Military Engineer Services-MES has published Repairs To Tiling, Flooring, Joineries, Roof Sheet, Plumbing Works, Rolling Shutters And Steel Gates And Certain Misc B/R Works At Sect B And Otm Accn Of Zone Iii And Iv Area Under Ge Dinjan . Submission Date for this Tender is 12-09-2022. Shed Construction Tenders in dinjan Assam. Bidders can get complete Tender details and download the document.




Tender Notice

33643279
Corrigendum : Repairs To Tiling, Flooring, Joineries, Roof Sheet, Plumbing Works, Rolling Shutters And Steel Gates And Certain Misc B/R Works At Sect B And Otm Accn Of Zone Iii And Iv Area Under Ge Dinjan
Open Tender
Indian
Assam
dinjan
12-09-2022

Tender Details

Repairs To Tiling, Flooring, Joineries, Roof Sheet, Plumbing Works, Rolling Shutters And Steel Gates And Certain Misc B/R Works At Sect B And Otm Accn Of Zone Iii And Iv Area Under Ge Dinjan

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIRS TO TILING, FLOORING, JOINERIES, ROOF SHEET, PLUMBING WORKS, ROLLING SHUTTERS AND STEEL GATES AND CERTAIN MISC B/R WORKS AT SECT "B" AND OTM ACCN OF ZONE III AND IV AREA UNDER GE DINJAN.
Sl. No. Item Description
1Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
2Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
3Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
4Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and directed.
5Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
6Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing the rubbish off the premises complete all as specified and as directed.
7Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and as directed.
8Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.
9Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed.
10Dismantling timber boarding, any description, fixed in any position with nails complete all as specified and as directed.
11Dismantling of frame work, timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and as directed.
12Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
13Taking down chowkats or framewith shutters (without taking off shutter from the frame) not exceeding 1.5 Sqm in each complete all as specified and as directed.
14Taking down chowkats or frames with shutter (without taking off shutter from the frame)exceeding 1.5 Sqm but not exceeding 4 Sqm in eachcomplete all as specified and as directed.
15Taking down shutters of any description not exceeding 1 sqm each complete all as specified and as directed.
16Taking down shutters of any description exceeding 1 sqm but not exceeding 2 sqm each complete all as specified and as directed.
17Taking down shutters of any description and refixing in same location/opening not exceeding 1 sqm each including resecuring or easing & adjusting also refixing existing serviceable builders hardware complete all as specified and as directed.
18Taking down shutters of any description and refixing in same location/opening exceeding 1 sqm but not exceeding 2sqm each including resecuring or easing & adjusting also refixing existing serviceable builders hardware complete all as specified and as directed.
19Resecuring or easing & adjusting without taking off the shutter of size exceeding 1.00 sqm but not exceeding 2 sqm each complete all as specified and as directed.
20Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed.
21M&L for brick work with sub class "B" bricks (old size brick), straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
22M&L for brick work with sub class "B" bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
23M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and as directed.
24M&L for 75 mm thick,plain cement concrete(1:3:6) typeC-2 (using 40mm graded stone aggregate) as in sub base or floor finishes complete all as specified and as directed.
25M&L for 75 mm thick,plain cement concrete(1:3:6) typeC-2 (using 40mm graded stone aggregate) as in plinth protection, footpath, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
26M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
27M&L for glazed, ceramic, coloured tiles of size 450mm x 300mm x 7-8mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10 mm thick backing of cement mortar (1:4) complete all as specified and as directed.
28M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortar (1:6) & cutting, rounding to edge of slab, polishing complete all as specified and as directed.
29M&L for machine pressed precast concrete interlocking paver block, glossy finish of approved colour, design & shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 75 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
30M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste fixed with tinned tacks of wire staples complete all as specified and as directed.
31M&L for rendering 18 mm thick(10+8) externally one side of lathing in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement, mixed with integral water proofing compound @ 2% by weight of cement on top layer surface complete all as specified and directed. Note : WPC shall be measured and paid separately against respective item.
32M&L for rendering 12 mm thickon one side oflathing in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
33M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement with integral water proofing compound @ 2% by weight of cement complete all as specified and as directed. Note : WPC shall be measured and paid separately against respective item.
34M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
35M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry or concrete surfaces complete all as specified and as directed.
36M&L for rendering 10 mm thick in cement mortar (1:4) on other than fair faces of brick masonry or concrete surfaces complete all as specified and as directed.
37Supply only liquid water proofing compound(ISI marked) complete all as specified and as directed.
38M&L for reinforced cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified andas directed. Note : reinforcement shall be measured and paid separately against respective item.
39S&F for TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
40M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
41S&F for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 5cm but not exceeding 10cm wide Rough finished surface of concrete, flat complete all as specified and as directed.
42M&L for second class hard wood timber scantling, clean swan as in frame work, fixed with nails complete all as specified and as directed.
43S&F for 18/19 mm thick, veneered particle board, interior grade, solid core, medium density general purposes type with commercial face veneers type "BB" complete all as specified and as directed.
44S&F in repairs curtain rails, Harrison rail, aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and as directed.
45S&F for stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
46S&F in repairs stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
47Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel frames, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
48S&F for 3 mm thick sheet glass,ordinary quality and glazing with oil puttyin square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
49Supply only 5 mm thick sheet glass,ordinary quality and glazing with oil puttyin square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
50S&F for 0.63 mm thick, galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, with grade of zinc coating 275, conforming to IS -277-2003 complete all as specified and as directed.
51S&F for 0.80 mm thick, galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, with grade of zinc coating 275, conforming to IS -277-2003 complete all as specified and as directed.
52Fixing only 0.80 mm thick, galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, with grade of zinc coating 275, conforming to IS -277-2003 complete all as specified and as directed.
53S&F for 0.63 mm thick, galvanised, plain mild steel sheet as in ridge, hips, valley gutters and flushings, fixed with L-type or J-type or cranked hook bolts and washers, with grade of zinc coating 275, conforming to IS -277-2003complete all as specified and as directed..
54S&F for 0.80 mm thick, galvanised, plain mild steel sheet as in ridge, hips, valley gutters and flushings, fixed with L-type or J-type or cranked hook bolts and washers, with grade of zinc coating 275, conforming to IS -277-2003complete all as specified and as directed..
55S&F for 6mm thick asbestos cement, two piece adjustable plain angular ridge fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
56S&F for 6mm thick asbestos cement, corrugated sheet or semi-corrugated sheets fixed with L-type or J-type hook in roofs covering complete all as specified and as directed.
57S&F for 4 mm thick, AC plain building boards fixed to timber frame work with screws as in ceiling complete all as specified and as directed.
58S&F for 20 mm thick, second class hard wood boarding, clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etccomplete all as specified and directed.
59S&F for false ceiling with exposed metal (PPGI) framework/ "Tee" grid providing and fixing of suspended Tee grid false ceiling using "T" grid system - powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mmx600mm with main runner 32mm x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40 mm thick using 4mm thick non asbestos fiber cement board of size 595mm x 595mm, and asbestos free fiber cement board manufacturer using high pressure system curing technology. T grid framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more than 300mm from the adjacent wall. 1220mm/600mm cross tee to be interlocked between main runners @ 600mm c/c, so as to form 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 and type B category III of ISO 8336, tested as per AS 1530 Part-3 & B. S-476 Part 4, 5, 6, 7 & 8 should be placed in grid module to form after and including dismantling of existing false ceiling of any type complete all as specified and as directed.
60S&F for second class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
61S&F for 35 mm thick, second class hard wood, glazed and skeleton shutters with open rebated and prepared to receive glass, gauze, etc (without sash bars)edges of framing plain, chamfered or rounded, fitted with cut mitered beads for securing glass, etc, sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a) complete all as specified and as directed..
62S&F 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitered and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded as in SSR Part I Section 8 clause 8.24 (a) complete all as specified and as directed..
63S&Ffor 35 mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with lock rail and panels of 9mm BWR commercial Ply or 12mm thick veneered particle board medium density, with commercial face veneering on both faces. the size of rail and styles 150 & 100mm, complete all as specified and as directed.
64S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
65S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded, plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and as directed.
66S&F for factory made EPS core solid PVC Moulded door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, The door on all the edges to be sealed with lipping of 10mm (5mm x 2) thick x25mm wide PVC sheet for 3 sides and 60mm wide PVC sheet for lock side. The lipping shall be bonded to the 2mm moulded /plain PVC sheet with solvent cement complete all as specified and as directed.
67S&F for 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
68S&F for 75 mm size stainless steel, butt hinges, medium weight, cold rolled, complete all as specified and as directed.
69S&F for 150 mm long mild steel pressed handle, oval type, stove enameled blackcomplete all as specified and as directed.
70S&F in repair 150 mm long mild steel pressed handle, oval type, stove enameled blackcomplete all as specified and as directed.
71S&F for 150 mm size aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
72S&F for 100 mm size, extruded aluminium alloy handles, fabricated type, anodisedcomplete all as specified and as directed.
73S&F for 125mm size, extruded aluminium alloy handles, fabricated type, anodisedcomplete all as specified and as directed.
74S&F for 200mm long mild steel, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed.
75S&F in repair 200mm long mild steel, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed.
76S&F for 150mm long mild steel, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed.
77S&Ffor 150mm long aluminium, anodised, barrel tower boltsof extruded section complete all as specified and as directed.
78S&F for 100mm long aluminium, anodised, barrel tower boltsof extruded section complete all as specified and as directed.
79S&F for mild steel sliding door bolts, 250mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 boltsand nuts, four on bolt plate and two on staple plate etc complete all as specified and as directed.
80S&F for aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsor cast aluminium alloy, length of bolt of 300 mm anodised finish complete all as specified and as directed.
81M&L for mild steelframed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed.
82S&F for mild steel small articles usingflat iron of size 25x3mm thicksuch asband, strap, hold fast, cleat, support, hook, hinges, base tie for door frame etc and other similar items conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
83M&L for powder coated, anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etccomplete all as specified and as directed.
84M&L for anodised aluminium window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per meter including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium handles 2 numbers in each shutter, hinges, anodised aluminium snap beading, screws etc complete all as specified and as directed.
85S&F for anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleat glazing clips, rubber neoprene packing handle 2 Nos in each door, hinges, anodised aluminium snap beading screw etc. including powder coating of minimum 50 micron thickness complete all as specified and as directed.
86S&F for aluminium anodised (Deco) pattern grill 75X75mm mesh sizefor window, 7mm to 8mm thick, design No 102, including suitable F/H section frame, aluminium cleat, fixed with steel screw to window frame complete all as specified and as directed.
87S&F for aluminium (extruded section body) door closer hydraulically regulated, designation No.3, universal type suitable for shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
88S&F for 12mm thick prelaminated particle board, interior grade, one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame works complete all as specified and as directed.
89M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for embedding hold fast, bed block, cills, etcincluding necessary form work complete all as specified and as directed.
90Taking up or down 15 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for reuse at same site or other site complete all as specified and as directed.
91Taking up or down 20 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for reuse at same site or other site complete all as specified and as directed.
92Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 and fixturesfixed to walls and ceilings or laid in floors, etc complete all as specified and as directed.
93Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 and fixturesfixed to walls and ceilings or laid in floors, etc complete all as specified and as directed.
94Refixingof old serviceable steel tubing and connections in new or old position in walls, ceiling or floors, etc 15 mm bore with new fittings as required and cleaning of pipe complete all as specified and directed.
95Refixing of old serviceable steel tubing and connections in new or old position in walls, ceiling or floors, etc 20 mm bore with new fittings as required and cleaning of pipe complete all as specified and directed.
96Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth complete all as specified and directed.
97S&F in repairs plastic water closet, Seat and Cover for pedestal pan, white / black, closed pattern with flat bottomand mild steel chromium plated or aluminium hinging device complete all as specified and directed.
98S&F in repairs 10 liter capacity, PVC valve less syphonic duel type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
99S&F in repairs 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.
100S&F in repairs for PVC water tank top cover suitable for 250 to 1000 liter capacity tank complete all as specified and as directed.
101S&F in repairs vitreous china squatting pan, "Orissa"pattern, size 580 x 440 mm white with integral foot rest and "P" or "S" trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor using concrete 1:2:4 type B0 and to match with existing specifications complete all as specified and as directed. Make : Cat No. C0117 of Parryware/Hindware/Cera.
102S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain andflushing pipe, anti syphonic pipe with PVC seat and cover complete but excluding flushing cistern & flush pipe including making good to disturbed surfaces of floor using concrete 1:2:4 type B0 and to match with existing specifications complete all as specified and as directed. Make :Cat No. C0287/0288 of Parryware/Hindware/Cera.
103S&F in repairs vitreous china wash basin, size 550x400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make :Cat No. C0406 of Parryware/Hindware/Cera.
104S&F in repairs stainless steel kitchen sinks with drainage board made of1 mm thick sheet for kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mmx330mmx160mm complete all as specifiedand directed.
105S&Ffor stainless steel plate rack 1 mm thick racks of standard quality 900x900x250mm sizecomplete all as specifiedand directed.
106S&F in repairs 32/40 mm dia x 800mm long waste pipe for sink/wash basin/ urinal etc complete all as specifiedand directed.
107S&F in repairs 15 mm bore, stop valves,fancy type, cast copper alloy,chromium plated, with long shank and cup ( concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
108S&F in repairs 15 mm bore, angular stop cock/valves, fancy type, cast copper alloy,chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
109S&F in repairs brass chromium plated shower rose 125mm size, with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed.
110S&F in repairs 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
111S&F in repairs 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered "Hot or Cold" with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
112S&F in repairs 50mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.complete all as specified and as directed.
113S&Fin repairs 15 mm bore, bib taps, PTMT, any colour, high pressure screwed for iron pipes and fixed (minimum weight 15mm-90gms/20mm-125gms) complete all as specified and as directed.
114S&F in repairs casecade health faucet including hook and hose not less than 1.2 metre long all as specified and as directed. Make : Cat No. T9937A1 of Parryware/Hindware/Cera.
115S&F in 100mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed.
116S&F in repairs 600mmX450mm bevelled edge mirror of selected quality 5mm thick glass, mounted on PVC frame including key hole plates for hanging and fixed to wall with chromium plated cup washers and screws complete all as specified and as directed.
117S&F in repairs brass chromium plated, tubular towel rail, D-type, 60cm long between flanges with brackets complete all as specified and directed.complete all as specified and as directed.
118Disconnecting existing water tank of capacity not exceeding 500 litres,reconnecting and refixing in position including cleaning and removing all scale and dirt, etc from tank and from mouth of circulating pipes, washing the internal surfaces with bleaching powder etc and writing "cleaned on :-----(Date) with 2"height on outer face of tank with white paint complete all as specified and as directed.
119Dismantling of rotational moulded polyethylene water tank of capacity exceeding 250 litres but not exceeding 500 Ltrs complete all as specified and as directed.
120S&F for 500 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
121Dismantling of rotational moulded polyethylene water tank of capacity exceeding 500 litres but not exceeding 1000 Litres complete all as specified and as directed.
122S&F for 1000 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
123M&L for preparation of new untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
124M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
125M&L for preparation of old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
126M&L for preparation of new plastered surfaces and applying three coats of white wash on wallcomplete all as specified and as directed.
127M&L for preparation of new plastered surfaces of brick or previously untreated surface and applying two coats of oil bound distemper over one coat of alkali resistance primer complete all as specified and as directed.
128M&L for servicing of steel rolling shutters of size/area upto 21 sqm (single opening), lever operated with rectification of minor defects, overhauling, greasing, lubricating of guide rails and refixing clamps, riveting including necessary repairs to the locking arrangements and replacement of worn-out spare parts such as gear/worm/interlocking laths/ ball bearing in order to bring the rolling shutter easy operation and smooth functioning all as directed. Note : (i) The spare parts will be measured and paid separately as supply only under respective item of this schedule. (ii)Minor/small repair or minor welding if required to be done, the same shall be done at spot without removing the shutter and cost element of this work shall deemed to be included in the quoted rate under this item.
129Greasing only rolling shutters of size/area upto 21sqm (single opening) including guide channels complete all as specified and as directed.
130S&F in repairs 1 mm thick mild steel sheet hood cover of hexagonal, square or circular contour depending upon the contour of bracket plates, properly stiffened with MS angle/ flat stiffener at top and bottom edges complete all as directed.
131S&F in repairs 50mm bore MS pipe for suspension shafts for rolling shutters complete all as specified and as directed.
132S&F in repairs bevel gear box for rolling shutters complete all as specified and as directed.
133S&F in repairs crank handle for operating gear operated rolling shutters complete all as specified and as directed.
134M&L in repairs weldingexceeding 2.5cm but not exceeding 5cm in length to the thickness of metal not exceeding 6mm thick complete all as specified and as directed.
135Supply only gear/worm (machine cut) including connection mechanical device and testing complete all as specified and as directed.
136Supply only interlocking lath sections made out of cold rolled steel strips of 1.2mm thick and 75mm wide complete all as specified and as directed.
137Supply only rolling ball bearing of suitable size for existing rolling shutters complete all as specified and as directed.
138S&F for main spring "O" gauge 450mm long of approved make for existing rolling shutters complete all as specified and as directed.
139S&F for safety lever lock mild steel 4 levers suitable for existing rolling shutters complete all as specified and as directed.
140M&L for framed mild steel workfor door or gate of angle iron or other section with gusset plate, rail,braces, etc complete drilling for fixing of steel sheeting or other coverings. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, also fastening and fixing shall conforming to Fe-290 (Gde E-165) complete all as specified and as directed. Note : Steel sheeting or other covering, running rail/ guides shall be measured and paid separately.
141M&Lfor rolled mild steel as in roof trusses (framed),trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pieces, cleat etc shall conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
142S&F for 1.00mm thick plain mild steel black sheet in covering to door, water tank, water trough, hole punched, including round headed screws, clout nails and fixed to wooden or steel frame/members, etc with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends complete all as specified and as directed.
143M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight) complete all as specified and as directed.
144M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a)Taking down existing old tarfelt, bituminous compoundincluding plaster etc, cleaning & removing debris to a distance exceeding 100m & not exceeding 250m. (b)15 mm thick plastering in cement mortar (1:4) finished even & smooth. (c)Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming to IS-3384 (e) A layer of APP based polymeric membrane3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric(weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
145Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
146S&F for 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
147S&F for 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
148S&F for 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
149S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
150S&F for 110 mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and as directed.
151S&F in repairs 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.