad . Submission Date for this Tender is 24-09-2022. Fire Alarm Systems Tenders in hyderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

33678993
Corrigendum : Repairs Replacement Of Fire Alarm Panel, Detectors And Connected Works At Rci Technical Area Cpdc And Elsec Under Ge I Rnd Rci Hyderabad
Open Tender
Indian
Telangana
hyderabad
24-09-2022

Tender Details

Repairs Replacement Of Fire Alarm Panel, Detectors And Connected Works At Rci Technical Area Cpdc And Elsec Under Ge I Rnd Rci Hyderabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
INR 41 Lakhs /-

BOQ Items

Name of Work: REPAIRS/REPLACEMENT OF FIRE ALARM PANEL, DETECTORS AND CONNECTED WORKS AT RCI TECHNICAL AREA, CPDC AND ELSEC UNDER GE(I) R&D RCI, HYDERABAD
Sl. No. Item Description
1S&F in repairs, weather proof Manual Call Point to match various Conventional Type Fire Alarm system, suitable for surface mounting or semi flush mounting, making necessary connection, testing and making good disturbed surfaces complete all as directed. Make: Apollo, Morley, Agni, Securico
2S&F in repairs, weather proof Manual Call Point to match various Addressable Type Fire Alarm system, suitable for surface mounting or semi flush mounting, making necessary connection, testing and making good disturbed surfaces complete all as directed. Make: Apollo, Morley, EST
3S&F in repairs, Electric siren single mounting, horizontal, single phase, AC supply, audible diametrical sound range of 1 KM, power 110 V including testing complete all as specified and as directed.
4S&F in repairs, electrically operated horizontal double mounting siren, 220/250V, single phase, AC supply, audible diametrical sound range of 1.5KM including testing complete all as specified and as directed. Make for item No 3&4: Kheraj, Jaykay, Perfect, National
5S&F in repairs, photoelectric optical use internal pulsing Smoke Detector addressable type complete all as specified and directed. Make: Kartar, Apollo, Morley, GST 5000
6S&F in repairs, Manual Call Point break glass required for Conventional type Fire Alarm Systemcomplete all as specified and directed.
7S&F in repairs, Response Indicator with set of built in tools for indication of detectors, 6V, fixed on walls or within false ceiling with indication complete all as specified and directed. Make: Dekars, Ravel, Fire, Securico, Agni
8S&F in repairs, 24Volts, 8PIN, 24VAC Potential Free Relay with socket in existing Fire Alarm Main Panel complete all as specified and directed.
9S&F in repairs, speaker type electrical Hooter, 8"(20CM), 110V single phase complete all as specified and directed. Make: Kheraj, National, Securico or techno commercially equivalent as approved by GE
10S&F in repairs, Transformer 24-0-24 Volts, 5Amp in existing Fire Alarm main panel complete all as specified and directed. Make: Manish Engineers or techno commercially equivalent as approved by GE
11S&F in repairs, speech auto dialing system suitable for micro controller base, consisting of13key onboard key pad, 3 message, 1 to 40 numbers storage capacity with provision for fire, special and special help complete all as specified and directed. Make: Securico, Falcon or techno commercially equivalent as approved by GE
12S&F in repairs, Assorted fuse 3A, 5A in existing fire alarm panel complete all as specified and directed.
13S&F in repairs, 2core 1.5Sqmm FR PVC insulated, PVC round sheathed, flexible copper conductor cable, 1100Volts, ISI marked complete all as specified and directed.
14S&F in repairs, 2core 2.5Sqmm FR PVC insulated, PVC round sheathed, flexible copper conductor cable, 1100Volts, ISI marked complete all as specified and directed.
15S&F in repairs, 2core 4Sqmm FR PVC insulated, PVC round sheathed, flexible copper conductor cable, 1100Volts, ISI marked including PVC casing & capping with fittings of size 20mm, ISI marked complete all as specified and directed.
16Dismantling and Reprogramming Single loop Fire Alarm main panel/ repeater panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturer"s instructions convenient windows programming software, changing of detector/sensor location, name, address of room, testing for exact fault locations and reconnecting to entire satisfaction of Engineer in Charge complete all as directed.
17All as per item No 16 above for Two loop Fire Alarm main panel board
18Dismantling and Reprogramming microprocessor based Four loop addressable type Fire Alarm main panel/ repeater panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturer"s instructions convenient windows programming software, changing of detector/sensor location, name, address of room, testing for exact fault locations and reconnecting to entire satisfaction of Engineer in Charge complete all as specified and directed. Note for item No 16 to 18: Testing shall be done in the presence of Fire Safety Officer, RCI
