Construction Of Himachal Niketan At Dwarka Sector 19 New Delhi Sh Providing Fire Alarm System There In Sh Providing Fire Alarm System There In, shimla-Himachal Pradesh

Public Works Department-PWD has published Construction Of Himachal Niketan At Dwarka Sector 19 New Delhi Sh Providing Fire Alarm System There In Sh Providing Fire Alarm System There In. Submission Date for this Tender is 24-08-2022. Alarm Systems Tenders in shimla Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33545927
Construction Of Himachal Niketan At Dwarka Sector 19 New Delhi Sh Providing Fire Alarm System There In Sh Providing Fire Alarm System There In
Open Tender
Indian
Himachal Pradesh
shimla
24-08-2022

Tender Details

Construction Of Himachal Niketan At Dwarka Sector 19 New Delhi Sh Providing Fire Alarm System There In Sh Providing Fire Alarm System There In

Key Value

Document Fees
INR 1500 /-
EMD
INR 51600.0 /-
Tender Value
INR 25.75 Lakhs /-

BOQ Items

Name of Work: Construction ofHimachal Niketan at Dwarka Sector-19 New Delhi (SH: Fire Alarm system therein)
Sl. No. Item Description
1Supply Installation and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable 2 Loop module and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Bosch Avenar 2000/Notifier (NFS3030) , Siemens (Fire Finder XLS Series)
2Supply, Installation, Testing and Commissioning of Active and networkable repeater panel/Mimick Panel with 600 character 7" LCD display/ mimic panel etc. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder)
3Supply, Installation, Testing and Commissioning of addressable multisensordetector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Bosch FAP-425-OT/Notifier FSC851+B224BI/ Siemens Fire finder HFP11+DB-11
4Supply, Installation, Testing and Commissioning of addessable Double ACTION manual call point & necessary fixing arrangements with key complete as required. MCP should have IP52 or better protection rating Shall be EN54 -Vds/UL-FM Certification. Make: Bosch FMC-210-DM-G-R/Notifier FSM500K/Siemens fire finder HMS/S
5Supply, Installation, Testing and Commissioning of Addressable Sounder with sound pressure 90 dB(A), Sounder should have IP40 or better protection rating. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder)
6Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input and 1 output which shall monitor normally open or normally closed contacts. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder).
7Supply, Installation, Testing and Commissioning of Addressable Control Relay Module. Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU"s, tripping of AHU"s, Fresh air fans, Ventilation fans, tripping of Access control doors etc.. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder)
8Supply, Installation, Testing and commissioning of IEC 60849 Approved Glow Type EXIT/Stair /Emergency Exit Sign Board as finalized by Engineer In Charge, on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener complete the work upto the entire satisfaction of Engineer In Charge. Make: PES /HEINRICH/ OMEX/ COOPER/Agni/Falcon
9Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
102 x 1.5 sq. mm
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1225 mm