}

Construction Of It Office Buildings Including Civil Construction, Hvac,Electrical Ht,Lt,Dg Sets,Ibms, Fire Protection, Plumbing, Structural Facade, Landscaping,Stp,Wtp,External Works At Meelavittan Ii Village, Thoothukudi Construction Of It Office Buildin, Chennai-Tamil Nadu

Tidel Park Limited has published Construction Of It Office Buildings Including Civil Construction, Hvac,Electrical Ht,Lt,Dg Sets,Ibms, Fire Protection, Plumbing, Structural Facade, Landscaping,Stp,Wtp,External Works At Meelavittan Ii Village, Thoothukudi Construction Of It Office Buildin. Submission Date for this Tender is 05-09-2022. Building Management System Tenders in Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

33443141
Construction Of It Office Buildings Including Civil Construction, Hvac,Electrical Ht,Lt,Dg Sets,Ibms, Fire Protection, Plumbing, Structural Facade, Landscaping,Stp,Wtp,External Works At Meelavittan Ii Village, Thoothukudi Construction Of It Office Buildin
Open Tender
Indian
Tamil Nadu
Chennai
05-09-2022

Tender Details

Construction Of It Office Buildings Including Civil Construction, Hvac,Electrical Ht,Lt,Dg Sets,Ibms, Fire Protection, Plumbing, Structural Facade, Landscaping,Stp,Wtp,External Works At Meelavittan Ii Village, Thoothukudi Construction Of It Office Buildings Including Civil Construction, Hvac,Electrical Ht,Lt,Dg Sets,Ibms, Fire Protection, Plumbing, Structural Facade, Landscaping,Stp,Wtp,External Works At Meelavittan Ii Village, Thoothukudi

Key Value

Document Fees
Refer document
EMD
INR 2642000.0 /-
Tender Value
INR 26.42 Crore /-

BOQ Items

Name of Work: PROPOSED CONSTRCUTION OF TIDEL PARK BUILDING AT TUTICORIN
Sl. No. Item Description
1EXCAVATION
2Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders.
3All Kind of Soil - (Upto 2.00m depth from NGL)
4All Kind of Soil - (Upto 2.00m to 3m depth)
5All Kind of Soil - (Upto 3.00m to 4m depth)
6All Kind of Soil - (Upto 4.00m to 5m depth)
7All Kind of Soil - (Upto 5.00m to 6m depth)
8All Kind of Soil - (Upto 6.00m to 7m depth)
9FILLING
10Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
11Supplying and filling conveyed gravel other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complyin
12Supplying and filling in the area wherever specified with good gravel earth filling in plint, area development, etc, wherever specified in layers of not exceeding 150mm thick, including breaking clods, storing, transportation, double handling watering, compacting each layer with vibrator compactor and at unaccessible places with wooden / steel rammers to achieve 95% proctor density at optimum moisture content, all leads and lifts bailing/pumping out of water to keep site dry while back filling, cost shall include conveyance of all materials , labours , machineries etc complete as directed,the rates to include loading , unloading , hire and fuel charges for tools and plants, and other incidental charges etc. as complete with all respect compiling with relevent standard specificatioons.as directed by engineer in charge ( Payment will be Based on Actual Initial and Final Level based quantity)
13Supplying and filling in foundation and basement with filling Quarry dust in layers of not more than 15 cm thick well rammed watered and consolidated complying with std spec.
14using 40 mm gauge hard broken granite stone jelly in Transformer area laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete
15PCC
16Cement Concrete 1:4:8 (One Slag Cement, Four Crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
17Below plinth level
18Cement Concrete 1:4:8 (One Cement, Four Crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
19Flooring
20FORM WORK
21Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete.
22Footing
23Grade Beam
24Plinth Beam
25Pedestal Concrete
26Column upto Plinth Level
27Shear Wall upto Plinth Level
28Lintel at all Levels
29Sill Concrete at all Levels
30Sunshade at all Levels
31Staircase at all Levels
32Column above Plinth Levels
33Shear Wall above Plinth Levels
34Roof Beam at all Levels
35Roof Slab at all Levels
36CONCRETE
37Providing of placing RMC Reinforced Cement concrete of the following grades using Slag Cement, machine crushed coarse agrregates 20 mm and 12.5 mm, M sand, Water and admixtureetc complete allfor casting concrete elements of all shape and size and at all heights. (M35Grade)
38M35 Grade Concrete
39Footing Concrete
40Grade Beam
41Plinth Beam
42Cover Slab
43RCC Wall
44Foundation below the plinth level
45Column
46Pedestal Concrete
47Foundation below the plinth level
48Providing of placing RMC Reinforced Cement concrete of the following grades using OPC 53 grade cement, machine crushed coarse agrregates 20 mm and 12.5 mm, M sand, Water and admixtureetc complete allfor casting concrete elements of all shape and size and at all heights. (M35 Grade)
49M - 35 Grade of concrete
50Floor Slab / cover slab
51RCC Wall
52Ground Floor
53First Floor
54Second Floor
55Third Floor
56Fourth Floor
57Headroom
58Lintel
59Ground Floor
60First Floor
61Second Floor
62Third Floor
63Fourth Floor
64Headroom
65Sill Concrete
66Ground Floor
67First Floor
68Second Floor
69Third Floor
70Fourth Floor
71Headroom
72Sunshade
73Ground Floor
74First Floor
75Second Floor
76Third Floor
77Fourth Floor
78Staircase Waist Slab
79Ground to First Floor
80First to Second Floor
81Second to Third Floor
82Third to Fourth Floor
83Fourth to Headroom
84Roof Beam
85Ground Floor
86First Floor
87Second Floor
88Third Floor
89Fourth Floor
90Headroom
91Roof Slab
92Ground Floor
93First Floor
94Second Floor
95Third Floor
96Fourth Floor
97Headroom
98M35 Grade Concrete
99Column
100Ground Floor
101First Floor
102Second Floor
103Third Floor
104Fourth Floor
105Terrace & Headroom
106STEEL REINFORCEMENT
107Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification
108MASONARY WORK
109Brick work in following Cement Mortar using best quality II class table moulded chamber burnt bricks of size 9" x 4-1/2" x 3" for foundation and basement including curing, etc., complete complying with standard specifiction. In Cement Mortar 1:5
110For Foundation and Basement.
111For Superstructure in Ground Floor
112For Superstructure in First Floor
113For Superstructure in Second Floor
114For Superstructure in Third Floor
115For Superstructure in Fourth Floor
116For Superstructure in Parapet & Headroom
117Brick partition walls of 11.50cm thickness using best quality II class table moulded chamber burnt bricks of size 9" x 4-1/2" x 3" in Cement Mortar 1:3 (One Cement and Three M.Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.
118For Foundation and Basement.
119Masonry work using Autoclaved Aerated cement blocks of size 600 x200 200 mm in cement mortar 1:6 (one oc cement six of sand) for super structure in all floors including fixing frames of door and windows, proper setting curing etc., complete complying with standard specification as directed by the departmental officers.
120For Foundation and Basement.
121For Superstructure in Ground Floor
122For Superstructure in First Floor
123For Superstructure in Second Floor
124For Superstructure in Third Floor
125For Superstructure in Fourth Floor
126Masonry work using Autoclaved Aerated cement blocks of size 600 x200 x100 mm in cement mortar 1:5 (one of cement Five of sand) for super structure in all floors including fixing frames of door and windows, proper setting curing etc., complete complying with standard specification as directed by the departmental officers.
127For Superstructure in Ground Floor
128For Superstructure in First Floor
129For Superstructure in Second Floor
130For Superstructure in Third Floor
131For Superstructure in Fourth Floor
132Supply and erection of Double Leaves Fire Rated Door with Frame having the dimension of 1800mm x 1400mm with following specification: a. Door Frame 1.6mm: Galvanized 120 GSM b. Door Leaf 1mm: Galvanized 120 GSM c. Shutter Thickness: 46mm d. Honeycomb: In-fill e. Glue Macroplast UR-7221 f. Door Hinges: 4" x 3" x 3mm, Double Ball:Ball bearing Butt Hinges Grade SS 304 - Finish SS g. Door Closer with Standard Arm Finish: Silver h. Lock Set: Dead Lock with both side key i. Door Orientation: To be confirmed by client j. Mounting of door: Brick wall mounted k. Powder Coating: Powder coated in standard RAL paint colour of PO Red (60 to 90) Microns l. Single Point Panic Bar (2 Horizontal): m. Dead Lock with both side key: n. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frame o. Rated Glass Schott Pyran with Frame p. Anchor Bolt with Endcaps The above assembly mounted on concrete or brick wall including the cost of cutting, chipping, concrete packing, pastering, scaffolding all other conveyence as per standard methods and as directed by the Departmental Officers.
133Staircase
134AHU and Electrical Room
135Shaft door
136Supply & Fixing of ALTERRA ALT 50 Frameless Glass Door (Single / Double Leaf) with toughened glass and door accessiories Frameless door Rebate Profile all around the door. Rebated Door Frame size 50x54mmdesign. Hardware - Dormakaba junior Office Hinges(3 nos) ,Studio Gala Locks (1no) in aluminium silver (EV1) finish and Dormakaba TS 89 Slide Channel Door closer with (as per EN 1154) and saddle plate for fixing on the Glass door. Glass Mounted Sweep seal or Door Bottom Seal. In case of Glass overpanel OHP100-SG Over Panel Door profile to be used.The hardware should be suitable for Glass thickness of 10/12mm.The Profile finish shall be as per Approved Architects specifications. Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 1.5 mm Gauge thickness Excluding 20 Micron of Anodizing. Max Door Height - 2700mm Max Door Weight - 80 Kgs
137Single Leaf Door - (900 x 2400mm)
138Double Leaf Door - (1400 x 2400mm)
139Providing and fixingAutomatic Sliding door operator, Make: DORMAKABA ES 200 (EASY) 6250, compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates,BGR 232, the UVV and the VDE regulations. TÜV design tested for Durability of 1,000,000 Cycles, Manufactured according ISO 9001, tested according to the low voltage guidelines, CE Compliant, fulfils DIN 18650 standards for Padestrian Safety, for framed glass door application with DORMA ST-Flex Profiles Systems,modular design including internal cover and with 12.52 mm Laminated glass for1 Nos sliding door panels and 1 Nos fixed panels, both sliding & fixed panels with DORMAKABA ST-Flex framed profile system with Interlocking Seals.Operator & Frame Finish should be Silver Anodised, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening sizes as given below. DORMAKABA ES200 Operators are of very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting.The track profile should be separate from the main profile for enabling reduction in vibration insulation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20 with SMPS for Power regulation. Activators- DORMAKABA Nemo Motion + Nemo Dual ( Safety & Motion ) Pack, EM Lock - Fail Safe with CableProgram Switch with Key. Max Panel Weight Carrying Capacity of 1 X 200 Kgs. The system shall have constant power supply230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below:
140Providing and fixing of 25 mm thick Flush shutter, with 6 mm ply finished with 1 mm thk laminate on both sides of the shutterand finishing with 3 horizontal grooves of 6 mm x 6 mm andbeech wood door frames of size 90mm x 50mm.using hinges, locks and door closure.Cost is inclusive of providing beech wood door frame duco painted / polished to desired color.
141UPVC Ventilator : Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
142Motorised Fire Rated Rolling Shutter - Model: RS 78GS . Curtain made of single skinned galvalume steel laths withNatural finish .Pressedgalvalume steel hood & motor cover with natural finsh .CE Certified CRS Compact Gear P.R.C Make Indirect Drive Operator.Three station push buttonwith deadman control.
143MS GRILL
144Supplying and fixing mild steel grills for windows, ventilators, etc., including priming coat etc., complete.
145SS HANDRAIL
146Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
147PLASTERING
148Plastering with Cement Mortar 1:5 (One cement and Five M.sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the Engineer-incharge.
149Ground Floor
150First Floor
151Second Floor
152Third Floor
153Fourth Floor
154Headroom
155Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the Engineer-in charge.
156Prepare surfaces and plaster with CM 1:5 (1 cement: 5 Msand) 17mm thick(12mm+5mm) to all exteriorfaces of walls including hackingas required on RCC surfaces continuous to masonry in super structure and 12mm will be rough plastering includes water proofing chemical compound and 5mm will be sand paper finishing & double layer chicken mesh .The ratesincluding curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
157PAINTING
158White washing three coats with best shell lime in all floors complete complying with standard specification and as directed , including gum, conjee,water, etc., complete.
159Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
160Painting two coats of newly plastered wall surface with Weather Proof Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
161Painting new wood/iron work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
162Providing and applying Texture Finish Paint (for External painting)and approved shade including preparation of surface for painting, applying primer and two or more coats of paint as per manufacturer’s specifications, scaffolding curing etc. complete as directed at all levels.
163FLOORING
164Supplying and fixing superfine polished Ruby red or equivalent colour Granite slab 20 mm thick for Lift facia with bullnose edges are set in CM 1:3 10mm thick for base and pointed with the same colour cement etc complete.The rate inclusive of labour charges for laying & pointing curing etc. complete
165Supplying and fixing pre polished Ruby red or equivalent colour Granite slab 20 mm thick for Pantry and wash basin counter with bullnose edges are set in CM 1:3 10mm thick for base and pointed with the same colour cement etc complete.The rate inclusive of labour charges for laying & pointing curing etc. complete
166Supplying and fixing pre polished Ruby red or equivalent colour Granite slab18mm to 20mm thick for stair case riser set in CM 1:3 20mm thick for base and pointed with the same colour cement etc complete.The rate inclusive of labour charges for laying
167Providing the floor with 20 mm thick Granite slabs of approved colour and sizein all floors over a base layer of 20 mm thick CM 1:3, the granite slab be laid over the cement mortor by applying white cement slurry in between base mortor and granite slab. The granite slabs are to beso laid that there should not beany gap inbetween the adjacent slabs and the joints shall be in line with another joint and uniform by using cutting machine without any damage to the sides of corners of the granite slab. The entire area of the flooring so laid shall be neatly pointed with coloured cement of 1.80 kg/m2. The granite slabs proposed for the work shall be shown to the departmental officers and got approved by them before use in the work etc., complete.
168Dadoing walls with following best approved quality, white / colour Glazed tiles of approved sizes set in Cement Mortar 1:2 (One Cement and Two M.sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
169Paving the floor with best quality Virtified Tiles of size 600 x 600 x 8mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M.sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
170Providing Granolithic floor finish 40mm thick with Plain Cement Concrete 1:2:4 using 3 to 10mm ISS HBG metal, river sand and including rubbingthe top surface smoothly thread lining if found necessary and curing etc. complete complying with standard specification and as directed by SIPCOT Officersincluding cost and conveyance of all material and labour, incidental charges, etc. complete.
171Supplying & laying of sun reflective index tiles 305 x 305 x 7 mm of 30 mm thick in cement mortar 1:3, 30 mm thick using white cement and hard crate mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
172WATERPROOFING
173TERRACE WATER PROOFING
174Surface Preparation: Providing and cleaning the surface to make it free from all the loose mortar, dust, and other contaminants and protrusions which may damage the membrane,etcdirected by engineer in charge
175Construction joints treatment - Providing and supplying E 135, SBR based admixture and polymer bonding agent, for filling CM 1:4 (fine M.sand) admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, including cut opening the joints in the form of "V" Surface Preparation: Providing and cleaning the surface to make it free from all the loose mortar, dust, and other contaminants and protrusions which may damage the membrane,etcdirected by engineer in charge
176Construction Joints/ Crack Treatment:- ( If Any) Providing and cut opening the construction joints and making groove in the form of "V" shape at required size at all construction joints, applying a slurry coat of E135(1 part E135 :1 part water :4 parts cement)SBR based, multipurpose, concentrated, liquid polymer additive, applying E135 modified mortar to fill the groove and cut open areausing CM 1:4 admixed with E135, at dosage of 1 Ltr per bag of 50 Kg cement, over the wet neat coat of E135, curing, etc and complete as per manufacturer"s specification.
177Coving / Corner Joint Treatment Providing and installing coving at all corners in required size of ( 75mm x 75mm) using polymer modified mortar sandwiched with Ardex Deck web , CM 1:4 admixed with E135, SBR based, multipurpose, concentrated, liquid polymer additive, at dosage of 1 Ltr per bag of 50 Kg cement, over the wet bindingslurry coat of E135 (1part E135 :1 part water :4 parts cement) curing, etc and complete as per manufacturer"s specification. [The additive shall confirms to:-pH: 9 – 10; Tensile adhesion over concrete(7 days) : 1.5Mpa; Hydrostatic pressure resistance: 50 psi(0.34Mpa); As additive to screed Flexural strength : 3.3Mpa]
178Cut out Treatment/ Horizontal Bore Packing Remove all loose particles, chipping open if necessary to make at least 15-20mm gap between pipe and the horizontalopening. Scratch and apply a epoxy Polymide coat of WPM 256 ,Sprinkle sand over the wet binding around the pipe, thoroughly pack the gap using cement mortar admixed withE135 at a dosage of 1 Lt r per bag of cement to the required consistency, in case of the gap between pipe and the horizontal opening is more than 25mm use 6mm down size jelly.Apply a neat coat of E135 Slurrycoat of E135 (1part E135 :1 part water :4 parts cement)in fresh application over the surface where the filling is done.
179Providing and applyingWPM 265 acrylic primer to all the surfaces where waterproofing membrane is to be installed etc complete as per the manufacturer"s technical specification and as directed by engineer in charge.
180Waterproofing Membrane: Providing and installing a premium type waterproofing using ARDEX WPM 002 a highly flexible acrylic co polymerbased synthetic micro fibre reinforced, heavy duty waterproofing membrane in two coats including,etc complete as per the manufacturer"s technical specification and as directed by engineer in charge. Membrane shall confirm to: [The membrane shall confirm to:-Form & Colour : liquids - Various colour; Specific Gravity : Approx. 1.06 kg/litre; Bulk Density : Approx. 1.4 kg/litre; Water absorption AS Al 21: App K 5%; Tensile Strength AS 1145 - 28 days dry: 1.97 MPa - after UV exposure : 2.32 MPa; Elongation at Break - AS 1145 - 28 days dry: 208% - after UV exposure : 155%; Movement joint testCSIRO : Pass; Overcoat time : 4 hrs @ 23°C 50% RH; Pot life: 3 hrs @ 23°C 50% RH]
181LIFT & OHT W.P
182Surface Preparation:- Providing and grinding all sharp edges to make it flush with the surface, cleaning all floor, walls areasto make it free from debris, dirt, dust and other contaminants, etc and complete as per manufacturer"s specification.
183Construction joints treatment - Providing and supplying E 135, SBR based admixture and polymer bonding agent, for filling CM 1:4 (fine sand) admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, including cut opening the joints in the form of "V" shape of required size, cleaning the grooves, applying neat coat of E 135, filling the groove with mixed mortar and finishing, curing, etc and complete as per manufacturer"s specification.
184Horizontal bore packing - Providing and supplying E 135, SBR based admixture and polymer bonding agent, for filling the gap between the wall and pipe using CM of required mix ratio admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, over the neat coat of E 135, including cleaning, filling - compacting in the horizontal bore holes, finishing the mortar flush with the surface, curing, etc and complete as per manufacturer"s specification.
185Waterproofing Membrane: Providing and applying one or more coats of WPM 200,2 component water based epoxy polyamide un-pigmented sealer binder, by mixing using mechanical means, applying mixed WPM 200 using brush / roller, including grinding sharp edges of the substrate, cleaning the substrate to make them free from all contaminants, etcand complete as per manufacturer"s specification.Providing and applying a coat of WPM 300,2 component water based epoxy polyamide membrane / moisture barrier, mixing two components by mechanical means, applying using brush / roller, including grinding all sharp edges of the surface, cleaning the substrate to make them free from all contaminants, treating the cracks and construction joints, etc and complete as per manufacturer"s specification.
186Screed for Floor - Providing and supplying of E 135, SBR based admixture and polymer bonding agent, for installing screed with required thickness using CM of required mix ratio admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, over the tacky bonding slurry of E 135, water and cement mixed in ratio of 1:1:3, including cleaning the surface, installing level buttons, applying the mixed mortar, compacting, leveling, curing, etc and complete as per manufacturer"s specification.
187Plastering - Providing and supplying of E 135, SBR based admixture and polymer bonding agent, for installing plastering using CM of required mix ratio admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, over the tacky bonding slurry of E 135, water and cement mixed in ratio of 1:1:3, including cleaning the surface, installing level buttons, applying the mixed mortar, compacting, leveling, curing, etc and complete as per manufacturer"s specification.
188TOILET
189Surface Preparation:- Providing and grinding all sharp edges to make it flush with the surface, cleaning all floor, walls areas up to skirting level or up to300mm high to make it free from debris, dirt, dust and other contaminants, etc and complete as per manufacturer"s specification.
190Providing and installing coving at all corners in required size of ( 75mm x 75mm) using polymer modified mortar, CM 1:4 admixed with E135, SBR based, multipurpose, concentrated, liquid polymer additive, at dosage of 1 Ltr per bag of 50 Kg cement, over the wet bindingslurry coat of E135 (1part E1355 :1 part water :4 parts cement) curing, etc and complete as per manufacturer"s specification. [The additive shall confirms to:-pH: 9 – 10; Tensile adhesion over concrete(7 days) : 1.5Mpa; Hydrostatic pressure resistance: 50 psi(0.34Mpa); As additive to screed Flexural strength : 3.3Mpa] BorePacking: The area around the pipe to be thoroughly cleaned and any loose materials should be removed as required, Scratch and apply a epoxy polyamide coat of WPM 256 ,Sprinkle sand over the wet binding around the pipe,Free flow Ardex B30 Non Shrink Grout around the PVC pipe is to be filledproperly and allowed to dry completely,
191Waterproofing Membrane: Providing and applying two coats ofArdex WPM 004, two components, two components, breathable, acrylic elastomeric waterproofing coating in two coats with dft0.8 - 1.0 mm thickusingbrush/rollerleaving each coat to dry completely, applying first coat of WPM 004, sandwiching WPM Deck Web at all corners and pipe penetration on the wet first coat of WPM 004,applying second coat of WPM 004 and allowing it to dry, etc and complete as per manufacturer"s specification. [The properties are:- Pot life : 60 min; Appearance : Grey colour fluid liquid; Mixed material density : 1-65 - 1.7 Gms / CC; Bond strength : 0.90 N/Sqmm; Depth of water penetration : >21mm, crack bridging upto 1 mm, flexible].
192Water Stops for Joints :Supply and applyof WPM SWa swellable waterbar based on polymer technology and designed for use in construction joints.
193Screed Concrete
194FALSE CEILING
195GYBOARD FALSE CEILING
196Providing and fixingin position M / Fsuspended false ceiling to detail as per drawing with GI frame work and 12.5mm tapered type gyp board panels to form grids of 457 x 1220mm as per manufacturers specification including provision for stepped shaped ceiling for light troughcomprising.
197Frame work of intermediate channels (M.F.T.) at 1220mm centres along one direction M/F ceiling section MF5 at 457mm centres along other direction.Perimeter channels (MF 6A)along walls alround perimeter side of the ceiling, all to detail as per drawing.
198The intermediate channels suspended from ceiling, through strap hangers 25 x 0.5mm (MF 8) at 1220mm centres connected to soffit cleats P534 (27 x 37 x 25 x 1.6mm) the cleats connected to ceiling through metal expansion rawl plugs 12mm dia and 17/16" long with necessary bolts and nuts etc. all connected with additional perimeter channels (MF 6A) for openings for light fixtures, AC ducts, vertical drops, offsets etc. wherever necessary all to detail and as per direction.
19912.5mm thick gyp board with tapered edges fixed to underside of suspended gridwith 25 mm screws to form grids of 457mm x 1220mm varied along wall ends etc. including Architectural boxing,design and painting the underside of gyp board with 2 coats of plastic emulsion paint of approved colour over a priming coat etc., complete.
200ARMSTRONG GRID FALSE CEILING
201Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Classic Max Beveled Tegular Edge Tiles with Armstrong Suprafine 15mm Exposed grid.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance =85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) with pin-hole visual in module size of 600x600x17mm, suitable for Green Building application, with Recycled content of 65%. The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 8.8 Kgs/M (as per standard installation layout mentioned below) & pull out strength of minimum 100 Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make.The Tile & Grid system used together should carry a 30 year warranty.
202INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall.Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum. Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.
203ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7mm thick, galvanized spring steel can also be used for installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main runner).Tentative Pricing for Supply and Installation of Classic Max Microlook Tile with 15mm Suprafine 32H Grid
204Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm andecondary cross "T" of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle ofsize 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mmcenter to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
205GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
206Providing and fixing Toilet cubicles made of 12mm solid compact laminate panels including doors & intermediate panels finished with textured melamine of ""nuvo series "" ofStylammakes conforming to ISO 2046 as per the detail drawings. This also includes providing and fixing in position necessary nylon& aluminium hardwareas per manufacturers specifications & project design consultants instructions like handles, hinges, latches, indicators, top rail, connectors, hooks, knobs, brackets, U channels, thumbturn, locks etc. Provision to made in the cubical for fixing Toilet paper holder, Health Faucet etc., as directed by the project design consultants and as per the detailed drawings.
207cubicle size 1000 to 1100mm widh x 1550 depth x 2003mm ( include bottom gap
208MISCELLANEOUS
209Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
210Providing and fixing in position Heavy duty precast SFRC. manhole cover and frame.Square shape 600mm internal dimensions
211Providing and fixing PVC coated MS rungs as per drawing and instruction of Engineer in-charge complete.
212Supplying and installation of STRIP SEAL EXPANSION JOINT system confirming to specifications for road and bridge works in the 40mm wide expansion gap provided in between decks over piers and in between deck and dirt wall over abutment with fatigue tested structural steel section at the nosing and anchorage assembly, including labour, equipment and incidental charges for fixing the joints complete in all respects, as per section 2600 of MORT & H specification (V Revision)
213Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse M.sand:6 graded stone aggregate 20 mm nominal size)well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
214Providing and laying of 80mm thick factory made cement concrete interlocking paver block of M-25 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 75mm thick compacted bed of coarse sand / M-Sand, filling with machine compaction, joints filling with fine sand / M- Sand etc., all complete as per the direction of Engineer-in-charge. PARKING
215Supply and Installation of Chain Link Fencingat all levels as per drawing of PVC coated chain link of 50mm x 50mm size mesh with a GI metal frame work (above tie beam height 300mm to 1500mm ) and GI pipe supports etc., inclusive of all welding, supporting, scaffolding and required insert plate, painting etc., to complete.
216ELEVATION
217STRUCTURAL GLAZING
218EDEL system: Providing and fixing of edel- v thermally broken designed with out Polyimide strip ,point fixed tensigrity bolted pre- engineered and pre fabricated one way glazed wall system , manufactured using structural grade aluminum alloy profiles as the minimum metal -all aluminum members size under tension will be as per final pre engineered size in one direction only from floor to floor as semi continous members, no lateral bracing or compression members with any other framing will be acceptable between the floor levels at any given point to cater to lateral movements , the four way hidden corner clamps at edges of the glass are made out of blocked strucutral aluminumm and the glass clamped system of fittings has be with stainless steel swivel locks which lock the glass panels ,the aluminum profiles are coated with desired coating of Powder coating / Anodizing as per international standards, All swivel clamp fitings to have PVC full solid block seperator to seperate glass panels and has to be of least 6 mm thickeness and equal to height of fittigs , zero water ingress or air ingress should is allowed in the entire system for the designed wind loads , the system is sealed with vaour ssured EPDM gaskets weather grade silcione and 3 to 4 legged silicone compatible gasket /Backer rods to face of metal , where ever glass to glasss joint occurs with metal or with out metal and also the silcione connection/joint .
219The metal and glass held by swivel clamps is seperated by dual vertical microwave cured EPDM gaskets of atleast 4 mm depth and 8 mm width and 40 perecent compression so that no day light passes through the Aluminum members and glass, the glass has to mandatorily be completed flushed to metal members-the sperator designed gaskets should act as thermal barrier and cushions for variable pressure between glass and metal and for pressure equilibrium basis , the framing system is bolted on to main building using HDG yst 310 steel brackets welded at per geomtery using total survey staion to acheive the geomotry of the building , the pre engineered system members and fittings are as per specifications that the clamp fittings have to mechanically fastened as through holding , nil hardware connections as single pieces and with out any friction stay, -all other hardwares line bolts are in ss 306 make - the thermal performance of the glass has to be the thermal performance of the entire system and no impact should take place on account metal system- the cost of glass will be paid seperately
220Vision Glass: Double glass unit : Supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened clear float glass 6mm thick, with reflective soft coating of blue shade on surface #2, an inner Fully tempered clear float glass 6mm thick, spacer tube 12mm wide, Dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required Performances mentioned below, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glassprocessor. (The glass thickness and design shall be verified according to building design loads) (i) Clear float glass 6mm thick substrate with reflective soft coating of Guardian® SunGuard® DS Blue 40 on face # 2, having properties as Visible Lighttransmittance (VLT) of 38 % , Light reflection internal 16% light reflection external 12% , Solar Heat Gain Coefficient 0.24 and U value of 1.66 W/m2 K .
221OPENABLE WINDOWS : Operable multipoint lock windows to fit and compatible with above system using pre engineered water tight alumninum framing system with normal alloy for doors and windows with pu powder/anodised coating , the average window size size is approximately 1.2 mtrs x 1.2 meters and glass glazed on with structral seal and clamped mechanically , the cost of glass will be paid seperately
222VERTICAL FIN: Providing and fixing of aluminium vertical fin using aluminium box section 100 x 45 with Powder coating of 60 microns . The system will be interleaved with necessary L angle, bracket , anchor fastener and other accessories etc
223Providing, fabricating and fixing in position M.S. Structure made out of M.S. rolled/hollow (rounds/rectangular/ square etc.) sections as per architect’s details including shearing /cutting, riveting, welding, grinding to smooth surface of all works, MS fixing holdfasts / anchor bolts to be grouted in concrete1:2:4 , providing and fixing nuts bots fasteners as required as per architect’s details, including painting with two or more coats of first quality synthetic enamel paint of approved quality and make over a coat of primer etc. complete as directed. ( MS standard section shall be measured and paid under relevant Item. Nuts, bolts, washersshall be deemed to have been included in the unit rates and nothing extra shall be paid for)
224Providing and fixing of Glass canopy work as per drawing, glass canopy will be designed with web designed M.S box section 150 x 150 as main fafter, SS spider fittings, canopy will be provided with glass covering of 6mm thick clear toughened glass 1.52 PVB laminated + 6mm clear toughened glass panels of the system will designed. connected to the main angle alignment rputer bolts, clear silicone sealanmt will be provided at the glass & glass contacts, sand blasting & expoxy painting etc., complete as per the instrution of site incharge
225Lawn: Supply and Planting of Bermuda grass by Dibbling method in the developed area for lawn
226Shrubs: Towards cost and supply of small shrubs, inclusive of pitting and planting .
227Small shrubs- 1,6" ht
228Tall shrubs - 1, - 2, ht
229Ground covers: Towards cost and supply of Ground covers, inclusive of pitting and planting
230Hedges: Towards cost and supply of Hedges, inclusive of pitting and planting
231Accent Trees: Towards cost and supply of Accent trees, inclusive of pitting and planting
232Plumeria alba
233Terminalya mantaly
234Accent palms: Towards cost and supply of Accent palms, inclusive of pitting and planting
235Foxtail palm
236Specimen Plants: Towards cost and supply of Specimen Plants, inclusive of pitting and planting
237Ficus benjamina: Towards cost and supply of Ficus benjamina-dome shape of 5 ft. ht., inclusive of pitting and planting
238Cycas: Towards cost and supply of Cycas of 1.5 inch dia., inclusive of pitting and planting
239Trees: Towards cost and supply of Trees, inclusive of pitting and planting
240Soil Work:
241Towards cost of soil mix (i.e Garden Soil and Manure)
242Irrigation work
243VRF SYSTEM
244VRF OUTDOOR UNITS:
245Supply, installation, testing & commissioning of modular type High COP VRF Air cooled condensing unit consisting of100% multi hermetically sealed scroll compressors (fixed speed/ variable speed) / multi hermetically sealed rotary compressors (inverter), condenser coil,variable speed condenser fan/s, initial charge of refrigerant (R-410A) and oil, internal refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, capacity control arrangements,etc. The ODU shall deliver the given capacity at 42°C ambient . All the items shall be enclosed in an attractive sheet metal cabinet & with steel base frames, complete as per specifications and drawings. The unit shall be mounted on double layer of vibration isolation pads.The unit shall be selected such that EER at AHRI conditions for 100% load shall be equal or greater than 12.5. The unit shall be suitable for 415±10% volts, 3 Phase, 50Hz, 4 wire electrical power supply.The unit shall be supplied with microprocessor control panel to operate with remote monitoring / control. The unit has to be compatible for any third party BMS.
24628HP
24730HP
24832HP
24934 HP
25038 HP
251Floor Mounted Air Handling Units
252Supply, installation, testing & commissioning of ductabletype Indoor units consisting 3 Row deep DX coil, drain pan, washable filter, blower with blower motor and drive arrangement,internal refrigerant piping, electronic expansion valve, electrical panel with controls duly wired, thermostatic control, cordlessremore controller,UV lamp provision etc. All the items shall be enclosed in an compact MS-Powdercoated /GI casing and be suitable for ceiling suspended installationas per specifications and drawings. The unit shall be suitable for 220±10% volts, 1 Phase, 50Hz power supply.The unit shall be supplied with VFD panel to operate with remote monitoring / control.
25312489 CFM / 31 TR 50mm SP
25410750 CFM / 27 TR 50mm SP
2559472 CFM / 24 TR 50mm SP
256Ceiling Mounted Duct type Indoor units.
2575604 CFM / 14 TR 30mm SP
2585413 CFM / 13.5 TR 30mm SP
2594983 CFM / 12.5 TR 30mm SP
2603258 CFM / 7 TR 30mm SP
2612000 CFM / 5 TR 30mm SP
262Supply ,installation, testing & commissioning of ofY- JOINTS (Multikits)
263Supply ,installation, testing & commissioning of ofFresh Air Fan
2642000 Cfm
265DOWNSTREAM ITEMS-VRF REFRIGERATION PIPE
266Supply, Installation and Testing of 18G hard drawn refrigerant piping, fittings with 19mm thick Class "O" tubular nitrile rubber insulation and finished . Complete piping workmanship to be carried out as per recommended practice. Scope includes all refrigerant pipes shall be properly supported using Rods,Anchor bolts, Threaded rods,etc.(all external piping shall run in covered cably tray and wrapped with Poly shield coating and painting for exposed piping only.)
26741.3 mm Dia Copper Pipe with 19mm thick insulation
26834.9 mm Dia Copper Pipe with 19mm thick insulation
26928.6mm Dia Copper Pipe with 19mm thick insulation
27022.2mm Dia Copper Pipe with 19mm thick insulation
27119.1mm Dia Copper Pipe with 19mm thick insulation
27215.9mm Dia Copper Pipe with 19mm thick insulation
27312.7 mm Dia Copper Pipe with 19mm thick insulation
2749.5mm Dia Copper Pipe with 19mm thick insulation
275Supply andCharging ofR-410 Additional refrigerant gas
276Supply and Installation of 2C x 1.0 Sqmm Communication cable in 20mm dia with PVC conduitfor indoor & VRF out door Unit.
277Supply Installation ofPVC drain pipe with 9mm thick Nitrile rubber tubular pipe insulation with necessary supports.
27825 mm
27932 mm
28040 mm
281GI Hot Dip / Powder Coated 16 SWG Cable Tray with 150mm width and 50mm height
282GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height
283GI Hot Dip / Powder Coated 16 SWG Cable Tray with 450mm width and 50mm height
284Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Oudoor Unit
285Ducting And Grill Works
286Supply, Fabrication and erection of fabricated ducting made up of GI sheets of 22 Gauge thickness
287Supply, Fabrication and erection of fabricated ducting made up of GI sheets of 24 Gauge thickness
288Supply, Fabrication and erection of fabricated ducting made up of GI sheets of 26 Gauge thickness
289Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
290Supply and installation ofSupply air Square Diffuser with collar damper . 600x600 mm
291Supply and installation ofReturn air Square Diffuser with collar damper . 600x600 mm
292Supply & fixing ofAcoustic insulation for supply air duct with 20mm Thick Class 1 rating Open Cell nitrile rubber insulation material with density of 140 to 180 kg /m³. Insulation shall have built-in Anti-Microbial protection and should pass Fungi Resistance as per EN ISO 846 Method A and Bacterial Resistance as per EN ISO 846 Method C. Insulation shall have noise absorption proprieties as per ISO 354, ISO 11654 & ASTM C 423. Thermal conductivity of  the insulation material shall not exceed 0.047 W/m K  at an average temperature of 20 Deg C as per EN 12667. Insulation should withstand maximum surface temperature of +85 Deg C and minimum surface temperature of -20 Deg C as per EN 14706 & EN 14304. The material should conform to Class 1 rating for surface spread of flame in accordance to BS 476 Part 7 & HB, V0 rating as per UL 94. Adhesive to adhere insulation to the walls & ceilings shall be from the Insulation manufacturer only
293Supply and fixing of Duct Mouth Dampers
294Valve Kit for AHU & CSU
295Vibration Isolater for Ceiling Suspended Unit
29611 Kw VFD Starter Panel for AHU
2977.5 Kw VFD Starter Panelfor AHU
298HT INSTALLATION AND ALLIED WORKS- EB SIDE
299Design,Manufacture,Transport,safe storage,Leading to the location of erection,Earthing,Testing and commisioning of the following items. "11 KV Two polestructure, "Supply and erection of two polestructure (3050 mm c/c) consisting of the following."R.S.J (200 x 100) size 9.145 meter long with 450 x 450 x 6mm base plate welded to the R.S.J. bottom - 2 Nos, "100 x 50 x 6mm M.S. channel and angles, clampsto support the A.B. switch, H.G. fuse, line disc, pin insulators, Lightning arresters,"M.S. clamps to fix the channels made out of 50 x 8mm M.S. flats and required angles as struts for cantilever projection to mount the A.B. switch, stay sets cable supports etc.,"11KV, 400A double break tandem operated A.B. switch with 11KV insulators operating pipe, operating handle with ON-OFF position indications and locking facility, guided, flexible earth for down rod pipe and other accessories. - 1 Set,"11KV HG. fuse with 11KV insulators -1 Set,"Pin insulators with long pin / A stool - 12 nos, "Station type11kvlightning arresters - 3 nos,"Stay set complete with guy insulators - 2 Set,"Note : Including All civil work like excavation concreting and back filling etc,
300DP STRUCTURE CONSUMER SIDE
301Design,Manufacture,Transport,safe storage,Leading to the location of erection,Earthing,Testing and commisioning of the following items. "11 KV Two polestructure, "Supply and erection of two polestructure (3050 mm c/c) consisting of the following."R.S.J (200 x 100) size 9.145 meter long with 450 x 450 x 6mm base plate welded to the R.S.J. bottom - 2 Nos, "100 x 50 x 6mm M.S. channel and angles, clampsto support the A.B. switch, H.G. fuse, line disc, pin insulators, Lightning arresters,"M.S. clamps to fix the channels made out of 50 x 8mm M.S. flats and required angles as struts for cantilever projection to mount the A.B. switch, stay sets cable supports etc.,"11KV, 400A double break tandem operated A.B. switch with 11KV insulators operating pipe, operating handle with ON-OFF position indications and locking facility, guided, flexible earth for down rod pipe and other accessories. - 1 Set,"11KV HG. fuse with 11KV insulators -1 Set,"Pin insulators with long pin / A stool - 12 nos, "Station type11kvlightning arresters - 3 nos,"Stay set complete with guy insulators - 2 Set,"Note : Including All civil work like excavation concreting and back filling etc,
302FENCING & GATE
303Fencing : Fencingwith 75 x 75mm 10SWG chain link mesh to a height of 1.8Mtrs. above ground level and a retaining wall with brick all around to a height of 330mm above ground with vertical members of 50 x 50 x 6mm M.S. angles at 1.5mtr. Intercal and tie angle at top with 25 x 25 x 6 M.S. angle.
304Gates : 1.8mtr. Height and 1.5mtr. Width gate made out of 50 x 50 x 6mm M.S. angle cross supports fixed on 100 x 50 x 6mm M.S. channels andcovered with 50 x 50 mm weld mesh with pad locking arrangements.
305Levellilng the Yard: Levelling the yard and spreading 40mm blue metal to a height of 75mm.
30611KV HT singleVCB PANEL (OUTDOOR)
307The HT singleVCB Switchgear panels will be of metal clad, free standing construction, suitable for operation on 11KV 3 Ph, 50 Hz, AC earthed system and fabricatedfromsheet steel, with powder coat finish painting of shade RAL 7032 . The panel shall contain components as mentioned below, complete with busbar inter connections control wiring designation labels, caution labels, sealing and pad locking facilities and wherever necessary space provision for entry of HT cables from the bottom through detachable gland plates."Scope of supply should include the following but not restricted and other items which are required for the satisfactory operation and performanceof the system can be considered as required."Supply of 11KV HTVCB Panel consists of "1 x 11KV 800A Incomer VCB Panel,"Circuit Breaker-1 no,"Current Transformer -3 no, "Voltage Transformer-3 no, "Numeric type Multi function relay for 50,51,50N , 51N,49,&95-1 no,"Master trip relay-1 no, "Multi function Digital Meter (TOD)-1 no,"Multi function Digital Meter (MFM), "CB ON / OFF Indication Lamp-2no, "Phase Indication Lamps-3no, "CB Spring Charge Indication Lamp-1 no, "Trip Circuit Healthy IndicatingLamp-1no, "12 way Alarm Annunciator with buil in Push buttons for Accept,Test and Reset,"Control Switch-1 no, "Space Heater with switch and Thermostat-1no,"Panel Illumination Lamp with door switch-1 no,Control Terminal Blocks,"Earth Bus bar,"Main Bus bar ,"Test terminal blocks for CTs with CT shorting Links-1no,"Removable Power cable gland plate-1no, "Removable Control cable gland plate-1no, "Earth Switch on HT Cable side-1no,"Electrical interlock in VCB Closing circuit by providing micro switch (1 NO+1 NC) at earthing switch .-1no, "Common Power Pack suitable for All Incoming and outgoing panels-1no,"Provision for receiving 230V A.C External Source-1 no,"Potential free contacts for BMS monitoring -1 no.
308PRODUCT: 11kV outDOOR ONE VCB INCOMER AND TWO VCB OUTGOING KISOKasperIEC62271-200typefloor standing, sheet steel clad cubicle-"VACUUM CIRCUIT BREAKER:"11kv 800 A WITH EARTHING PROVISION,"11kV, 800A, 31.5kA/3Sec. Draw-out VCB with Power Module,"Spring charging Motor: 230V AC,"Closing/Tripping Coil: 24V DC,"Aux. Contacts: 4NO+4NC."CURRENT TRANSFORMER:"11kV Indoor Resin Cast C.T,"INCOMER Ratio:450/300/250/200/5-5A, "OUTGOING 150/50/5A-5A-3SETS,"Core-1: 0.5/15VA,"Core-2: 5P20/15VA,"STR : 100 OCF."VOLTAGE TRANSFORMER:"11kV Indoor Resin Cast Fixed PT, "Ratio: 11kV/rt3/110V/rt3,"Core 1 : Cl.: 0.5, Burden: 100VA."PROTECTION DEVICES:"3 O/C + 1 E/F Relay 50/51/50N/51N - (IRI-PRO-V4),"High Speed Tripping Relay (CLR-H),"Auxiliary Relay (VAA33) - 3 Element,"Anti - Pumping Contactor ,"Digital Multi Function Meter With RS485 Port,"Digital Ammeter with Selector Switch,"Digital Voltmeter with Selector Switch,"ON / OFF / TRIP / TCH / Spring Charged Indication Lamps, "R,Y,B Phase Indication Lamps,"Power Pack ( 230V AC - 24V DC ),"Surge Arrestor (27kV,10kA) -TYPE II,"T-N-C Switch (Breaker Control Switch),"Local/Remote Switch,"8 Window Annunciator ,"16 Window Annunciator,"Buzzer,"Pushbutton for ACCEPT/RESET, "Control wiring with appropriate colours,"Control Fuses,"Space Heater / Thermostat,"Dis-Connecting Terminal Blocks - CT Circuits,"Terminal Blocks - Control Circuits,"Illumination Lamp,"Toggle Switch for Heater ON/OFF,"Door Limit Switch,"BUSBAR CONNECTIONS:-"Main Connections:Copper - 1RX80x10mm ,"Earth Connections:Copper - 50x06mm,"ENCLOSURE:"MS Sheet Steel enclosure suitable for outdoor (IP65) installation with the provision for receiving incoming & outgoing power cable through rear side bottom entry, excluding termination kits & glands. (Shade: RAL7032)."INCL Charges towards providing potential free contacts with necessary wiring for integration ofVCB panel with IBMS. The scope includes extending the wiring upto metering chamber for monitoring the breaker on/off status, Alarm/trip status for WTI,
309500KVA 11KV / 433V TRANSFORMER (OIL TYPE)OUTDOOR WITH OLTC
310Design,Manufacture,Transport,Erection, Testing and Commissioning of 11KV / 433V 3 phase 50 Hz, DYn11, 500 KVA OIL type Transformer with OLTC,of tapping +2.5% to -10% of steps 2.5% (5 Steps 6 position)level 1 losses and with terminal arrangement ofHT side cable box and LT sideWITHCABLE BOX erected in platform, flat channels to place the wheels and stoppers as required.
311HT CABLE & END TERMINATION
312Supply and Laying of 11KV 3 Core (E) 185 Sq.mm.XLPEcable.The cable shall be laid in the cable tray which is fixed inside the cable trench as required as per the site condition
313Supply and Terminating of 11KV heat shrinkable indoor type termination kit suitable for terminating 3core 185 Sq.mm. XLPE cable with necessary cable jointing accessories.
314Supply and Terminating of 11KV heat shrinkableOUTdoor type termination kit suitable for terminating 3core 185 Sq.mm. XLPE cable with necessary cable jointing accessories.
315CONTROL CABLES & TERMINATIONS
316Supply and laying of the following 1.1KV grade PVC copper control cables laid on cable trays / cable trench / wall / clamped inside the enclosure complete with necessary clamps and hardwares as required.
3173C x 2.5 Sqmmcablefrom Transformer-1,2 to Main MV Panel
31812C x 1.5 Sqmmcu.from Tr-1,2 fault to VCB
31912C x 1.5 Sqmmcu.from CP-1,2 to Engine set-1,2
3204Cx 2.5 sq. mm cable from Main MV Panel to DG CP-1,2
3213C x 4 Sqmmcable
322Supply and providing end termination for the following cables by using suitable single compresson gland and copper sockets as required. The cost of earthing glad with copper strips/wires shall also be included.
32312C 1.5sq.mm cu.cable
3244C x 2.5 Sqmm cu .cable
3253C x 2.5 Sqmmcable
3263C x 4 Sqmmcable
3272C x 4 Sqmmcable
328Excavation and backfilling of cable trench for HT Cable comprising of : - a) Excavation of cable trench of 1200mm D x 600mm W, b) Providing sand for 250 mm depth, c) Concrete truffs, d) Bricks and Back filling
329Cutting, Excavation of existing groundfor laying the above referred cable in 300 mm diaRCC Hume pipe protection of class "NP2". The excavated trench should be of 1000mm depth 600mm width. After laying it is vendor responsibility to make the original surface and hand over to the client.(For Road Crossing)
330"Supply and laying ofdouble walled corrugated (DWC) HDPE pipe of following sizes having corrugation on the outer wall and plain surface inner wall confirming to IS : 14930 Part - I and II complete with necessary HDPE fittings for protection .Work including Bends, Coupling of following size. Double wall corrugated HDPE pipe 250mm
331EARTHING
332Supply of UL Listed & CPRI Tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 ( OBO Type No. 17 3000 CCER)& is provided with universal clamp made ofSS to connect rod with flat conductor ( OBO Type No. 17 25 RTC) . Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided withHeavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system(OBO Type No.UFE) .for LT panels, cable trays,
333Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit.
33425 x 3mm copper flats for Transformer and Generator body,structure and LT Panel body earthing
33525 x 6mm copper flats for 500 KVA Transformer neutral earthing
3368 SWG bare Copper conductor for fencing earthing
33710 SWG copper wire
338Jumbering with O SWG copper
339cable route marker with cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required
340SAFETY EQUIPMENTS
341Supply and Installation of Danger Boards 11000 V (Stove enamelled) as per EB standards.
342Supply and Installation of Danger Boards 415 V (Stove enamelled) as per EB standards.
343Supply and fixing of GIfire buckets with round bottom, each set comprising 4Nos.fire buckets of 9Kg capacity including supply of M.S pedestal stand with hooks suitable for holding of 4Nos of fire buckets, painted with Post Office Red oil paint and letter FIRE on each bucket and filling with sand complete as required. .
34411kv highly insulated fibre glass FRP EARTH / DISCHARGE ROD KUSAM MECO MAKE Or eqvt-03x5feet-assembled height 15 feet-30mm diadie cast alu earthinginstrument to grip , 7/20 cu wire -7m,rubber hand grip 2 set,with canvas cover for carrying, Die cast alu. Grounding “C” Clamp as spare
345L.T. SWITCHGEAR
346The Switchboard shall be designed so as to receive cables suitable for bottom / top entry and bottom / top exit to suit site conditions. For complete technical details refer schematic drawing/layouts.. The panel shall be Double front/single front"Linear" or "L" or "U" shape to suit proposed electrical room. Panel shall be powder coated with approved shade."Rate shall include necessary sheet steel enclosure made out of 14 SWG sheet steel duly powder coated with the same paint shade of panel board adopter box to cover the cables and conduits above the panel to the acceptance of Consultant."Design, manufacturing, Supply at site, Unloading, Leading, Positioning, Erecting, Earthing, Testing and Commissioning of panels offree standing type, vermin proof, construction as per tender technical specification and the details mentioned separately,"Note: AllMCCBs in all panels shall have rotary handle mechanism and spreader wherever necessary.,"All ACBs with shutter release assembly, door interlock,"As per specification all outgoing MCCBs in the Main panel / distribution boards and incoming MCCBs of all Sub distribution panel boardsshall be of adjustable overload and short circuit protection settings."The outgoing MCCBs in the Sub Panels needs adjustable thermal overload settings only and fixed short circuit setting."i. 35KA - above 250A up to 630A ii. 25KA for above 63A & up to 250A. iii. 16KA - up to 63A."The KA rating of the MCCBs shall follow as per the BOQ. The KA rating for the Incomer of the Vertical MCCB DBs shall be of 16 KA rating only."Details of LT Panels : The details of components, ratings etc. of all panels are furnished in Power distribution schematic diagram,"Electrical Room Size : Vendor/Contractor to ensure that the panel/room layoutsare designed with adequate clearances as per IE rulesin theproposedElectrical rooms and can be accommodated in the designated space for el.rooms.
347MAIN SWITCH BOARD -1(MSB-) LOC: GF electrical room:A) Incomer - 1No. For Transformer 1.AND 2 with"800 AMPS MPACB, 50 KA (Ics) AC Motor operated with "Draw Out ( EDO )Type Four Pole Microprocessor based release with communication port RS485 "having Over current, 2no /nc cotacts,2a control fuse with base neutral link" short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications, on delay timer"Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping , ". as specified in the technical Specifications."There shall be one set of Metering Compartment incorporated with the following:-"1No - Class 1.0, 96Sq.mm.PM8240Digital Maximum DemandMeter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."1No - Multi control relay for control of Under voltage, Over voltage, Single phase preventer, Phase rotation, with control fuses wiring etc,"3Nos. -800/5A CL-1 10VA current transformer with CT short link terminal block for Multi function Meter, "1 No. - CDG11 Earth Fault relay LV MONITOR SPD160A FUSE WITH BASE,"3 No. 800/5A 5P10 10VA Current transformer with CT short link terminal block for Earth fault relay,27,59,87"1Set. - 3Nos.ofR,Y,Bphase indicating lamps with protection fuse for potential circuit.."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode."3 No. 800/5A CL-1 15VA Current transformer with CT short link terminal block for APFCR relay.ANNUNCIATION PANEL 8WAY,MC61 RELAY
348A) Incomer -1NO. FROM SOLAR MOTORISED MCCB 100A, 50 KA,4 POLE MICROPROCESSOR BASEDRELEASE FOR O/L, S/C & E/F PROTECTION AUX CONTACT ON DELAY TIMER "ACEESORIES FOR SOLAR "UNDER VOLTAGE, CLOSING COIL240V AC & SHUNT TRIP COIL-24V DC "METERING FOR SOLAR. I/C"KWH METER WTH SEALING ARRANGEMENT CTM "MFMMANAGER (A+V+HZ,KW,KVA,PF,KWH), CTR: =/5A, PORTFOR I/C "PROTECTION RELAYS :TNC SWITCH AM SWITCH,REVERESE POWER"EARTH FAULT RELAY,64R,MRA 4 RELAYDIFFERENTIAL RELAY UNDER VOLTAGE RELAY"CURRENT TRANSFORMER,100/5A, CL-1, 5VA FOR METERING ( 3 Nos. FOR ECAH PANEL)"CURRENT TRANSFORMER, 100/5A, CL-5P10, 7.5VA CL-5P10 FOR E/F RELAY REVERRSE POWER REALY LVM "EF RELAY,DIFFERENTIAL RELAY,AUTO SYN RELAY UNDER OVER VOLTAGE RELAY "FUNCTION SPD WITH 160A FUSEWITH PROTECTION ( U/V,O/V,U/F,O/F,RPR & O/C) INPUT VOLTAGE-3X240VAC, CT INPUT--5A."VOLTAGE SENSING RELAY, 3 PHASE, 3 WIRE, 415V AC, SETTING 75-95% U/V& 105-120% O/V, 2 C/O CONTACTS "SMPS BATTERY CHARGER I/P-1 PH 240 VAC & O/P 24V/10 AMPS "UNDER VOLTAGE, CLOSING COIL , SPRING CHARGING MOTOR- 240V AC & SHUNT TRIP COIL-24V DC"DIGITAL AMMETER CTR-/5A, AUX. SUPPLY 240V AC,"CURRENT TRANSFORMER, 1250/5A, CL-1, 5VA FOR METERING,"AUX. CONTACTOR , INDICATING LAMPS, PUSH BUTTONS, MCB & CONTROL FUSES,"Instruments Panel (for ALL Incomer)"INCOMERS shall be having EF RELAY BATTERY CHARGER, POWER PACK SCHNEIDER MAKE V AND A METERS
349Incomers shall be having with Necessary CTs, Digital Multi function meter MFM)(consist of A,V, Kw, kWH, kVA, TOD,PF, Hz (F)), PLP+DAR (power line protection + Din alarm relay),MPCB, RYB & ON, OFF, TRIP indication lamps, selector switches andMCBetc. for the Incomers as per schematic layout." with communication port RS485 "having Over current, with 100a 4P Neutral CONTACT2no /nc contacts " short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON "on OFF trip indications, annunciation panel for relay earth fault, differential protection,dg parameters like over current, reverse power,"ShutterAssembly,Racking interlock Manual /Electrical "closing& tripping ". as specified in the technical Specifications."There shall be one set of Metering Compartment incorporated with the following:-"1No - Class 1.0, 96Sq.mm.Digital Maximum DemandMeterwith Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."1No - Multi control relay for control of Under voltage, Over voltage, Single phase preventer, Phase rotation, with control fuses wiring etc."3Nos. 100/5A CL-1 10VA current transformer with CT short link terminal block for Multi function Meter 3Nos.100/5A CL-1 10VA current transformer with CT short link terminal block "1 No. - CAG14Earth Fault relay WITH CL PS CTs "3 No.800/5A 5P10 10VA Current transformer with CT short link terminal block for Earth fault relay "1Set. - 3Nos.ofR,Y,Bphase indicating lamps with protection fuse for potential circuit..SMPS,AMMETER DC VOLTMETER"1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.
350A) Incomer - 1 AND 2No. FROM DG :EACHwith "ACB, 800A, 50 KA,4 POLE ,EDO(ELECTRICALLY OPERATED DRAWOUT) WITH MICROPROCESSOR BASEDRELEASE FOR O/L, S/C & E/F PROTECTION AUX CONTACT ON DELAY TIMER "ACEESORIES FOR DG I/C ACBs "UNDER VOLTAGE, CLOSING COIL , SPRING CHARGING MOTOR- 240V AC & SHUNT TRIP COIL-24V DC "METERING FOR D.G. I/C "KWH METER WTH SEALING ARRANGEMENT CTM "MFMMANAGER (A+V+HZ,KW,KVA,PF,KWH), CTR: =/5A, PORTFOR DG I/C .-EMIFIXVI FPE "PROTECTION RELAYS :TNC SWITCH AM SWITCH "EARTH FAULT RELAY,64R,MRA 4 RELAYDIFFERENTIAL RELAY,AUTO SYN RELAY,UNDRER OVER VOLTAGE RELAY "CURRENT TRANSFORMER,800/5A, CL-1, 5VA FOR METERING ( 3 Nos. FOR ECAH PANEL)"CURRENT TRANSFORMER, 800/5A, CL-5P10, 7.5VA CL-5P10 FOR E/F RELAY REVERRSE POWER REALY LVM "EF RELAY,DIFFERENTIAL RELAY,AUTO SYN RELAY UNDER OVER VOLTAGE RELAY "FUNCTION SPD WITH 160A FUSE "AUTO STARTING ,& LDSS FACILITY WITH PROTECTION ( U/V,O/V,U/F,O/F,RPR & O/C) INPUT VOLTAGE-3X240VAC, CT INPUT--5A."VOLTAGE SENSING RELAY, 3 PHASE, 3 WIRE, 415V AC, SETTING 75-95% U/V& 105-120% O/V, 2 C/O CONTACTS "SMPS BATTERY CHARGER I/P-1 PH 240 VAC & O/P 24V/10 AMPS "Accessories FOR DG I/C ACBs :"UNDER VOLTAGE, CLOSING COIL , SPRING CHARGING MOTOR- 240V AC & SHUNT TRIP COIL-24V DC "DIGITAL AMMETER CTR-/5A, AUX. SUPPLY 240V AC "CURRENT TRANSFORMER, 1250/5A, CL-1, 5VA FOR METERING "AUX. CONTACTOR , INDICATING LAMPS, PUSH BUTTONS, MCB & CONTROL FUSES "Instruments Panel (for ALL Incomer)
351Incomers shall be having with Necessary CTs, Digital Multi function meter MFM)(consist of A,V, Kw, kWH, kVA, TOD,PF, Hz (F)), PLP+DAR (power line protection + Din alarm relay),MPCB, RYB & ON, OFF, TRIP indication lamps, selector switches andMCBetc. for the Incomers as per schematic layout." with communication port RS485 "having Over current, with 100a 4P Neutral CONTACT2no /nc contacts " short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON" OFF trip indications, annunciation panel for relay earth fault, differential protection,dg parameters like over current, reverse power,"ShutterAssembly,Racking interlock Manual /Electrical "closing& tripping ". as specified in the technical Specifications."There shall be one set of Metering Compartment incorporated with the following:-"1No - Class 1.0, 96Sq.mm.Digital Maximum DemandMeterwith Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."1No - Multi control relay for control of Under voltage, Over voltage, Single phase preventer, Phase rotation, with control fuses wiring etc."3Nos. -800/5A CL-1 10VA current transformer with CT short link terminal block for Multi function Meter "3Nos100/5A CL-1 10VA current transformer with CT short link terminal block "1 No. -Earth Fault relay WITH CL PS CTs "3 No.100/5A 5P10 10VA Current transformer with CT short link terminal block for Earth fault relay "1Set. - 3Nos.ofR,Y,Bphase indicating lamps with protection fuse for potential circuit..SMPS,AMMETER DC VOLTMETER "1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.B)
352Bus Coupler - 1No.800 AMPS , 50 KA (Ics) AC Motor operated "Draw Out ( EDO )Type Four PoleMP ACBO/L,S/C,E/F,U/V release :"6NO + 6 NC,indication for test,service,isolated ON 2no /nc contacts "/OFF trip indications, on delay timer "Shutter Assembly, Racking interlock Manual /Electrical "closing& tripping "closing& tripping ". as specified in the technical Specifications."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.PLC AM SWITCH TNC SWITCH "TNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.C) Outgoing -1,2 no-each with-forAPFC "1No. of 630 AMPS MCCB, 50 KA (Ics) "3 Pole Microprocessor based relay "having Over current," short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications, "Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping ". as specified in the technical Specifications."1No - Class 1.0, 96Sq.mm. PF Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."3Nos. 630/5A CL-1 15VA current transformer with CT short link terminal block for PF Meter."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF & Trip control.PF METER "outgoings2no each with "1No. of 800 AMPS TPN MCCB, 50 KA (Ics) "3 Pole Microprocessor based relay "having Over current," short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications,"Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping ". as specified in the technical Specifications.
3531No - Class 1.0, 96Sq.mm.MFM -2DI/2DO- Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."3Nos. -800/5A CL-1 15VA current transformer with CT short link terminal block for Multi function Meter."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF & Trip control "outgoings 3 no each with."1No. of 630 AMPS TPN MCCB, 50 KA (Ics) ,"3 Pole Microprocessor based relay "having Over current," short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications,"Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping ". as specified in the technical Specifications."1No - Class 1.0, 96Sq.mm.MFM -2DI/2DO- Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."3Nos. - 630/5A CL-1 15VA current transformer with CT short link terminal block for Multi function Meter."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF & Trip control."outgoing 3no each with "1No. of 400 AMPS TPN MCCB, 50 KA (Ics)"3 Pole Microprocessor based relay "having Over current," short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications,"Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping ". as specified in the technical Specifications."1No - Class 1.0, 96Sq.mm.MFM -2DI/2DO- Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc.
3543Nos. - 400/5A CL-1 15VA current transformer with CT short link terminal block for Multi function Meter."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse "TNC switch for breaker ON, OFF & Trip control."outgoings 4no each with "1No. of 250 AMPS TPN MCCB, 50 KA (Ics)"3 Pole Microprocessor based relay "having Over current, " short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications, "Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping ". as specified in the technical Specifications."1No - Class 1.0, 96Sq.mm.MFM -2DI/2DO- Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."3Nos. - 250/5A CL-1 15VA current transformer with CT short link terminal block for Multi function Meter."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF & Trip control."G) Bus bar "1600A TPN COPPER Bus bar with heat shrinkable colour insulated PVC sleeves."Note: To be provide 1No+1Nc potential free contact terminal block with wiring for all incoming and outgoing breakers for BMS."Electrical & Mechanical Interlock to be provide for all incomer and bus coupler.BATTERY CHARGER FOR DG "WITH SURGE ARRESTER IN EACHincomers WITH SUITABLE MPCB PROTECTION "PLC Automatic EB and DG changeover system to be provide as per the logic ref.main SLD.WITH 7.5 INCHTOUCH SCREEN MMI-Electrical interlocking with PLC.SELECTOR SWITCH- MANUAL/AUTO/PLC.CLEAN AGENT GAS BASED FIRE TRACE TUBE SYSTEM Automatic linear pneumatic Tube Detection based Clean Agent System for Electrical Panel
355CLEAN AGENT GAS BASED FIRE TRACE TUBE SYSTEM Automatic linear pneumatic Tube Detection based Clean Agent System for Electrical Panel "2 Kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, 2 Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation "2 Kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, 2 Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation "Health Monitoring Cum Alarm Panel "Automatic Fire extinguisher arrangement to be provide for all incomer and outgoing feeder compartment as per the CEA norms.internal, arc containment -standard -IAC (IEC61641)
356DG MAIN SWITCH BOARD- LOC: GF electrical room A) Incomer - 1,2No. For DG "630 AMPS 4P MPACB, 50 KA (Ics) AC Motor operated with "Draw Out ( EDO )Type Four Pole Microprocessor based release with communication port RS485 "having Over current, 2no /nc cotacts,2a control fuse with base neutral link " short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications, on delay timer"Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping , ". as specified in the technical Specifications "There shall be one set of Metering Compartment incorporated with the following:-."1No - Class 1.0, 96Sq.mm.PM8240Digital Maximum DemandMeter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."1No - Multi control relay for control of Under voltage, Over voltage, Single phase preventer, Phase rotation, with control fuses wiring etc "3Nos. -630/5A CL-1 10VA current transformer with CT short link terminal block for Multi function Meter "1 No. - CDG11 Earth Fault relay LV MONITOR SPD160A FUSE WITH BASE "3 No.630/5A 5P10 10VA Current transformer with CT short link terminal block for Earth fault relay"1Set. - 3Nos.ofR,Y,Bphase indicating lamps with protection fuse for potential circuit.."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.C) Outgoing -2 no-each with 800 AMPS 4PMCCB, 50 KA (Ics) AC Motor operated with communication port RS485 "having Over current, 2no /nc cotacts,2a control fuse with base neutral link " short circuit with time setting and
3576NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications, on delay timer"Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping ,". as specified in the technical Specifications."There shall be one set of Metering Compartment incorporated with the following:- "1No - Class 1.0, 96Sq.mm.PM8240Digital Maximum DemandMeter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."1No - Multi control relay for control of Under voltage, Over voltage, Single phase preventer, Phase rotation, with control fuses wiring etc,"3Nos. -630/5A CL-1 10VA current transformer with CT short link terminal block for Multi function Meter,"1 No. - CDG11 Earth Fault relay LV MONITOR SPD160A FUSE WITH BASE,"3 No.630/5A 5P10 10VA Current transformer with CT short link terminal block for Earth fault relay,"1Set. - 3Nos.ofR,Y,Bphase indicating lamps with protection fuse for potential circuit.."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.C) Outgoing -2 no-each with800 AMPS 4PMCCB, 50 KA (Ics) AC Motor operated withwith communication port RS485 "having Over current, 2no /nc cotacts,2a control fuse with base neutral link " short circuit with time setting and "6NO + 6 NC,indication for test,service,isolated ON"/OFF trip indications, on delay timer"Shutter Assembly,Racking interlock Manual /Electrical "closing& tripping , ". as specified in the technical Specifications.
358There shall be one set of Metering Compartment incorporated with the following:-"1No - Class 1.0, 96Sq.mm.PM8240Digital Maximum DemandMeter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc."1No - Multi control relay for control of Under voltage, Over voltage, Single phase preventer, Phase rotation, with control fuses wiring etc "3Nos. -800/5A CL-1 10VA current transformer with CT short link terminal block for Multi function Meter "1 No. - CDG11 Earth Fault relay LV MONITOR SPD160A FUSE WITH BASE"3 No. 800/5A 5P10 10VA Current transformer with CT short link terminal block for Earth fault relay "1Set. - 3Nos.ofR,Y,Bphase indicating lamps with protection fuse for potential circuit."1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse."TNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode."G) Bus bar :"880A TPN COPPER Bus bar with heat shrinkable colour insulated PVC sleeves."Note: To be provide 1No+1Nc potential free contact terminal block with wiring for all incoming and outgoing breakers for BMS."Electrical & Mechanical Interlock to be provide for all incomer and bus coupler.BATTERY CHARGER FOR DG "WITH SURGE ARRESTER IN EACHincomers WITH SUITABLE MPCB PROTECTION"Flexible Polymer Detection Tube with all necessary fittings &supports - Low Discharge Tubing . 6MM UL Listed"Health Monitoring Cum Alarm Panel "Automatic Fire extinguisher arrangement to be provide for all incomer and outgoing feeder compartment as per the CEA norms.internal, arc containment -standard -IAC (IEC61641)
359APFCR Panel - (175 Kvar): LOC:electrical room: "Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of Auto Power Factor Correction Relay (APFCR-175KVAr)suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, , dust & vermin proof, cubicle type, floor mounted, cable for incomer, gland plates at top/bottom for control cables, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. "1 No Intelligent Automatic Power Factor Controller Relay andVoltage & Power Factor Monitoring Relay can control up to 8 Capacitor Banks with LED indication for Alarm code, No. of Banks selected, PF status-Lead / Lag / Unity, Auto & Manual Mode, DIP Switches selection for No. of Banks / Time Relay and Bank ratios etc., with control wiring and all other required necessary accessories.pf meter, exhaust fans. INCOMER:1WITH "1- 630A 50KA TPNMCCB with accessories"1set -ON, OFF& TRIPLED type indication lamps "1set -T/N/C Switch andpf meter "1 Set –630/5A CT CL 1.0 15VA for metering "1 No. –Digital type Ammeter (0-630A) with selector switch "1 No. –Digital typeVoltmeter (0-500V) with selector switch "1 Set –LED type RYB indication lamp with control MCBs." Automatic Power Factor Control monitoringRelay."2 Sets of 50 KVAR Capacitor(2 x 25 KVAR) with suitable 200A TP MCCB with all other required necessary accessories, Cap.Duty Contactors,, control fuses, On,Off & Trip Indicating Lampsetc.,Including interconnection busbars, control wiringwith all other required necessary accessories.(One set spare) as per schematic,
3601 Set of 25 KVAR Capacitor(1 x 25 KVAR) with suitable 100A TP 36KA MCCB with all other required necessary accessories, Cap.Duty Contactors, control fuses, On,Off & Trip Indicating Lampsetc.,Including interconnection busbars, control wiringwith all other required necessary accessories. as per schematic "1 Set of 10 KVAR Capacitor(1 x 10 KVAR) with suitable 40A TP 36 KA MCCB with all other required necessary accessories, Cap.Duty Contactors, control fuses, On,Off & Trip Indicating Lamps etc.,Including interconnection busbars, control wiringwith all other required necessary accessories as per schematic.."3 Set of 5 KVAR Capacitor(1 x 5 KVAR) with suitable 40A TP 36 KA MCCB with all other required necessary accessories, Cap.Duty Contactors, control fuses, On,Off & Trip Indicating Lamps etc.,Including interconnection busbars, control wiringwith all other required necessary accessories as per schematic."1 Set of 25 KVAR FIXED Capacitor(1 x 25 KVAR) with suitable 100A TP 36 KA MCCB with all other required necessary accessories, control fuses, On,Off & Trip Indicating Lamps etc.,Including interconnection busbars, control wiringwith all other required necessary accessories as per schematic."(One set spare) as per schematic,Each capacitor bank in a separate compartment with necessary ventilation arrangements as required by the Electrical Authorities .COPPER BUSBARS
361DG ISOLATIONPanel -OUTDOOR WITH ENCLOSURE Incoming WITH CT PROVISION "630A TP&N MCCB Not less than 50 KA with necessary accessories CT, control wiring etc.- 1 No. as incomer.
362MLSB:"Design, supply, erection, testing and commissioning of cubicle type floor mounting panel board made out of MS sheet enclosure with Copper busbars, single busbar system, cable chamber, protection relays, interconnection, painting, earthing etc. comprising of the following."IncomingWITH "200A, TPN, 35kA, MCCB - 1No."The incomer shall have,"1 set –Digital Comibined meter having the parameters of Ammeter,Voltmeter and Energy meter "1 set –200/5A CT CL 1, 10VA "“ON/OFF & TRIP,"RYB" indicating lamp and also refer the schematic drawing "250Amps TPN cu. busbars: Current density consider 1.3 Amp/1Sq.mm."Earthing : 50 x 6mm GI flat "Outgoing "100A, TPN, 35kA, MCCB - 1Nos."63A, TPN, 35kA, MCCB - 6Nos "All outgoing feeders shall be having "ON,OFF&TRIP and "RYB" indication lamps.."Note:With necessaryCOPPER. busbars, interconnection providing multifunction meter ,phase indication lamp, fuse and switch control etc. in theincomer. All switch boards shall be fabricated as per the detailed specification enclosed."Cable Entry: Top "Cable Gland Plate: 3mm thick MS sheets."Note: Incomer/Outgoing MCCB shall have rotary handle mechanism and spreader wherever necessary.
363MPSB:"Design, supply, erection, testing and commissioning of cubicle type floor mounting panel board made out of MS sheet enclosure with Copper busbars, single busbar system, cable chamber, protection relays, interconnection, painting, earthing etc. comprising of the following."Incoming"200A, 4P, 35kA, MCCB - 1No."The incomer shall have,"1 set –Digital Comibined meter having the parameters of Ammeter,Voltmeter and Energy meter "1 set –200/5A CT CL 1, 10VA "“ON/OFF & TRIP,"RYB" indicating lamp and also refer the schematic drawing "250Amps TPN copper. busbars: Current density consider 1.3Amp/1Sq.mm."Earthing : 50 x 6mm GI flat "Outgoing "160A, TPN, 35kA, MCCB - 2Nos."100A, TPN, 35kA, MCCB - 1No."63A, TPN,35kA, MCCB - 6Nos."All outgoing feeders shall be having "ON,OFF&TRIP and "RYB" indication lamps."Note:With necessary cu. busbars, interconnection providing multifunction meter ,phase indication lamp, fuse and switch control etc. in theincomer. All switch boards shall be fabricated as per the detailed specification enclosed."Cable Entry: Top/BOTTOM "Cable Gland Plate: 3mm thick MS sheets "Note: Incomer/Outgoing MCCB shall have rotary handle mechanism and spreader wherever necessary.
364HVACPANEL OUTDOOR 1 AND 2 -supply, installation, Testing and Commissioning ofPANEL floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below. INCOMER:- 1 No –630A 4PMCCB TPN 36 KA OL ,SC RELEASES with FD KIT1 Set –630/5A CT CL 2, 15VA for metering,1 No. –Digital type Ammeter (0-630A) with selector switch,1 No. –Digital typeVoltmeter (0-500V) with selector switch,1 Set –LED type RYB indication lamp with control MCBs,1 Set –LED type ON/OFF indication lamp with control MCBs. OUTGOING:-14no63A TPN 36 KA MCCB,-,BUS BAR RATING: One set:400A TPN 36KA for 1 sec. CU. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.PH:1R50 x 10mm AL.Flat,N: 1R 25 x 10mm AL.Flat,E: 1R 25x3mm Cu.Flat,Cable gland plates- Al 3mmthick,CABLE ENTRY & EXIT : TOP/BOTTOM
365LIFTPANEL OUTDOOR -supply, installation, Testing and Commissioning ofPANEL floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below. INCOMER:- 1 No –160A 4PATS, 160A TPN MCCB 36 KA OL ,SC RELEASES with FD KIT1 Set –160/5A CT CL 2, 15VA for metering,1 No. –Digital type Ammeter (0-160A) with selector switch,1 No. –Digital typeVoltmeter (0-500V) with selector switch,1 Set –LED type RYB indication lamp with control MCBs,1 Set –LED type ON/OFF indication lamp with control MCBs. OUTGOING:3SETS EACH CONSISTS OF 1no63A TPN MCCB,1NO 20A DP RCCB-WITH 3 NOS6A SP MCB AND 6/16A SOCKET 1NOWITH SWITCH,BUS BAR RATING: One set:160A TPN 36KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.PH:1R20 x 10mm AL.Flat,N: 1R 25 x 10mm AL.Flat,E: 1R 25x3mm Cu.Flat,Cable gland plates- Al 3mmthick,CABLE ENTRY & EXIT : TOP/BOTTOM
366LIFT isolation panel-INCOMER:- 1 No - 63A TP+N 35KA MCCBLED type RYB indication lamp with control 25a dp MCBs,enclosure.RCBO 4p 63a,busbar and busbar chambers,fabricted box
367STP PANEL -supply, installation, Testing and Commissioning ofPANEL floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below. INCOMER:- 1 No –160A 4PMCCB TPN 36 KA OL ,SC RELEASES with FD KIT1 Set 160/5A CT CL 2, 15VA for metering,1 No. –Digital type Ammeter (0-160A) with selector switch,1 No. –Digital typeVoltmeter (0-500V) with selector switch,1 Set –LED type RYB indication lamp with control MCBs,1 Set –LED type ON/OFF indication lamp with control MCBs. OUTGOING:-8no32A TPN MCCB,-,BUS BAR RATING: One set:200A TPN 36KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.PH:1R25 x 10mm AL.Flat,N: 1R 25 x 10mm AL.Flat,E: 1R 25x3mm Cu.Flat,Cable gland plates- Al 3mmthick,CABLE ENTRY & EXIT : TOP/BOTTOM
368PUMP PANEL -supply, installation, Testing and Commissioning ofPANEL floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below. INCOMER:- 1 No –100A 4PMCCB TPN 36 KA OL ,SC RELEASES with FD KIT1 Set 100/5A CT CL 2, 15VA for metering,1 No. –Digital type Ammeter (0-100A) with selector switch,1 No. –Digital typeVoltmeter (0-500V) with selector switch,1 Set –LED type RYB indication lamp with control MCBs,1 Set –LED type ON/OFF indication lamp with control MCBs. OUTGOING:-4no32A TPN MPCBWITH DOL STARTER,1NO63A TPN MPCB WITH DOL STARTER,-,BUS BAR RATING: One set:2120A TPN 36KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.PH:1R25 x 10mm AL.Flat,N: 1R 25 x 10mm AL.Flat,E: 1R 25x3mm Cu.Flat,Cable gland plates- Al 3mmthick,CABLE ENTRY & EXIT : TOP/BOTTOM
369SSB- :(SSB- typical for GF AND 1 TO 4 FLOORS) Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed A) Incomer 1& 2 : 1Nos 160 Amps Fourpole Type Motorized MCCB with Autimatic Closing Mechanism of 35 kA Short Circuit Rating with adjustable Thermal O/L andfixed Magnetic S/C Protection and interlocking arrangements(Automatic changeover) , There shall be one set of Metering Compartment incorporated with the following:- 1No - Class 2.0,Digital Dual source MultifunctionMeter with Inbuilt Selector Switch,communication port RS 485 having MODBUS Protocol with control fusese etc., 3Nos. - 160/5A CL-0.2,15VA current transformer with CT short link terminal block for Multi function Meter 1Set. - 3Nos.ofR,Y,Bphase indicating lamps, On, Off, Trip Indication lamp with protection fuse for potential circuit. 1Set of ELR 100mA with CBCT to be provided for incomer feeder.B) Outgoing :3 Nos 125 Amps TP&N MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with adjustable Thermal O/L andfixed Magnetic S/C Protection with Suitable Class 0.2,Digital Dual source MultifunctionMeter with Inbuilt Selector Switch,suitable rating of CTs and communication port RS 485 having MODBUS Protocol with control fusese etc. 2 Nos 100 Amps TP&N MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with adjustable Thermal O/L andfixed Magnetic S/C Protection. with Suitable Class 0.2,Digital Dual source MultifunctionMeter with Inbuilt Selector Switch,suitable rating of CTs and communication port RS 485 having MODBUS Protocol with control fusese etc 1 Nos 32 Amps TP&N MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with adjustable Thermal O/L andfixed Magnetic S/C Protection. with Suitable Class 0.2,Digital Dual source MultifunctionMeter with Inbuilt Selector Switch,suitable rating of CTs and communication port RS 485 having MODBUS Protocol with control fusese etc C) Busbar : 192A TPN 35KA Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. Current density - 1.2Amps/Sqmm.
370FLOOR AHU PANEL-Design,Manufacture,supply, installation,Testing, Commissioning and earthing of thepanel-with necessary metal base frames, free standing dust and vermin proof byConstruction of 14 / 16 SWG CRCA sheets with bolted construction powder coated panel incoming and outgoing breaker details as per the technical specification, SLD & as mentioned below1 NO -40 A TPN MCB,O/G 40A TPN MCB 3 NOS- RYBIndication Lamp and Power& control terminal Terminal block
371FIRE FIGHTING PANEL1 Design,Manufacture,supply, installation, Testing, Commissioning and earthing of thepanel-with necessary metal base frames, free standing dust and vermin proof by construction of 14 / 16 SWG CRCA sheets with bolted construction powder coated panel incoming and outgoing breaker details as per the technical specification, SLD & as mentioned below. Incomer:  1 No – 250A 4P 35kA MP MCCB with1 Set – 250/5A CT CL 1.0 15VA for metering, 1 No. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Set –LED type RYB indication lamp with control MCBs. 1 Set –LED type ON/OFF indication lamp with control MCBs. Outgoings: 2 Nos - 250A TPN35kA MCCB with 60 HP S/D Starter, 2 Nos - 63A TPN 25kAMCCB with jockey pump 10HP S/D Starter,2 No. 63A TP+N 25KA MCCB Bus bar rating: One set: 300A TPN 35KA for 1 sec. CU. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. PH:1R 30 x 10mm CU.Flat,N: 1R 25 x 10mm CU.Flat,E: 1R 25x3mm Cu.Flat
372Cable adopter box(to be provided near the chiller with suitable bus bar extension for the incoming and outgoing feeders with 6 runs of 3.5cx300sqmm XLPE Al.Ar. ) and connected to chiller
373RISING MAIN
374Supply of 3P+100% 4W 50kA 800A Copper Air Insulated Rising Main with external Copper 25/3mm 2runs.
375Indoor IP54 with Plug in Points. Inclusive of Plug in Points, Vertical Brackets and Fire Barriers at each floor crossings.
376plug in- Hole 63A to 200A
377Tap off Boxes: Supply, Erection, Testing and Commissioning of 63-100-160-250A TPN 50KA Ics MCCB with O/L, S/C Releases. Tap off Boxes for tapping supply from vertical rising mains.
378plug in box 4P 63A MCB
379End Feed Unit with 4P 800A 50kA TM Based MCCB
38025 x 3 mm copper flat as body earthing of the Rising Main on both sides with necessary accessories.
381Supply and fixing of the following accessories required for the above rising main erection.
382Flange End
383End closure
384Supply,installation,testing andcommissioningofthe followingMCCBs / MCBs / ISOLATORs / STARTERs of type-II coordination etc.in manufacturer"s sheet steel enclosures, IP 20 Protection, fixed on the concealed wall including all interconnections and accessories. Supply, Installation, testing and commissioning of of cubicle type floor mounting/wall mounting isolator panel. The rate shall be inclusive of suitable MS angle ion standand suitable size enclosure with adopter boxes for cable termiantion,spread bar,etc.
38525A DP MCB along with moulded front plate in GI anodized box
386100A TPN Isolator(MCCB type)with enclosurefor ups/VRF
38763A TPN Isolator(MCCB type)with enclosurefor ups/VRF
38840A TPN(MCB type)
38916ADPMCB with STEEL ENCLOSURE
39063A TPN RCCB 300MA IP66with metal power coated steel enclosureforVRF
391DISTRIBUTION BOARDS
392VTPN 6 WAY (Vertical TPN) MCCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type VTPN 8 way MCCB DB comprising of the following : INCIMER: 100A TPN MCCB 16 KA – 1No. as incomer with ELM OUTGOING:40A TP MCB 10kA (C-Curve) – 6 Nos..as outgoings. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.
393LDB - 4 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following : INCIMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No. 25A DPMCB WITH 25A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 25A DP RCBO outgoing consist of 4nos.6\16\20 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.
394PDB - 4 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following : INCIMER: 63A TPN MCB 10kA with all necessary connected accessories – 1No. 32A DP RCBO 100 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP ELCB 100MAWITH 40A DP MCB outgoing consist of 4nos.6\16\20 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.
395UPSSPN DB : Supply, fixing, testing and commissioning of the Singledoor type compartmental8 way MCB DB comprising of the following : INCIMER: 1no - 16/40A DP RCBO, 1 No. OUTGOING: 6 Nos 6\16\20a 10 KA MCB
396SPN DB : Supply, fixing, testing and commissioning of the Singledoor type compartmental8 way MCB DB comprising of the following : INCIMER: 1no - 16/40A DPMCB, 1 No. OUTGOING: 6 Nos 6\16\20a 10 KA MCB
397LDB-STREET LIGHT: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4 way MCB DB comprising of the following : INCIMER: 1no - 63A TPN MCB, 1 No. 0-24 Hrs. timer with contactor OUTGOING: 2nos - 16/63A TP EL+MCB, 6nos - 6/10A DP EL+MCB With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.
398CABLES AND TERMINATION:For all items in section-D, the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same Supply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/aluminium armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided
3993.5 Core 400 Sq.mm XLPE Aluminium armoured Cable
4003.5 Core 300 Sq.mm XLPE Aluminium armoured Cable
4013.5 Core 185 Sq.mm XLPE Aluminium armoured Cable
4023.5 Core 120 Sq.mm XLPE Aluminium armoured Cable
4033.5 Core 95 Sq.mm XLPE Aluminium armoured Cable
4043.5 Core 70 Sq.mm XLPE Aluminium armoured Cable
4053.5 Core 50 Sq.mm XLPE Aluminium armoured Cable
4064 Core 25 Sq.mm XLPE Aluminium armoured Cable
4074 Core 16 Sq.mm XLPE Aluminium armoured Cable
4084 Core 10 Sq.mm XLPE Copper armoured Cable
4095CX6SQMM COPPER CABLE IN HDPE PIPEFOR STREET LIGHT
4104 Core 6 Sq.mm XLPE Copper armoured Cable
4114 Core 4 Sq.mm XLPE Copper armoured Cable
4123 Core 4 Sq.mm PVC Copper armoured Cable
4131 Core 35 Sq.mm PVC Copper Flexible Cable for
4141 Core 25 Sq.mm PVC Copper Unarmoured Cable
4151 Core 25 Sq.mm PVC Copper Flexible Cable for
4161 Core 16 Sq.mm PVC Copper Unarmoured Cable
4171 Core 16 Sq.mm PVC Copper Flexible Cable for
418Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable)
4193.5 Core 400 Sq.mm XLPE Aluminium armoured Cable
4203.5 Core 300 Sq.mm XLPE Aluminium armoured Cable
4213.5 Core 185 Sq.mm XLPE Aluminium armoured Cable
4223.5 Core 120 Sq.mm XLPE Aluminium armoured Cable
4233.5 Core 95 Sq.mm XLPE Aluminium armoured Cable
4243.5 Core 70 Sq.mm XLPE Aluminium armoured Cable
4253.5 Core 50 Sq.mm XLPE Aluminium armoured Cable
4264 Core 25 Sq.mm XLPE Aluminium armoured Cable
4274 Core 16 Sq.mm XLPE Aluminium armoured Cable
4284 Core 10 Sq.mm XLPE Copper armoured Cable
4294 Core 6 Sq.mm XLPE Copper armoured Cable
4305CX6SQMM COPPER CABLE I
4314 Core 4 Sq.mm XLPE Copper armoured Cable
4323 Core 4 Sq.mm PVC Copper armoured Cable
4331 Core 35 Sq.mm PVC Copper Flexible Cable for
4341 Core 25 Sq.mm PVC Copper Unarmoured Cable
4351 Core 25 Sq.mm PVC Copper Flexible Cable for
4361 Core 16 Sq.mm PVC Copper Unarmoured Cable
4371 Core 16 Sq.mm PVC Copper Flexible Cable for
438TRENCHING AND EXCAVATION
439Excavating the ground for a Depth of 0.75 Mtrs for LT cables with required widthfor laying the LT Cables. After filling the excavated trench with sand of 150mm before and after laying cable Including supply,erecting brick laying over thecables This excavation will be measured for each route only- not for each cables
440Excavation of hard Rock, Removal of Soil,Back filling and restoring to normal state. the following size cable trench in soft soil including excavation, river sand cushioning (150mm thick both at top and bottom of the cable), back filling, ramming and compacting the soil,etc., as required.(600mm depth,300mm width for street light)
441Supply, laying of 100mm dia HDPE Pipe flexiblelayed /clamped in the existing wall/ground with suitable supportsfor street light cable
442Supplying, fixing, HT/ LTcable route markers with 10 cm x 10 cm x 5mm. thick CI plate with inscription thereon,bolted / welded to 35mm x 35 mm x 6 mm. angle iron , 60 cm. long andfixing the same in ground as required.The cable route marker shall be fixed at both the ends of cable at joints and at 100 Mts. spacing for straight runs.
443WIRING - CIRCUIT CUM POINT WIRING The rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified.
444Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturer"s mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit
445Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above.
446Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point.
447TWO-WAY POINTS SITC of Concealed Point wiring (from Switch board) including Concealed Circuit Wiring (from DB to switch board) for two way like staircase points after cutting grooves on wall/ RCC, neatly filling the grooves with cement mortar,making good thereof, etc. using 3 x 1.5 Sq. mm.heavy duty PVC insulated copper conductor stranded cable (1 for earthing),2 Nos. Modular 2-way switch complete with non metallic inner & outer plates, suitable metal boxes, etc,IS marked(IS 9537 Part-3) suitably sized heavy duty rigid concealedMS conduits (20mm min), Saddles, junction boxes, bends, other accessories, ceiling roses, etc.
448Ceiling Fan Points: Supply,installation,testingand commissioning of ceiling fan points same asPrimary Light Point Wiringbut for ceiling fan points including supplying and fixing concealed type fan hook box and supply and fixing of electronic type 300W fan step regulator with moulded front plate in GI anodised manufacturer"s mounting box fixed flush with the wall complete with all accessories as required as per the site conditions.
449Ex Fan Points: Supply,installation,testingand commissioning of Ex-fan points same as Primary Light Point Wiringbut for exhaust fan points including supplying and fixing one no 6A switch with indicator in switch board and one no 6A socket near Exfan location in wallwith moulded front plate in GI anodised manufacturer"s mounting box fixed flush with the wall complete with all accessories as required as per the site conditions. in MS conduits
450Emergency Lighting Circuits: Supply and laying of 3 Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MSconduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition.,from ELDB to Emergency Light fittings.
451Supply and Wiring to the lift well light points using 3 Runs of 1.5 sq.mm. multistrand PVC insulated copper conductor wires (FRLS) in suitable size 1.8mm thick MS conduit in open system including supply of 5A switch in MS mounting box fixed flush with the wall for light points inside the wall. (for 3 Lift shafts).
452Supply and Wiring to the lift well power points using 3 Runs of 1.5 sq.mm. multistrand PVC insulated copper conductor wires (FRLS) in suitable size 1.8mm thick MS conduit in open system including supply of5 A Switched Socket combined in MS mounting box fixed flush with the wall for 5 Amps Socketsinside the Lift Shaft.(for 3Lift shafts).
45320W-Integrated LED Bulk Head luminaire comprises of Pressure Die Cast housing,bajaj BLWCO 20W LED
454Providing and fixing/ laying of conduit and wires for Light point wiring with 1.5 sq. mm PVC insulated, FRLS, copper conductor (stranded) 1100V grade wires alongwith earthing in 25mm dia. medium duty PVCconcealed conduit system including providing and fixing one no. 10 Amp single pole modular switch grid plate mounted with moulded cover plate in zinc chromate passivated GI box suitable for modular switch, complete in all respect (wiring & conduiting up to switchboard not included in item cost), for one light point controlled by one switch. Including making zaries in the wall and finishing the same
455Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above.
456TWIN Providing and fixing/ laying of conduit and wires for Light point wiring with 1.5 sq. mm PVC insulated, FRLS, copper conductor (stranded) 1100V grade wires alongwith earthing in 25mm dia. medium duty PVC concealed conduit system including providing and fixing one no. 10 Amp single pole modularswitch grid plate mounted with moulded cover plate in zinc chromate passivated GI box suitable for modular switch, complete in all respect (wiring & conduiting up to switchboard not included in item cost), for controlled by 2 nos. 2 way switch. Including making zaries in the wall and finishing the same
457Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point.
458CEILING FAN "Providing and fixing/ laying of conduit and wires for Ceiling fan point wiring with 1.5 sq. mm PVC insulated, FRLS, Cu. conductor (stranded) 1100V grade wires alongwith earthing in 25 mm dia. Medium duty PVC surface/ concealed conduit system including providing and fixing one no. modular 10A single way switch, grid plate mounted with moulded cover plate, two module electronic stepped fan regulator in zinc chromate passivated GI box suitable for modular switches, with GI box for fan suspension, complete in all respect. Including making zaries in the wall and finishing the same
459Providing and fixing/ laying of conduit and wires for Exhaust / Brackat fan point wiring with 1.5 sq. mm PVC insulated, FRLS, Cu. conductor (stranded) 1100V grade wires alongwith earthing in 25 mm dia. Medium duty PVC surface/ concealed conduit system including providing and fixing one no. modular 10A single way switch, grid plate mounted with moulded cover plate in zinc chromate passivated GI box suitable for modular switches complete in all respect. Including making zaries in the wall and finishing the same
460Emergency Lighting Circuits: Supply and laying of 3 Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8 mm thick PVC conduit concealed in the wallwith necessary clamps, screws, etc., as required as per the site condition.,from ELDB to Emergency Light fittings.
461SOCKETS
462Supply, Installation, testing and commissioning of 1 no 6A Universal switched socketand withmoulded frontplate, GIanodised enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points.
463Supply, Installation, testing and commissioning of 2nos 6AUniversal switched socket ( UPS) and 2nos 6A switches and withmoulded frontplate, GIanodised enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points.
464Supply, Installation, testing and commissioning of 1 no 6/16A universal switched socket and withmoulded frontplate GIanodised enclosure in the wall/floor(concealed/open andother associated accessories including chasing embeddingrough plastering as required as per the site conditionsforpower points.
46516 A SOCKET:Supply, Erection,Testing and commissioning of 16 A Socket.Make : WIPRO
466Supply, Erection,Testing and commissioning of 32A 3Phase Metal clad plug and socket with 32 A TP MCB as control with enclosure,Plug top cover and connected accessories . Legrand cat no 056614
467Supply and installation of Power supply cables for various instruments, data converters, data logger,control room equipment etc connected to Energy management system.
468Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.).
469Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick PVC conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.).
470Supply & Laying of 2R 2.5sqmm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires in the 20mm dia 2mm thickMS conduits with all accessories as reqd. (From DB to 6A Switch & Sockets)
471Supply & Laying of 2R 2.5sqmm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires in the 20mm dia 2mm thick PVC conduits with all accessories as reqd. (From DB to 6A Switch & Sockets)
472Supply & Laying of 2R 2.5sqmm and 1R 1.5 Sq.mm. PVC insulated FRLS multistranded cu wires with laid in existing conduit or Raceways all accessories as reqd. (From DB to 6A Switch & Sockets)
473Supply & Laying of 2R 2.5sqmm and 1R 1.5 Sq.mm. PVC insulated FRLS multistranded cu wires with laid in existing conduit or Raceways all accessories as reqd. (From DB to 6A Switch & Sockets)
474Supply & Laying of 1cx4sqmm FRLS PVCCu wires
475Supply & Laying of 1CX1.5sqmm FRLS PVC cu wires
476LIGHT FITTING
477Supply of 2"X2" architectural decorative Recess mounted LED with endorsed lens on each LED and LEDs should be arranged in four rows with 45 deg tilt anlge to cut the glare:  CRCA powder coated housing with ABS plastic top cover for better aesthetic finish and high efficient PMMA diffuser on the wall, electronic driver duly wired upto terminal block, Wattage = 30W  Luminaire lumen= 3000lm, LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and system Efficacy of > 100lm/W,  Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM = 3.0KV, Driver Voltage range 150-270V AC and  Safety Extra Low Voltage Safe level<60V DC as per IEC standard also driver shall be capable of auto restart post auto shut off if the voltage greater 325V, Electrical Safety with Class 1 Insulation, Luminaire luminous Efficacy=100lm/W. Driver shall be potted driver and both driver and luminaire shall be BIS compliance. driver shall be potted driver and both driver and luminaire shall be BIS compliance. Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%.CAT REF.NO : PHILIPS S740B/RC LED30S/840 W60L60 PSU WH OR EQL
478Supply of LED downlighter compatible for cell ceiling with system wattage not more than 18W and luminaire lumens not less than 1800 lumens. The system efficacy shall be > 100 lm/W. The housing shall be die-cast aluminium with diffused optics with polycarbonate diffuser for better distribution of light.LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 150lm/W,Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM = 2.5KV, LED Driver with Voltage range 150-270V AC andSafety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Driver shall be potted driver with three terminals of P,L,E and both driver and luminaire shall be BIS compliance. Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%.
479Supply of surface LED downlighter system wattage not more than 12W and luminaire lumens not less than 1200 lumens. The system efficacy shall be > 100 lm/W, cut out dia shall not greater than 85mm. The housing shall be die-cast aluminium with deep recessed optics with low glare and reflecter shall be matt black in color. Luminaire shall be compatible to access/replace the LED moudle without removing the trim from the ceilng. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 130lm/W,Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 90, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM = 2.5KV, LED Driver with Voltage range 150-270V AC andSafety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Luminaire shall be BIS compliance.Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5% CAT REF.NO :WIPRO LD90-231-XXX-65-XX OR EQL
480Supply of IP65 4" LED luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application.The luminaire shall be with all-weather polycarbonate housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The luminaire shall be with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be < 36W with system lumens of > 4400 lumens and system efficacy of > 100 lm / W. LED make:that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 150lm/W,Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 70, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM = 4.0KV, Constant Current - Constant Voltage LED Driver with APFC Construction, LED Driver Voltage range 150-270V AC andSafety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation.CAT REF.NO :WIPROLL24-541-XXX-57-XX OR EQL
481Supply, Installation, including assembling, testing and commissioning of Wall mounted MIRRORdown light fitting with 9W or 10W LED lamps and suItable drivers for Mirror light fitting.
482Supply, Erection, testing and commissioning of Cove/Strip light with 1 x 20WEACH 5M LED COOL white with driver and with all accessories and interconnecting with 3 core 1.5 sqmm PVC insulated multistrand wires and accessories as required.Crompton cat no LST20CDL/BL/WW
483Orient Electric 10W LED Inverter Emergency Batten (White, Square)
484Low glare, height efficiency SURFACE mounted LED down light - CIRCULAR profile-LCRP-10-CDL ( Royal Rimless)
48540W TUBE LIGHT
486Supply, Installation, testing and commissioning of1200mm sweep Ceiling fanand fixing the samewith extended rod from roof, required clamps,bolts,fan hook , screws ,hardwares as required as per the site condition -BEE 5 Star rated white colour double ball bearing model noORIENTmake AEROQUIET OR EQVT
487Supply and fixing of Bulk head fitting of PHILIPS make CAT: Philips 10 W WT202W LED6S CW PSU S2 PC Endura LED Bulkhead, 6500 K (or) Crompton cat ICBH10 OR equivalent in the lift shaft.
488Supply, Installation, testing and commissioning of heavy duty motortotally enclosed with die cast aluminium rotor mounted on two ball bearings 300 mm dia1400 RPM single phase Exhaust fan with die cast Al body and CRCA steel blades and minimum air delivery of 1710 cum/hr. and fixing the same including making hole to suit the size of ex.fan and fixing the same in the wallwith wooden blocks, screws ,hardware as required as per the site condition
489Supply and fixing of Chandelierfitting of TISVAmake CAT: BAROQUE / ODHESA With 5wLED IN CEILING AT RECEPTION
490Supply and installation of 3wEXIT/ toilet double sided signageLIGHT 180 min back uppolite auto glo ip 44or eqvt with CABLE and 5a pin incl hanging arrangement cat no LED EM(S)
49150MM Dia GI Pipe Wall bracket WITHTerrace lighting/WallFLOOD Lighting WITH 50W led Crompton LIGHTLFLE-50-CDL- SECURITY AND OFFICE TERRACEFOR HVAC PANEL SERVICING
492Supply, fixing ,testing and commissioning of AC chargeable emergency lamp with 2x4W ledlamps with all connected accessories -PROLITE Self contained rechargeable emergency light 2x4watts with battery 12v 2.3 AH 120 MIN BACKUP -PEL LED LTBL With Cable and 5a pin
493Supply erection of Integral decorative LED bollard with opal acrylic with IP65 Protection-Bajaj cat no BGBOM 650 9W LED ww - or eqvt incl concrete foundation as per item no 176, incljunction box WIPRO LB14-880-XXX-65-05
494LED TRACK LIGHT FOR RECEPTION-WIPRO LD 57-251-036-40-XX OR EQVT with alu support
495Suspended type linear in sleek designCROMPTON LCLP54-72-CDLN OR EQVT
496CABLE TRAY
497CABLE TRAYS Supply and erection of following size 2mm thickLadder type,Pregalvanized, cable trays and cable tray of rolledGI Sheet, supports out sections, pipes, plates, etc. including welding, anchor bolts, threaded down rods(for 300 mm trays only), supply of necessary anchor bolts and grouting etc. including breaking walls, floors, etc. for structures as required including supply of all GI hardware materials, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-charge.The rate shall include supply & fixing of MS Grip bolts in columns/beams/walls/ceiling etc.as required & including drilling also. Rod supports shall be of galvanized full threaded rods of sizes 8,10 & 12mm dia for fixing to anchor fastener, anchor bolts.The length of the full threaded rods for the purposes of quoting shall be 1200 mm & includes nuts & washers and supports shall be at a min.distance of 1Mtr.The rate will include all required bends, tees, vertical up & downs, radius bends and other applicable accessories shall be factory fabricated, complete & as required. The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc,(8 mm threaded rod shall be providedat every alternative purlin appx. 2 mtr length)
498600 x 70mm x2mmLadder type cable trays
499300 x 50mm x2mm Ladder type cable trays
500150 x 50mm x2mmLadder type cable trays
501Supply and fixing of Perforated Cable traywith horizontal & vertical bends, reducers, Tee"s, cross over , suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr . incl cover for vertical areas The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc,(8 mm threaded rod shall be providedat every alternative purlin appx. 2 mtr length)
502450 mm width X 62.5 mm depth X 2.0 mm thickness
503300 x 50mm x1.6mm
504100 x 50mm x1.6mm
505RACEWAYS & JUNCTION BOX
506RACEWAYS :Supply, installation & fixing of the following size of Raceways made out of 2,mm thick galvanized sheet steelwith Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.
507100x38X2mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical accessunits, singlecompartment as specified incl joint sleeves
508200x38X2mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical accessunits, singlecompartment as specified incl joint sleeves
509JUNCTION BOX :Supply, installation & fixing of the following size of junction boxes made out of 3 mm thick galvanized sheet steel junction boxes with top SS cover good finishing Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.
510110 mm X 50 mm
511210 mm X 50 mm
512310 mm X 50 mm
513UPS AND INVERTER
514Supply & testing of 3 KVA INVERTER 1 Ph-in/1ph-out with 30Min backup with necessary mounting arrangement etc., Complete wiring required between the Inverter and it"s battery banks & Battery Stands.The cost shall be inclusive of Structural steel supports etc.,
515Supply, Fixing, Testing and commissioning of the 5 kVA UPS systemThree phase input and single phase outputwith 30 Minits. battery backup with suitable Maintenance free battery,battery breaker, MS cabinet & interconnecting cables and all as per the detailed specification enclosed.as per the detailed specification enclosed. (For TIDEL PARK OFFICE).
516EARTHING
517Supply of UL Listed & CPRI Tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 ( OBO Type No. 17 3000 CCER)& is provided with universal clamp made ofSS to connect rod with flat conductor ( OBO Type No. 17 25 RTC) . Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided withHeavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system(OBO Type No.UFE) .for LT panels, cable trays,
518Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing .
51950X10 mm GI . Flat for panel cable tray Body earthing
520Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
521Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
52210 SWG Cu. Wire for Gland earthing
5238 SWG Cu. Wire for DBs earthing
52425X3mm Cu Flat forearthing
525STREET LIGHTING -- MAIN ROADS The rate includes excavation and foundation for erecting thereferred street light pole as required at site and inclusive of necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. each arm with light- The pole shall be grouted inside ground pit (cross section 600 x 600 mm)with cement concrete 1:2:4 with necessary GI ‘A’ class pipes (not less than 38 mm dia, NB) to facilitate pulling of cables. Separate pipes shall be provided for incoming and outgoing cables. The cement concrete shall be protected from premature drying by curing for at least seven days after pouring. All concrete surfaces from 150 mm below ground level to top shall be finished smooth with cement mortar 1:4.-pole height above ground -7-m-top 70mm,bottom 130mm,thickness 3mm,with base plate size220x220x16mm-4nos foundation bolts,700 mm length 24mm dia.
526Supply, erection, testingand commissioning ofstreet light fitting with 1x120W LED lamp, driver,fixed on 6.25m(above ground) swaged MStubular polesconfirming to IS1161,-Swaged and 1.5 m angle arm - Single armconventional bracket for mounting fitting ,bracket assembly on to the pole top by means of angular rings , foundation base plate,ribs,4 fixing bolts (600mm anchoring bolt with 90 degree bend, including red oxide paint 24mm rod with 2nos PL Washers and 3nos nuts) anchoring bolt,cable entry pipe, poles treated for corrosion protection, earthing arrangement, excavation and back filling, supplying and laying cables through Hansel make weather proofjunction box withDP 3 ampsMCB ,wiring with 3x2.5 Sq.mm PVC insulated 1100 volts grade copper conductor wires from junction box to lighting fixture complete as required. finish to be of approved colour.Entire application shall confirm to IS2713 for Tubular Steel Poles for Overhead Power lines including numbering of poles. 4 way 30 A rated terminal block for loop in & loop out cable arrangements coil earthing etc.The pole shall be painted with one coat of primer and two coats of enamel paint,with 1Mtr long 25mm dia "B" class G.I. Pipe as earth electrode with charcoal ,Salt with 10SWG copper wire interconnected with street light pole. cable entry G.I pipe of 2.5" dia. as per Drg and Technical Specification.- Crompton LSTP 120 CDL M- or equivalent approved make
527Supply, erection, testingand commissioning ofstreet light fitting with 1x120W LED lamp same as above item but with Double Arm
528FLOOD LIGHT: Supply , Fixing, testing and commissioning of Integral flood light luminaire single piece pressure die cast aluminium housing, toughened glass cover with IP 65 protection with 1 x 45W led lamp forwithdriver and fixing the same on the outer columnwith necessary fixing hardwares as required as per the site condition. etc., (Crompton cat no LSFO 45 CDL OR equivalent)
529Facade Lighting: Supply and erection of plinth / peripheral wall / Pole mounted 72W weather proof FLOOD LIGHT with necessary DRIVERetc.all complete for enlightens the elevation of the building.The scope includes construction of necessary plinth to the required height of Architect / Consultants and all other connected civil / other such work.The scope also includes providing necessary mounting brackets, lamp pilferage arrangement etc. to the satisfaction of the Architects / Building Managers.Assymmetical flood light fitting with IP: 65,
530Supply and fixing of weather proof loop in loop out boxmade out MS sheet steel enclosure with 4Way 20A rated terminal block for the above landscaping , Terrace, post top light fittings with necessary fixing hardwares required as per the site condition.
531Supply erection of entrance gate light 45w LED K LITE Cat No Maugham/ imperial/ crown- as per client choice
532SAFETY EQUIPMENTS:
533Supply and laying ofLT 2mm thick electrolytic grade rubber matas per ISI IS 15652-2006 of size 2000x1000 mm in front of the LT panel boards.
534FIRE EXTINGUISHER Supply, erecting and connecting a 6 KG ABC fire extinguisherpowder type properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of fires (A, B & C).
535Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher with gun metal cap , nozzle,with initial fill properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of fires (A, B & C).to TAC norms
536Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white insideand red outsideandblackon the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.
537Supply, erecting and connecting laminated shock treatment chart both in English and local language directly fixed in the glazed frame on to the wall with necessary screws on all four corners.
538Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,)
539Supply of 1100 V Tested Gloves with Box
540Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in local language and English
541MISC ITEMS:
542Supply and providing of 6mm thick MS Chequered Plates as floor separators for covering the shafts with angle iron supports at floor level to form a complete fire barrier protection between two floors and to cover thegaps around the cable trench etc., in the duct.
543Supply, Fabrication, Erection of structural steel including 2 coats of red oxide primer & 2 coats of approved enamel paint .Items including all channels and angles, suspension supports, steel plate, anchor bolts, cross angles, brackets, etc. including grouting, welding, tools, tackles as required etc. The payment shall be made for the actual quantities measured. This item shall be operated for tray supports in cable trenches, cable trays, Mounting frames for panels and DBs., vertical tray supports et,panel, busduct supports
544WALL/POLEmounted cable junction boxes
545Supply and laying of 25mm dia 2mm thick MS Conduit with all connected accessories.
546Supply and laying of 32mm dia 2mm thick MS Conduit with all connected accessories.
547Supply and laying of 40mm dia 2mm thick MS Conduit with all connected accessories.
548Supply and laying of 50mm dia 2mm thick MS Conduit with all connected accessories.
549Supply and laying of 20mm dia Heavy duty PVC Conduit with all connected accessories.
550Supply and laying of 25mm dia Heavy duty PVC Conduit with all connected accessories.
551Supply and laying of 32mm dia Heavy duty PVC Conduit with all connected accessories.
552Supply and laying of 50mm dia Heavy duty PVC Conduit with all connected accessories.
553Supply and laying of 25mm dia 2mm thick GI Conduit with all connected accessories. FOR flame proof lighting class A
554Supply & Erection of Cable Tags as per the Cable Schedule.
555Liaison with the Chief Electrical Inspector to Govt., /CEA for preparation ofWorking drawings etc., obtaining approval for drawing.Preparation of completion Report, Arranging for Inspection and attending to defects report and preparation of as fitteddrawings and obtaining Safety Certificate fromCEIG /CEA for commissioning. Liaison with the Chief Electrical Inspector to Govt., for issue of Safety certificate approval for energisation. clearance from SUPPLIER includingfor installation and running DG set.The works executed as built drawings need to be submitted in the blue print of A1 sizein 4 Sets of hard copy and two set sets of soft copy in CD.The necessary statutory fees/charges will be paid by the client against demand advice.
556NETWORKING
557MOLEX MAKE OR EQVT
558Supply and laying of Cat 6A 4Pair UTP Cable (Box of 500 Mtr) with all connected accessories for DATA-blue
559Supply and Fixing of Cat 6A 48Port Unloaded Jack Panelfor data
560Supply and Fixing of Cat 6A UTP Jackfor Data -Blue Color forRack Side
561Supply and Fixing of Cat 6AUTP Jackfor Data -Blue Color forWorkstation Side
5622Port Wall Plate Square Type Face Plates WITH BACK BOX
5631Port Wall Plate Square Type Face Plates with back box
564Cat 6A stranded Patch cord 1 Meter - Blue for Rack side
565Cat 6A stranded Patch cord 2 Meter - Blue for WS side
566Supply and laying of 25mm dia Heavy duty PVC Conduit with all connected accessories.
567Cat 6A4Pair Shielded net workCablefor connectivity BLUE
568Voice connectivity
569Supply and laying of Cat 6A 4Pair UTP Cable (Box of 500 Mtr) with all connected accessories for VOICC
570Supply and Fixing of Cat 6A UTP Jack forVoice -Yellow Color atRack Side
571Supply and Fixing of Cat 6A 48Port Unloaded Jack Panelfor Voice
572Cat5e UTP 48-port Non-Shutter Patch Panel, loaded ,resources (EBPAX) Side
573Supply and Fixing of Cat 6A UTP Jack forVoice -Yellow Color atUser End
574Supply and Fixing of Cat 6A , stranded Patch cord 1 Meter - Blue for Rack side
575Supply and Fixing of Cat 6A , stranded Patch cord 2 Meter - Blue for User End
576Cat.3 50pr UTP Cable 305m/reel Grey_CMR
57720+20 MDF KRONE
578Hookup Wire-100 mtr
579Fiber Back Bone Cabling
580Supply and laying of 12 core OFC fiber Single mode
58110 Pair DB
582Cat5e UTP 50 Port Telephone Patch Panel
58315U Wall Mounting rack, 600/500D with Front Glass door & Rear Plain Door with handle lock, 1 Shelf 400mm and mounting hardware packet of 20, Cable Manager, PDU 6sockets (1),Side panel mountable Rittal make
584Supply, installation, testing and commissioning ofRiser cable consisting of multiple /50 core or solid copper conductors of 24 AWG size insulated with expanded polyethylene covered by a PVC skin and inner shielding for grounding. The core shall be covered by a layer of plastic tape and overlaid with a corrugated PVC plastic.The cable shall be as per the specifications laid down in the tenderincluding termination and all required accessories
585Data converter with 24 v DC power supply-SCHNEIDER
586Schneider PME -EMS software FOR 50 NODES
587RS 485 COMMUNICATION CABLE
588CAT 6A SHIELDED CABLEFOR OUTDOOR
589LIGHTNING PROTECTION SYSTEM
590Supply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No.RD 8/ALU I (5450 08 6)
591Supply of Roof conductor holderfor parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distanceOBO Type No.177 30 M8(5207 46 0 )
592Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance.OBO Type No.165 MBG 8-10 ( 5218 70 0)
593Providing of cross universal connector: For T and cross connection,to route vertical down conductor /mesh formation made of hot dipped galvanisediron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . OBO Type No.251 8-10 ( 5312 03 5 )
594Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 )Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). OBO Type No. 249 8-10 ST ( 5311 50 0 )
595Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 )Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). OBO Type No. 249 8-10 ST ( 5311 50 0 )
596Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod : Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) 4Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. OBO Type No. 101 VL 4000 ( 5401 99 5 ).
597Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. OBO Type No. F-FIX 16 ( 5403 20 0 ).
598Down Conductor
599Supply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No.RD 8/ALU I (5450 08 6)
600Supply of conductor holderfor sidewall- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distanceOBO Type No.177 30 M8(5207 46 0 )
601Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by EngineerOBO Type No. 271 8-10 ( 5317 40 1 )
602Enclosure for Test joint: RoHS Complied, IP66, 6mm², 500V, IK08, UV resistant, Halogen free Thermoplastic junction box ,installation of cables either directly through the 7 x M25 seals, polypropylene,Light grey. Overall Dimensions: 114mm X 114mm X57mm, Internal Dimensions: 100mm X 100mm X 48mmOBO TYPE : T 60 (2007 061)
603Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6.OBO Type No. LSC I+II ( 5091 72 2 )
604Earthing
605Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx:70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding.OBO Type No. 5052 DIN 30X3 ( 5019 34 4 )
606Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314 53 4 )
607Providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts.OBO Type No. 166 LS 70 (5226570)
608Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. OBO Type No.356 50 ( 2360 05 5 ) B369
609Supply of CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 ( OBO Type No. 14 3000 CCER)& is provided with universal clamp made of SS to connect rod with flat conductor ( OBO Type No. 14 25 RTC) . Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested(OBO Type No.OEC 2 25) . The above arrangements shall be provided withHeavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system(OBO Type No.UFE) .
610same as item 62
611same as item 62
612same as item 62
613SOLAR GRID CONNECTED
614Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required- 10.3 KW SOLAR SYSTEM
61556 NOS 450 Wp Solar PV Panels,Structure, Earthing, Wiring, and other accessories,Power Conditioning Unit(PCU) 25 kWp,3 PH INVERTER, CABLES ,CARTAGE, INCLINSTALLATION CHARGES , FASTNERS,CABLE TIE, CRIMPING TOOLS,EARTH KIT,5years warranty for complete set, 25 year warranty for solar panel
616Supply & Installation of 450 Wp OR HIGHER - 144 cells Mono Perce SPV Modules,Supply & installation of 25 KW - Three Phase Ongrid String Inverter,RCC roof SPV Mounting System,MMS: Supply & installation of 2mm Galvanised Iron (GI) C-Purlin (40 X 80 X 40mm),SS Fastner for MMS & Module,CIVIL : M15 (1 : 2 : 4) Ratio 300 x 300 x 300 mm concrete pedestal,DC Cable :16 Sqmm Single Core UV Resistive Solar PV Copper Cable-120M,AC Cable : 16 Sqmm 4 Core Aluminium Armoured cable-40M,Earthing Cable : 6 SQ MM-80M,Array Junction Box & Connectors :DCDB : 2 IN 2 Out with 2 SPD (Surge Prodction Device with DC MCB)-1SET,ACDB : 1IN 1 Out with Three SPD (Surge Production Device with AC MCB)-1SET,UV Resistive MC4 Connectors-4M -NOS,Electrical Conduit Pipe :50mm Pvc conduit pipe-10M,50mm Flexible PVC Hose-10M,60mm Flexible Metal Hose-10M,INCL OTHER ACCESSORIES,Earthing & Lightning Arrestor :-17.2mm Dia 1.2Mtr Length Copper Bonded Rod with 25Kg Earthing Compound-3SETS,1.2Mtr Multi Spike Lightning Arrestor-1SET
617DIESEL GENERATOR
618S.I.T.C of1 No. of 380 KVA DG sets with Acoustic Enclosure, AMF Control Panels & connected works such as Exhaust Pipe & Exhaust stack with supporting arrangements,Earthing and other associated works etc,.
619Design, manufacture, Supply and Transportation, Installation, Testing and Commissioning of the380KVAcontinuous Prime Duty DG set inside the Acoustic Enclosure, 1500 rpm, four stroke, designed for operating on HSD, 415V,3Phase,50Hz,0.8pf,4wire AC complete with all accessories, like base frame,vibration bellow and includes the following transport, insurance, handling, safe keeping at site etc., erection, installation, testingand commissioning, excluding civil foundations and trenches inside the Acoustic enclosure andaccess ladderfor DG set"s radiator watering. The DG set shall be as per the detailed specification enclosed.
620Design, Manufacture, Supply Transportation, Installation, Testing and Commissioning of the Acoustic enclosure suitable for 1 No. 380 KVA radiator water cooled diesel generator with all accessories fabricated with 16 SWG CRCA sheet steel, mineral wool insulation of high density with perforated GI sheet covering, ventilation system complete with fans and louvers, doors, inside temperature controller, inside illumination with energy efficient LED fittings, wiring for light and power plug points with suitable size and number of PVC insulated copper conductor cable on surface MS conduit system, earthing complete as per the Specification enclosed.(The above enclosure should be as per CPCB norms. The current approval certificate shall be submitted by the firm).The rate shall be inclusive of supply of day tank of 990 Litres separately provided outside the acoustic enclosure mounted on a suitable pedestal with weather proof enclosure near to DG set.
621Note: The Acoustic enclosure shall be meeting the noise level requirements as specifiedviz. less than 70 dBA during night time at 6 meters distance from DG sets and less than 75 dBA during daytime at 6 mtr distance from the DG sets with all DG sets operating at full load All necessary civil works for Acoustic Enclosure required to be implemented by other agency shall be listed separately. Noise levels shall be guaranteed by the Bidder. The acoustic treatment shall be as per the detailed specification enclosed.
622SITC of 24Volts, 40Amps, SCR controlled battery charger made up of 16SWG MS sheet enclosure with all accessories having automatic boost and trickle charging arrangements with volt and current limiting circuits, voltmeter for AC/DC supply, ammeter for charging circuit (DC), automatic cut off facility when the Engine alternator is in working condition when the battery is fully charged. MCB for protection, suitable for 230V,50Hz, AC supply, interconnections, body earthing etc. complete as required.
623Design, manufacture, supply, installation,testing and commissioning of 10" (inch) dia MS exhaust pipe class B suitable for 380KVAengine exhaust line (Vertical) including with all accessories such as bends,.flanges, gaskets, condensation removal plug, fixing of flexible coupling, residential silencer supplied along with the engine. Providing necessary MS angle iron supports for the pipe line and the silencer, welding arrangements/ flanged joints with bolts/nuts as perthe site conditions. Terminating the pipe line in duct /shaft including the complete insulation with 50mm thick glass wool, polythene covering, chicken mesh and aluminium claddingcomplete as per the specifications etc. as required.
624Design, Manufacture,Supply, Installation, Testingand Commissioning of the Exhaust Stack suitable for 1 x 380 KVADG set with exhaust gas flow with wind pressure suitable for LOCAL condition and exhaust gas velocity, necessary stiffner rings & flanges, sampling ports, foundation bolts, lightning arrestor, earth strip of 25 x 6mm GI for Earthing stack and LA, insulators, foundation bolts etc. Detail design for civil foundation should be furnished by the supplier well in advance to make the foundation ready by other agency. Design data should be furnished for wind pressure, base diameter and thickness of plate at cone and shaft areas. The rate shall include Lightning Protection, aviation warning lamp( LED type) with photo cell including cabling, termination, control MCB etc. The rate shall include necessary steel structure including necessary supports, Scaffolding charges,necessary bellows etc.,. Exhaust Pipe including necessary painting. The Exhaust stack height will be 10 Mtrs. DG sets to be provided for 1 x 380 kVAEnd of the Exhaust stack shall be design shaped to protect & to avoid rain water entry inside pipe and bended towards wind flow direction at LOCAL condition etc,.
625Design, supply and install - Double canvas cloth interconnection between the radiator and the sound attenuator to avoid transmission of vibration from the DG set to the sound attenuator through the treated duct.
626Design, Manufacture, supplying, erection, testing and commissioning of anti-vibration spring type mounting suitable for 1 No. 380 KVA DG sets.( 1 set = Required anti-vibration spring type mounting for One DG set as per OEM/DEM.)
627Supply, fixing, testing and commissioning of theResidential silencer for the380KVA Prime Duty DG set with complete insulation covering with 50mm thick glass wool, polythene covering, chicken mesh and aluminium claddingcomplete as per the specifications etc. as required.
628Supply and erection of 25 mm dia, Class "B" MSpipe for the interconnection of the Day fuel tank with the engines, with necessarywelding, jointing and painting etc.,
629Design, supply, erection of 600 x 600 x 12 mm CI plate burried in ground in a depth of 3.0 M from ground level with alternate layer of charcoal and slat including supply and fixing of 40 mm dia perforated GI pipe funneling for watering purpose including construction of masonry chamber with RCCtop cover.The thickness of top cover should be suitable for heavy duty vehicle movements. This item covers all earth work, shifting of removed soil
630Supply, erection of3 mtrs long 13mm thick and 100mm dia Cast Iron Pipe electrode earth station. burried in ground in a depth of 3.0 M from ground level with alternate layer of charcoal and slat.The identification number shall be provided both inside and outside.
631Supply and laying of 25 x 6 mm copper flat for 380 KVA generator neutral earthing joint connections brazing.
632Supply and laying of 8 Gauge bare copper wire for Gland earthing.
633Supply and laying of 25 x 3 mm Cu flat for generator body earthing joint connections brazing.
634Supplyng and laying of the following PVC insulated, PVC sheathed armoured Copper conductor cabling from engine control panel tobattery charger, day tank with suitable clamping arrangement, end terminations, earthing the glands, laying on the existing cable tray /trench, painting complete etc. as required.
63516 C x 2.5 sq.mm PVC insulated Copper cable
6364C x 2.5 sq.mm PVC insulated Copper cable
6374C x 1.5 sq.mm PVC insulated Copper cable
6381.5 sqmm PVC insulated Copper cable Screened communciation cable
639supplying and laying of rubber mat of 2 mm thick with ISI : 15652-2006 marked suitable for the 3.3 KV grade etc. as required.(size 1m wide x 2m length)
640Supply and providing of following items.
641Fuel unloading hand pump.
642PVC Hose
643Preparation of the drawing and submission to the statutoryauthorities such as Pollution control board etc, Chief Electrical inspectorate to Govt.,EB for commissioning the system including arranging inspection and also necessary approval / safety certificate from authorities etc. for the Electrical / DG Installation. The necessary statutory fees/charges will be paid by the client against demand advice.
644SANITARY INSTALLATIONS
645Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm or trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The WC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat coverWall Fitting
646Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm or trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The WC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat coverFloorFitting for Handicapped Toilet
647Supplying and fixing of Oval Shape Wash Hand Basin of size 560 x 450mm with all accessories such as 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia "B" Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etc
648Supplying and fixing of Wash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia "B" Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etc - Wash Basin without Pedestal for Handicapped Toilet
649Supplying and fixing of Lipped Mouth Porcelain Flat Back Urinal with all accessories such as 32mm dia Bell Mouth PVC Connection, 15mm dia GM Wheel Value, 15mm dia "B" Class GI Waste Water Pipe, 15mm dia Nylon Connection, 15mm dia Brass Nipple etc.
650Supplying and fixing Stainless Steel Sink of size 600mm x 450mm x 200mm with 32mm dia "B" Class GI Waste Water Pipe and 32mm dia CP Waste Coupling
651Supplying and fixing SS Swan Neck Tap for lab sink
652Supplying and fixing of CP Two Way Bib Cock with Health Faucet with one no. of CP angle cock etc., complete.
653Supplying andfixing stainless steel paper holder with necessary fixing material paper roll etc.complete.