19S&F in repairs, Isolator module used for installation where there is problem of Id connection and damage to devices output 16W/12W, voltage 1500VDC/1MA complete all as specified and directed. Make: Apollo, Morley, XP95
20S&F in repairs, 8 Way Wago/Phone PCB terminal block connector in weather proof mild steel junction box including necessary painting and insulation material complete all as specified and directed.
21S&F, in repairs, sealed maintenance free lead acid battery 12Volts 7AH complete all as specified and as directed. Make: EXIDE, AMARON, FURKKAVA
22S&F in repairs, single loop main control panel, microprocessor based addressable type fire alarm control panel with LCD display, event storage with real time clock communication for network/repeater one programmable form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed.
23S&F in repairs, two loop main control panel, microprocessor based addressable type fire alarm control panel with LCD display, event storage with real time clock communication for network/repeater one programmable form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed. Make for item No 22 & 23: Apollo, Notifier, Tata Honeywell, FDX 5000
24S&F in repairs, Four zone main control panel conventional type fire alarm control panel with LCD display, event storage with real time clock communication for network form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed. Make: AGNI, RAVEL, DEKARS, MINIMAX Make of battery for item No 22 to 24: EXIDE, AMARON,FURKKAVA
25Opening the Smoke detector and cleaning of its sensor completely with blower including carrying out smoke test with SOLO A10S Detector Tester to verify the detector is live and refixing complete all as directed. Note: Smoke testing with magnet shall not be permitted. Test results shall be submitted duly signed by all concerned.
26S&F in repairs, photoelectric optical use internal UV/IR Flame Detector addressable type complete all as specified and directed. Make: Notifier, Siemens, Esser
27S&F in repairs, input / output module used for installation where there is problem if ID connection and damage to devices output 16W/12W, voltage 1500DC/1mA complete all as specified and directed. Make: Apollo, Morley, XP95, Notifier
28S&F in repairs, Siren Controller set box with ON/OFF switch with LED indication complete all as specified and directed.
29S&F in repairs, rewinding Electric Siren single mounted, horizontal, single phase, AC, audible diametrical sound range of 1KM, power 110V including testing complete all as directed.
30S&F in repairs, addressable type multi sensor detector with heat and smoke (Photoelectric/Thermal) combination complete all as specified and directed. Make: Apollo, Morley, GST 5000
31S&F in repairs, four loop main control panel, microprocessor based addressable type fire alarm control panel with LCD display, event storage with real time clock communication for network/repeater one programmable form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed. Make: Apollo, Notifier, Tata Honeywell, FDX 5000, Morley Note for item No 22 to 24 and 31: Testing shall carried out in the presence of Fire Safety Officer, RCI. Demonstration and training shall be imparted to department personnel.
32Dismantling and reprogramming single loop card Fire alarm main panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturers instructions convenient window programming software, sensor location, address of room, testing for exact fault location and reconnecting to entire satisfaction of Engineer in charge and as directed.
33Dismantling and reprogramming two loop card Fire alarm main panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturers instructions convenient window programming software, sensor location, address of room, testing for exact fault location and reconnecting to entire satisfaction of Engineer in charge and as directed.
34S&F in repairs, Display card of main fire alarm control panel and repeater panel control panel with LCD display event storage with real time clock communication for network from C relay for fire extensive built in transient protection lamp test facility common fire, supervisory fault LED indication including testing complete all as directed.
35S&F in repairs, PCB main card of Main Fire Alarm control panel and repeater panel control panel with loop, event storage with real time clock communication for network from C relay for fire extensive built in transient protection lamp test facility common fire, supervisory fault LED indication including testing complete all as directed
36Reprogramming of speech auto dialing suitable for controller base 1 to 40 numbers storage capacity with provision of adding to automatic fire alarm system panel programming phone numbers, recording, cable etc., including testing complete all as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail