Repair / Maintenance Of Street Light Fittings, Poles , Lt Cable, External Electric Power Transmission System, Fire Fighting Systems, Dg Set, Amf Panel And Allied Works At Afs K Hills Under Ge Af Thane , thane-Maharashtra

Military Engineer Services-MES has published Repair / Maintenance Of Street Light Fittings, Poles , Lt Cable, External Electric Power Transmission System, Fire Fighting Systems, Dg Set, Amf Panel And Allied Works At Afs K Hills Under Ge Af Thane . Submission Date for this Tender is 07-09-2022. Fire Fighting Consumable Tenders in thane Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

33515851
Corrigendum : Repair / Maintenance Of Street Light Fittings, Poles , Lt Cable, External Electric Power Transmission System, Fire Fighting Systems, Dg Set, Amf Panel And Allied Works At Afs K Hills Under Ge Af Thane
Open Tender
Indian
Maharashtra
thane
07-09-2022

Tender Details

Repair / Maintenance Of Street Light Fittings, Poles , Lt Cable, External Electric Power Transmission System, Fire Fighting Systems, Dg Set, Amf Panel And Allied Works At Afs K Hills Under Ge Af Thane

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Aug-2022 REVISED PAGES Other 05-09-2022
2 29-Aug-2022 REVISED BOQ BOQ 05-09-2022
3 06-Sep-2022 date corrigendum Date 07-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 66000.0 /-
Tender Value
INR 33 Lakhs /-

BOQ Items

Name of Work: REPAIR /MAINTENANCE OF STREET LIGHT FITTINGS, POLES ,LT CABLE,EXTERNAL ELECTRIC POWER TRANSMISSION SYSTEM, FIRE FIGHTING SYSTEMS, DG SET, AMF PANEL AND ALLIED WORKS ATAFS K HILLS UNDER GE AF THANE
Sl. No. Item Description
1Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
2Excavation in Trenches not exc. 1.50 Metre wide and not exc. 3 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
3Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. seggrating Serviceable Cables, Pipes, Bricks, etc. incuding Serviceable Pipes, Bricks, etc. and keep in Safe Custody for re-use including removing Unserviceable Cables to MES Store Yard and depositing/stacking properly, complete all as specified and as directed. NOTE : Necessary Earth Work will be measured and paid under appropriate Items.
4M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
5Supply and laying un reinforced precast concrete cable cover class LVtype-II, flat size 250mmx150mmx 40mm laid in trenches complete all as specified and directed by Engr-in-charge.
6Relaying ofreinforced precast concrete cable cover class LVtype-II, flat size 250mmx150mmx 40mm laid in trenches complete all as specified and directed by Engr-in-charge.
7Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
8Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
9Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications.
10Supply and providingElectrician with helper for repairtheunserviceable street light/ avaition light, including taking down High Mast Light and Taking up High Mast Light mechanically / Post Lamp fittings/Garden Light Gate Light and refixing the same in existing position including testing after repair complete all as directed.Note: (a) Necessary spare, fitting, excavationother related work will be measured in respective items of Sch A.(b) Necessary tools, ladder ,safty equiptment for electrician and helper will be arrange by the contractor in his own cost.
11Supply only Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 30 Watt, complete all as specified and as directed.
12Supply only Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 45/60 Watt, complete all as specified and as directed.
13Supply only Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 120 Watt, complete all as specified and as directed.
14Supply only Surge Protection Device of capacity 10 KV Single Phase 50 Hz, complete all as specified and as directed.
15S&F Multi LED Street Light Fitting of capacity 45 Watt IP 65, having Die-cast Aluminium Housing, Weather Proof with Accessories and connecting up with and including PVC insulated Copper Conductor Cable 1.5 Sqmm, Single Core including Taking down unserviceable Street Light Fittings from the Electric Pole, complete all as specified and as directed.
16S&F Multi LED Street Light Fitting of capacity 60 Watt IP 65, having Die-cast Aluminium Housing, Weather Proof with Accessories and connecting up with and including PVC insulated Copper Conductor Cable 1.5 Sqmm, Single Core including Taking down unserviceable Street Light Fittings from the Electric Pole, complete all as specified and as directed.
17M & L Integral Decorative LED 8 Watt Bollard Energy Saving, Environmental Friendly aesthetically designed with opal acrlylic withIP-65 Protection, providing electric connection with suitable PVC copper flexible conductor,providing PCC 1:3:6 (20mm graded aggregate) work of size 300x300x450mm including necessary formwork and earth work, complete all as specified and as directed. Make:Havells Cat Part No LHEVBDP7IN6K008 or equivalent in other makes as specified in Approved Make list in tender documents.
18Supply & fixing in replacement Integral LED aviation light 30 watt comprising of aluminium housing with polycarbonate enclosure with IP-65 protection complete all as specified and as directed by the Engr- in- Charge.
19Supply, fixing and testing LED Floodlight fitting of 120 Watt in repair/replacement of existing high mast lightsincluding LED lamps complete with body robust,corrosion resistant,superior finish and withoutany cracks or through holes,made in a single piece by high pressure die castaluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time shouldnot be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report .
20Supply only LED Bulb 15 for Integral pole mounted decorative LED post top including PVC dom spherical/GLOBE shaped, 240 V 50Hz complete all as specified and directed
21Supply, fixing and testing Post top lantern of 25/45 Watt in repair/replacement of existing lightsincluding LED lamps, acrylic, canopytotally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time shouldnot be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report including suitable size of GI pipe for post with PCC 1:3:6 complete all as specified and as directed by the Engr- in- Charge.
22All as per Srl Item No 21.00 above but Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp base 20 Watt.
23S&F Lithium based Energy Efficient integrated Solar Street Light 32 Watt in Single FRP Body encases Solar PV Panel 64/66 Wp Monocrystalline, Lithium Battery 11.1/12.8 Volt, 33 AH with in-built BMS, High brightness Watt - LED (160 to 180 Lumen/Watt) Lamp, CRI>70, Color Temperature 6500 K, Micro Controller based Charge Controller cum Friver, Automatic Dimming function with PIR Motion Sensor, Dusk and Down Operation, Working Temperature : (-)10 °C to (+)55 °C, Weight 18-20 Kg with adjustable Mild Steel Clamp suitable for Pole/Wall mounting with protection: Short circuit, Overload, Reverse Polarity and Battery Protections. Maunfacturer should produce Vital Parameters Test Report from NABL or Accredited Lab and should be made in india with CE & ROHS Tested and Certified and connecting up with Copper Conductor Cable of suitable size including Taking down unserviceable Street Light Fittings from Pole, complete all as specified and as directed.
24Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Srl Item No. 3.00 here-in-before) 1100 Volt grade, cross sectional area 10 Sqmm to 400 Sqmm 2/3½/4 Core after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
25Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 10 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
26All as per Srl Item No 25.00 above but for cable of size 16 Sqmm 4 core.
27All as per Srl Item No 25.00 above but for cable of size 25 Sqmm 3.5 core.
28All as per Srl Item No 25.00 above but for cable of size 35 Sqmm 3.5 core.
29All as per Srl Item No 25.00 above but for cable of size 50 Sqmm 3.5 core.
30All as per Srl Item No 25.00 above but for cable of size 70 Sqmm 3.5 core.
31All as per Srl Item No 25.00 above but for cable of size 95 Sqmm 3.5 core.
32All as per Srl Item No 25.00 above but for cable of size 240 Sqmm 3.5 core.
33All as per Srl Item No 25.00 above but for cable of size 400 Sqmm 3.5 core.
34Supply and fixing hot moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCBSP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing ,complete all as specified and as directed by Engr-in-charge.
35M&L for preparation of old painted surfaces of PCC pole and applying two coats of synthetic enamel paint inupto 1.50 metre height from top of PCC coping and applying two coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number with white synthetic enamel paint in 80mm high letters, over black synthetic enamel paint base of size 20cm x 20cm including applying two coats of white wash to coping of poles all as specified and directed by Engineer-in-Charge. Note :-(i) Colour of piant shall be decided by Engineer-in-Charge . (ii)Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
36M&L for for applying two coat of Silver paint on GI poles of street lights of ant description up to including 9 m overall length including preperation of old painted surface of G I Poles all as specified and directed. Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
37M&L Cement Concrete 1:2:4 type B2 ( using 20mm graded stone aggregate) as in Coping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling PCC Copping and/or removing damaged PCC Copping, complete all as specified and as directed.
38M&L GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 METRE long bent to shape as per specified for fixing Street Light Fitting including applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket, complete all as specified and as directed.
39Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications.
40S&F PVC insulated Multi Stranded FRLS-H Copper Conductor Cable 1.5 Sqmm, Single Core for connection of Street Light Fitting including Taking down unserviceable Cable of any description, complete all as specified and as directed.
41S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting including Taking down unserviceable Cable of any description, complete all as specified and as directed.
42M&L for Making Hole under Road/ Hardstanding including cutting, etc. with manual auger or bookie not exc. 100mm dia, complete all as specified and as directed.
43S&F in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31(9 metres long )complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in white and blue colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
44S&F in replacement of pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coat of Silver paint over a coat of primer in alternate strip of 30cm each in white and blue colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
45S&F in replacement of heavy duty GI pole for Solar street light, 6 meter long, erecting truly in vertical position including painting of poles with two coat of Silver paint over a coat complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
46Taking down the unserviceable and Supply and fix in replacement street light timer infared digital type with 24 Hours operation settings including suitable size of contactor completeall as specified and directed by Engineer-in-charge
47M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles,struts & mass concrete including necessary form work and fair finishing to exposed surfaces completeall as specified and directed by Engineer-in-charge.
48M&L Galvanised Steel Tubing Pipe 50 mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
49M&L Galvanised Steel Tubing Pipe 40mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
50M&L Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
51Supply and Fixingaluminum lugs suitable for Cable of size6 Sqmm to 16 Sqmm.
52Supply and Fixingaluminum lugs suitablefor Cable of size25 Sqmm.
53Supply and Fixingaluminum lugs suitablefor Cable of size 35 Sqmm.
54Supply and Fixingaluminum lugs suitablefor Cable of size 50 Sqmm.
55Supply and Fixingaluminum lugs suitablefor Cable of size 70 Sqmm.
56Supply and Fixingaluminum lugs suitablefor Cable of size 95 Sqmm.
57Supply and Fixingaluminum lugs suitablefor Cable of size 120 Sqmm.
58Supply and Fixingaluminum lugs suitablefor Cable of size 240 to 400 Sqmm.
59Supply and FixingMCCB 4 pole 63 A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.
60Supply and FixingMCCB 4 pole 100 A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.
61Supply and FixingMCCB 4 pole 160 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.
62Supply and FixingMCCB 4 pole 250 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.
63Supply and FixingMCCB 4 pole 400 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.
64Supply and FixingACB three pole, 630 A, 415 V, 50 Hz having breaking capacity 50 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.
65M&L for cable jointing kit for 1100 volt (1.1 KV) grade cable for end termination suitable for underground PVC/XLPE armoured aluminium conductor heavy duty cable ofsizes 10 to 35 Sqmm 2/3.5/4 core complete including testing/commissioning all as directed.
66All as per item No 65.00 above but of size 3.5 core 50 Sqmm.
67All as per item No 65 but of size 3.5 core 70 Sqmm.
68All as per item No 65 but of size 3.5 core 95 Sqmm.
69All as per item No 65 but of size 3.5 core 240 Sqmm.
70All as per item No 65 but of size 3.5 core 400 Sqmm.
71Supply, install, testing and commissioning Detectors Complying with and type certified to EN-45 Addressable type smoke detector Photoelectric/Optical with base with self built intelligence as per IS:11360 complete all as specified and as directed.
72Supply, install, testing and commissioning Detectors Complying with and type certified to EN-45 Addressable type Heat detector Photoelectric/Optical with base with self built intelligence as per IS:11360 complete all as specified and as directed.
73Supply, install Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and as directed.
74Supply, install C P hose pipe of 63mm dia and 15 m length, complete all as specified and as directed.
75Supply, install Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and as directed.
76Supply, install, testing and commissioning Addressable manual call point resettable type complete all as specified and as directed.
77Supply, install MS fire Hydrant valve 63 mm dia ,single headed complete all as specified and as directed.
78Disconnecting Monoblockpump set 3 HP capacity from suction/delivery line. lifting and removing from its existing foundation(inside/outside building) , dismantling carefully the pump and motor completely checking and segregating serviceable and unserviceable parts, cleaning/washingand servicing the serviceableparts by approved method, replacing unsv parts,(new parts required to be measured and paidseperately in respective schedule item)reassembling the pump completely. Dismantling , cutting and removing the burnt windings from motor, rewinding with existing size/gauge with super enameled/copper conductor and other approved insulating materials, heating, drying including varnishing, overhauling .Reassembling the pump andmotor,including paintingthe pump and MS channel with two coats of synthetic enamel paint incl marking of SM, MES or Ser No. installing monoblock pump to its existing foundation, commissioning, connecting up and testing complete all as directed.
79Disconnecting Monoblockpump set 10 HP capacity from suction/delivery line. lifting and removing from its existing foundation(inside/outside building) , dismantling carefully the pump and motor completely checking and segregating serviceable and unserviceable parts, cleaning/washingand servicing the serviceableparts by approved method, replacing unsv parts,(new parts required to be measured and paidseperately in respective schedule of item)reassembling the pump completely. Dismantling , cutting and removing the burnt windings from motor, rewinding with existing size/gauge with super enameled/copper conductor and other approved insulating materials, heating, drying including varnishing, overhauling .Reassembling the pump andmotor,including paintingthe pump and MS channel with two coats of synthetic enamel paint incl marking of SM, MES or Ser No. installing monoblock pump to its existing foundation, commissioning, connecting up and testing complete all as directed.
80Supply only Ball bearing suitable size for 3HP/10 HP pumpset
81Supply & Fixing ,in replacement Motor terminal box of existing sizes
82S&F in replacementDOL starter suitable for 3HP, 3 Phase, 415 Volts motor including testing and commissioning all as directed.
83Supply, install, testing and commissioning and fire alarm control panel complying with BS EN 54 double loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules, complete all as specified and as directed.
84Taking down unserviceable MS ERW pipe of any size complete as all specified and as directed.
85Supply & laying MS ERW Tubing 100 mm bore (dia) with all Fittings for Firefighting Water Line, laid in Trenches or laid in Concealed in Walls or any other situation, complete as all specified and as directed.
86Supply & laying MS ERW Tubing 80 mm bore (dia) with all Fittings for Firefighting Water Line, laid in Trenches or laid in Concealed in Walls or any other situation, complete as all specified and as directed.
87S&F in replacement of 1 TR portable type condenser and evaporator unit including compressor of air conditioner complete all as specified and as directed. Make- Bluestar Model PC12DB or equivalent
88Supply and laying in rigid non-metallic PVC conduit of size 20 mm(external dia) exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
89Material & labour for earthing complete with copper plate electrode (98 percent conductivity when annealed)of size 60 cm x60cm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including copper strip(98 percent conductivity when annealed) 20x3 mm upto 7.5 mtr long by means of means of copper/brass bolt, nut, check nuts and washers besides brazing at all joints with GI protection pipe of 40mm bore medium grade up to 7.5 metre and connected to earthing test point all as shown in electrical plate No.3 of SSR part-I and as specified or indicated and testing on completion including excavation & eartwork in any type of soil, PCC (1:3:6) type C-2 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4 Kg/Sqm), with frame, funnel with 20mm bore GI pipe medium grade watering pipe, wire mesh and lugs test pointetc complete all as specified and as directed.
90M&L for Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB"s.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of APFC panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage. (Notes :-This items includes the cost of cleaning & rewiringof panel. Spare parts required shall be measured and paid for separately under respective items as supply only)
91Supply only APFC microprocessor based relay 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge.
92Supply only Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge.
93Supply only Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge.
94Supply only capacitor duty contactor 3 phase suitable upto 10 KVAR capacity duty contactor 1NO 1NC 240 volts complete all as specified and as directed by Engineer-in-Charge.
95Supply only capacitor duty contactor 3 phase suitable upto 16 KVAR capacity duty contactor 1NO 1NC 240 volts complete all as specified and as directed by Engineer-in-Charge.
96Supply onlycurrent transformer of ratio 200/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
97Supply only current transformer of ratio 100/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
98Supply & fixing in replacement indictor lamp assembly LED type complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
99Supply & fixing Start/stop push button complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
100Supply & fixing in replacement of selector switch rotary type, flush button, 3 way position in one for voltmeter or Ammeter of any range as per existing complete all as specified and as directed by Engineer-in-Charge.
101Supply & fixing in replacement of digital type voltmeter 96 mm x96 mm, of range 0-500 Volts,Class-I complete all as specified and as directed by Engineer-in-Charge.
102Supply & fixing in replacement of digital type ammeter 96 mm x96 mm, of range 0-200 Amps,Single Phase complete all as specified and as directed by Engineer-in-Charge.
103M& L for preparation of existing painted surface of panel board/feeder pillar box (inddor/outdoor type), area not exeeding 10 Square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine inclusive of wiriting SM/MES No/ Name of feeder etc(not exceeding of height 5 cm each) including welding of broken panel, tightening electric connection of switch gear and cleaning of vegetation all around the panels upto one meter from all sides complete all as specified and as directed by Engineer-in-Charge.
104M&L for fixing MS sheet 2mm thick to existing LT panels / feeder pillar box including necessary straightening /correcting the distorted parts, cuttings, welding / riveting,drilling bend to shape as required, welding of hinges, sliding door bolts, locking arrangement, nut, bolts, washers etc and appying two coats of synthetic enamedled paint over a coat of red oxide primer to match with the existing surfaces comlepte including butt hinges sliding door bolts and taping , thimbling disconnecting all incoming and outgoing complete all as specified and as directed by Engineer-in-charge. Note :- Supply only butt hinges and sliding door bolts shall be measured and paid seperately.
105S&F in replacement 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
106S&F in replacement 250mm long mild steel sliding door boltsclip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts,four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in-Charge.
107AMC FOR DG set500 KVAMake Kirloskar through authorise service agencyofOEM. Location: Site AF Stn Kanheri Hills,Note:- spares required for above maint will be measured and paid separately under relevent items .Scope Of Work :Scope Of Work :-(a)  Engine Cooling System :- Checking of radiator conditions (check for radiator clogging, cooling fins condition, V belts, etc. Checking of K-Cool Super level, piping corrosions & any sign of radiator leaks. Checking of hoses & connections deterioration / wear & tear. C Checking of fan pulley mis-alignment / deterioration, defective bearings, corroded surface, grease condition. Checking the water pump leaks, noisy operation, abnormal vibration, impeller defects, cracked housing, worn out shaft, etc Checking of belts tension & deterioration. Checking thermostat for proper functioning. Checking water level sensor in radiator for K-Series Engines. b) Engine Fuel System :-Checking fuel lines connections (any signs of fuel leak, loose connections, corroded piping, fuel restrictions, defective clamps, deteriorated hose, etc.). Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.).Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.) Checking actuator of electronic governing system.Checking priming pump condition.Checking fuel filter condition – replace the filters as found necessary.Checking water separator condition.Checking fuel tank condition (any sign of water contamination, no water drain, corrosions / deteriorations, etc.Checking exhaust smoke condition to identify health of the engine.
108Srl Item No 100.00 contd/- (c) Engine Lubricating System Inspection :- Checking oil lines connections (any signs of oil leak, loose connections, corroded piping, defective clamps, deteriorated hose, etc. Checking oil pressure condition (any sign of erratic operation, defective gauges, defective pressure sensors, defective wiring harness, etc. Checking oil level & oil quality condition.Checking last oil change & oil filter replacement. Checking make up oil availability at site. (d) Engine Air Induction System :-Checking air filter indicator reading (any sign of defective sensor, erratic operation).Checking air filter (any sign of filter clogging, dirt accumulation, air obstruction, defective seal, damage/ deteriorated housing etc.Checking turbocharger condition (any sign of excessive end play, oil/ gas leak, abnormal operating noise, excessive vibration, overheating etc.)Checking hoses & connections deterioration / wear & tear.Checking Charge Air cooler condition- if any (sign of clogged core/ fins, air leaks at connections, damaged gaskets, etc. (e)Engine Exhaust System :- Checking the exhaust manifold condition (anysign of gas leak, missing bolts and nuts, red hot manifold, oil leak, deterioration etc.Checking the flexible bellow/ hoses & connections deterioration / wear & tear.Checking muffler condition (any sign of support insufficiency, corrosion, drain pipe valve not installed, not shielded, etc). Checking exhaust pipe insulation condition / deterioration.Checking smoke emission quality (any sign of excessive black smoke, bluish smoke, white smoke, restricted gas flow etc.
109Srl Item No 100.00 contd/-(f) Engine Electrical System :- Checking batteries condition (electrolyte level, distilled water level, defective plate, voltage drop during cranking-refer to manufacturer acceptable voltage drop, etc..),Battery capacity evaluation this can be done by battery discharge test.Replacement of batteries is to be planned. Checking the starting motor condition (any sign of defective solenoid, defective brushes, grounded / shortedconnection, struck up rotor etc. Checking the wiring harness condition (any sign of defects, grounded, loose connections, shorted, open circuit, any deterioration. (g) Generator Control Panel System Inspection :-Checking “start / stop / manual switch condition & functionality. Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality.Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality. Checking “Contactors, ACB for proper functioning /operations. Checking “wiring termination for proper tightness. Checking indicating lamps for proper functioning. Checking if fault/tripping circuits are working satisfactory. Checking if doors are closing properly. Checking if there is no blockage of air from rear ducts. Checking if the front opening is directing the hot air outside room.(h) AMF Panel :Checking the all connection of contractor, MCCB, cable connection and rectify the defect if found any. NOTE:- any spare parts required for maintenance will be measured and paid separatelyunder relevent items of Sch A as a supply only.
