| 1 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead :Clearing of floor for extension of controlroom building |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of materials within 50 metres lead :For thickness of tiles above 25mm and upto 40mm or pebbles to make the ground clear for construction/extension |
| 3 | Dismantling brick work manually/by mechanically means including stacking of servicable material and disposal of unservicable material within 50m lead as per direction of Engineer-in-charge :Backside brickwall in cement mortar |
| 4 | Demolishing R.B work manually/mechanically means including stacking of steel bars and disposal of unservicable material within 50m leadas per direction of Engineer-in-charge :Wall foundation |
| 5 | Earthwork in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, includidng dressing of sides and ramming of bottoms lift upto 1.5m including getting out excavated earth and disposal of surplus excavated earth as directed within a lead of 50m : in all kinds of soils |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and struts etc. upy floor five level excluding cost of centering, shuttering, finishing and reinforcement: (1:1.5:3) 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 8 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. (Thermo-Mechanically treated bars.) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundation,Plinth Beam, footing bases of column, slab and complete job :Foundation footings, bases of coulmns etc for mass concrete |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundation,Plinth Beam, footing bases of column, slab and complete:Lintels, beams, plinth beams girders and cantilevers(b)25mm dia |
| 11 | Providing and fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in position in cement mortar 1:3 , costof required centering centering, shuttering and curing complete 1:3:6 ( 1 cement : 3 coarse sand : 6 stone aggregate 20mm nominal size complete work |
| 12 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) Anodized aluminum (Anodized transparent or dyed to requiredshade according to IS:1868, minimum anodic coating of grade AC 15) |
| 13 | Providing and fixing double glazed hermetically sealed glazing inaluminum windows, ventilators and partition etc. with 6mm thick clearfloat glass both side having 12mm air gap including providing EPDMgasket, perforated aluminum spacers, desiccants, silicon sealant (bothprimary and secondary sealant) etc. as per specifications, drawings anddirections of Engineer-in-charge complete. |
| 14 | Cement Plaster in two coats : 20mm cement plaster on the rough side of single or half brick wall of mix:1:4 ( 1 cement : 4 fine sand |
| 15 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface smooth and even complete |
| 16 | 6mm thick cement plaster 1:3 ( 1 cement:3 fine sand )mixto ceiling |
| 17 | Cement Plaster in two coats : 20mm cement plaster on the rough side of single or half brick wall of mix:1:4 ( 1 cement : 4 fine sand Outer wall |
| 18 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work over and including primingn coat of water thinnable cement primer |
| 19 | Finishing walls with textured exterior paint of required shade on new work (two or more coats applied @ 3.28 l/10sqm) over and including base coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 20 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 21 | Cement concrete flooring 1:2:4 stone aggregate 20mm niminal size finishing with a floating coat of neat cement including slurry but excluding the cost of nosing of steps etc 50mm thick 20mm monimal size stone aggregate crushed |
| 22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS 15622 of approved make, in all collours and shade, laid on 20mm thick cement mortar 1:4 including grouting the joints with white cement and matching pigments etc completesize of tile 600x600mm |
| 23 | Steel structure work in built up sections, fixed with or without connectingplate, including cutting, hoisting, fixig in position and applying a priming coat of approved steel primer all complete |
| 24 | Providing and fixing of electric fittings to the extended portion to a building area of 35ft x 23ft |
| 25 | Carriage of materails By Mech.Transport, from source to site of work Sand, stone and aggregate To site for an avg lead of 10 km |
| 26 | Carriage of materails By Mech.Transport, from source to site of work cementTo site for an avg lead of 10 km |
| 27 | Carriage of materails By Mech.Transport, from source to site of work steel To site for an avg lead of 10 km |