| 1 | Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 3 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical cum 226 transport including loading, transporting, unloading to approved municipal dumping ground for lead up to 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 4 | Steel reinforcement for R.C.C. work, where not included in thecomplete rate of RCC, including straightening, cutting, bending,placing in position, binding, wastage, overlaps, welded joints,spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect below plinth level. Thermo-Mechanically Treated bars of grade Fe-500D kgor more. |
| 5 | Providing and laying in position cement concrete of specifiedgrade excluding the cost of centering and shuttering - All workbelow plinth level and up to Floor IV level: Unit 6.1.1 1 : 1 ½: 3 ( 1 Cement: 1 ½ coarse sand (zone-Ill) : 3 cumgraded stone aggregate 20 mm nominal size) |
| 6 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer all complete. |
| 7 | 1:5:10 (1 cement : 5 coarse sand (zone-Ill):graded stone aggregate 40 mm nominal size) |
| 8 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours& shade, in skirting, riser ofsteps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 9 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %)total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns. Sheet should have protective guard film of25 microns minimum to avoid scratches during transportation and should besupplied in single length up to 12 metre or as desired by Engineer-in-charge.The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever required. |
| 10 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 11 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 12 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides |
| 13 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 14 | Providing and fixing aluminium die cast body tubular type universal hydraulicdoor closer (having brand logo with ISi, IS : 356 4, embossed on the body, door weight up to 35 kg and door width up to 7 00 mm), with necessary accessories and screws etc. complete. |
| 15 | Providing and fixing 2 ton split AC (hot and cold) LG make. Rate from GeM portal |
| 16 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to fonn grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.9.50.18 mm thick fully perforated calcium silicate board made with sqm Calcareous & Siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rock wool of 48 kg /cum backing. |
| 17 | Providing and fixing Electrical items (schedule items)a. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. |
| 18 | Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required |
| 19 | PVC CONDUIT and MS/GI BOX only for LIGHT/FAN/Call bell point wiring |
| 20 | PVC CONDUIT only for Light point without control |
| 21 | PVC CONDUIT and MS/GI BOX only for 3 pin 15 amp. plug point |
| 22 | Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and makingnecessary connections required to complete the job in all respect up to theentire satisfaction of the Engineer-in-charge of the work. Triple pole MCCB 200 to 250 Amp 25 KA |
| 23 | MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings.MCCB up to 250 A FP |
| 24 | Supply and erection of sheet steel enclosures 1 pole/2 pole/4 pole on walVon existing pedestal complete as required. S.P Enclosure suitable for single pole MCB |
| 25 | Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including makingnecessary connections:- 40 Amp to 63 amp MCB’s for pole |
| 26 | HT Cable 70 mm (4 core- aluminum) |
| 27 | Cat-6cable |
| 28 | LED Light 36 W (2’x2’) (surya) |
| 29 | Ceiling fan 48” (surya) |
| 30 | Telephone set C-11 (Beetel) |
| 31 | Ding Dong Bell |
| 32 | Fan Rode (2.5 feet)( |
| 33 | Fan clamp |
| 34 | Telephone Dabbi |