654Supplying andfixingC.P. Robe hook with C.P. screws etc., complete. Fixed on the toilet door
655Supplying and fixingC.P. towel ring with necessary fixing materials
656Supplying and fixingBrass Chromium Plated Towel Rail 60cm long and 20mm dia with Brackets, fixing materials
657Supplying and fixing liquid soap dispenser fixed with necessary fittings etc. complete as directed.
658Supplying andfixingpaper dispenser with necessary fixing materials etc.
659Supplying andfixingelectrically operated automatic hand drier with necessary fixing materials etc.
660Supplying and fixing Grab bar 450mm Long with necessary fixing materials . .
661Supplying andfixing PVC / Fibre Glass Framed 5.5mm thick Mirror, Shelf Type with Hard Board Backing 600mm x 450mm
662Supplying andfixing Special Type Mirror of size 1000 x 780mm
663Supplying andfixingPVC Nahini / Floor Trap with PVC Grating100mm x 75mm & required concrete encasing all around, complete.
664DRAINAGE WORKS
665Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). Internal & Vertical
66650mm dia
66775mm dia
668110mm dia
669Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
670110mm dia - 4kg/Sqcm
671160mm dia - 4kg/Sqcm
672Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark with solvent cement joints confirming to IS 4985 for Under ground drainage works. The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting/encasing the pipes if required in cement concrete M-15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level . (External)
673110mm dia
674160mm dia
675Supplying andfixingPVC cowl to vertical Soil/Waste pipes above terrace level
67675mm dia
677110mm dia
678Construction of gully chamber ofsize 0.23 x0.23x0.3m with (150 mm X 100mm S.W.gully trap) 100 mm dia outlet set inPCC 1:4:8 bed, 120mm thick masonry chamber in CM 1:5, internal and external plastering 12mm thick in CM 1:3, necessary earthwork, C.I. cover (medium duty) etc., complete.
679Providing and constructing Inspection Chambers/ Manhole Chamber/ any other Chamber size 600 x600 mm x450mm to 1000mm deep including necessary excavation in soil/murrum/rock as per required invert level and working space all around, 150mm thick bed of cement concrete in proportion of CC 1:5:10 with 150mm offsets at all around the outer faces of walls, providing and constructing of minimum 230mm thick brick/cement concrete block masonry walls in CM 1:4 , providing and applying 15mm thick water proof plaster in CM 1:3 added with integral waterproofing compound as per manufacturers specifications and finished with a floating coat of neat cement @ 2.2 Kg/SqM at the internal & external faces all around the masonry walls, necessary floor benching and channels in cement concrete 1:1.5:3 of minimum 150mm thick rendered smooth with waterproof plaster followed by neat cement, providing CI circular/square Manhole cover with frame of minimum 600mmX600mm weighing minimum 40 kg (double seal) of approved make and confirming to IS and fixing with reinforced cement concrete 1:1:2 of minimum 150mm thick slab including shuttering, finishing the concrete surface and faces with waterproof plaster/IPS in mild slopes with float of neat cement etc complete as directed.
680600 x600 mm x450mm to 1000mm deep
681900 x 900 mm x 1000mm to 1500mm deep
682Providing and laying non-pressure class NP2 RCC Hume pipes with collars including excavation of trenches in soil/murum/rock, laying the pipes as per layout and drawing, filling the joints with stiff mixture of cement mortar (1 part cement :1part fine sand) and jute, curing, testing the pipe and refilling the trenches in layers with due compaction & watering etc. complete as directed
683200mm dia NP2 RCC Hume Pipe
684250mm dia NP2 RCC Hume Pipe
685Making through holes in Plain or Reinforced Cement Concrete with Diamond Core Drilling System by using BOSCH power tools of following diamete - Depth per cm
686100mm
687150mm
688WATER SUPPLY WORKS
689Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.Internal & Vertical
69015mm dia
69120mm dia
69225mm dia
69332mm dia
69440mm dia
69550mm dia
69665mm dia
69780mm dia
698Supplying, laying, jointing, testing & Commissioning of uPVC Schedule 80 pressure pipes as per ASTM D 1785 with Sch 80 Fittings as perspecifications, jointing with hold tite / super tite & tefflon tape and complete with fittingssuch as sockets, unions, reducers long or short bends, elbows, nipples flanges,checknuts,etc. Pressure testing of piping and back filling of trench complete as required. The quoted rate shall include necessary earth works, fittings like Tees, Bends, Offsets etc., G.I. brackets with pvc coated GI clamps, nuts & bolts, anchor fasteners, grip bolts, GI threaded, rods, etc., complete for external pipes. (For under ground or above ground external water supply piping.) Vertical & External including landscape
69920mm dia
70050mm dia
70165mm dia
70280mm dia
703Supplying, laying, jointing, testing & commissioning approved make class "B" G.I. pipes and fittings confirming to IS 1239 PI & II, malleable fittings viz., tees, elbows, flanges, unions etc.,including cutting threading, etc., as per drawings. The quoted rate shall include necessary making bores in walls,etc., a coat of including Painting. (Pumproom)
70450mm dia
70565mm dia
70680mm dia
707100mm dia
708Providing and fixing gun metal gate valve with C.I. wheel of approved quality
70920mm dia
71025mm dia
71132mm dia
71240mm dia
71350mm dia
71465mm dia
715Providing and fixing CI D/F Sluice valve with cap / wheel as perIS 14846/2000 PN 1.0 with ISI Marking
71665mm dia
71780mm dia
718100mm dia
719Providing and fixingGM Non return valve as per IS BS 5154 and related IS Specifications
72050mm dia
72165mm dia
72280mm dia
723100mm dia
724Providing and fixing of of approved make automatic air release valve 20mm dia to release air lock in pipes as directed by EC/Client.
725Providing and fixing of approved make 50mm dia, Brass float valve, complete brass body contruction, PN6 rating, with SS ball. The scope of work includes terminating the OHT inlet pipe and positioning for smooth operation.
726Supplying, installing, testing and commissioning approved make electrically operated 50mm dia solenoid valve with level controllersto be fixed in the OHT. The cost of valve shall also include necessary level switches, wiring upto control panel at terrace level, control panel, etc.,complete
727Providing and fixing GI. puddle flanges (IS 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.
72825mm dia
72940mm dia
73050mm dia
73165mm dia
73280mm dia
733100mm dia
734150mm dia
735200mm dia
736Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers
737Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B
738PUMPS & WATER TREATMENT PLANT
739Supply and delivery of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing , hydraulically and dynamicallybalanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively.Treated Water Pump (From Domestic Water Sump to O.H.T)Duty of Pump :250 lpm x35m head(1 No. Working+ 1 No. Stand By)
740Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 % Pumproom drain pump Duty of Pump :15lpm x 40m head (1 No. Working )
741Supplying, Installing, testing & commissioning approved make variable Hydropneumatic system comprising of Vertical Centrifugal pumps mounted on a common skid with automatic control panel including overload relays, on-off push button switches, phase indicator lamps, dry run protection relays, pressure switches & guages, 1no. FRP pressure vessel of 425Lts. mounted on the pump complete with cabling between the Pumps, control paneletc., complete. The pumps shall run on 440V, 3ph, 50Hz electric supply. (For flushing & landscaping watersupply system) Duty of Pump : 67 lpm @ 45.0m Head Each Pump capacity 67 lpm - 2 pump system (1Working+1 Stand By)
742Supply,Installation & Commissioning of rain water monobloc type pump of adequate HP capable of giving required discharge at suitable head to work on3 phase 50Hz 400/400 Vwith necessary unions, flanges, foundations bolts etc., complete with head conditions. Qty : 2 nos (1W+1S)
743WATER TREATMENT PLANT 14.50 KLD (Capacity 2500 LPH)IN PUMPROOM
744Supplying, Installing, testing & commissioning approved make water treatment plant2500LPH comprising of below unitsFilter Feed Pump1 no. -Horizontal Monobloc centrifugal pump Capacity: 2500LPH Head 25m Make: Kirloskar/EQ Pressure Sand Filter 1 no.-Size: 12”x52” MOC: FRP with 25 NBMultiport valve Filtering media : Pebbles, Sand Operating Pressure : 3 Kg/Cm2 Make : Pentair/Aventura Hypo Dosing tank 1 no.- Capacity: 50 Ltr. MOC: HDPE Make: Cantax / EQ Hypo Dosing Pumps 1 no. - Capacity: 0-4 LPH Make: Veritose/EQ Activated Carbon filter 1 no. - Size: 12”x 52”MOC: FRP with 25 NBMultiport valve Filtering media : Pebbles, Carbon Operating Pressure : 3 Kg/Cm2 Make : Pentair/Aventura Softenerfilter 1 no. - Size: 16”x 65” MOC: FRP with 25 NBMultiport valve, Filtering media : Resin OBR once in 8 hrs Operating Pressure : 3 Kg/Cm2 Make : Pentair/Aventura Regeneration tank 1 no. - Capacity : 50 ltr Make : Cantex UPVC Pipes and Fittings As per requirement Make : Astral/Price/Supreme Starter ,Cable, and Accessories -As per requirement
745RO WATER TREATMENT CAPACITY 250 LPH(1,000 LTS. STORAGE)AT TERRACE
746Supplying, installing, testing and commissioning approved make RO UNITof250 LPH comprising of below unitsThe quoted rate shall also include necessary RO filter membranes, valves, pipes, electricals etc., complete to make the operation automatic.ROFeed Pump. 1no.working -Type : Horizontal Monobloc centrifugal pump Capacity:1.5 m3/hr Head 30m Make: Kirloskar/EQ Dual Media Filter1 no. Size : 10 “ x 54” MOC : FRP Make : Pentair/EQ With Media and multiport valve Micron Filter with housing - 2 nos. Size: 20"" Housing MOC : PP Make: Gopani/EQ Antiscalant Dosing System - 1 no. Pump Capacity: 0-4LPH Make: Veritose/Eq Dosing tank : 50 L, MOC: LDPEMake: Cantax / EQ SMBS & AcidDosing System Pump - 1 no.Capacity: 0-6 LPH Make: Veritose /EQ dosing tank : 50 L, MOC: HDPE Make: Cantax / EQ High Pressure Pump - 1 No. Capacity: 1m3/hr Head : 120m Type : Vertical inline multistageMake: CRI/EQ Reverse Osmosis Membrane - 1 Lot Size: 8” x 40” Make: Hydranautics /Toray /EQ Membrane housing - 1 LotPressure rating – 300 PSI, MOC : FRP, Make: UKL/Equ CIP Pumpwith tank - 1 No. Chemical Cleaning pump, 2.0m3/hr @ 25m head, CIP Tank 100 Liters, Power: 0.5 HP, MOC:SS, Make: CRI/Kirloskar RO skid –MS Epoxy painted - 1 No.MS Powder coated UPVC Pipes and Fittings - 1 Lot As per requirement Make : Astral/Price/Supreme Float switch - 1 Lot As per requirement Make : UKL/Aster/EQ Rotometer - 2 nos.Acrylic type Make : UKL/Aster/EQ Pressure switch - 1 LotLow and high pressure switch Make : Danfoss/EQ RV control panel- 1 Lot Make : RV Associates / EQ Pressure gauge- 1 Lot Make : H guru/EQ Electrical Cabling- 1 phase - 1 Lot Type : Flexible cable No. of Cores : 3 CoreMOC : Copper Multi coreMake : Poly cab / EQ Electrical Cabling- 3 phase- 1 Lot Type : Flexible cable No. of Cores : 4 Core MOC : Copper Multi core Make : Poly cab / EQ
747STP ELECTRO-MECHANICAL EQUIPMENTS (Capacity 12 KLD - MBBR TYPE) ParametersQuality of Raw Sewage in Mg/lCOD = 600 SS = 300 BOD = 400pH - 6 to 8,Treated Water standard achieved by the STP process in Mg/lCOD = 150 SS = 20 BOD = 20 pH - 6.5 to 8,Raw Sewage Source - STPSupplying, installing, testing and commissioning of Bar screen- 1 no. Type: Manual type MOC: SS 304, Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersiblepump MOC: CI Make: Kirloskar/CG/EQ Power: 1.0 HP Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersiblepump MOC: CI Make: Kirloskar/CG/EQ Power: 1.0 HP Aeration tank - 1 no. Volume: 6000 Liters MOC: FRP.Settling cum Intermediate Tank - 1 no. Volume: 3400 Liters MOC: FRP Settling cum Intermediate Tank - 1 no. Volume: 3400 Liters MOC: FRPSludge Recirculation Pumps - 1 no. Type: Self Priming pump Power: 0.5 HPMake: Kirloskar/EQ Air Blower with motor - 2nos. ( 1 working + 1 stand by)Air flow:30 m3/hrMake: Airvak/EQDiffuser - Coarse 1 Lot Type: Disc Air flow: 6 m3/hr (80mm dia) MOC: EPDM Diffuser – Fine for Aeration tank – 1 LotType: Fine Bubbl, Air flow: 6 m3/hr (63mmx610mm), MOC: EPDM, Make: Proflex/EQ Chlorine Dosing Pumps - 2nos. ( 1 working + 1 stand by)Capacity : 0-4 LPH @4 Kg/cm2, MOC: PP, Make: Edose/EQ Dosing Tank - 1 no. Capacity:50Ltrs,MOC:LDPE Filter Feed Pumps- 2nos. ( 1 working + 1 stand by)Type:
748Monobloc pump Power: 1.0 HP Make: Kirloskar/ EQ Pressure sand filter with sand media- 1 no Model No.: 12 x 54, MOC: FRP with media and MPV,Make: Fibro Tech /Pentair/EQ Diffuser – Fine for Aeration tank – 1 LotType: Fine Bubbl, Air flow: 6 m3/hr (63mmx610mm), MOC: EPDM, Make: Proflex/EQ Activated carbon filter with media- 1 no Model No.: 12 x 54 MOC: FRP with media and MPV Make: Fibro Tech /Pentair/EQ Bacterial bio culture 1 Lot[patented] Bio balls [Patented]- 1 Lot MOC: PP MS Structure 1 LotMake: Shank/EQ Air Piping1 LotMOC: MS Make: Jindal Pipes / Tata/EQ Pipes & fittings - 1 Lot MOC: UPVC Make: Finolex / Astral/EQ Valves & Accessories- 1 Lot Make: Orbit/EQ Launder for settling tank 1 No. MOC : FRP Parallel plate[Patented]1 LotMOC : PVC Electromagnetic flow meter 2 Nos.Make : Aster /EQ at STP inlet & outlet
749FIRE FIGHTING WORKS
750Supply, erection, testing and commissioning of Fire Fighting Application Horizontal Centrifugal Type Pump rated for 2280 LPM at 70 metres head with Electrical Motor of 60HP of 415 volt, 3 phase connection complete with base plate and accessories. (Make Kirloskar or Equivalent). The rate inclusive of neessary vibration, bed mounting, etc., as per standard specifications and as directed by the Departmental Officers(Sprinkler & Hydrant Pump )
751Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings complete in all respects as required. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 2280LPM against a total head of 70 metres, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant /utlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring, etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete.Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dynamo, solenoid switches etc.110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre filter, after filter etc..Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition.
752Dash board consisting of the instruments like Temperature Gauge, Galvano Type DC Ammeter, Lubricant Oil Pressure Gauge, Ignition Switch, Emergency Stop and all other protection equipments as per specification, stop soleneid for auto stop in the event of fault with audio indications, painted with Post Office Red Colour etc., as required.12 V / 24 V, storage battery, maintenance free tape, 180AH rating. MS fabricated common base plate, coupling guard, foundation bolts, etc., as required. Positioning the Diesel Engine Driven Fire Pump over cement concrete foundation using suitable size anti vibration mounting arrangements. All works including conveying, fixing and incidental charges, etc., completed as per standard specification and as directed by the Departmental Officers. (Make: KIRLOSKAR / EQUIVALENT).Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings complete in all respects as required.
753Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIRLOSKAR / EQUIVALENT. Jockey Pump
754Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
755Supplying, installation, testing and commissioning of Fire Fighting Electrical Control Panel of cubical construction, floor mounted type fabricated using CRCA sheet, compartmentalised with hinged lockable door dustand vermin proof, cable alley, inter connection having switch gears and accessories mounting and internal wiring, earth terminals, numberings, necessary metering protections and indications complete in all respect suitable for operation on 415volt, 3 phase, 50 Hz AC supply with enclosure protection class IP 54 and mounted with the followings. A. Common Panel in Fire Pump House (i). Incomer a. 1 No. 600A TP & N SDFU with HRC fuses b. 1 set of 600A, 4 bar aluminium bus bar, 415 V, 50 HZ AC supply c. 1 No. (0-500A) digital ammeter with selector switch & CTs d. 1 No. (0-500V) digital voltmeter with selector switch and control fuses e. 3 Nos. phase indication lamp LED type with toggle switches with control fuses
756(ii). Outgoing a. Main Fire Pump 400 A TPN SDFU with HRC fuses with sutable HP fully automatic starter / delta starter with over load protection, digital ammeter with built-in selector switch and suitable CTs, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation, selector switch for auto / manual / OFF operation b. Jockey Pump 125 A TPN SDFU with HRC fuses with suitable HP fully automatic starter / delta starter with over load protection, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation, selector switch for auto / manual operation - 1 No. c. Diesel Engine Control comprising of: 1. Auto / manual selector switch and 3 attempt starting device, timers and relays as required, push buttons, start /stop in manual mode. 2. Indication lamp for high / low lubricant oil pressure, high water temperature and engine ON indication. 3. Battery charger suitable for 12V /24V DC with boost and tickle selector switch, 0-15V / 0-30V DC volt meter, 0-20A DC ammeter.
7574. All standard relays and accessories for automatic operation of diesel engine. 5. The above combined panel mounted over MS channel fabricated frame with cement concrete platform, all other connection works carried out as per standard methods and including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. Note: Cables, Earthpit Quantity for Pumproom considered in electrical BOQ
758Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: H-GURU / ISI MAKE / EQUIVALENT.
759Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. Make: DONFOSS / INDFOSS / ISI MAKE / EQUIVALENT. (TN SOR 2021-2022 Sl. No. 363 Page no.89)
760Supply, erection, testing and commissioning of following MS Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.
761250mm dia
762200mm dia
763150mm dia
764100mm dia
76580mm dia
76665mm dia
76750mm dia
76840mm dia
76925mm dia
770Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anticorrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.
771150mm dia
772100mm dia
77380mm dia
774Supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT
775250mm dia
776200mm dia
777150mm dia
778100mm dia
77980mm dia
78065mm dia
781Supply, erection, testing and commissioning of Gun Metal Gate Valve of size 50mm dia size including necessary MS flange of table gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / EQUIVALENT.
78250mm dia
783Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
78425mm dia
785Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
786200mm dia
787150mm dia
78865mm dia
789Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
790250mm dia
791Supply, erection, testing and commissioning of AirRelease Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR /EQUIVALENT.
79220mm dia
793Providing, fixing pipe supports from columns / wall or suspenders from roof slab to suit various dia of pipes made out of GI / MS adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening, arrangement design of hanger and should confirm with specification.
794100mm dia
79580mm dia
79650mm dia
79740mm dia
798Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD /EQUIVALENT.
799Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
800Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT.
801Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonaltype spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
802Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
803Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
804Supply and fixing in position of Fire Fighting Duct Window having proper glass window type double door with universe open key, painted inside white and outsid post office red for the sizes of 1300 x 900 x 500mm (L x B x D) fabricated using 25 x 3mm MS "L" Angle and all sides covered with 2mm thick MS sheets, suitable arrangements to kept 2 Nos. of Fire Fighting Hoses and 1 No. Branch Pipe, mounted in fire duct using anchor fasteners, etc., as per standard specifications and as per directed by the Departmental Officers.
805Supplying, installing, testing and commissioning flow switch on sprinkler distribution header and shall be connected to fire alarm panel through cable. Cable shall be measured separately. (150mm dia/100mm dia)as per IS standards
806Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, testcontrol box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of 150mm dia.
807Sprinkler Annunciator Panel shall consist of 12 windows.The panel shall be capable of working on 230 V AC, single phase supply and also provided with battery back up of 24 V.The panel shall have battery charger in built so that it charges the batteries when it works on AC supply.The charger shall be two rate type i.e Trickle and boost.The panel shall be fabricated powder coated sheet metal of at least 16 Gauge thickness.The panel also shall have selector switches, Indication lamp, ON, OFF and trip switches etc.Adequate cable entry point shall be provided in the panel for accommodating the cables.Whenever any annunciation signal is received panel shall give both audible / visual indication.Accept button shall be provided so that whenever signal is accepted, only audio sinal will get silenced.Each window shall be connected to the relay contacts with RS 485 for connecting the same to the building automation system. The Annunciation Panel shall have annunciation for all pumps “ON” and “TRIP” conditions and “Fire water Tanks High / Low level / Overflow conditions and “Operations of Control valves”.It shall have test, acknowledge and reset push buttons.The panel shall operate on DC supply.
808Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFEGUARD / EQUIVALENT.
809Supply, Installing, testing and commissioning of Stainless Steel Corrugated Flexible Braided Pipe(Hose) for dropping sprinklers below false ceiling.Pipe shall be 16 bar pressure rating and 1500mm long, 25mm dia with union / reducer, collar, clamps, etc. It shall have UL listed and FM approved.
810Supplying and installing of approved type RosettePlates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Departmental Officers.
811Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIARTAR / OMEX / EQUIVALENT.
812Supply, erection, testing and commissioning of Fire Fighting 2 Way Fire Brigade Inlet with necessary gun metal 63mm dia non-return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. (Make: KIARTAR / OMEX / EQUIVALENT)
813FIRE EXTINGUISHER
814Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
815Supply and fixing of DCP (Dry Chemical Powder ) Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers.
816Supply and fixing of Carbon-di-Oxide Gas Type 4.5 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers.
817Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
818Supply and fixing of Aqueous film forming foam 9lts. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers.
819Supply and kept in position of Trolley Mounted Type 22.5 kg. Carbon-di-Oxide Fire Extinguisher as per IS15683, complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, mounting trolley with moving wheel, safety clip, etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST /EQUIVALENT
820Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers
821SIGNAGES
822Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners.
823Signage with printed"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.
824Floor indentification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.
825Providing and fixing in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3" x 4".ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION . EVACUATE THE OCCUPANTS BY USING THE FIRE EXITS & EMERGENCY EXITS ONLY. ASSEMBLE AT VARIOUS ASSEMBLY POINTS. IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING THE NEAREST/SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER BE CALM, DO NOT GIVE ANY ROOM FOR PANIC, WALK, DO NOT RUN IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, STAY IN YOUR PLAN AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM
826Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fastenersACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS:C) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER…….. FIRE FIGHTING AGNECY-------------------------------PHONE : ----------------------- FAX : ----------------------------
827Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,)
828Providing and installing of Fire Evacuation Plan with route inrectangular Acrylic sheet with ss bolt of size 600 x 450mm& 2 to 3mm thick
829FIRE ALARM & PA SYSTEM
830Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel.
831Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector (smoke detector) complete with mounting base complete as required.
832Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
833Supplying, installation, testing & commissioning of fault isolator complete with base as required.
834Supplying, installation, testing & commissioning of intelligent addressable thermal detector (Heat detector) with rate of rise cum fixed tempreature thermistor complete with base as required.
835Supplying, installation, testing & commissioning of addressable fire control module complete as required.
836Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. (Make: Ravel / Equivalent)
837Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent)
838Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
839Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
840Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
841Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
842Supplying, installing, testing & commissioning of 15 W Wall Mount Speaker
843Supplying, installation, testing & commissioning of PA Mixer Amplifier 240 Watts
844Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
845Supply and laying of 2 core 1.5 sq.mm.Armoured Speaker Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
846Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
847Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
848IBMS system
849MAIN BMS SERVERHARDWARE BMS Server shall comprise of the following minimum hardware: Xeon Octa Core IntelSeries Processor at mim 3 GHz 20M Cache,4GB or more of RAM, 1 Tb hard drive,DVD player- Read and write with video card and video recording application with 15 min UPS Redundant power supply unit ,Standard video display adapter Microsoft® Windowslatest 64 bit OS with AntiVirus,MS Windows Server Software and operating license; and MS SQL Server License etc
85042" colour , Flat Screen Type Professional HD monitor for above client workstation
851A 4 size Color Laser Alarm Printer suitable for the application, with driver software.
852Softwares for BMS System
853BMS Server software as specified with for realtime Processing of all Data being mapped in to the system by the DDCs and Protocol Integrators as mapped in the IO Summary. Shallbe Complete with Web Browser Module for Remote Login, to be able to transmit user defined data in Graphical Format. Shall interface with Access Control / CCTV System by virtue of either a unified database, or by the use of Middleware to achieve a 2 way interface between the systems. With Unlimited point licencesinclusive of tenant billing software
854Client version BMS software for "Monitor & Control" application, complete with Advance Graphics for Realtime Graphical Depiction of the Statuses and Controls as per the Detailed IO Summary .
855SMS & E-mail alarm notification module with unlimited user capability,SMS Paging& Email Facility for transmitting specified alarms to designated personnel.
856GPRS / GSM Modem of 4G Modem
857Internet Router Which can support upto 100MBPS Speed
858Supply,Installation,Testing & commissioning of Serial interface Modules (as a part of IO Module train) for High Level integration with following 3rd Party Equipment"s as mentioned in the data point summary.The system will warrant an Exclusive, Dedicated Serial Interface card for every single individual 3rd party system (No other 3rd Party Integration shall be clubbed with any one integration ) The Interface card shall be Capable to Integrate Open protocol systems on BACnet /Modbus/LONWORKS/M-Bus/J-Bus Protocol Made available on serial RS 485 / 232 interface. Such Interface cards shall be part of the IO Train and shall Be Installed the same enclosureswhere the Other IO Hardwired Modules are installed ,
859Serial Interface card for Energy Meter/Load Manager - 98 nos
860Serial Interface card for Variable Frequency Drives - 11 nos
861Serial Interface card for Diesel Generator - 1
862Serial Interface card for UPS -2
863Serial Interface card for CSU -24
864Serial Interface card forAHU-8
865Serial Interface card for VRF-11
866Serial Interface card for STP -1
867Serial Interface card for lifts
868Serial Interface card for FAS-1
869SITC of Enclosures ( Complte with DDC controllers, IO Modules, Serial Integrator Module) as per Data point summary The Enclosures shall be MS Powder Coated , IP 55 Rating for indoor; and IP 65 rating for outdoor Installations. The Enclosure shallbe provided with mounting accessories for DDCs / and or IO Modules and Serial Modules- suchas DIN Rails, Elmex Terminals for Cable Terminations, Cable Managers, Dressings for internal cabling, ferruling, tagging etc. PSU shall also cater to power requirmeent of the Instrumentation, Actuators and other connected equipment. Enclosure Shall be Complete with pilot relays, fuses, overload protection relays, auxiliary power output socket etc. as required to complete the installation and intended usage. Shall have Top and Bottom Knockouts for Cable entry, and side vents for ventilationDDCs, I O Modules and Serial Modules shall confirm to Tender specs and design intent.Each DDC shall not exceed more than 40 IO ponits including spare, In a DDC Enclosure, there shall not be more than 6 controllers/expansion modules. The Enclousere shall be provided with UPS as per enclousere power Requiremnet
870FOR CSU
871For AHU
872For Fresh air fan
873For water tank and sump
874Instrumentation controls and valves with + 2% Accuracy (For Temperature Sensor the Accuracy shall be +/- 0.5 deg C) ; Complete with required fitting and mounting accessories, Copper tubing"s, PVC tubing"s, terminations, Ferruling, Tagging, Lugs et al, provided to ensure technically acceptable installation
875Outdoor Air Temperature & RH sensor
876Air Differential Pressure Switch
877Duct Type Temperature & Humidity Sensor
878Level Sensor for Water Tanks
879Dust Static Pressure Sensor
880Space Type CO2Sensor
881Cabling and Containment
882Cabling for instrument, controls, valves to DDCs and communication cabling from DDC to central equipment complete with earthing, supports etc complete. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends.
8832 Core x 1 sq mm FRLS Al-Mylar Screened with drain wire, Cable for control cabling
8844 Core x 1 sq mm FRLS Al-Mylar Screened with drain wire, Cable for control cabling
885Communication cable: FRLS Communication Cable Cat 6e as per IEEE Standards / Communication Cable 2 Twisted pair x 1.0 mm2 Multistranded Screened Communication cable with Al Mylar Tape and 0.5 mm2 Drain wire as per requirment by System.
88625mm MS Conduits B class with Saddle & Spacers, flexible GI extensions, back boxes and gang boxes, junction boxes with elemex terminals etc., complete as required to fulfill the desired objective of cabling
887Perforated GI cable tray with Cover : complete with supports, all fittings and mounting accessories,etc complete to installation requirements.
888300 mm x 50 mm x 2 mm
889SITC of Edge Switch : 24 port layer 2 switch with 10/100/1000 Managed Switches withIP multicast snooping and data-driven IGMP support and with Two 1000baseT single mode FO uplink ports (with Fiber Module ) and all related termination accessories as per site specific System requirement. Compliance to Tender specs to be Provided
890SITC of Core / Aggregator Switch : Modular 24 port Layer 3 managed switch withFiber ports; required number of 10/100/1000 ports etc. as per project requirement. Compliance to Tender specs To be provided
891Equipment Racks
89219" type Equipment racks for mounting the Servers/ Switches in the BMS Equipment Room, & for mounting field mounted Switches at every Floor. Racks shall be complete with Modular Patch Panels for Patching the Field Cables ( Cu and FO) with the Edge Switches on floor as required. Racks shall be provided with Dual Power A&B, and should have 2 PDU Strips, Redundant Fans and Door to have Tamper Switch.
89342U
89419", 24 U Modulat Patch panel /LIU Bidder to Size the Equipment as per Project IO Requirements
895Any other accessories required to complete the system configuration as per vendor specific requirements i.e. Power supplies,fiber converters, LIUs, Specific System cables etc. to complete the installation. Contractot to mention the quanity of the below items with costapart from the below item if any other acceroiers are required , controator to add the same Patch Panels,1mtrs Cat6 Patch Cords ,LIU’s Pigtail cables, 1mtr LC to LC Single Mode Patch Cords,1mtr LC to LC Single Mode Patch Cords, Labels any Other componentto complete the design intent
896ACCESS CONTROL SYSTEM
897Readers and Controllers
898Supply, installation, testing & commissioning of Smart card readers as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories
899Supply, installation, testing and commissioning of Biometric - cum -Pinpad cum Proximity Reader with 3000 Users (Templates on Reader) - 2 Templates each User with Membrane Sensor for Live Finger Verification.
900Supply, installation, testing and commissioning of electromagnetic Lock (fail safe type) of 600lb holding force, with built-in Door Feedback & door ajar alarm buzzer for the following type doors :
901Single leaf Door- 600LB
902SITC of Recessed Magnetic Door Contactfor Doors with mounting accessories to complete the installation in all respects.
903Supply , installation, testing and commissioning of Push Button for Exit
904Supply installation, testing, commissioning of Green ABS plastic Emergency Break Glass Units.
905Supply installation, testing, commissioning of Weather Proof Green ABS plastic Emergency Break Glass Units.
906Supply, installation, testing and commissioning ofTwo Reader Control panel housed in MS Powder Coated Cabinet with Tamper Switch, complete with On-board IP / LAN port, and Built-in Web Server for Remote Log in to every controller. Also the Controller should have spare potential free contact to trip any third part system if required.
907Complete with power supply unitfor Controllers & Magnetic Locks
908Supply, installation, testing and commissioning ofFour Reader Control panel housed in MS Powder Coated Cabinet with Tamper Switch, complete with On-board IP / LAN port, and Built-in Web Server for Remote Log in to every controller. Also the Controller should have spare potential free contact to trip any third part system if required.
909Supply, installation, testing and commissioning of Blank Unprinted Smart cards as per specification.
910SITC of Client PC for Access Management :
911AccessServer shall comprise of the following minimum hardware: Xeon Octa Core IntelSeries Processor at mim 3 GHz 20M Cache,4GB or more of RAM, 1 Tb hard drive,DVD player- Read and write with video card and video recording application with 15 min UPS Redundant power supply unit ,Standard video display adapter Microsoft® Windowslatest 64 bit OS with AntiVirus,MS Windows Server Software and operating license; and MS SQL Server License etc
912Access ControlSoftware
913Client Version Application Software for Access Control :- (Location :BMS Room). Shall be Capable of Generating Multiple Reports in Excel format , such as Department wise / Door Wise/ Card Wise / Day wise / Weekly, monthly reports etc.
914Pedestrian & Vehicle Traffic Management
915Supply, Installation, Testing and Commissioning of 3 Set Speedflap barrierin SS Finish, with SS long housing, Servo position Drive with tooth holding break technology, 1800 mm Glass , sensor should be hidden not visible and shall be in specific pattern , detection shall be in algorithm based and with all mounting accessories. Capable of Free Egress in case of Fire Alarm / Emergency Event and Automatic Reset after resuming of Normal signal or Power. Mean Cycle Between Failure shall be minimum 12 Million Shall have Access reader on both sides for Bi-directional Access.
916Supply,Installation,Testing & commissioning of Handicapped Swing Gate Barrier, SS Finish with Toughen Glass/ Polycarbonate showing Universal Handicap Insignia. Capable of Free Egress in case of Fire Alarm / Emergency Event and Automatic Reset after resuming of Normal signal or Power. Mean Cycle Between Failure shall be minimum 12.0 Million Shall have Access reader on both sides for Bi-directional Access.
917Articulated Boom Barrier - 4.5 mtr long Electromechanical type maintenance free Boom Barrier ,Boom made of 2mm zinc coated sheet Steel Powder coated & base of SS with reflective tape strips, with opening time less than 3 sec`s,complete with fixed support post,IP 65 Protection. It shall also include Control Panel and remotely placed manual override switch. Complete with 2 pairs ofPhotocell safe beam with Mounting Frames & SS Stand posts as required to complete the installation.FRLS AB Copper Armoured Cable,PVC insulated, shielded PVC Sheathed layed with fittings & G.I Supports at 0.3mtr
9188 c x 0.75 Sq.mm
9194c x 0.75 Sq.mm
9202c x 1.0 Sq.mm
921IP BASED CCTV SYSTEM
922Supply, Installation,Testing Commissioning of IP Based CCTV System comprising of following: -
923IP Cameras : Indoor/Outdoor surface mount enclosure, Mounted on True Ceiling / False ceilingas per site requirement (including required accessories), UL Listed as per detailed specifications.
924Indoor Dome Camera, Wide Angle IP dome, POE ,1/3" CMOS, Min. 5 MP Resolution, Dual H.264 / H.265 Streaming, 25 fps, fixed lens 2.6/2.8/3/3.6mm, 0.5 lux for colour, Tamper detection, 3D Noise reduction, Auto Gain / Auto White Balance. PoE With LATEST ONVIF Compliance IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 )
925Indoor IP Bullet Type Camera IP Bullet Camera, POE, Outdoor Weatherproof, Min 5 MP , 1/3 CMOS, IR Cut lens , IR for 15 meters, POE ,Vandal / Tamper proof, Optical WDR > 60 Db ,Auto Gain / Auto White Balance. IP 66 & Vandal proof enclosure , 3D Noise reduction, PoE & standard 12VDC/24VAC power input . IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 )
926Outdoor IP Bullet Type Camera ( Periphery walls / Building external walls) IP Bullet Camera, POE, Outdoor Weatherproof, Min 5MP , 1/3 CMOS, IR Cut lens , IR for 25 meters, POE ,Vandal / Tamper proof, Optical WDR > 100 Db ,Auto Gain / Auto White Balance. IP 66 & Vandal proof enclosure , 3D Noise reduction, PoE & standard 12VDC/24VAC power input . IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 )
927SITC of Outdoor Application Low Light IP Hi speed Dome type PTZ camera with 2 MP Resolution, mim 32X optical zoom, Low Light ,Day/Night, Wide dynamic range > 100 dB, Dual H.264 streaming, 0.05 lux, vandal resistant, 360° continuous pan, -0° to +90° tilt, 256 preset, IP66 rated with built in heater and blower, Mounted on Wall/Pole as per site requirement (including required accessories), UL listed as per detailed specifications. IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 )
928SITC of 16 channel High resolution (720x576) Video and Audio encoder with Dual streaming with 25FPS & highest resolution, Dual H.264 streaming support, PoE, RS232/485 connection as per detailed specifications.
929SITC of 8 channel High resolution (720x576) Video and Audio encoder with Dual streaming with 25FPS & highest resolution, Dual H.264 streaming support, PoE, RS232/485 connection as per detailed specifications. (For lift & PTZ cameras)
930SITC of GI Pole, 100mm dia, 5m high with 2 coats of reoxide primer and 3 coats of external weatherresistant colour as per Architects recommendation, complete with mounting accessories as required for the pole as well as the cameras, suitable to mount the outdoorcameras to the directions of the consultant.
93110 Tb hard diskindustry tye
932Servers , Networking Hardware & Softwares : -
933SITC of Client PC Hardware with a minimum specification of Intel i7 Quad Core Processor 7th Generation at mim 3.6 GHz ,12M, Intel HD Graphic 630, 6.4GT/s, 4x4 GB or more of RAM, 500GB SATA,10K RPM 3.0Gb/s Hard Drive for OS and VMS Applications Network Interface Card - 10/100/1000 MB Network Fiber Interface Card - 4 x 1Gbps in fault tolerance configuration Video Card – nVidia 2 x NVS295 Quad Monitor Graphics card to support 4 multiplexed Monitors Motherboard should support Intel as well nVidia GPU in active-active mode and both devices should be enabled. DVD-R/W Microsoft® Windows® 8.1 / 10 Pro or Higher 64 bit
93421" colour ,Flat Screen type Professional CCTV Surveillance HD monitor for above client workstation
93555" colour , Flat Screen Type Professional CCTV Surveillance HD monitor for above client workstation
936SITC of Video Analytics Processing Software & Hardware :- - 20 Nos TO Support Minimum 1 cameras, programmed with any 1 or more, of the following of the following Video Analytics features : a) Object left behind, b) Directional Motion ( Adaptive Motion), c) Object Removal d) Camera Sabotage e) Loitering e) Crowd Detection f) Trip Wire g) Object Counting h) Vibration Removal (The System shall allowimplementation of Video Analytics on any user defined cameras during commissioning). Independent servers, if required to be used for video analytics shall be included in this item as required.
937Independent LAN for IP CCTV Camera System :-
938SITC of Edge Switch : 24 port layer 2 switch with 10/100/1000 POE Managed Switches withIP multicast snooping and data-driven IGMP support and with Two 1000baseT single mode FO uplink ports (with Fibre Module ) and all related termination accessories as per site specific System requirement. Dual Powered . Compliance to Tender specs to be Provided
939SITC of Edge Switch : 16 port layer 2 switch with 10/100/1000 POE Managed Switches withIP multicast snooping and data-driven IGMP support and with two 1000baseT single mode FO uplink ports (with Fibre Module ) and all related termination accessories as per site specific System requirement. Dual Powered . Compliance to Tender specs To be provided
940SITC of Core / Aggregator Switch : Modular 24 port Layer 3 managed switch withFibre ports; required number of 10/100 ports etc. as per project requirement. Dual Powered . Compliance to Tender specs To be provided
941Cables
942Cable/Conduits shall be laid on surface with GI saddle & spacers every 0.3 meters. Complete with GI Junction Box, LIUs/ Pigtails , Patch cord /Patch Panels etc ,Splicing , lugs, cable compression glands, cable tags and Ferruling. The Structure cabling Scan test shall be Done and inspected by OEM and report for the same shall be provided by OEM
943SITC of Supply & Laying of Armoured FRLS Cat-6(LHZH) cable laid in Conduits / cable Trays. Shall be complete with IO Module Boxes at the Camera End, Patch Cords, GI Gang Boxes, Termination lugs, Labelling and tagging, ferruling etc
944Single mode 2 core Fibre optic cable, Zero Halogen Low Smoke outer Sheath. laid in Conduits / cable Trays. Shall be complete with IO Module Boxes at the Camera End, Patch Cords, GI Gang Boxes, LIUs, Pigtails, Termination lugs, Labelling and tagging, ferruling etc ( switch to switch and wherever 120 mts exceeds)
945Media converter for OFC- Rj45
946Any other accessories required to complete the system configuration as per vendor specific requirements i.e. Power supplies, fiber converters, LIUs, Specific System cables etc. to complete the installation. Contractor to mention the quantity of the below items with costapart from the below item if any other accessoriesare required , controator to add the same Patch Panels,1mtrs Cat6 Patch Cords,LIU’s,Pigtail cables,1mtr LC to LC Single Mode Patch Cords,Labels,any Other componentto complete the design intent
947Supply, erection , testing and Commissioning of Machine Room Less Liftof 20 Person capacity having 8 Stops for G + 4 Floor of 4 M travel distance between floorsin LIFT Well size of 2175 X 2525 mm including Floor level indicators in each floor, False ceiling with Light, Mirror and wall finish ofSS Grade 304Brushed finish, Brushed SS Handrail for rear wall , Door having SS Brush finish , Car Floor , call indicators in each floorsetc ;.
948Supply, erection , testing and Commissioning of Machine Room Less Liftof 16 Person capacity having 8 Stops for G + 4 Floor of 4 M travel distance between floorsin LIFT Well size of 2175 X 2375 mm including Floor level indicators in each floor, False ceiling with Light, Mirror and wall finish ofSS Grade 304Brushed finish, Brushed SS Handrail for rear wall , Door having SS Brush finish etc ;.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail