| 1 | DISMANTLING WORKS |
| 2 | Unless specified, no extra paymentshall be made for removing, plaster, tiles, all kinds of floor finish etc. attached to brickwork & RCC work & RCC grade slab in floor. |
| 3 | All serviceable & unserviceable materials are separated & stacked separately. |
| 4 | Dismantled bricks / rubbles shall be stackedproperly within a lead of 200m. |
| 5 | All works are inclusive of scaffolding at any height of any floor. |
| 6 | Breaking, demolishing & removing existing Brick work, RCC work, PCC work, MS structural works like trusses, purlin, column, flooring etc. including scaffolding, supporting existing structure with props and removing the debris including useable /salable or scrap material at the factory scrap yard within factory premises or within a lead of 200 meter (if specified)with carting and properly stacking/ segregating as per type of scrap/material as directed by Site engineer/ Company personnel. (Existing shed to be demolished, Kindly Quote rate after Site visit as per actual work) |
| 7 | Breaking RCC work column, beam, slab, staircase, lintel, floor, paradi, foundation including reinforcement etc including plaster, painting, inserts, nosing angels, fasteners etc.All dismentaled material shifted up to 50 to 200 metre where as directed |
| 8 | Removing rubble soling |
| 9 | Breaking of Plain cement concrete (PCC) |
| 10 | Breaking Brick/Block masonry, Siporex block masonry of any size/ thickness including plaster, Glazed tiles, skirting, painting, electrical conduits etc.All dismentaled material shifted up to 50 to 200 metre where as directed |
| 11 | Removing of existing doors, windows, ventilators, partitions, grills of any type of material. All dismentaled material shifted up to 50 to 200 metre where as directed |
| 12 | Removal any type of plaster like sandface ,neeru single coat ,double coat including scafolding,with required tools etc complete.All dismentaled material shifted up to 50 to 200 metre where as directed |
| 13 | Cutting of MS reinforcement steel bars with gas cutting machine as per instructions of Engineer In Charge. |
| 14 | Up to 16 mm dia |
| 15 | Above 16 mm dia |
| 16 | Dismentaling of MS structural works like trusses, purlin, column, frames for louvers, bracing, ladders, cage ladders, sag rods, cable racks, pipe bridges, monorail, walk ways, chequered plates, grating along with all accessories viz nuts, bolts, cleats, gussets, suspenders etc. All dismentaled material shifted up to 50 to 200 metre where as directed |
| 17 | Removing gently existing metal/AC/precoated sheets from roofing, cladding, louvers etc. including necessary scaffolding, rope, ladder for safety measures, stacking at the location as specifiedAll dismentaled material shifted up to 50 to 200 metre where as directed |
| 18 | Carting of debris of removed & excavated material up to 2 Km area from functional construction site as per specifiedwithout disturbing any property including loading, unloading, spreading & leveling as directed by site Engineer/ Company personnel. |
| 19 | EXCAVATION WORK |
| 20 | Rate is inclusive of all types of dewatering. |
| 21 | Excavation dimension shall be as per PCC dimension only |
| 22 | Excavation rate includes removal of all kind of vegetation, small shrubs etc. |
| 23 | Excavation for foundations, trenches, pits etc. for column footing pedastalsin all types of soils, sand gravel, clay, soft and hard murum etc, including clearing of site, removing shrubs, tree roots, rank vegetation etc & including dewatering if required as per site conditions, backfilling, ramming, wateringetcall as directed, drawings and specifications. |
| 24 | Upto 1.5m below GL |
| 25 | Soft Rock 1.5m to 3.0m below GL |
| 26 | Hard Rock 1.5m to 3.0m below GL |
| 27 | Providing and laying 230 mm average thick dry rubble stone pitching on slopes with stone of approved quality & size including laying to proper grade and slope, filling the interstices with chips and selected approved excavated earth (earth for the same purpose shall be obtained by Contractor from within Owner\"s premises at no extra cost to the Owner),compactingwith mechanical compactorcutting/ filling and dressing the existing surface up to max depth 300 mm, compacting the surface by ramming etc.complete as per Specifications and as directed and instructed by Engineer. |
| 28 | Refilling/Backfilling with approved excavated material available at site approved by site engineer/company personnel. including carting of 1km, filling to be done in layers not exceeding 500mm thick including watering, ramming, compaction by mechanical compactor etc complete as directed. |
| 29 | Providing and Filling in plinth, foundations, trenches, pits with approved material brought from outside approved by site engineer/company personnel. filling to be done in layers not exceeding 200mm thick including watering, ramming, compaction, consolidation with mechanical earth compactoretc complete as directed. |
| 30 | Carting of debris or excavated material up to 10 Km area from functional construction site as per specified location /authorised designated place with written consent of owner based on formal company gate pass procedurewith outdisturbing any property including loading ,,unloading,speading leveling as directed by site Enginner/company personal |
| 31 | ANTITERMITE TREATMENT WORK |
| 32 | Providing and applying approved make anti-termite treatment for foundation, plinth, floor, plinth protection periphery of building in width of 1.2m by treating soil/sub soil and back filling material in immediate contact with foundation, ground beam, column below plinth by spreading 0.05% emulsion concentrate with the insecticide as specified in IS 6313 (part II and III) at the rate of 5lits per Sqm including all material, labour, equipment complete, covering 10 years guarantee on stamp paper for termite resistance etc complete as directed. (Only plinth plan area will be measured for billing purpose) |
| 33 | CONCRETE WORK |
| 34 | The rates for all items covered in this section shall include cost of dewatering, |
| 35 | The rate also includes cost of providing offsets, cutouts, pockets, sleeves, inserts, hooks, construction joints, making holes/cutouts in or cutting formwork for taking out dowel bars, hacking the exposed surfaces to receive plaster as necessary. |
| 36 | Rates are applicable for all floors at all levels. |
| 37 | Rates are inclusive of all types of onsite and offsite material/concrete testing as per IS 456:2000. |
| 38 | Providing and laying plain cement concrete 1:3:6 (M 10) below all types of foundations, walls, plinth beam, flooring, plinth protection, ramp, manhole, drain pipe, water tank, road using coarse aggregate of 20 mm and down including necessary formwork at various locations, including machine mixing, laying, consolidation, finishing, curing & dewatering the pits etc all as per drawings, specifications and as directed. |
| 39 | Providing and laying in situ M35 Cement Concreteconfirming to IS-456:2000,design mix at all locationsand levels using coarse aggregate 20mm & down including, plasticizers, mechanical mixingwith weigh batcher , compactedbyvibrator, finishing, with all necessary form work, all types of curing including scaffolding, staging at all heights as per drawings, specifications etc complete as directed. Rate excluding HYSD steel. Rate to include works at all heights |
| 40 | RCC Footings, foundations, pile cap, Raft slab, |
| 41 | RCC Ground, Plinth beams |
| 42 | RCC Columns, column pedestal |
| 43 | RCC Beams |
| 44 | RCC Lintel Size less than size 230 X 230 mm (Rate not applicable for 230 x 230mm) |
| 45 | RCC Slabs |
| 46 | RCC Pardi above 100 mm thk |
| 47 | RCC Chajjas |
| 48 | RCC Staircase waist slab including tread and riser. |
| 49 | For Vault/semi circular slab at all height as per designs, drawings, specifications etc all complete as directed. |
| 50 | Providing and laying M35 cement concretefor strengthening of old structure including jacketing to the columns, bams, slabs including formwork etc. as per structural desgin given by desiner etc. complete |
| 51 | Providing and laying Microconcrete with ferrocementing for strengthening of old concreteincluding jacketing to the columns, bams, slabs including formwork etc. as per structural desine given by desiner etc. complete |
| 52 | REINFORCED STEEL WORK |
| 53 | The rates shall include for cost of supplying & fixing binding wire and concrete cover blocks of same grade of concrete. |
| 54 | Preparation of bar bending schedule & obtaining their approval from Engineer/Project in-charge is must. |
| 55 | Rates are inclusive of all types of onsite and offsite material testing as per frequency mention in IS Code. |
| 56 | Rates are inclusive of all wastages. |
| 57 | Providing, cutting, laying & fixing in position steel reinforcement (TATA Fe 500) of various diameters in all RCC work at all levels & heights including supplying, decoiling, straightening, cutting, cranking, bending and placing and fixing in position with 16 gauge annealed binding wire, good quality concrete cover block of specified size in respective drawings, including preparation of Bar Bending Schedules & obtaining their approval from Engineer/Project in-charge complete as per designs, drawings specifications and as directed complete. |
| 58 | MASONARY WORK |
| 59 | Rate inclusive of works at all levels. |
| 60 | Providing & constructing 200mm thk Ecolite Block masonryof approved quality in cement mortar 1:4 with screened sand in line, plumb and level, in superstructure at all locations, levels, floors including scaffolding, racking out the joints, 8mm dia 2nos bar at every 3 layers and curing etc complete as directed. |
| 61 | Providing and constructing 150mm thick first class brick masonry in superstructure at all levels for walls as per drawing in C.M. 1;4 with screened sand including casting R.C.C. M15 patli 100 X 75 mm at every 1m height with providing and laying in position 2Nos 8mm dia bars including soaking bricks before use, scaffolding, racking out the joints and curing etc complete as directed. |
| 62 | DOOR & WINDOW WORK |
| 63 | All aluminum sections shall be of Jindal make |
| 64 | Sample aluminum members to be approved beforeProcurement |
| 65 | ALLUMINIUM OPENABLE WINDOW |
| 66 | Providing, supplying and fixing in position single leaf Colour anodised extruded aluminium casement/openable window of outer frame made of section weight 1.326kg/mt and shutter frame made of section weight 1.1kg/mt with side hung casement window with scizer hinges, handle with locking system with 6 mm thk plain glass (Low emission) with neoprene (rubber) gasketpegstay etc. as per approved drawing, specification etc. complete. (window sizes are 1.1 x 1.5mt) |
| 67 | ALUMINUM FIXED WINDOW |
| 68 | Providing and fixing in position Colour anodised extruded aluminium fixed glass panels window having frame made out of Colour anodised extruded tubular section of size 34mm.x 42 mm (or as required size in proportionate weight) of average thickness 2 mm and weight 0.726 kg. per metre (or as required) mechanically assembled at corners with glazing, beading of average 0.26 kg. per running metre or required weight including 5.5 mm. thick selected quality plain sheet glass with neoprene (rubber) gasket etc. complete. |
| 69 | DOORS |
| 70 | Providing & fixing single leaf solid core wooden flush door 40mm thick (water proof) of approved make for shutter including all approved quality dORMA fixtures with chromium plated like Aldrop, Tadi, Tower Bolt, Door Stopper, Handle etc includingSS hinges (4 nos) all as per drawings & specifications includingas per specification Complete. |
| 71 | same as above with both side 1 mm thk laminate as specified |
| 72 | Providing and fixing in position powder coated GI Single Leaf flush door of (Shaktimet or equal)with door frame of63 mm x 50 mm in 1.5mm thk GI sheet including fixing frame in wall with 75mm long screw Screwing to be done to RCC jambs. Holes to be covered by PVC cap and Door shutters made of 0.8 mm thk GI sheet including internak framework inside shutter with internal filled with Rock Wool, with heavy duty ball bearing stainless steel hinges 125 X 38 X 3.7mm (4nos of hinges for each shutter) with 10 X 25mm SS star screw (concealed screws) ,Concelled lock with top SS rose, one door shutter will be holded by tower bolt, 1no Dorma door closer to be fixed on one shutter , SS 304 19mm dia 300 mm long D handle from both side as per detailed drg, SS kick plate in SS 304 plate 16G at door bottom 200mm ht over GI sheet fixed with adhesive, shutter with 450 x 450mm clear viewing panel with 4mm thick Modi glass. All materials will be as per specification and of approved make and as per detailed drawings and as directed by Engineer/ Owner. |
| 73 | PLASTERING WORK |
| 74 | Providing tips/thiyya on masonary prior to plaster to check plaster line & plumb is must. |
| 75 | Providing and doing 12mm thick internal cement plaster with neeru finish to ceiling and walls at all floors, locations and level in line and plumb with C.M 1:4 mix to all RCC & masonry work including grooves, bands, drip molding,including providing & fixing of chicken wire mesh of 26G thickness & 15mm square mesh size at the junctions of different type of construction material member by using nails, drilling holes if necessary and scaffolding, curing complete as directed. |
| 76 | Providing anddoing 20mm or more thick sandfaced plaster using waterproof chemical at all heights in line, level, plumb in 2 coats with base coat in CM 1:4&top coat in CM 1:3 sponging the surface to bring out sand particles prominently, making grooves, bands, drip molding, including H-frame scaffolding. The work & rate to include providing & fixing of chicken wire mesh of 26 G thickness & 15 mm mesh size at the junctions of concrete and masonry member by using nails, drilling holes if necessary including curing etc. complete as directed. |
| 77 | Providing & Applying fibre glass resin coating to top of vault slab including finishing, waterproofing tests for five days etc. complete covering a guarantee for a period of seven years. |
| 78 | Providing and doing 12mm thick Readymix plasterto ceiling and walls at all floors, locations and level in line and plumb with C.M 1:4 mix to all RCC & masonry work including grooves, bands, drip molding,including providing & fixing of chicken wire mesh of 26G thickness & 15mm square mesh size at the junctions of different type of construction material member by using nails, drilling holes if necessary and scaffolding, curing complete as directed. |
| 79 | FLOORING WORK |
| 80 | Rate is inclusive of chisseling masonary work to flush skirting tile with plastered surface. |
| 81 | Kota stone tile to be sorted out prior to flooring work to maintain same colour/shade. |
| 82 | TREAD RISERS |
| 83 | Providing and fixing 20 to 25 mm thk high polished Granite stone (Leather Finsh) for treads and risers of steps and staircase including cutting, moulding on tread edges as specified with polishing, fixing with cement mortar 1:4, including curing,cleaning etc complete. (basic rate= 220/- Sqft) |
| 84 | Providing and fixing 20 to 25 mm thk M/C cut high polished Kotah stone for treads and risers of steps and staircase including cutting, moulding on tread edges as specified with polishing, fixing with cement mortar 1:4, including curing,cleaning etc complete. |
| 85 | Providing and fixing 20 to 25 mm thk high polished Granite stone (Leather Finsh) for flooring, cladding including cutting, moulding on tread edges as specified with polishing, fixing with cement mortar 1:4, including curing,cleaning etc complete. (basic rate= 220/- Sqft) |
| 86 | Providing and fixing 20 to 25 mm thk M/C cut high polished Kotah stone for flooring with filling the joints with epoxy grout including cutting, moulding on tread edges as specified with polishing, fixing with cement mortar 1:4, including curing,cleaning etc complete. |
| 87 | Providing and fixing approved size (6mm*12mm) and shape brass patti with cement slury as per instruction etc. complete |
| 88 | Providing and fixing in required positions Granite skirting 75mm high above flooring flush with plaster face with matching skirting joints to flooring joints with cement including curing and cleaning complete. |
| 89 | Providing and fixing in required positions Kotah stone skirting 75mm to 100 mm high above flooring flush with plaster face with matching skirting joints to flooring joints with cement including curing and cleaning complete. |
| 90 | Fixing of exising stone steps & flooring with filling the joints with epoxy grout including cutting, moulding on tread edges as specified with polishing, fixing with cement mortar 1:4, including curing,cleaning etc complete. |
| 91 | WATERPROOFING(Note : Measurement should be taken from wall to wall) |
| 92 | Providing and laying cement based water proofing treatment to terrace slab, (India water proofing ) with brick bats laid in required slope to drain the water for any span after cleaning the base surface applying a coat of cement slurry & mixed with approved water proofing compound and laying the brick bats on bottom layer of CM 1 :5 and mixed with approved water proofing compound filling upto half depth of brick bats, curing this layer for 3 days,applying cement slurry over this layer Jointing of brick bats with CM 1:3 & mixed with approved water proofing compound and finally top finishing with average 20mm thick layer of same mortar including finishing the surface smooth with cement slurry mixed with approved water proofing compound, marking the finished surface with false squares of 300mm x 300mm, making the junctions at the parapets rounded & tapered towards top for required height with drip mould at the junction of plasterand curing etc. covering 10 years guarantee on court fee stamp including ponding test etc complete as directed. |
| 93 | Providing & Laying chemical waterproofing (Make Pidilite/Dr Fixit/Seiko or equal) for the base & walls including filling of construction joint making groove,Injection Grouting and 3 coat of crystalline material etc complete as directed. |
| 94 | PAINTING WORK |
| 95 | Providing & applying Acrylic Emulsion Paint of Asian/Nerolac of approved shade with two coat of primer,two coat of ready made putty including surface preparation , applying three coats paint mat finish, doing work as per manufacturer specification including cleaning the surface thoroughly with sandpaper, including scaffolding at all level etc. and cleaning of floors, door window frames, covings etc. Complete as directed by Engineer/ Owner. (Final coat will be applied only after completing of all jobs including the other agencies as well.) |
| 96 | Providing and applying exterior paint minimum two coats of approved shade of Asian Apex/ ICI Weather Shield/ Nerolac Excel paint in or equivalent approved make including one coat of exterior primer of Asian/ICI/Nerolac to all type of external surfaces of plastered work (I.e. sandfaced plaster, smooth cement plaster and rough cast plaster etc.) or concrete surfaces at all levels including Scaffolding, cleaning the surfaces, curing etc. complete as per manufacturers specifications & as directed by Engineer/ Owner. |
| 97 | DRY WALL & CLADDING WORK |
| 98 | Rate inclusive of providing supportserrecting scaffolding etc.. |
| 99 | Providing and laying Basalt stone work,chiseling and making decorative of stoneas per drawings, specifications including all tools , tackle ,lead -lift and necessary scafolding etc complete as directed. |
| 100 | Providing and laying Limestone stone work,chiseling and making decorative of stoneas per drawings, specifications including all tools , tackle ,lead -lift and necessary scafolding etc complete as directed. |
| 101 | Providing and applying of pointing works to all basalt stone joints,raised 5 mm thk and 25 mm wide in cement mortor 1:2 with proper uniform groove decorative in line and level etc complete |
| 102 | Providing and laying Sand stone (with moulding) of width 125mm in required positions in cladding of approved coloured and pattern on a bedding of 1:4 cement mortarincluding curing and finishing complete. |
| 103 | Providing and Fixing Stick / Ladder type - Curtain Wall glazing having combination of Clear and Reflective Glass. All Mullion members shall be as per drawing and design given. All glasses shall be double glass(DGU). Rate to include top hung openable members, working at all heights, sealant application, etc complete |
| 104 | Providing and fixing MS sheets of 0.3 mm for claddning with CNC cutting, bending including support structure and required accessories. The MS jali shall be anodised/ powder coated and support sturcture shall be spray painted with Epoxy paint. |
| 105 | MS STRUCTURAL WORK |
| 106 | Providing, fabricating, welding, bolting, erecting & fixing in position ISMC, ISA, MS plates etc. Jindal make for all types of structural steel works like columns beams, rafters, trusses, purlins, frame for louvers, bracing, staircase, ladders, sag rods, pipe bridges etc made up of rolled up sections with moment or shear connections, shop/site fabricated including all accessories viz nuts, bolts, anchor fastners, cleats, gussets, suspenders, Anchor fastener of specified sizes etc as per drawing and specification complete as directed by Engineer/Owner. The rate to including painting one coat of Zinc Chromate primer and over it two coats of EPOXY paint of approved quality (Asian, Nerolac), nut & bolts, scaffolding, stagging, etc & same will not be measured for payment.The rate shall include for preparing & providing detailed fabrication drawings based on design drawings & getting the same approved from the Engineer/Owner. |
| 107 | Providing, fabricating, welldiing, bolting, erecting & fixing of MS Tubular hollow Section of Tata Make for trusses, rafter, purlin, column, tie runner etc. including all accessories viz nuts, bolts, anchor fastners, cleats, gussets, suspenders, Anchor fastener as per specified size as per detailed drawings and instruction including providing one coat of epoxy paint primer and two coats of epoxypaint of approved quality and make and shade etc all complete as directed. |
| 108 | Providing, fabricating and erecting GI chain link of specified dimensions 50 x 50 mm 8 gauge square size to be fixed on ms structure including nuts, bolts, 1 coat of red oxide, 2 coats of oil painting etc. complete. (Supporting structural works will be paid under relevant item) |
| 109 | Providing and fixing in position decorative SS hand Railing ( all material should be in 16 Guage) for staircase of SS grade 304 brush finish with 25 x 50mm rectangular top rail and 12mm dia 3 nos parrallel to top rail and verticals 25 x 50 mm rectangular pipe at 900 mm c/c inluding fixing in granite steps etc complete as per drawing complete as approved by Architect. (Railing height 1.05mtr) |
| 110 | Providing, Fabricating & Fixing of SS 304 for SS Gate ( all material should be in 16 Guage) or specified object as per specified size shown in detailed drawings and instruction including brush finish to achieve smooth surface compling GMP (Good Manufacturing Processes) requirements etc complete as directed. |
| 111 | Providing, Fabricating & Fixing of SS 304 for SS grills specified object as per specified size shown in detailed drawings and instruction including brush finish to achieve smooth surface compling GMP (Good Manufacturing Processes) requirements etc complete as directed. |
| 112 | STRENGTHNING WORK |
| 113 | Strengthening structural elementswith non metallic composite fiber wrapping systemcomprise of 600 GSM uni-directional carbon fiber sheet and compatible saturant, Profiling: Applying compatible primer on prepared substrate, Filling the holes and uneven surface with thixotropic putty etc. complete Wrapping: Wrapping the fiber sheet to structural element at desired orientation using tamping roller to avoid any air voids etc. repeat the same procedure for multiple layer with the interval of 8 hrs. Second Coat: Applying second coat of saturant after min. 12 hrs, rectify air voids if any . (Mode of measurement: Per sq.mt of carbon fiber sheet consumed and not surface area of application) |
| 114 | ROOFING WORK |
| 115 | Measurement should be taken for plan area only. |
| 116 | Providing and fixing in position CRIL/Interarchmake 0.8 mm thick double layer Precoated Al-Znc alloy coated steel sheets forroofing and cladding , high yield strength of 550 MPA with minimum overlap of 200mm.It should be fixed with Hilti make self drilled, self tapping (SDST) screw with EPDM metal washer and sealant as per detail drawing and as per site instructions including making watta at junction of wall and roofing, scaffolding, staging etc all complete as directed .(including Ridges, flashings, crimping of sheets,fasteners, gaskets, washers, PU foam fillers to ensure air tightness etc) |
| 117 | Providing and fixing in position Rainwater gutter of width 300mm in width and 400mm in depth finish dimensions for roofing including all fastners, gaskets, washers, PU foam fillers to ensure air tightness, scaffolding, staging etc as per detail drawing and as per site instructions all complete as directed. |
| 118 | Providing & Fixing M.S. downtake pipe ( 300 mm Dia with THK 6 mm) including welding, clamping, screwing etc complete as directed |
| 119 | Same as above 750 mm Dia |
| 120 | Providing and fixing valley gutter of 24 B.W.G. (1 mm) plain precoated as directed by client galvanised iron sheets 90 cm. wide of specified width supported on wooden plank with brackets of 20 x 20 x 2.5 mm angles placed at 90 cm centre to centre including painting of angles, drilling holes, placing in position including two coats of coal-tarring the upper surface of plank (excluding painting to under side of plank) Spec. No. : Bd.R.10 Page No. 455 |