110Supply onlyspare parts of DG Set as mentioned below for model and Make of Kirloskar of capacity 500 KVAfor replacing of unserviceable parts for satisfactory functioning of engine, complete all as directed by Engr-in-Charge.
111Engine oil multi grade 15W to 40W.
112Coolant for radiators all as specified and directed.
113Fuel filter
114Oil filter
115Air filter
116Fuel filer Prelimary along with water seperator
117Belt set
118Fuel Hose set
119Feed Pump assembly
120Coolant Hose set
121Return oil pipewith suitable size nozzle as per existing
122Lube oil pressure pipewith suitable size nozzle as per existing
123Fuel pipe with suitable size nozzle as per existing
124Nut M-8
125Stop solenoid switch 24 Volts
126Oil pressure gauge
127AVR
128Digital Meter
129Indicator lamp suitable for AMF panel for DG Set 500 KVA Make Kirloskar
130Supply and fixing,in replacement, self starter 24 volt DC for DG Set 500 KVA Make Kirloskar
131Material and labour forCalibration of FIP and fuel injector from the authorized dealer, including petty repairs and replacing the suction & delivery valves, rollers to make the FIP and injectors functional for thecapacities ofDG set500KVA ( calibration and repair to be carried outthrough authorizedMICO test bench andtest certificate to be submittedby the contractor) all as specified and directed.
132Supply & fixing Three pole power contractor ,Type -MNX ,Aux contacts 2NO=2NC suitable for AMFpanel for DG Set 500 KVA of Make Kirloskar
133Supply & fixing AC control contractor -MO -25 AC-25 45A at 415 volt , suitable for AMFpanel for DG Set 500 KVA of Make Kirloskar.
134Supply & fixingDC control contractor -MNO22(2NO+2NC) AC-15 4A at 415 volt, suitable for AMF panelDG Set 500 KVAof Make Kirloskar.
135Supply and fixing, in replacement, change over switch 630 amps ,415 volt AC, for DG Set 500 KVA complete all as directed.
136Supply and fixing, in replacement,Battery terminal made with brass for 24 volt battery for DG Set 500 KVA ,complete all as specified and as directed.
137Taking down silencer pipe of the DG set of any capacity and dismentling asbestous rope decarbonizing the silencer and Supply and fixing heat proof asbestors rope 12mm dia on engine exhaust pipe including dismantling of worn out Asbestors rope and minor welding/tightening in leakage exhaustconforming to ISI specification fire proof/flame proof all as specified and directed.
138Supply onlystarter push bottom for 500 kva DG set complete all as specified and as directed.
139Supply onlyBattery 12 V, 180 Ah, 24 Plate, complete all as specified and directed.
140Supply only self starter 24 volt DC,complete all as specified and directed.
141Material with labour for painting the acoustic enclosure, Diesel engine , alternator, AMF panel with two coat of synthatic enamel paint after necessary scrapping the old paint, denting the damage portion complete all as directed.
142S&F,in replacement, change over switch 400 amps, 415 volt AC, for DG Set 500 KVA complete all as directed.
143S&F Solar LED Street Light Fitting of capacity 50 Watt with Motion Sensor based, Peak Lux Sensor on 37@7M, Eco friendly, User friendly, no UV/Mercury, Pressure Die Cast Aluminium Body, Maintenance Free Lithiumion Batteries of suitable capacity dully intenally fitted, Solar Panel Mono Crystalline Photo Voltaic Module of capacity 75 Watt with all Accessories and connecting up with Copper Conductor Cable of suitable size including Taking down unserviceable Street Light Fittings from Pole, complete all as specified and as directed.
144M&L Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty, drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked with necessary Conduit Accessories, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed.
145Disconnecting the electric connection ofAlternator of capacity 500 KVA DG set,taking out the accumulator and cleaning the core assemblythrough air blower, heat varnishing with insulating material and refixing the same in position complete all as directed..